Yasuo Takatsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yasuo Takatsu has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
- Tosiaki Miyati
Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan
27 shared publications - Masafumi Nakamura
Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan; Department of Radiological Technology, Faculty of Health and Welfare, Tokushima Bunri University, 1314-1 Shido, Sanuki, Kagawa 769-2193, Japan
11 shared publications Tosiaki Miyati
Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa, 920-0942, Japan
9 shared publications- Satoshi Kobayashi
Department of Radiology, Kanazawa University Graduate School of Medical Sciences, Kanazawa, Japan
5 shared publications - Yuichi Suzuki
Radiology Center, The University of Tokyo Hospital, Tokyo, Japan
5 shared publications - Soma Kumasaka
Department of Applied Medical Imaging, Gunma University Graduate School of Medicine, Maebashi, Japan
4 shared publications
Latest Publications
- 29 July 2026
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (3) , 1579-1594
Evaluation of generative adversarial network-based postprocessing super-resolution for lumbar spine magnetic resonance imaging
- 29 July 2026
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 49 (3) , 1579-1594
Evaluation of generative adversarial network-based postprocessing super-resolution for lumbar spine magnetic resonance imaging
- 6 June 2026
- Published by Elsevier in Clinical Radiology
- Vol. 99, 107405
Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with mammography
- 6 June 2026
- Published by Elsevier in Clinical Radiology
- Vol. 99, 107405
Semiautomated magnetic resonance imaging-based breast density measurement from routine sequences: comparison with mammography
- Open Access
- 1 January 2026
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 82 (11) , 26-1704
Improved Conspicuity of Subtle Contrast Enhancement Using 3D Phase-sensitive Inversion Recovery
【目的】臨床において,造影効果の低い高悪性度膠芽腫や小径転移性脳腫瘍では,病変評価に苦慮する場合がある.本研究では,心筋遅延造影MRIで用いられるphase-sensitive inversion recovery(PSIR)法に着目し,three-dimensional (3D) PSIR法の撮像パラメータ最適化および従来法との比較をファントム実験にて行った.【方法】MR装置はPhilips(Best, the Netherlands)社製Achieva 1.5 Tを使用し,白質・灰白質および低濃度ガドリニウム造影効果を模擬したファントムを作成した.3D-T1 turbo field echo法にPSIRを併用し,TFE factor,shot interval(SI),TI delay time(TI)を変化させ,contrast-to-noise ratio(CNR)を評価した.【結果】TFE factorは10で高いCNRを示した.Shot intervalは延長に伴いCNRが増加する傾向を示したが,2000 ms以降ではCNRの増加が緩やかとなった.また,TI delay timeは600~1000 msで高いCNRを示した.従来の3D fast field echo(3D-FFE)法と比較し,3D-PSIR法では2倍以上高いCNRが得られた.【結語】3D-PSIR法は,適切な撮像条件の設定により,淡い造影効果を模擬したファントムにおいて従来の3D-FFE法と比較して高いCNRを示した.本研究で得られた知見は,淡い造影効果を示す脳腫瘍への臨床応用に向けた基礎的資料となる可能性がある.
- 1 January 2026
- Published by Japanese Society of Radiological Technology in Japanese Journal of Radiological Technology
- Vol. 82 (11) , 26-1704
Open AccessImproved Conspicuity of Subtle Contrast Enhancement Using 3D Phase-sensitive Inversion Recovery
【目的】臨床において,造影効果の低い高悪性度膠芽腫や小径転移性脳腫瘍では,病変評価に苦慮する場合がある.本研究では,心筋遅延造影MRIで用いられるphase-sensitive inversion recovery(PSIR)法に着目し,three-dimensional (3D) PSIR法の撮像パラメータ最適化および従来法との比較をファントム実験にて行った.【方法】MR装置はPhilips(Best, the Netherlands)社製Achieva 1.5 Tを使用し,白質・灰白質および低濃度ガドリニウム造影効果を模擬したファントムを作成した.3D-T1 turbo field echo法にPSIRを併用し,TFE factor,shot interval(SI),TI delay time(TI)を変化させ,contrast-to-noise ratio(CNR)を評価した.【結果】TFE factorは10で高いCNRを示した.Shot intervalは延長に伴いCNRが増加する傾向を示したが,2000 ms以降ではCNRの増加が緩やかとなった.また,TI delay timeは600~1000 msで高いCNRを示した.従来の3D fast field echo(3D-FFE)法と比較し,3D-PSIR法では2倍以上高いCNRが得られた.【結語】3D-PSIR法は,適切な撮像条件の設定により,淡い造影効果を模擬したファントムにおいて従来の3D-FFE法と比較して高いCNRを示した.本研究で得られた知見は,淡い造影効果を示す脳腫瘍への臨床応用に向けた基礎的資料となる可能性がある.
- 5 September 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1267-1282
Classification of liver lesions based on temporal changes in hepatobiliary phase contrast on magnetic resonance imaging: a preliminary study
This study evaluated whether temporal changes from the dynamic late phase to the hepatobiliary phase using gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid supported liver tumor classification. A total of 147 patients with 165 lesions (hepatocellular carcinoma [HCC], metastases, and hemangiomas) underwent 3.0 T MRI. Quantitative liver lesion contrast (Q-LLC) and its rate of change (%) at 3, 10, and 15 min postcontrast were analyzed. Tumors were stratified according to albumin–bilirubin (ALBI) grade. For ALBI grade 1, the Q-LLC significantly differed at 3 min and 10 min (P < 0.05). Q-LLC increased over time, and the rate of change was the lowest in HCC, followed by metastases, and was the highest in hemangiomas. Significant differences in the rate of change were observed among tumor types for ALBI grade 1 (P < 0.01). These findings suggest that the Q-LLC rate of change may aid in liver tumor classification, particularly in patients with preserved liver function.
- 5 September 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1267-1282
Classification of liver lesions based on temporal changes in hepatobiliary phase contrast on magnetic resonance imaging: a preliminary study
This study evaluated whether temporal changes from the dynamic late phase to the hepatobiliary phase using gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid supported liver tumor classification. A total of 147 patients with 165 lesions (hepatocellular carcinoma [HCC], metastases, and hemangiomas) underwent 3.0 T MRI. Quantitative liver lesion contrast (Q-LLC) and its rate of change (%) at 3, 10, and 15 min postcontrast were analyzed. Tumors were stratified according to albumin–bilirubin (ALBI) grade. For ALBI grade 1, the Q-LLC significantly differed at 3 min and 10 min (P < 0.05). Q-LLC increased over time, and the rate of change was the lowest in HCC, followed by metastases, and was the highest in hemangiomas. Significant differences in the rate of change were observed among tumor types for ALBI grade 1 (P < 0.01). These findings suggest that the Q-LLC rate of change may aid in liver tumor classification, particularly in patients with preserved liver function.
- 29 July 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1283-1293
Temporal changes in sucrose phantoms for magnetic resonance imaging: effects of preparation temperatures
This study investigated the effects of preparation temperature and usage period on the relaxation times and apparent diffusion coefficients (ADC) of sucrose phantoms to enhance imaging reliability. Phantoms were prepared using 10% sucrose solutions at 20, 50, and 80 °C. T1 and T2 relaxation times and ADC were monitored over 80 days using magnetic resonance imaging on a 1.5 T system. T2 relaxation time in 50 °C solutions increased from 245.5 to 1579 ms, while 80 °C solutions showed the highest stability (coefficient of variation ≈ 1.8%). T1 relaxation time changes were minimal, and ADC decreased at an average rate of 2.19 × 10-6 mm2/s per day. Bacteria were observed in the sucrose solution, and higher protein concentrations were strongly correlated with decreased 1/T2. In conclusion, sucrose phantoms exhibited temperature-dependent stability, with 80 °C preparations providing the most reliable T2 relaxation time.
- 29 July 2025
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 18 (4) , 1283-1293
Temporal changes in sucrose phantoms for magnetic resonance imaging: effects of preparation temperatures
This study investigated the effects of preparation temperature and usage period on the relaxation times and apparent diffusion coefficients (ADC) of sucrose phantoms to enhance imaging reliability. Phantoms were prepared using 10% sucrose solutions at 20, 50, and 80 °C. T1 and T2 relaxation times and ADC were monitored over 80 days using magnetic resonance imaging on a 1.5 T system. T2 relaxation time in 50 °C solutions increased from 245.5 to 1579 ms, while 80 °C solutions showed the highest stability (coefficient of variation ≈ 1.8%). T1 relaxation time changes were minimal, and ADC decreased at an average rate of 2.19 × 10-6 mm2/s per day. Bacteria were observed in the sucrose solution, and higher protein concentrations were strongly correlated with decreased 1/T2. In conclusion, sucrose phantoms exhibited temperature-dependent stability, with 80 °C preparations providing the most reliable T2 relaxation time.
- 7 July 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (3) , 971-986
Optimization of three-dimensional T2-weighted image sequences in female pelvic magnetic resonance imaging
This study aimed to characterize T2-weighted fast spin-echo three-dimensional (3D) magnetic resonance images (MRI) by using variable refocusing angle (VRFA) in female pelvic organs and to extract clinically relevant parameters. A 3T MRI system was used, and contrast-to-noise ratio (CNR) and full width at half maximum (FWHM) were calculated using a phantom mimicking the uterine three-layered structure to confirm the characteristics of low-constant VRFA (LC-VRFA) and tissue-specific VRFA (TS-VRFA) under changing parameters. Parameters that were relatively well-evaluated in the phantom study were combined and visually evaluated as an overall assessment by volunteer images, using common turbo spin-echo (TSE) coefficients and equivalent TE (TEequiv). In most combinations, CNR tended to be higher for longer TEequiv for each TSE factor for both LC- and TS-VRFA, but particularly higher with RFA of 60°–90°, TSE factor of 60–90, and TEequiv of 90–100 ms. TS-VRFA was high in the common TSE factor and TEequiv, with some exceptions. In all combinations, the FWHM of LC-VRFA was narrower than TS-VRFA (P < 0.01). For visual evaluation of volunteer images, LC-VRFA was higher than TS-VRFA (P < 0.05). In LC-VRFA, the upper combinations of RFA (°)–TSE factor–TEequiv (ms) were 90–80–100, 90–90–100, and 90–60–100, respectively. We characterized VRFA 3D T2-weighted MR images for female pelvic organs, extracted optimal parameters. The better VRFA was LC-VRFA, with RFA of 60°–90°, TSE factor of 60–90, and TEequiv of 90–100 ms.
- 7 July 2025
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 48 (3) , 971-986
Optimization of three-dimensional T2-weighted image sequences in female pelvic magnetic resonance imaging
This study aimed to characterize T2-weighted fast spin-echo three-dimensional (3D) magnetic resonance images (MRI) by using variable refocusing angle (VRFA) in female pelvic organs and to extract clinically relevant parameters. A 3T MRI system was used, and contrast-to-noise ratio (CNR) and full width at half maximum (FWHM) were calculated using a phantom mimicking the uterine three-layered structure to confirm the characteristics of low-constant VRFA (LC-VRFA) and tissue-specific VRFA (TS-VRFA) under changing parameters. Parameters that were relatively well-evaluated in the phantom study were combined and visually evaluated as an overall assessment by volunteer images, using common turbo spin-echo (TSE) coefficients and equivalent TE (TEequiv). In most combinations, CNR tended to be higher for longer TEequiv for each TSE factor for both LC- and TS-VRFA, but particularly higher with RFA of 60°–90°, TSE factor of 60–90, and TEequiv of 90–100 ms. TS-VRFA was high in the common TSE factor and TEequiv, with some exceptions. In all combinations, the FWHM of LC-VRFA was narrower than TS-VRFA (P < 0.01). For visual evaluation of volunteer images, LC-VRFA was higher than TS-VRFA (P < 0.05). In LC-VRFA, the upper combinations of RFA (°)–TSE factor–TEequiv (ms) were 90–80–100, 90–90–100, and 90–60–100, respectively. We characterized VRFA 3D T2-weighted MR images for female pelvic organs, extracted optimal parameters. The better VRFA was LC-VRFA, with RFA of 60°–90°, TSE factor of 60–90, and TEequiv of 90–100 ms.