Siddharth Sadanand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Siddharth Sadanand has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Andras A. Lindenmaier
Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
2 shared publications - Brandon Zanette
Translational Medicine Program The Hospital for Sick Children Toronto Ontario Canada
2 shared publications Daniel Li
Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
2 shared publicationsElaine Stirrat
Translational Medicine Program, The Hospital for Sick Children, Toronto, Ontario, Canada
2 shared publications- Yonni Friedlander
Translational Medicine Program Hospital for Sick Children Toronto Ontario Canada
2 shared publications - Alexander Dunn
Canadian Nuclear Laboratories , Chalk River, Ontario K0J 1J0
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Decoupling qCEST fitted parameters: dependence on buffer chemistry and fitting régime
Chemical exchange saturation transfer (CEST) MRI detects exchangeable protons in metabolites, with signal governed by exchange rate (kex), T2, and pool size (f). Reproducibility is hindered by kex discrepancies across studies, arising from fitting parameter coupling, buffer conditions, experimental design (e.g., QUEST, QUESP, QUASS), and choice of analysis régime (steady-state vs. non-steady-state; SS vs. NSS).Using ammonium chloride (NH4Cl) as a model analyte, we investigated how buffering conditions, experimental design, and fitting model affect kex estimation. Multi-concentration CEST experiments were performed at 7T across saturation times and powers, comparing citrate buffer, common in the literature, to potassium hydrogen phthalate (KHP) as an amphoteric monoprotic alternative. Confidence intervals were assessed across buffer conditions and fitting models (single- vs. multi-concentration; SS vs. NSS). Parameter coupling was characterised via Markov chain Monte Carlo (MCMC) sampling.Findings highlight significant differences in kex under unbuffered (260 ± 4 Hz), KHP-buffered (180 ± 10 Hz), and citrate-buffered (160 ± 7 Hz) conditions. Multi-concentration NSS fitting effectively decoupled kex, f, and T2 (unbuffered fitting confidence intervals: 4 Hz, 0.04%, 10 ms, respectively), demonstrating robustness over single-concentration (3 Hz, 0.02%, 10600 ms) and SS (8 Hz, 0.09%, 190 ms) fits.These findings emphasize the importance of experimental design and analysis in improving the reliability of kex measurements, providing a pathway for more interpretable CEST experiments. Multi-concentration NSS fitting decouples CEST parameters, and buffer selection should reflect both the ionic strength and buffering capacity of the target biological compartment for exchange rates to be meaningfully comparable across studies.
- 24 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDecoupling qCEST fitted parameters: dependence on buffer chemistry and fitting régime
Chemical exchange saturation transfer (CEST) MRI detects exchangeable protons in metabolites, with signal governed by exchange rate (kex), T2, and pool size (f). Reproducibility is hindered by kex discrepancies across studies, arising from fitting parameter coupling, buffer conditions, experimental design (e.g., QUEST, QUESP, QUASS), and choice of analysis régime (steady-state vs. non-steady-state; SS vs. NSS).Using ammonium chloride (NH4Cl) as a model analyte, we investigated how buffering conditions, experimental design, and fitting model affect kex estimation. Multi-concentration CEST experiments were performed at 7T across saturation times and powers, comparing citrate buffer, common in the literature, to potassium hydrogen phthalate (KHP) as an amphoteric monoprotic alternative. Confidence intervals were assessed across buffer conditions and fitting models (single- vs. multi-concentration; SS vs. NSS). Parameter coupling was characterised via Markov chain Monte Carlo (MCMC) sampling.Findings highlight significant differences in kex under unbuffered (260 ± 4 Hz), KHP-buffered (180 ± 10 Hz), and citrate-buffered (160 ± 7 Hz) conditions. Multi-concentration NSS fitting effectively decoupled kex, f, and T2 (unbuffered fitting confidence intervals: 4 Hz, 0.04%, 10 ms, respectively), demonstrating robustness over single-concentration (3 Hz, 0.02%, 10600 ms) and SS (8 Hz, 0.09%, 190 ms) fits.These findings emphasize the importance of experimental design and analysis in improving the reliability of kex measurements, providing a pathway for more interpretable CEST experiments. Multi-concentration NSS fitting decouples CEST parameters, and buffer selection should reflect both the ionic strength and buffering capacity of the target biological compartment for exchange rates to be meaningfully comparable across studies.
- Open Access
- 30 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (19) , 19NT02
Design and testing of an MR-conditional six-degree-of-freedom phantom robot
Objective. Motion phantoms can help accelerate and reduce the associated costs of research focused on motion-robust imaging. Currently available phantom robots for magnetic resonance imaging (MRI) lack sufficient degrees of freedom (DOF) to replicate complex physiological motions. This work presents the design and testing of a six-DOF MR-conditional phantom robot to simulate such motions. Approach. The system was fabricated predominantly with 3D printed components as well as DC stepper motors. Testing validated the actuator’s functionality and conditionality with a 3 T MRI system. A Faraday cage to house the motors and electronics was constructed using a conductive coating on a 3D-printed shell. Main Results. The Faraday cage was found to reduce the noise power produced by the motors to the baseline level measured in the MRI without the robot being present within the MRI suite. A positional accuracy measured using a modified version of ISO 9283 was found to be 0.2 mm and a rotational accuracy of [−0.1°, 0.3°, −0.2°] were measured for the x, y, and z directions, respectively. Path accuracy for sample motions was found to have a positional accuracy of 0.3 mm and rotational accuracy of [0.1°, 0.1°, 0.1°]. Significance. The created six-DOF robot enhances the development and validation of motion-robust imaging in MRI. The presented design is covered by WO patent #2023/184043, 2023/09/28.
- 30 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (19) , 19NT02
Open AccessDesign and testing of an MR-conditional six-degree-of-freedom phantom robot
Objective. Motion phantoms can help accelerate and reduce the associated costs of research focused on motion-robust imaging. Currently available phantom robots for magnetic resonance imaging (MRI) lack sufficient degrees of freedom (DOF) to replicate complex physiological motions. This work presents the design and testing of a six-DOF MR-conditional phantom robot to simulate such motions. Approach. The system was fabricated predominantly with 3D printed components as well as DC stepper motors. Testing validated the actuator’s functionality and conditionality with a 3 T MRI system. A Faraday cage to house the motors and electronics was constructed using a conductive coating on a 3D-printed shell. Main Results. The Faraday cage was found to reduce the noise power produced by the motors to the baseline level measured in the MRI without the robot being present within the MRI suite. A positional accuracy measured using a modified version of ISO 9283 was found to be 0.2 mm and a rotational accuracy of [−0.1°, 0.3°, −0.2°] were measured for the x, y, and z directions, respectively. Path accuracy for sample motions was found to have a positional accuracy of 0.3 mm and rotational accuracy of [0.1°, 0.1°, 0.1°]. Significance. The created six-DOF robot enhances the development and validation of motion-robust imaging in MRI. The presented design is covered by WO patent #2023/184043, 2023/09/28.
- Open Access
Contactless Measurement of Vital Signs Using Thermal and RGB Cameras: A Study of COVID 19-Related Health Monitoring
In this study, a contactless vital signs monitoring system was proposed, which can measure body temperature (BT), heart rate (HR) and respiration rate (RR) for people with and without face masks using a thermal and an RGB camera. The convolution neural network (CNN) based face detector was applied and three regions of interest (ROIs) were located based on facial landmarks for vital sign estimation. Ten healthy subjects from a variety of ethnic backgrounds with skin colors from pale white to darker brown participated in several different experiments. The absolute error (AE) between the estimated HR using the proposed method and the reference HR from all experiments is beats/min (mean ± std), and the AE between the estimated RR and the reference RR from all experiments is breaths/min (mean ± std) at a distance of 0.6–1.2 m.Open AccessContactless Measurement of Vital Signs Using Thermal and RGB Cameras: A Study of COVID 19-Related Health Monitoring
In this study, a contactless vital signs monitoring system was proposed, which can measure body temperature (BT), heart rate (HR) and respiration rate (RR) for people with and without face masks using a thermal and an RGB camera. The convolution neural network (CNN) based face detector was applied and three regions of interest (ROIs) were located based on facial landmarks for vital sign estimation. Ten healthy subjects from a variety of ethnic backgrounds with skin colors from pale white to darker brown participated in several different experiments. The absolute error (AE) between the estimated HR using the proposed method and the reference HR from all experiments is beats/min (mean ± std), and the AE between the estimated RR and the reference RR from all experiments is breaths/min (mean ± std) at a distance of 0.6–1.2 m. - 1 September 2021
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 321 (3) , L507-L517
Hyperpolarized 129Xe magnetic resonance spectroscopy in a rat model of bronchopulmonary dysplasia
Premature infants often require mechanical ventilation and oxygen therapy, which can result in bronchopulmonary dysplasia (BPD), characterized by developmental arrest and impaired lung function. Conventional clinical methods for assessing the prenatal lung are not adequate for the detection and assessment of long-term health risks in infants with BPD, highlighting the need for a noninvasive tool for the characterization of lung microstructure and function. Theoretical diffusion models, like the model of xenon exchange (MOXE), interrogate alveolar gas exchange by predicting the uptake of inert hyperpolarized (HP) 129Xe gas measured with HP 129Xe magnetic resonance spectroscopy (MRS). To investigate HP 129Xe MRS as a tool for noninvasive characterization of pulmonary microstructural and functional changes in vivo, HP 129Xe gas exchange data were acquired in an oxygen exposure rat model of BPD that recapitulates the fewer and larger distal airways and pulmonary vascular stunting characteristics of BPD. Gas exchange parameters from MOXE, including airspace mean chord length ( Lm), apparent hematocrit in the pulmonary capillaries (HCT), and pulmonary capillary transit time ( tx), were compared with airspace mean axis length and area density (MAL and ρA) and percentage area of tissue and air (PTA and PAA) from histology. Lm was significantly larger in the exposed rats ( P = 0.003) and correlated with MAL, ρA, PTA, and PAA (0.59<|ρ|x are also discussed. These findings support the use of HP 129Xe MRS for detecting fewer, enlarged distal airways in this rat model of BPD, and potentially in humans.
- 1 September 2021
- Published by American Physiological Society in American Journal of Physiology-Lung Cellular and Molecular Physiology
- Vol. 321 (3) , L507-L517
Hyperpolarized 129Xe magnetic resonance spectroscopy in a rat model of bronchopulmonary dysplasia
Premature infants often require mechanical ventilation and oxygen therapy, which can result in bronchopulmonary dysplasia (BPD), characterized by developmental arrest and impaired lung function. Conventional clinical methods for assessing the prenatal lung are not adequate for the detection and assessment of long-term health risks in infants with BPD, highlighting the need for a noninvasive tool for the characterization of lung microstructure and function. Theoretical diffusion models, like the model of xenon exchange (MOXE), interrogate alveolar gas exchange by predicting the uptake of inert hyperpolarized (HP) 129Xe gas measured with HP 129Xe magnetic resonance spectroscopy (MRS). To investigate HP 129Xe MRS as a tool for noninvasive characterization of pulmonary microstructural and functional changes in vivo, HP 129Xe gas exchange data were acquired in an oxygen exposure rat model of BPD that recapitulates the fewer and larger distal airways and pulmonary vascular stunting characteristics of BPD. Gas exchange parameters from MOXE, including airspace mean chord length ( Lm), apparent hematocrit in the pulmonary capillaries (HCT), and pulmonary capillary transit time ( tx), were compared with airspace mean axis length and area density (MAL and ρA) and percentage area of tissue and air (PTA and PAA) from histology. Lm was significantly larger in the exposed rats ( P = 0.003) and correlated with MAL, ρA, PTA, and PAA (0.59<|ρ|x are also discussed. These findings support the use of HP 129Xe MRS for detecting fewer, enlarged distal airways in this rat model of BPD, and potentially in humans.
- 9 December 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (1) , 52-60
Chemical shift of 129Xe dissolved in red blood cells: Application to a rat model of bronchopulmonary dysplasia
Purpose: To measure the chemical shift of hyperpolarized 129Xe dissolved in the red blood cells(δRBC) of a cohort of rats exposed to hyperoxia and intermittent hypoxia (IH) to mimic human bronchopulmonary dysplasia, and to investigate the effect of xenon‐blood distribution time on δRBC.Methods: δRBC was measured from spectra acquired using a chemical shift saturation recovery sequence from 15 Sprague‐Dawley rats exposed to hyperoxia‐IH and 10 age‐matched control rats. Sensitization to the xenon‐blood distribution time was achieved by varying the time between saturation pulses, τ. δRBC was compared with blood fraction measured by histology of the cohort and blood oxygenation measured directly using pulse oximetry following a hypoxic challenge in an identically exposed cohort.Results: The mean δRBC in the hyperoxia‐IH exposed rats was 0.55 ± 0.04 ppm lower than that of the healthy cohort (P = .0038), and this difference did not depend on τ (P = .996). The blood fraction of the exposed cohort was lower than that of the healthy cohort (P = .0397). Oximetry measurements showed that the baseline arterial oxygen saturation (SaO2) of each cohort was not different (P = .72), but after a hypoxic challenge, the SaO2 of the exposed cohort was lower than that of the healthy cohort (P = .003).Conclusion: δRBC is reduced in rats exposed to hyperoxia‐IH compared with control rats. The change in δRBC is consistent with enhanced blood oxygen desaturation of the exposed cohort measured by pulse oximetry during a hypoxic challenge. This suggests that the observed change in δRBC reflects enhanced desaturation in the hyperoxia‐IH exposed cohort compared with the healthy cohort.
- 9 December 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (1) , 52-60
Chemical shift of 129Xe dissolved in red blood cells: Application to a rat model of bronchopulmonary dysplasia
Purpose: To measure the chemical shift of hyperpolarized 129Xe dissolved in the red blood cells(δRBC) of a cohort of rats exposed to hyperoxia and intermittent hypoxia (IH) to mimic human bronchopulmonary dysplasia, and to investigate the effect of xenon‐blood distribution time on δRBC.Methods: δRBC was measured from spectra acquired using a chemical shift saturation recovery sequence from 15 Sprague‐Dawley rats exposed to hyperoxia‐IH and 10 age‐matched control rats. Sensitization to the xenon‐blood distribution time was achieved by varying the time between saturation pulses, τ. δRBC was compared with blood fraction measured by histology of the cohort and blood oxygenation measured directly using pulse oximetry following a hypoxic challenge in an identically exposed cohort.Results: The mean δRBC in the hyperoxia‐IH exposed rats was 0.55 ± 0.04 ppm lower than that of the healthy cohort (P = .0038), and this difference did not depend on τ (P = .996). The blood fraction of the exposed cohort was lower than that of the healthy cohort (P = .0397). Oximetry measurements showed that the baseline arterial oxygen saturation (SaO2) of each cohort was not different (P = .72), but after a hypoxic challenge, the SaO2 of the exposed cohort was lower than that of the healthy cohort (P = .003).Conclusion: δRBC is reduced in rats exposed to hyperoxia‐IH compared with control rats. The change in δRBC is consistent with enhanced blood oxygen desaturation of the exposed cohort measured by pulse oximetry during a hypoxic challenge. This suggests that the observed change in δRBC reflects enhanced desaturation in the hyperoxia‐IH exposed cohort compared with the healthy cohort.