Yonni Friedlander
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yonni Friedlander has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Giles Santyr
Translational Medicine Program, The Hospital for Sick Children, Toronto, Canada; Department of Medical Biophysics, University of Toronto, Toronto, ON, Canada
5 shared publicationsDaniel Li
Translational Medicine Program Hospital for Sick Children Toronto Ontario Canada
4 shared publicationsAndrea Kassner
Translational Medicine Program Hospital for Sick Children Toronto Ontario Canada
3 shared publicationsBrandon Zanette
Translational Medicine Program, The Hospital for Sick Children, Toronto, Canada
3 shared publications- Brandon Zanette
Translational Medicine Program The Hospital for Sick Children Toronto Ontario Canada
3 shared publications - Andras A. Lindenmaier
Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
2 shared publications
Latest Publications
- Open Access
- 19 February 2024
- Published by Elsevier in Academic Radiology
- Vol. 31 (8) , 3416-3426
Phase-Resolved Functional Lung (PREFUL) MRI to Quantify Ventilation: Feasibility and Physiological Relevance in Severe Asthma
- 19 February 2024
- Published by Elsevier in Academic Radiology
- Vol. 31 (8) , 3416-3426
Open AccessPhase-Resolved Functional Lung (PREFUL) MRI to Quantify Ventilation: Feasibility and Physiological Relevance in Severe Asthma
- 25 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 1083-1091
A 3D stack‐of‐spirals approach for rapid hyperpolarized 129Xe ventilation mapping in pediatric cystic fibrosis lung disease
Purpose: To demonstrate the feasibility of a rapid 3D stack‐of‐spirals (3D‐SoS) imaging acquisition for hyperpolarized 129Xe ventilation mapping in healthy pediatric participants and pediatric cystic fibrosis (CF) participants, in comparison to conventional Cartesian multislice (2D) gradient‐recalled echo (GRE) imaging.Methods: The 2D‐GRE and 3D‐SoS acquisitions were performed in 13 pediatric participants (5 healthy, 8 CF) during separate breath‐holds. Images from both sequences were compared on the basis of ventilation defect percent (VDP) and other measures of image similarity. The nadir of transient oxygen saturation (SpO2) decline due to xenon breath‐holding was measured with pulse oximetry, and expressed as a percent change relative to baseline.Results: 129Xe ventilation images were acquired in a breath‐hold of 1.2–1.8 s with the 3D‐SoS sequence, compared to 6.2–8.8 s for 2D‐GRE. Mean ± SD VDP measures for 2D‐GRE and 3D‐SoS sequences were 5.02 ± 1.06% and 5.28 ± 1.08% in healthy participants, and 18.05 ± 8.26% and 18.75 ± 6.74% in CF participants, respectively. Across all participants, the intraclass correlation coefficient of VDP measures for both sequences was 0.98 (95% confidence interval: 0.94–0.99). The percent change in SpO2 was reduced to −2.1 ± 2.7% from −5.2 ± 3.5% with the shorter 3D‐SoS breath‐hold.Conclusion: Hyperpolarized 129Xe ventilation imaging with 3D‐SoS yielded images approximately five times faster than conventional 2D‐GRE, reducing SpO2 desaturation and improving tolerability of the xenon administration. Analysis of VDP and other measures of image similarity demonstrate excellent agreement between images obtained with both sequences. 3D‐SoS holds significant potential for reducing the acquisition time of hyperpolarized 129Xe MRI, and/or increasing spatial resolution while adhering to clinical breath‐hold constraints.
- 25 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 1083-1091
A 3D stack‐of‐spirals approach for rapid hyperpolarized 129Xe ventilation mapping in pediatric cystic fibrosis lung disease
Purpose: To demonstrate the feasibility of a rapid 3D stack‐of‐spirals (3D‐SoS) imaging acquisition for hyperpolarized 129Xe ventilation mapping in healthy pediatric participants and pediatric cystic fibrosis (CF) participants, in comparison to conventional Cartesian multislice (2D) gradient‐recalled echo (GRE) imaging.Methods: The 2D‐GRE and 3D‐SoS acquisitions were performed in 13 pediatric participants (5 healthy, 8 CF) during separate breath‐holds. Images from both sequences were compared on the basis of ventilation defect percent (VDP) and other measures of image similarity. The nadir of transient oxygen saturation (SpO2) decline due to xenon breath‐holding was measured with pulse oximetry, and expressed as a percent change relative to baseline.Results: 129Xe ventilation images were acquired in a breath‐hold of 1.2–1.8 s with the 3D‐SoS sequence, compared to 6.2–8.8 s for 2D‐GRE. Mean ± SD VDP measures for 2D‐GRE and 3D‐SoS sequences were 5.02 ± 1.06% and 5.28 ± 1.08% in healthy participants, and 18.05 ± 8.26% and 18.75 ± 6.74% in CF participants, respectively. Across all participants, the intraclass correlation coefficient of VDP measures for both sequences was 0.98 (95% confidence interval: 0.94–0.99). The percent change in SpO2 was reduced to −2.1 ± 2.7% from −5.2 ± 3.5% with the shorter 3D‐SoS breath‐hold.Conclusion: Hyperpolarized 129Xe ventilation imaging with 3D‐SoS yielded images approximately five times faster than conventional 2D‐GRE, reducing SpO2 desaturation and improving tolerability of the xenon administration. Analysis of VDP and other measures of image similarity demonstrate excellent agreement between images obtained with both sequences. 3D‐SoS holds significant potential for reducing the acquisition time of hyperpolarized 129Xe MRI, and/or increasing spatial resolution while adhering to clinical breath‐hold constraints.
- 28 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (4) , 1971-1979
Hyperpolarized 129Xe MRI of the rat brain with chemical shift saturation recovery and spiral‐IDEAL readout
Purpose: To demonstrate the feasibility of 129Xe chemical shift saturation recovery (CSSR) combined with spiral‐IDEAL imaging for simultaneous measurement of the time‐course of red blood cell (RBC) and brain tissue signals in the rat brain.Methods: Images of both the RBC and brain tissue 129Xe signals from the brains of five rats were obtained using interleaved spiral‐IDEAL imaging following chemical shift saturation pulses applied at multiple CSSR delay times, τ. A linear fit of the signals to τ was used to calculate the slope of the signal for both RBC and brain tissue compartments on a voxel‐by‐voxel basis. Gas transfer was evaluated by measuring the ratio of the whole brain tissue‐to‐RBC signal intensities as a function of τ. To investigate the relationship between the CSSR images and gas transfer in the brain, the experiments were repeated during hypercapnic ventilation.Results: Hypercapnia, affected the ratio of the tissue‐to‐RBC signal intensity (p = 0.026), consistent with an increase in gas transfer.Conclusion: CSSR with spiral‐IDEAL imaging is feasible for acquisition of 129Xe RBC and brain tissue time‐course images in the rat brain. Differences in the time‐course of the signal intensity ratios are consistent with gas transfer changes expected under hypercapnic conditions.
- 28 November 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 87 (4) , 1971-1979
Hyperpolarized 129Xe MRI of the rat brain with chemical shift saturation recovery and spiral‐IDEAL readout
Purpose: To demonstrate the feasibility of 129Xe chemical shift saturation recovery (CSSR) combined with spiral‐IDEAL imaging for simultaneous measurement of the time‐course of red blood cell (RBC) and brain tissue signals in the rat brain.Methods: Images of both the RBC and brain tissue 129Xe signals from the brains of five rats were obtained using interleaved spiral‐IDEAL imaging following chemical shift saturation pulses applied at multiple CSSR delay times, τ. A linear fit of the signals to τ was used to calculate the slope of the signal for both RBC and brain tissue compartments on a voxel‐by‐voxel basis. Gas transfer was evaluated by measuring the ratio of the whole brain tissue‐to‐RBC signal intensities as a function of τ. To investigate the relationship between the CSSR images and gas transfer in the brain, the experiments were repeated during hypercapnic ventilation.Results: Hypercapnia, affected the ratio of the tissue‐to‐RBC signal intensity (p = 0.026), consistent with an increase in gas transfer.Conclusion: CSSR with spiral‐IDEAL imaging is feasible for acquisition of 129Xe RBC and brain tissue time‐course images in the rat brain. Differences in the time‐course of the signal intensity ratios are consistent with gas transfer changes expected under hypercapnic conditions.
- 1 September 2021
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 321 (3) , L507-L517
Hyperpolarized 129Xe magnetic resonance spectroscopy in a rat model of bronchopulmonary dysplasia
Premature infants often require mechanical ventilation and oxygen therapy, which can result in bronchopulmonary dysplasia (BPD), characterized by developmental arrest and impaired lung function. Conventional clinical methods for assessing the prenatal lung are not adequate for the detection and assessment of long-term health risks in infants with BPD, highlighting the need for a noninvasive tool for the characterization of lung microstructure and function. Theoretical diffusion models, like the model of xenon exchange (MOXE), interrogate alveolar gas exchange by predicting the uptake of inert hyperpolarized (HP) 129Xe gas measured with HP 129Xe magnetic resonance spectroscopy (MRS). To investigate HP 129Xe MRS as a tool for noninvasive characterization of pulmonary microstructural and functional changes in vivo, HP 129Xe gas exchange data were acquired in an oxygen exposure rat model of BPD that recapitulates the fewer and larger distal airways and pulmonary vascular stunting characteristics of BPD. Gas exchange parameters from MOXE, including airspace mean chord length ( Lm), apparent hematocrit in the pulmonary capillaries (HCT), and pulmonary capillary transit time ( tx), were compared with airspace mean axis length and area density (MAL and ρA) and percentage area of tissue and air (PTA and PAA) from histology. Lm was significantly larger in the exposed rats ( P = 0.003) and correlated with MAL, ρA, PTA, and PAA (0.59<|ρ|x are also discussed. These findings support the use of HP 129Xe MRS for detecting fewer, enlarged distal airways in this rat model of BPD, and potentially in humans.
- 1 September 2021
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 321 (3) , L507-L517
Hyperpolarized 129Xe magnetic resonance spectroscopy in a rat model of bronchopulmonary dysplasia
Premature infants often require mechanical ventilation and oxygen therapy, which can result in bronchopulmonary dysplasia (BPD), characterized by developmental arrest and impaired lung function. Conventional clinical methods for assessing the prenatal lung are not adequate for the detection and assessment of long-term health risks in infants with BPD, highlighting the need for a noninvasive tool for the characterization of lung microstructure and function. Theoretical diffusion models, like the model of xenon exchange (MOXE), interrogate alveolar gas exchange by predicting the uptake of inert hyperpolarized (HP) 129Xe gas measured with HP 129Xe magnetic resonance spectroscopy (MRS). To investigate HP 129Xe MRS as a tool for noninvasive characterization of pulmonary microstructural and functional changes in vivo, HP 129Xe gas exchange data were acquired in an oxygen exposure rat model of BPD that recapitulates the fewer and larger distal airways and pulmonary vascular stunting characteristics of BPD. Gas exchange parameters from MOXE, including airspace mean chord length ( Lm), apparent hematocrit in the pulmonary capillaries (HCT), and pulmonary capillary transit time ( tx), were compared with airspace mean axis length and area density (MAL and ρA) and percentage area of tissue and air (PTA and PAA) from histology. Lm was significantly larger in the exposed rats ( P = 0.003) and correlated with MAL, ρA, PTA, and PAA (0.59<|ρ|x are also discussed. These findings support the use of HP 129Xe MRS for detecting fewer, enlarged distal airways in this rat model of BPD, and potentially in humans.
- 9 April 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (3) , 1187-1193
Effect of inhaled oxygen concentration on 129Xe chemical shift of red blood cells in rat lungs
Purpose: To investigate the dependence of dissolved 129Xe chemical shift on the fraction of inhaled oxygen, FiO2, in the lungs of healthy rats.Methods: The chemical shifts of 129Xe dissolved in red blood cells, δRBC, and blood plasma and/or tissue, δPlasma, were measured using MRS in 12 Sprague Dawley rats mechanically ventilated at FiO2 values of 0.14, 0.19, and 0.22. Regional effects on the chemical shifts were controlled using a chemical shift saturation recovery sequence with a fixed delay time. MRS was also performed at an FiCO2 value of 0.085 to investigate the potential effect of the vascular response on δRBC and δPlasma.Results: δRBC increased with decreasing FiO2 (P = .0002), and δPlasma showed no dependence on FiO2 (P = .23). δRBC at FiCO2 = 0 (210.7 ppm ± 0.1) and at FiCO2 = 0.085 (210.6 ppm ± 0.2) were not significantly different (P = .67). δPlasma at FiCO2 = 0 (196.9 ppm ± 0.3) and at FiCO2 = 0.085 (197.0 ppm ± 0.1) were also not significantly different (P = .81).Conclusion: Rat lung δRBC showed an inverse relationship to FiO2, opposite to the relationship previously demonstrated for in vitro human blood. Rat lung δRBC did not depend on FiCO2.
- 9 April 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (3) , 1187-1193
Effect of inhaled oxygen concentration on 129Xe chemical shift of red blood cells in rat lungs
Purpose: To investigate the dependence of dissolved 129Xe chemical shift on the fraction of inhaled oxygen, FiO2, in the lungs of healthy rats.Methods: The chemical shifts of 129Xe dissolved in red blood cells, δRBC, and blood plasma and/or tissue, δPlasma, were measured using MRS in 12 Sprague Dawley rats mechanically ventilated at FiO2 values of 0.14, 0.19, and 0.22. Regional effects on the chemical shifts were controlled using a chemical shift saturation recovery sequence with a fixed delay time. MRS was also performed at an FiCO2 value of 0.085 to investigate the potential effect of the vascular response on δRBC and δPlasma.Results: δRBC increased with decreasing FiO2 (P = .0002), and δPlasma showed no dependence on FiO2 (P = .23). δRBC at FiCO2 = 0 (210.7 ppm ± 0.1) and at FiCO2 = 0.085 (210.6 ppm ± 0.2) were not significantly different (P = .67). δPlasma at FiCO2 = 0 (196.9 ppm ± 0.3) and at FiCO2 = 0.085 (197.0 ppm ± 0.1) were also not significantly different (P = .81).Conclusion: Rat lung δRBC showed an inverse relationship to FiO2, opposite to the relationship previously demonstrated for in vitro human blood. Rat lung δRBC did not depend on FiCO2.
- 9 December 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (1) , 52-60
Chemical shift of 129Xe dissolved in red blood cells: Application to a rat model of bronchopulmonary dysplasia
Purpose: To measure the chemical shift of hyperpolarized 129Xe dissolved in the red blood cells(δRBC) of a cohort of rats exposed to hyperoxia and intermittent hypoxia (IH) to mimic human bronchopulmonary dysplasia, and to investigate the effect of xenon‐blood distribution time on δRBC.Methods: δRBC was measured from spectra acquired using a chemical shift saturation recovery sequence from 15 Sprague‐Dawley rats exposed to hyperoxia‐IH and 10 age‐matched control rats. Sensitization to the xenon‐blood distribution time was achieved by varying the time between saturation pulses, τ. δRBC was compared with blood fraction measured by histology of the cohort and blood oxygenation measured directly using pulse oximetry following a hypoxic challenge in an identically exposed cohort.Results: The mean δRBC in the hyperoxia‐IH exposed rats was 0.55 ± 0.04 ppm lower than that of the healthy cohort (P = .0038), and this difference did not depend on τ (P = .996). The blood fraction of the exposed cohort was lower than that of the healthy cohort (P = .0397). Oximetry measurements showed that the baseline arterial oxygen saturation (SaO2) of each cohort was not different (P = .72), but after a hypoxic challenge, the SaO2 of the exposed cohort was lower than that of the healthy cohort (P = .003).Conclusion: δRBC is reduced in rats exposed to hyperoxia‐IH compared with control rats. The change in δRBC is consistent with enhanced blood oxygen desaturation of the exposed cohort measured by pulse oximetry during a hypoxic challenge. This suggests that the observed change in δRBC reflects enhanced desaturation in the hyperoxia‐IH exposed cohort compared with the healthy cohort.
- 9 December 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (1) , 52-60
Chemical shift of 129Xe dissolved in red blood cells: Application to a rat model of bronchopulmonary dysplasia
Purpose: To measure the chemical shift of hyperpolarized 129Xe dissolved in the red blood cells(δRBC) of a cohort of rats exposed to hyperoxia and intermittent hypoxia (IH) to mimic human bronchopulmonary dysplasia, and to investigate the effect of xenon‐blood distribution time on δRBC.Methods: δRBC was measured from spectra acquired using a chemical shift saturation recovery sequence from 15 Sprague‐Dawley rats exposed to hyperoxia‐IH and 10 age‐matched control rats. Sensitization to the xenon‐blood distribution time was achieved by varying the time between saturation pulses, τ. δRBC was compared with blood fraction measured by histology of the cohort and blood oxygenation measured directly using pulse oximetry following a hypoxic challenge in an identically exposed cohort.Results: The mean δRBC in the hyperoxia‐IH exposed rats was 0.55 ± 0.04 ppm lower than that of the healthy cohort (P = .0038), and this difference did not depend on τ (P = .996). The blood fraction of the exposed cohort was lower than that of the healthy cohort (P = .0397). Oximetry measurements showed that the baseline arterial oxygen saturation (SaO2) of each cohort was not different (P = .72), but after a hypoxic challenge, the SaO2 of the exposed cohort was lower than that of the healthy cohort (P = .003).Conclusion: δRBC is reduced in rats exposed to hyperoxia‐IH compared with control rats. The change in δRBC is consistent with enhanced blood oxygen desaturation of the exposed cohort measured by pulse oximetry during a hypoxic challenge. This suggests that the observed change in δRBC reflects enhanced desaturation in the hyperoxia‐IH exposed cohort compared with the healthy cohort.