Aarti A. Shenoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aarti A. Shenoy has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jeremy L. Gilbert
Department of Bioengineering Clemson University Clemson SC USA
4 shared publications Douglas E. Padgett
2 shared publications- Timothy M. Wright
Hospital for Special Surgery, New York, NY
2 shared publications Alberto V. Carli
Hospital for Special Surgery, Adult Reconstruction and Joint Replacement, New York, New York
1 shared publication- Alberto V. Carli
Hospital for Special Surgery, New York, NY
1 shared publication Arthur L. Malkani
Department of Orthopaedic Surgery University of Louisville Louisville Kentucky USA
1 shared publication
Latest Publications
- Open Access
- 3 April 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (4) , e70198
Metal Fatigue Fracture After Revision Total Knee Arthroplasty: A Retrieval Analysis
Most revision total knee arthroplasty patients experience excellent clinical outcomes. However, case studies document rare occurrences of metal component fractures promoted by the high cycles and low stresses that occur during daily use. In vivo , the mechanism that initiates metal fatigue fracture remains unclear. To address this gap, we collected implants from two retrieval programs. We asked: (1) what is the role of implant fixation in promoting fatigue fracture? (2) within modular junctions, what damage modes are associated with crack initiation? (3) how do equiaxed Ti‐6Al‐4V and wrought CoCrMo microstructures influence crack propagation? First, we compared clinical data for n = 8 fracture and n = 489 stemmed revision patients. Then, we performed retrieval analysis, combining radiographs with scanning electron microscopy and X‐ray photoelectron spectroscopy. We found no differences in weight ( p = 0.07) or implantation time ( p = 0.10) when comparing revision and fracture cohorts. Radiographs of fractured components showed insufficient metaphyseal fixation at or near the stem's modular junction. At the taper interface, we identified Ti‐6Al‐4V thread wear and CoCrMo pitting. Sectioning near a Ti‐6Al‐4V crack initiation site revealed an oxidized interface and an intergranular corrosion attack. On the free surface, TiO increased ( p < 0.0001) and TiO 2 decreased ( p < 0.0001) after 20 min of sputter time. Fatigue cracks propagated through equiaxed Ti‐6Al‐4V and wrought CoCrMo grains. These data support a hypothesized mechanism where insufficient implant fixation with bone or cement promotes localized damage accumulation within the modular junction, fatigue crack initiation and subsequent fracture.
- 3 April 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (4) , e70198
Open AccessMetal Fatigue Fracture After Revision Total Knee Arthroplasty: A Retrieval Analysis
Most revision total knee arthroplasty patients experience excellent clinical outcomes. However, case studies document rare occurrences of metal component fractures promoted by the high cycles and low stresses that occur during daily use. In vivo , the mechanism that initiates metal fatigue fracture remains unclear. To address this gap, we collected implants from two retrieval programs. We asked: (1) what is the role of implant fixation in promoting fatigue fracture? (2) within modular junctions, what damage modes are associated with crack initiation? (3) how do equiaxed Ti‐6Al‐4V and wrought CoCrMo microstructures influence crack propagation? First, we compared clinical data for n = 8 fracture and n = 489 stemmed revision patients. Then, we performed retrieval analysis, combining radiographs with scanning electron microscopy and X‐ray photoelectron spectroscopy. We found no differences in weight ( p = 0.07) or implantation time ( p = 0.10) when comparing revision and fracture cohorts. Radiographs of fractured components showed insufficient metaphyseal fixation at or near the stem's modular junction. At the taper interface, we identified Ti‐6Al‐4V thread wear and CoCrMo pitting. Sectioning near a Ti‐6Al‐4V crack initiation site revealed an oxidized interface and an intergranular corrosion attack. On the free surface, TiO increased ( p < 0.0001) and TiO 2 decreased ( p < 0.0001) after 20 min of sputter time. Fatigue cracks propagated through equiaxed Ti‐6Al‐4V and wrought CoCrMo grains. These data support a hypothesized mechanism where insufficient implant fixation with bone or cement promotes localized damage accumulation within the modular junction, fatigue crack initiation and subsequent fracture.
- 2 February 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (2)
Implant Retrieval Analysis for Total Joint Arthroplasty: A Review
Joint replacement is one of the most successful complex surgical procedures, in large part due to innovations in implant materials and designs. Understanding how implants perform in vivo and why some fail has been crucial to continuous improvement. Analysis of implants retrieved at revision surgery can determine mechanisms driving both performance and failure and suggest necessary changes to address problems. Retrieval analysis can also serve as the earliest warning that an implant system has failed to meet expectations and that a regulatory recall may be the prudent decision. In this review, we provide a history of how retrieval analysis has been leveraged to provide mechanistic answers to design and material problems, to advance implant design and practice, and to provide warnings of early failures. We describe methods to conduct failure analysis of revised implants from subjective observations to quantitative techniques that span engineering, imaging, and pathology. We then present ways in which retrieval analysis has advanced biomaterials and design improvements using the development of polyethylene‐based materials and the discovery of implant tribocorrosion and subsequent mitigation strategies as examples. We also discuss how retrieval analysis was combined with finite element modeling in the evolution of four generations of knee implant design. Finally, we discuss how retrieval analysis can continue to be a valuable resource for joint replacement surgery and implant manufacturing.
- 2 February 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (2)
Implant Retrieval Analysis for Total Joint Arthroplasty: A Review
Joint replacement is one of the most successful complex surgical procedures, in large part due to innovations in implant materials and designs. Understanding how implants perform in vivo and why some fail has been crucial to continuous improvement. Analysis of implants retrieved at revision surgery can determine mechanisms driving both performance and failure and suggest necessary changes to address problems. Retrieval analysis can also serve as the earliest warning that an implant system has failed to meet expectations and that a regulatory recall may be the prudent decision. In this review, we provide a history of how retrieval analysis has been leveraged to provide mechanistic answers to design and material problems, to advance implant design and practice, and to provide warnings of early failures. We describe methods to conduct failure analysis of revised implants from subjective observations to quantitative techniques that span engineering, imaging, and pathology. We then present ways in which retrieval analysis has advanced biomaterials and design improvements using the development of polyethylene‐based materials and the discovery of implant tribocorrosion and subsequent mitigation strategies as examples. We also discuss how retrieval analysis was combined with finite element modeling in the evolution of four generations of knee implant design. Finally, we discuss how retrieval analysis can continue to be a valuable resource for joint replacement surgery and implant manufacturing.
- Open Access
- 16 January 2026
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 114 (1) , e70033
In Vivo Corrosion of Acetabular Modular Tapers Reduces Local Corrosion Resistance: Near‐Field Electrochemical Impedance Spectroscopy as an Indicator of the Type and Severity of Corrosion in Retrieved Hip Implants
Retrieved hip implant components experience a range of corrosion types and severity, often on small surface areas of the taper region. Tribocorrosion‐related damage within modular taper regions and resulting changes of the oxide‐covered surface can alter the local impedance of the interface. We hypothesize that near‐field electrochemical impedance spectroscopy (nfEIS), where local area impedance measurements can be made, can serve as an excellent method to distinguish different forms and severity of tribocorrosion degradation in localized regions of the implant surface. Impedance measurements can also help determine subsequent corrosion susceptibility. Recent studies have shown that EIS on a localized, or global basis, is a useful tool to ascertain the corrosion resistance and extent of oxide alteration in retrieved hip implant components. Hence, the goal of this study was to systematically assess different types of corrosion modes found on the modular taper surfaces of retrieved acetabular liners using nfEIS and to correlate the resulting local impedance response with visually identified different corrosion modes. Utilizing an easy‐to‐manufacture microelectrode on wrought CoCrMo liners, we found that local impedance measurements are a good indicator of differences it forms of corrosion‐related damage. nfEIS measurements captured damage‐specific differences in the impedance response that were unique to specific types and severity of corrosion. We could describe the surfaces in terms of equivalent circuit models consisting of resistive and capacitive (or constant phase) elements. Intergranular corrosion (IGC) and oxide deposits were found to match a coated model behavior, with a characteristic double‐hump phase angle response. Phase boundary corrosion (PBC) and control (polished CoCrMo disk) were found to match a constant‐phase‐element Randle's circuit model with a mostly intact surface and minimal to no material loss. We found that polarization resistance, where higher R p indicates greater corrosion resistance, correlated with the intactness of the surface: greater material loss on the surface translated to lower R p values (IGC sample R p = 8.46E6 Ω/cm 2 compared to PBC sample R p = 5.79E7 Ω/cm 2 ). Our findings demonstrate the versatility of this technique to analyze different types of retrieved device surfaces to make objective determinations in terms of the nature of the corrosion damage and the surface's continued corrosion susceptibility. Further developing this technique and testing it on a variety of tribocorrosion features and different biomedical alloys will help ascertain its applications in retrieval analysis and may assist in determining the extent of device damage at revision surgery.
- 16 January 2026
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 114 (1) , e70033
Open AccessIn Vivo Corrosion of Acetabular Modular Tapers Reduces Local Corrosion Resistance: Near‐Field Electrochemical Impedance Spectroscopy as an Indicator of the Type and Severity of Corrosion in Retrieved Hip Implants
Retrieved hip implant components experience a range of corrosion types and severity, often on small surface areas of the taper region. Tribocorrosion‐related damage within modular taper regions and resulting changes of the oxide‐covered surface can alter the local impedance of the interface. We hypothesize that near‐field electrochemical impedance spectroscopy (nfEIS), where local area impedance measurements can be made, can serve as an excellent method to distinguish different forms and severity of tribocorrosion degradation in localized regions of the implant surface. Impedance measurements can also help determine subsequent corrosion susceptibility. Recent studies have shown that EIS on a localized, or global basis, is a useful tool to ascertain the corrosion resistance and extent of oxide alteration in retrieved hip implant components. Hence, the goal of this study was to systematically assess different types of corrosion modes found on the modular taper surfaces of retrieved acetabular liners using nfEIS and to correlate the resulting local impedance response with visually identified different corrosion modes. Utilizing an easy‐to‐manufacture microelectrode on wrought CoCrMo liners, we found that local impedance measurements are a good indicator of differences it forms of corrosion‐related damage. nfEIS measurements captured damage‐specific differences in the impedance response that were unique to specific types and severity of corrosion. We could describe the surfaces in terms of equivalent circuit models consisting of resistive and capacitive (or constant phase) elements. Intergranular corrosion (IGC) and oxide deposits were found to match a coated model behavior, with a characteristic double‐hump phase angle response. Phase boundary corrosion (PBC) and control (polished CoCrMo disk) were found to match a constant‐phase‐element Randle's circuit model with a mostly intact surface and minimal to no material loss. We found that polarization resistance, where higher R p indicates greater corrosion resistance, correlated with the intactness of the surface: greater material loss on the surface translated to lower R p values (IGC sample R p = 8.46E6 Ω/cm 2 compared to PBC sample R p = 5.79E7 Ω/cm 2 ). Our findings demonstrate the versatility of this technique to analyze different types of retrieved device surfaces to make objective determinations in terms of the nature of the corrosion damage and the surface's continued corrosion susceptibility. Further developing this technique and testing it on a variety of tribocorrosion features and different biomedical alloys will help ascertain its applications in retrieval analysis and may assist in determining the extent of device damage at revision surgery.
- 22 November 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (2) , 127-133
Not All Antiseptic Solutions Are Equivalent in Removing Biofilm
Background: Antiseptic solutions are commonly utilized during total joint arthroplasty (TJA) to prevent and treat periprosthetic joint infection (PJI). The purpose of this study was to investigate which antiseptic solution is most effective against methicillin-sensitive Staphylococcus aureus (MSSA) and Escherichia coli biofilms established in vitro on orthopaedic surfaces commonly utilized in total knee arthroplasty: cobalt-chromium (CC), oxidized zirconium (OxZr), and polymethylmethacrylate (PMMA). Methods: MSSA and E. coli biofilms were grown on CC, OxZr, and PMMA discs for 24 and 72 hours. Biofilm-coated discs were treated with control or various antiseptic solutions for 3 minutes. Solutions included 10% povidone-iodine, a 1:1 mixture of 10% povidone-iodine plus 3% hydrogen peroxide, diluted povidone-iodine, 0.05% chlorhexidine gluconate, and a surfactant-based formulation of ethanol, acetic acid, sodium acetate, benzalkonium chloride, and water. Following treatment, discs were sonicated to quantify adherent bacteria or underwent imaging with scanning electron microscopy to identify biofilm. Antiseptic solutions were considered efficacious if they produced a 3-log (1,000-fold) reduction in colony-forming units compared with controls. Results: On both OxZr and CC, 10% povidone-iodine with hydrogen peroxide eradicated all MSSA, and it achieved clinical efficacy on PMMA at both 24-hour MSSA biofilm (p < 0.0002) and 72-hour MSSA biofilm (p = 0.002). On 72-hour MSSA biofilm, 10% povidone-iodine eradicated all bacteria on OxZr and CC, and it achieved clinical efficacy on PMMA (p = 0.04). On 24-hour MSSA biofilm, 10% povidone-iodine achieved efficacy on all surfaces (all p < 0.01). The surfactant-based formulation only achieved clinical efficacy on 72-hour MSSA biofilms on CC (p = 0.04) and OxZr (p = 0.07). On 72-hour E. coli biofilm, 10% povidone-iodine with or without hydrogen peroxide achieved clinical efficacy on all surfaces. No other solution achieved clinical efficacy on either MSSA or E. coli. Conclusions: Antiseptic solutions vary considerably in efficacy against bacterial biofilm. The 10% povidone-iodine solution with or without hydrogen peroxide consistently removed MSSA and E. coli biofilms on multiple orthopaedic surfaces and should be considered for clinical use. Clinical Relevance: Clinicians should be aware of the differences in the efficacy of antiseptic solutions on different orthopaedic surfaces when treating MSSA or E. coli biofilms.
- 22 November 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (2) , 127-133
Not All Antiseptic Solutions Are Equivalent in Removing Biofilm
Background: Antiseptic solutions are commonly utilized during total joint arthroplasty (TJA) to prevent and treat periprosthetic joint infection (PJI). The purpose of this study was to investigate which antiseptic solution is most effective against methicillin-sensitive Staphylococcus aureus (MSSA) and Escherichia coli biofilms established in vitro on orthopaedic surfaces commonly utilized in total knee arthroplasty: cobalt-chromium (CC), oxidized zirconium (OxZr), and polymethylmethacrylate (PMMA). Methods: MSSA and E. coli biofilms were grown on CC, OxZr, and PMMA discs for 24 and 72 hours. Biofilm-coated discs were treated with control or various antiseptic solutions for 3 minutes. Solutions included 10% povidone-iodine, a 1:1 mixture of 10% povidone-iodine plus 3% hydrogen peroxide, diluted povidone-iodine, 0.05% chlorhexidine gluconate, and a surfactant-based formulation of ethanol, acetic acid, sodium acetate, benzalkonium chloride, and water. Following treatment, discs were sonicated to quantify adherent bacteria or underwent imaging with scanning electron microscopy to identify biofilm. Antiseptic solutions were considered efficacious if they produced a 3-log (1,000-fold) reduction in colony-forming units compared with controls. Results: On both OxZr and CC, 10% povidone-iodine with hydrogen peroxide eradicated all MSSA, and it achieved clinical efficacy on PMMA at both 24-hour MSSA biofilm (p < 0.0002) and 72-hour MSSA biofilm (p = 0.002). On 72-hour MSSA biofilm, 10% povidone-iodine eradicated all bacteria on OxZr and CC, and it achieved clinical efficacy on PMMA (p = 0.04). On 24-hour MSSA biofilm, 10% povidone-iodine achieved efficacy on all surfaces (all p < 0.01). The surfactant-based formulation only achieved clinical efficacy on 72-hour MSSA biofilms on CC (p = 0.04) and OxZr (p = 0.07). On 72-hour E. coli biofilm, 10% povidone-iodine with or without hydrogen peroxide achieved clinical efficacy on all surfaces. No other solution achieved clinical efficacy on either MSSA or E. coli. Conclusions: Antiseptic solutions vary considerably in efficacy against bacterial biofilm. The 10% povidone-iodine solution with or without hydrogen peroxide consistently removed MSSA and E. coli biofilms on multiple orthopaedic surfaces and should be considered for clinical use. Clinical Relevance: Clinicians should be aware of the differences in the efficacy of antiseptic solutions on different orthopaedic surfaces when treating MSSA or E. coli biofilms.
- 1 July 2023
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 13 (3)
Failure of a Femoral Revision Knee Component with Chemical Corrosion and Elevated Metal Ions
Case: Failure of the modular junction in revision total knee arthroplasty is a rare complication. We report a patient with late, atraumatic failure of a modern, modular revision femoral component, with preoperative elevation of serum cobalt and chromium levels. Retrieval analysis showed extensive chemical corrosion. Conclusion: Failure of a modern, modular femoral component may cause metal synovitis and elevated serum metal levels. Subtle radiographic changes and preoperative serum metal levels may identify this complication.
- 1 July 2023
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 13 (3)
Failure of a Femoral Revision Knee Component with Chemical Corrosion and Elevated Metal Ions
Case: Failure of the modular junction in revision total knee arthroplasty is a rare complication. We report a patient with late, atraumatic failure of a modern, modular revision femoral component, with preoperative elevation of serum cobalt and chromium levels. Retrieval analysis showed extensive chemical corrosion. Conclusion: Failure of a modern, modular femoral component may cause metal synovitis and elevated serum metal levels. Subtle radiographic changes and preoperative serum metal levels may identify this complication.
- 23 April 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 38 (7) , S274-S279
Evaluation of Mechanically-Assisted Crevice Corrosion of Different Modular Dual Mobility Constructs
- 23 April 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 38 (7) , S274-S279
Evaluation of Mechanically-Assisted Crevice Corrosion of Different Modular Dual Mobility Constructs
- 21 February 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 38 (6) , S363-S367
Clinical and Biomechanical Characteristics of Posterior-Stabilized Polyethylene Post Fractures in Total Knee Arthroplasty: A Retrieval Analysis
- 21 February 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 38 (6) , S363-S367
Clinical and Biomechanical Characteristics of Posterior-Stabilized Polyethylene Post Fractures in Total Knee Arthroplasty: A Retrieval Analysis
- 21 January 2020
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 6 (3) , 1344-1354
Sensing Localized Surface Corrosion Damage of CoCrMo Alloys and Modular Tapers of Total Hip Retrievals Using Nearfield Electrochemical Impedance Spectroscopy
Wear and corrosion damage of biomedical alloys alters the structure and electrochemical properties of the surface heterogeneously. It was hypothesized that local regions on the same surface systematically differ from one another in terms of their impedance characteristics. To test this hypothesis, CoCrMo discs exposed to electrosurgical and inflammatory-species driven damage were characterized using a localized impedance technique, nearfield electrochemical impedance spectroscopy (NEIS), to assess point-specific surface integrity in response to applied damage. It was found that electrosurgical damage, as may arise during primary arthroplasty and revision surgeries, and hydrogen peroxide concentrations of 5-10 mM significantly alters the corrosion susceptibility of the local surface compared to the as-polished CoCrMo surface. A CoCrMo retrieved neck taper (Goldberg score of 4) was scored in different local regions based off of visual appearance, and it was found that there is a direct relationship between increasing debris coverage and decreasing impedance, with the global surface impedance closest to the most severe-scored local region. This non-invasive method, which uses a milli-electrode configuration to test localized regions, can measure the heterogeneous electrochemical impedance of an implant surface, and be tailored to assess specific damage and corrosion mechanisms revealed on retrieval surfaces.
- 21 January 2020
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 6 (3) , 1344-1354
Sensing Localized Surface Corrosion Damage of CoCrMo Alloys and Modular Tapers of Total Hip Retrievals Using Nearfield Electrochemical Impedance Spectroscopy
Wear and corrosion damage of biomedical alloys alters the structure and electrochemical properties of the surface heterogeneously. It was hypothesized that local regions on the same surface systematically differ from one another in terms of their impedance characteristics. To test this hypothesis, CoCrMo discs exposed to electrosurgical and inflammatory-species driven damage were characterized using a localized impedance technique, nearfield electrochemical impedance spectroscopy (NEIS), to assess point-specific surface integrity in response to applied damage. It was found that electrosurgical damage, as may arise during primary arthroplasty and revision surgeries, and hydrogen peroxide concentrations of 5-10 mM significantly alters the corrosion susceptibility of the local surface compared to the as-polished CoCrMo surface. A CoCrMo retrieved neck taper (Goldberg score of 4) was scored in different local regions based off of visual appearance, and it was found that there is a direct relationship between increasing debris coverage and decreasing impedance, with the global surface impedance closest to the most severe-scored local region. This non-invasive method, which uses a milli-electrode configuration to test localized regions, can measure the heterogeneous electrochemical impedance of an implant surface, and be tailored to assess specific damage and corrosion mechanisms revealed on retrieval surfaces.
- 5 December 2019
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (5) , 1089-1100
In vitro test methods for seating and fretting corrosion behavior of modular metal‐on‐metal acetabular tapers
Retrieval studies show that metal‐on‐metal acetabular shell‐liner tapers are susceptible to corrosion, which is hypothesized to arise from mechanically‐assisted crevice corrosion (MACC). The role of materials on MACC of acetabular tapers has not been previously studied. In vitro tests of seating, pushout, and fretting corrosion performance of acetabular tapers are presented to assess the role of material combinations (Ti–6Al–4V shells, HC CoCrMo, LC CoCrMo, and 316L SS liners). The acetabular tapers were wet‐assembled to a seating load of 1,000 N. The liner load–displacement seating mechanics were measured. Fretting corrosion currents were evaluated using a uniaxial incremental cyclic compression test up to 4,000 N, with the load applied at a 55° angle to the taper interface. Fretting currents, fretting onset loads, taper disengagement strength were measured and load–displacement plots were obtained. Pushout tests were also performed pre‐ and post‐fretting corrosion. The average liner seating displacements varied from 134 to 226 μm across groups. Fretting currents at 3,600 N cyclic load were low and ranged between 0.05 and 0.27 μA and were independent of material combination (p > 0.05), reflecting small amounts of fretting. Fretting corrosion onset loads were between 1,800 and 2,100 N, and did not differ across groups (p > 0.05). Pushout loads were 27–43% of the maximum load applied. Fretting corrosion levels were very low for all material combinations and not different from one another. The seating and pushout responses were also not material dependent. The low fretting currents measured imply that MACC may not be a major cause for acetabular taper corrosion. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:00‐111089, 2020
- 5 December 2019
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 38 (5) , 1089-1100
In vitro test methods for seating and fretting corrosion behavior of modular metal‐on‐metal acetabular tapers
Retrieval studies show that metal‐on‐metal acetabular shell‐liner tapers are susceptible to corrosion, which is hypothesized to arise from mechanically‐assisted crevice corrosion (MACC). The role of materials on MACC of acetabular tapers has not been previously studied. In vitro tests of seating, pushout, and fretting corrosion performance of acetabular tapers are presented to assess the role of material combinations (Ti–6Al–4V shells, HC CoCrMo, LC CoCrMo, and 316L SS liners). The acetabular tapers were wet‐assembled to a seating load of 1,000 N. The liner load–displacement seating mechanics were measured. Fretting corrosion currents were evaluated using a uniaxial incremental cyclic compression test up to 4,000 N, with the load applied at a 55° angle to the taper interface. Fretting currents, fretting onset loads, taper disengagement strength were measured and load–displacement plots were obtained. Pushout tests were also performed pre‐ and post‐fretting corrosion. The average liner seating displacements varied from 134 to 226 μm across groups. Fretting currents at 3,600 N cyclic load were low and ranged between 0.05 and 0.27 μA and were independent of material combination (p > 0.05), reflecting small amounts of fretting. Fretting corrosion onset loads were between 1,800 and 2,100 N, and did not differ across groups (p > 0.05). Pushout loads were 27–43% of the maximum load applied. Fretting corrosion levels were very low for all material combinations and not different from one another. The seating and pushout responses were also not material dependent. The low fretting currents measured imply that MACC may not be a major cause for acetabular taper corrosion. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:00‐111089, 2020