MRMalte Riedel

Malte Riedel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Malte Riedel has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Servo Navigation and Phase Equalization Enhanced by Run‐Time Stabilization (PEERS) for 3D EPI Time Series

    by Malte Riedel, Thomas Ulrich, Samuel Bianchi, Klaas P. Pruessmann

    Purpose: To enhance time‐resolved segmented imaging by synergy of run‐time stabilization and retrospective data‐driven phase correction. Methods: A segmented 3D EPI sequence for fMRI time series is equipped with servo navigation based on short orbital navigators and a linear perturbation model, enabling run‐time correction for rigid‐body motion, bulk phase, and frequency fluctuations. Complementary retrospective phase correction is based on the repetitive structure of the time series and serves to address residual phase and frequency offsets. The combined approach is termed phase equalization enhanced by run‐time stabilization (PEERS). Results: The proposed methods are assessed in terms of resulting alignment and tSNR of 3D EPI time series in a phantom and in vivo. Servo navigation is found to diminish motion confound in raw data and maintain k‐space consistency over time series. Coarse frequency tracking based on short navigators is supplemented by precise shot‐wise frequency and phase correction using retrospective phase equalization of EPI data. Relative to conventional volume realignment, PEERS achieved tSNR improvements of up to for small motion and on the order of when volunteers tried to hold still. Conclusion: Servo navigation achieves high‐precision run‐time motion correction for 3D EPI and is synergistic with retrospective phase equalization. Fully automatic and self‐calibrated, PEERS offers effective plug‐and‐play motion and phase correction for stabilized 3D EPI time series. The translation of stability gains into metrics of functional sensitivity is complex and must be studied with suitable statistical power. The data obtained in this work does not support any conclusions in this regard.

  • Open Access

    Human fMRI at 11.7T: Assessing Feasibility, Stability, and Reliability on the Iseult Scanner

    by Joseph Obriot, Zaineb Amor, Matthias Serger, Rüdiger Stirnberg, Philipp Ehses, Malte Riedel, Tony Stöcker, Klass P Prüssmann, Shajan Gunamony, Son Chu, et al.

    Ultra-high-field MRI promises major gains in BOLD sensitivity but introduces severe challenges such as RF field inhomogeneity, B0 field inhomogeneity, motion and vibration-induced field variations. We report the first whole-brain resting-state and task-based fMRI experiments at 11.7T. A 3D-EPI sequence was optimized using tailored parallel-transmit RF pulses, gradient reshaping to suppress vibration-induced B0 fluctuations, and prospective motion correction using servo navigation combined with retrospective phase equalization (PEERS). Four participants were scanned at 11.7T with whole-brain 1.2 mm isotropic resolution with servo navigation and PEERS that considerably reduced residual motion and increased temporal SNR. The Default Mode Network in resting state could be detected and a physiological-noise-dominated regime was identified. Four additional but different participants were scanned at 7T for tSNR comparison and validation of the protocol, data quality and processing pipeline. Task-based fMRI likewise was conducted at 11.7T and yielded robust, spatially specific activations across motor, visual, mathematical, and language networks, again with improved sensitivity and cleaner BOLD responses when using servo navigation and PEERS. These results demonstrate the feasibility and reliability of whole-brain human fMRI at 11.7T and constitute a first quality control milestone to further increase resolution at that field strength.

  • Open Access

    Motion‐ and Field‐Robust Mesoscopic Whole‐Brain T2*‐Weighted Imaging at 7 and 11.7 T Using Servo Navigation

    by Matthias Serger, Rüdiger Stirnberg, Philipp Ehses, Malte Riedel, Thomas Ulrich, Caroline Le Ster, Franck Mauconduit, Vincent Gras, Alexis Amadon, Alexandre Vignaud, et al.

    Purpose: To mitigate artifacts related to motion and field changes in high‐resolution ‐weighted human brain imaging using servo navigation at ultra‐high fields up to 11.7 T. Methods: MR‐based servo navigators were integrated into a segmented 3D‐EPI sequence to allow for prospective correction of involuntary head motion and first‐order shim changes. Seven subjects were scanned with whole‐brain protocols at 0.3 mm isotropic resolution with and without correction at 7 and 11.7 T. Validation was performed on detailed brain vasculature in scans with involuntary motion. Results: Blurring of small veins was reduced by servo navigation for all subjects and across field strengths. In case of involuntary large motion, the method preserved image quality, while uncorrected motion led to severe artifacts. In case of microscopic motion, reduced blurring and shading in the frontal lobe demonstrate the additional benefit of prospective field drift correction. Conclusion: Servo‐navigated segmented 3D‐EPI improves 0.3 mm isotropic whole‐brain ‐weighted imaging under realistic motion and field changes within 5.5 to 11 min scan time at 11.7 and 7 T.


  • Open Access

    Run‐time motion and first‐order shim control by expanded servo navigation

    by Malte Riedel, Thomas Ulrich, Klaas P. Pruessmann

    Purpose To provide a navigator-based run-time motion and first-order field correction for three-dimensional human brain imaging with high precision, minimal calibration and acquisition, and fast processing. Methods A complex-valued linear perturbation model with feedback control is extended to estimate and correct for gradient shim fields using orbital navigators (2.3 ms). Two approaches for sensitizing the model to gradient fields are presented, one based on finite differences with three additional navigators, and another projection-based approximation requiring no additional navigators. A mechanism for noise decorrelation of the matrix and the data is proposed and evaluated to reduce unwanted parameter biases. Results The rigid motion and first-order field control achieves robust motion and gradient shim corrections improving image quality in a series of phantom and in vivo experiments with varying field conditions. In phantom scans, magnet drifts, forced gradient field perturbations and field distortions from shifts of a second bottle phantom are successfully corrected. Field estimates of the magnet drifts are in good agreement with concurrent field probe measurements. For in vivo scans, the proposed method mitigates field variations from torso motions while being robust to head motion. In vivo gradient field precisions were 30   nT / m $$ 30\;\mathrm{nT}/\mathrm{m} $$ along with single-digit micrometer and millidegree rigid precisions. Conclusion The navigator-based method achieves accurate, high-precision run-time motion and field corrections with low sequence impact and calibration requirements.


  • Open Access

    Servo navigators: Linear regression and feedback control for rigid‐body motion correction

    by Thomas Ulrich, Malte Riedel, Klaas P. Pruessmann

    Purpose: Navigator‐based correction of rigid‐body motion reconciling high precision with minimal acquisition, minimal calibration and simple, fast processing.Methods: A short orbital navigator (2.3 ms) is inserted in a three‐dimensional (3D) gradient echo sequence for human head imaging. Head rotation and translation are determined by linear regression based on a complex‐valued model built either from three reference navigators or in a reference‐less fashion, from the first actual navigator. Optionally, the model is expanded by global phase and field offset. Run‐time scan correction on this basis establishes servo control that maintains validity of the linear picture by keeping its expansion point stable in the head frame of reference. The technique is assessed in a phantom and demonstrated by motion‐corrected imaging in vivo.Results: The proposed approach is found to establish stable motion control both with and without reference acquisition. In a phantom, it is shown to accurately detect motion mimicked by rotation of scan geometry as well as change in global B0. It is demonstrated to converge to accurate motion estimates after perturbation well beyond the linear signal range. In vivo, servo navigation achieved motion detection with precision in the single‐digit range of micrometers and millidegrees. Involuntary and intentional motion in the range of several millimeters were successfully corrected, achieving excellent image quality.Conclusion: The combination of linear regression and feedback control enables prospective motion correction for head imaging with high precision and accuracy, short navigator readouts, fast run‐time computation, and minimal demand for reference data.


  • Open Access

    Structured low‐rank reconstruction for navigator‐free water/fat separated multi‐shot diffusion‐weightedEPI

    by Yiming Dong, Kirsten Koolstra, Ziyu Li, Malte Riedel, Matthias J. P. van Osch, Peter Börnert

    Purpose: Multi‐shot diffusion‐weighted EPI allows an increase in image resolution and reduced geometric distortions and can be combined with chemical‐shift encoding (Dixon) to separate water/fat signals. However, such approaches suffer from physiological motion‐induced shot‐to‐shot phase variations. In this work, a structured low‐rank‐based navigator‐free algorithm is proposed to address the challenge of simultaneously separating water/fat signals and correcting for physiological motion‐induced shot‐to‐shot phase variations in multi‐shot EPI‐based diffusion‐weighted MRI.Theory and Methods: We propose an iterative, model‐based reconstruction pipeline that applies structured low‐rank regularization to estimate and eliminate the shot‐to‐shot phase variations in a data‐driven way, while separating water/fat images. The algorithm is tested in different anatomies, including head–neck, knee, brain, and prostate. The performance is validated in simulations and in‐vivo experiments in comparison to existing approaches.Results: In‐vivo experiments and simulations demonstrated the effectiveness of the proposed algorithm compared to extra‐navigated and an alternative self‐navigation approach. The proposed algorithm demonstrates the capability to reconstruct in the multi‐shot/Dixon hybrid space domain under‐sampled datasets, using the same number of acquired EPI shots compared to conventional fat‐suppression techniques but eliminating fat signals through chemical‐shift encoding. In addition, partial Fourier reconstruction can also be achieved by using the concept of virtual conjugate coils in conjunction with the proposed algorithm.Conclusion: The proposed algorithm effectively eliminates the shot‐to‐shot phase variations and separates water/fat images, making it a promising solution for future DWI on different anatomies.


  • Open Access

    Regularized joint water–fat separation with B0 map estimation in image space for 2D‐navigated interleaved EPI based diffusion MRI

    by Yiming Dong, Kirsten Koolstra, Malte Riedel, Matthias J. P. van Osch, Peter Börnert

    Purpose: To develop a new water–fat separation and B0 estimation algorithm to effectively suppress the multiple resonances of fat signal in EPI. This is especially relevant for DWI where fat is often a confounding factor.Methods: Water–fat separation based on chemical‐shift encoding enables robust fat suppression in routine MRI. However, for EPI the different chemical‐shift displacements of the multiple fat resonances along the phase‐encoding direction can be problematic for conventional separation algorithms. This work proposes a suitable model approximation for EPI under B0 and fat off‐resonance effects, providing a feasible multi‐peak water–fat separation algorithm. Simulations were performed to validate the algorithm. In vivo validation was performed in 6 volunteers, acquiring spin‐echo EPI images in the leg (B0 homogeneous) and head‐neck (B0 inhomogeneous) regions, using a TE‐shifted interleaved EPI sequence with/without diffusion sensitization. The results are numerically and statistically compared with voxel‐independent water–fat separation and fat saturation techniques to demonstrate the performance of the proposed algorithm.Results: The reference separation algorithm without the proposed spatial shift correction caused water–fat ambiguities in simulations and in vivo experiments. Some spectrally selective fat saturation approaches also failed to suppress fat in regions with severe B0 inhomogeneities. The proposed algorithm was able to achieve improved fat suppression for DWI data and ADC maps in the head–neck and leg regions.Conclusion: The proposed algorithm shows improved suppression of the multi‐peak fat components in multi‐shot interleaved EPI applications compared to the conventional fat saturation approaches and separation algorithms.


  • Open Access

    Segmented simultaneous multi‐slice diffusion‐weighted imaging with navigated 3D rigid motion correction

    by Malte Riedel (Né Steinhoff), Kawin Setsompop, Alfred Mertins, Peter Börnert

    Purpose: To improve the robustness of diffusion‐weighted imaging (DWI) data acquired with segmented simultaneous multi‐slice (SMS) echo‐planar imaging (EPI) against in‐plane and through‐plane rigid motion.Theory and Methods: The proposed algorithm incorporates a 3D rigid motion correction and wavelet denoising into the image reconstruction of segmented SMS‐EPI diffusion data. Low‐resolution navigators are used to estimate shot‐specific diffusion phase corruptions and 3D rigid motion parameters through SMS‐to‐volume registration. The shot‐wise rigid motion and phase parameters are integrated into a SENSE‐based full‐volume reconstruction for each diffusion direction. The algorithm is compared to a navigated SMS reconstruction without gross motion correction in simulations and in vivo studies with four‐fold interleaved 3‐SMS diffusion tensor acquisitions.Results: Simulations demonstrate high fidelity was achieved in the SMS‐to‐volume registration, with submillimeter registration errors and improved image reconstruction quality. In vivo experiments validate successful artifact reduction in 3D motion‐compromised in vivo scans with a temporal motion resolution of approximately 0.3 s.Conclusion: This work demonstrates the feasibility of retrospective 3D rigid motion correction from shot navigators for segmented SMS DWI.