Sjoerd Stallinga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sjoerd Stallinga has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
- Bernd Rieger
Department of Imaging Physics, Delft University of Technology, Delft, the Netherlands
30 shared publications Bernd Rieger
Department of Imaging Physics, Delft University of Technology, The Netherlands
8 shared publications- Christiaan Nick Hulleman
Delft University of Technology
6 shared publications - Lucas J. van Vliet
Quantitative Imaging Group, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands
6 shared publications - David Grunwald
RNA Therapeutics Institute, UMass Chan Medical School, Worcester, MA, USA
5 shared publications - Florian Schueder
Institute of Bioengineering (IBI), École Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
4 shared publications
Latest Publications
- Open Access
- 24 June 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (24)
Exploring nanographene for single molecule imaging at cryogenic temperatures
Imaging single fluorescent molecules at cryogenic temperatures can increase photon budgets by suppressing photobleaching and non-radiative loss. Combined with rapid-freezing vitrification, it enables correlative cryo-fluorescence and electron microscopy. Obtaining a wide set of fluorophores with suitable blinking characteristics at cryogenic temperatures has remained a challenge. Nanographenes are self-blinking fluorophores that could fill this gap, yet their low-temperature intermittency remains largely unquantified. Here, we characterize the blinking and photon output of single dibenzo[hi,st]ovalene (DBOV-azide) nanographene fluorophores on glass from 91 to 293 K over excitation irradiances of 1.2–5.9 kW cm−2. On/off fluorescence states are extracted from wide-field images using a generalized likelihood ratio test, with simulation-based validation to reduce false detections under high-background conditions. We find that DBOV-azide blinks at all temperatures, with mean on-times that decrease with increasing temperature (longer at 91 K than at room temperature) and that further shorten with increasing irradiance at 91 K. For short time scales (t < 1.5 s), on- and off-time distributions follow power laws with exponents −1.6 to −1.2 that show no systematic dependence on temperature or irradiance. The mean on/off ratio drops by ∼10× from 91 to 293 K, indicating a worse duty cycle at lower temperature. Photon output increases with irradiance and is higher at cryogenic temperatures, with an order-of-magnitude increase in photons per on-event compared to room temperature.
- 24 June 2026
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 164 (24)
Open AccessExploring nanographene for single molecule imaging at cryogenic temperatures
Imaging single fluorescent molecules at cryogenic temperatures can increase photon budgets by suppressing photobleaching and non-radiative loss. Combined with rapid-freezing vitrification, it enables correlative cryo-fluorescence and electron microscopy. Obtaining a wide set of fluorophores with suitable blinking characteristics at cryogenic temperatures has remained a challenge. Nanographenes are self-blinking fluorophores that could fill this gap, yet their low-temperature intermittency remains largely unquantified. Here, we characterize the blinking and photon output of single dibenzo[hi,st]ovalene (DBOV-azide) nanographene fluorophores on glass from 91 to 293 K over excitation irradiances of 1.2–5.9 kW cm−2. On/off fluorescence states are extracted from wide-field images using a generalized likelihood ratio test, with simulation-based validation to reduce false detections under high-background conditions. We find that DBOV-azide blinks at all temperatures, with mean on-times that decrease with increasing temperature (longer at 91 K than at room temperature) and that further shorten with increasing irradiance at 91 K. For short time scales (t < 1.5 s), on- and off-time distributions follow power laws with exponents −1.6 to −1.2 that show no systematic dependence on temperature or irradiance. The mean on/off ratio drops by ∼10× from 91 to 293 K, indicating a worse duty cycle at lower temperature. Photon output increases with irradiance and is higher at cryogenic temperatures, with an order-of-magnitude increase in photons per on-event compared to room temperature.
- Open Access
- 11 June 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (12) , 22940
Generalized low-pass filtering in structured illumination microscopy and spatial domain reconstructions with high signal-to-noise ratio
Structured illumination microscopy (SIM) is a technique that employs non-uniform illumination to shift spatial frequencies that are normally unobservable into the non-zero region of the optical transfer function (OTF). Several differently illuminated images are combined to reconstruct these high spatial frequencies, yielding an up to two-fold increase in resolution beyond the diffraction limit. The reconstruction quality is affected by the noise level which depends on the specific procedure. In this work, we show that least-squares Fourier domain reconstruction results in the best possible theoretically achievable SSNR and thus can serve as a metric for reconstruction quality. We consider, in a general manner, how the choice of low-pass filtering in the reconstruction procedure affects the spectral signal-to-noise ratio (SSNR) in the reconstructed image. Finally, we present fast real-space reconstruction procedures that demonstrate near-optimal noise performance.
- 11 June 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (12) , 22940
Open AccessGeneralized low-pass filtering in structured illumination microscopy and spatial domain reconstructions with high signal-to-noise ratio
Structured illumination microscopy (SIM) is a technique that employs non-uniform illumination to shift spatial frequencies that are normally unobservable into the non-zero region of the optical transfer function (OTF). Several differently illuminated images are combined to reconstruct these high spatial frequencies, yielding an up to two-fold increase in resolution beyond the diffraction limit. The reconstruction quality is affected by the noise level which depends on the specific procedure. In this work, we show that least-squares Fourier domain reconstruction results in the best possible theoretically achievable SSNR and thus can serve as a metric for reconstruction quality. We consider, in a general manner, how the choice of low-pass filtering in the reconstruction procedure affects the spectral signal-to-noise ratio (SSNR) in the reconstructed image. Finally, we present fast real-space reconstruction procedures that demonstrate near-optimal noise performance.
- Open Access
- 15 May 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (6) , 2999-3015
Application of gradient-consensus Richardson–Lucy deconvolution to noisy undersampled brightfield microscopy data
The gradient-consensus Richardson–Lucy (GC-RL) deconvolution algorithm is a novel approach to contrast restoration in high-resolution microscopy imaging without excessive noise amplification. We evaluate this method in this work, focusing on the impact of the noise level of the input image, of imperfections and deviations in image formation from the ideal incoherent case, and of using undersampled input data. The gain in spectral signal to noise ratio (SSNR) is larger when the noise level of the raw image is lower. We also find a positive impact on SSNR gain from using an optical transfer function (OTF) in the deconvolution that has a decreased spatial frequency response compared to the ideal incoherent OTF. A simple upsampling scheme, embedded in the GC-RL deconvolution, is demonstrated to be suitable for undersampled data. We show our results on simulated data, on fluorescence microscopy data, and on brightfield microscopy data of a breast tumour section. The GC-RL method has potential for whole slide imaging technology to retrieve diagnostically relevant image features at the smallest length scales from scanned images at lower resolution, providing a gain in throughput and data storage requirements.
- 15 May 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (6) , 2999-3015
Open AccessApplication of gradient-consensus Richardson–Lucy deconvolution to noisy undersampled brightfield microscopy data
The gradient-consensus Richardson–Lucy (GC-RL) deconvolution algorithm is a novel approach to contrast restoration in high-resolution microscopy imaging without excessive noise amplification. We evaluate this method in this work, focusing on the impact of the noise level of the input image, of imperfections and deviations in image formation from the ideal incoherent case, and of using undersampled input data. The gain in spectral signal to noise ratio (SSNR) is larger when the noise level of the raw image is lower. We also find a positive impact on SSNR gain from using an optical transfer function (OTF) in the deconvolution that has a decreased spatial frequency response compared to the ideal incoherent OTF. A simple upsampling scheme, embedded in the GC-RL deconvolution, is demonstrated to be suitable for undersampled data. We show our results on simulated data, on fluorescence microscopy data, and on brightfield microscopy data of a breast tumour section. The GC-RL method has potential for whole slide imaging technology to retrieve diagnostically relevant image features at the smallest length scales from scanned images at lower resolution, providing a gain in throughput and data storage requirements.
- Open Access
- 13 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 10385
Absorption dipole effects on MINFLUX single molecule localization
Single-molecule fluorescence localization with minimum photon flux imaging (MINFLUX) can achieve localization precisions in the small nanometer range or better under suitable conditions. Potentially adverse conditions, such as a fixed fluorescence dipole or optical aberrations, that could cause systematic localization errors, have received little attention up to now. Here, we study these effects in simulation. We find that biases occur for fluorophores with a fixed absorption dipole tilted out of the imaging plane. These become larger (up to about 25% of the diameter of the circle spanned by the doughnut center positions), the larger the tilt angle gets. As a rule of thumb, the spread in bias is smaller than 5 nm in case the dipole orientation is less than 30° out of plane for the typical case of a doughnut probing circle of diameter 100 nm. For freely rotating dipoles, only the primary aberrations, astigmatism and coma, contribute to bias. This bias depends on the position of the fluorophore inside the circular probing area of MINFLUX and can be significantly larger than the localization precision. We show that increasing the number of measurements over the circle from a triangular to a hexagonal pattern is beneficial for reducing bias in all cases. Iterative shrinking of the probing area can eliminate the position-dependent bias completely, but a strong dependence on dipole orientation of the bias at the center of the probing area remains.
- 13 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 10385
Open AccessAbsorption dipole effects on MINFLUX single molecule localization
Single-molecule fluorescence localization with minimum photon flux imaging (MINFLUX) can achieve localization precisions in the small nanometer range or better under suitable conditions. Potentially adverse conditions, such as a fixed fluorescence dipole or optical aberrations, that could cause systematic localization errors, have received little attention up to now. Here, we study these effects in simulation. We find that biases occur for fluorophores with a fixed absorption dipole tilted out of the imaging plane. These become larger (up to about 25% of the diameter of the circle spanned by the doughnut center positions), the larger the tilt angle gets. As a rule of thumb, the spread in bias is smaller than 5 nm in case the dipole orientation is less than 30° out of plane for the typical case of a doughnut probing circle of diameter 100 nm. For freely rotating dipoles, only the primary aberrations, astigmatism and coma, contribute to bias. This bias depends on the position of the fluorophore inside the circular probing area of MINFLUX and can be significantly larger than the localization precision. We show that increasing the number of measurements over the circle from a triangular to a hexagonal pattern is beneficial for reducing bias in all cases. Iterative shrinking of the probing area can eliminate the position-dependent bias completely, but a strong dependence on dipole orientation of the bias at the center of the probing area remains.
- Open Access
Absorption dipole effects on MINFLUX single molecule localization
Single molecule fluorescence localization with minimum photon flux imaging (MINFLUX) can achieve localization precisions in the small nanometer range or better under suitable conditions. Potentially adverse conditions, such as a fixed fluorescence dipole or optical aberrations, that could cause systematic localization errors, have received little attention up to now. Here, we study these effects in simulation. We find that biases occur for fluorophores with a fixed absorption dipole tilted out of the imaging plane. These become larger (up to about 25% of the diameter of the circle spanned by the doughnut center positions) the larger the tilt angle gets. As a rule of thumb the spread in bias is smaller than 5 nm in case the dipole orientation is less than 30° out of plane for the typical case of a doughnut probing circle of diameter 100 nm. For freely rotating dipoles only the primary aberrations astigmatism and coma contribute to bias. This bias depends on the position of the fluorophore inside the circular probing area of MINFLUX and can be significantly larger than the localization precision. We show that increasing the number of measurements over the circle from a triangular to a hexagonal pattern is beneficial for reducing bias in all cases. Iterative shrinking of the probing area can eliminate the position dependent bias completely, but a strong dependence on dipole orientation of the bias at the center of the probing area remains.
Open AccessAbsorption dipole effects on MINFLUX single molecule localization
Single molecule fluorescence localization with minimum photon flux imaging (MINFLUX) can achieve localization precisions in the small nanometer range or better under suitable conditions. Potentially adverse conditions, such as a fixed fluorescence dipole or optical aberrations, that could cause systematic localization errors, have received little attention up to now. Here, we study these effects in simulation. We find that biases occur for fluorophores with a fixed absorption dipole tilted out of the imaging plane. These become larger (up to about 25% of the diameter of the circle spanned by the doughnut center positions) the larger the tilt angle gets. As a rule of thumb the spread in bias is smaller than 5 nm in case the dipole orientation is less than 30° out of plane for the typical case of a doughnut probing circle of diameter 100 nm. For freely rotating dipoles only the primary aberrations astigmatism and coma contribute to bias. This bias depends on the position of the fluorophore inside the circular probing area of MINFLUX and can be significantly larger than the localization precision. We show that increasing the number of measurements over the circle from a triangular to a hexagonal pattern is beneficial for reducing bias in all cases. Iterative shrinking of the probing area can eliminate the position dependent bias completely, but a strong dependence on dipole orientation of the bias at the center of the probing area remains.
- Open Access
- 27 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 10689
Smart 3D super-resolution microscopy reveals the architecture of the RNA scaffold in a nuclear body
Small subcellular organelles orchestrate key cellular functions. How biomolecules are spatially organized within these assemblies is poorly understood. Here, we report an automated super-resolution imaging and analysis workflow that integrates confocal microscopy, morphological object screening, targeted 3D super-resolution STED microscopy and quantitative image analysis. Using this smart microscopy workflow, we target the 3D organization of NEAT1 , an architectural RNA that constitutes the structural backbone of paraspeckles, a membraneless nuclear organelle. Using site-specific labeling, morphological sorting and particle averaging, we reconstruct the morphological space of paraspeckles along their development cycle from over 10,000 individual particles. Applying spherical harmonics analysis, we report so-far unknown heterotypes of NEAT1 RNA organization. By integrating multi-positional labeling, we determine the coarse conformation of NEAT1 within the organelle and show that the 3’ end forms a loop-like structure at the surface of the paraspeckle. Our study reveals key structural features of paraspeckle structure and growth, as well as the molecular organization of its scaffolding RNA.
- 27 November 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 10689
Open AccessSmart 3D super-resolution microscopy reveals the architecture of the RNA scaffold in a nuclear body
Small subcellular organelles orchestrate key cellular functions. How biomolecules are spatially organized within these assemblies is poorly understood. Here, we report an automated super-resolution imaging and analysis workflow that integrates confocal microscopy, morphological object screening, targeted 3D super-resolution STED microscopy and quantitative image analysis. Using this smart microscopy workflow, we target the 3D organization of NEAT1 , an architectural RNA that constitutes the structural backbone of paraspeckles, a membraneless nuclear organelle. Using site-specific labeling, morphological sorting and particle averaging, we reconstruct the morphological space of paraspeckles along their development cycle from over 10,000 individual particles. Applying spherical harmonics analysis, we report so-far unknown heterotypes of NEAT1 RNA organization. By integrating multi-positional labeling, we determine the coarse conformation of NEAT1 within the organelle and show that the 3’ end forms a loop-like structure at the surface of the paraspeckle. Our study reveals key structural features of paraspeckle structure and growth, as well as the molecular organization of its scaffolding RNA.
- Open Access
- 8 September 2025
- Published by Springer Nature in Nature Photonics
- Vol. 19 (10) , 1146-1156
Multispectral live-cell imaging with uncompromised spatiotemporal resolution
Multispectral imaging is an established method to extend the number of colours usable in fluorescence imaging beyond the typical limit of three or four. However, standard approaches are poorly suited to live-cell imaging owing to the need to separate light into many spectral channels, and unmixing algorithms struggle with low signal-to-noise ratio data. Here we introduce an approach for multispectral imaging in live cells that comprises an iterative spectral unmixing algorithm and eight-channel camera-based image-acquisition hardware. This enables the accurate unmixing of low signal-to-noise ratio datasets captured at video rates, while maintaining diffraction-limited spatial resolution. We use this approach on a commercial spinning-disk confocal microscope and a home-built oblique-plane light-sheet microscope to image one to seven spectrally distinct fluorophore species simultaneously, using both fluorescent protein fusions and small-molecule dyes. We further develop protein-binding proteins (minibinders), labelled with organic fluorophores, and use these in combination with our multispectral imaging approach to study the endosomal trafficking of cell-surface receptors at endogenous levels.
- 8 September 2025
- Published by Springer Nature in Nature Photonics
- Vol. 19 (10) , 1146-1156
Open AccessMultispectral live-cell imaging with uncompromised spatiotemporal resolution
Multispectral imaging is an established method to extend the number of colours usable in fluorescence imaging beyond the typical limit of three or four. However, standard approaches are poorly suited to live-cell imaging owing to the need to separate light into many spectral channels, and unmixing algorithms struggle with low signal-to-noise ratio data. Here we introduce an approach for multispectral imaging in live cells that comprises an iterative spectral unmixing algorithm and eight-channel camera-based image-acquisition hardware. This enables the accurate unmixing of low signal-to-noise ratio datasets captured at video rates, while maintaining diffraction-limited spatial resolution. We use this approach on a commercial spinning-disk confocal microscope and a home-built oblique-plane light-sheet microscope to image one to seven spectrally distinct fluorophore species simultaneously, using both fluorescent protein fusions and small-molecule dyes. We further develop protein-binding proteins (minibinders), labelled with organic fluorophores, and use these in combination with our multispectral imaging approach to study the endosomal trafficking of cell-surface receptors at endogenous levels.
- Open Access
- 5 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (5) , 11832-11852
Comparison of 3D structured illumination microscopy configurations in terms of spectral signal to noise ratio
Structured illumination microscopy (SIM) is a powerful method for high-resolution 3D-imaging that is compatible with standard fluorescence labeling techniques, as it provides optical sectioning as well as an up to twofold improvement of lateral resolution over widefield microscopy by combining illumination pattern diversity with computational reconstruction. We present a quantitative analysis of the image quality of 3D-SIM using the spectral signal-to-noise ratio (SSNR). In particular, we compare conventional woodpile illumination pattern based 3D-SIM, where the pattern is rotated and translated to acquire the set of raw images that is fed into the reconstruction algorithm, to (square or hexagonal) lattice 3D-SIM, where the pattern is only translated to assemble the input set of raw images. It appears that conventional 3D-SIM has better SSNR than the considered cases of lattice 3D-SIM. In addition, we have also analyzed the impact of the relative amplitude, angle of incidence and polarization of the set of illumination plane waves on image quality, and show how two SSNR derived metrics, SSNR volume and SSNR entropy, can be used to optimize these illumination pattern parameters.
- 5 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (5) , 11832-11852
Open AccessComparison of 3D structured illumination microscopy configurations in terms of spectral signal to noise ratio
Structured illumination microscopy (SIM) is a powerful method for high-resolution 3D-imaging that is compatible with standard fluorescence labeling techniques, as it provides optical sectioning as well as an up to twofold improvement of lateral resolution over widefield microscopy by combining illumination pattern diversity with computational reconstruction. We present a quantitative analysis of the image quality of 3D-SIM using the spectral signal-to-noise ratio (SSNR). In particular, we compare conventional woodpile illumination pattern based 3D-SIM, where the pattern is rotated and translated to acquire the set of raw images that is fed into the reconstruction algorithm, to (square or hexagonal) lattice 3D-SIM, where the pattern is only translated to assemble the input set of raw images. It appears that conventional 3D-SIM has better SSNR than the considered cases of lattice 3D-SIM. In addition, we have also analyzed the impact of the relative amplitude, angle of incidence and polarization of the set of illumination plane waves on image quality, and show how two SSNR derived metrics, SSNR volume and SSNR entropy, can be used to optimize these illumination pattern parameters.
- Top Cited PapersOpen Access
- 21 January 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-8
Noise amplification and ill-convergence of Richardson-Lucy deconvolution
Richardson-Lucy (RL) deconvolution optimizes the likelihood of the object estimate for an incoherent imaging system. It can offer an increase in contrast, but converges poorly, and shows enhancement of noise as the iteration progresses. We have discovered the underlying reason for this problematic convergence behaviour using a Cramér Rao Lower Bound (CRLB) analysis. An analytical expression for the CRLB diverges for spatial frequency components that approach the diffraction limit from below. The resulting mean noise variance per pixel diverges for large images. These results imply that a regular optimum of the likelihood does not exist, and that RL deconvolution is necessarily ill-convergent.
- 21 January 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-8
Top Cited PapersOpen AccessNoise amplification and ill-convergence of Richardson-Lucy deconvolution
Richardson-Lucy (RL) deconvolution optimizes the likelihood of the object estimate for an incoherent imaging system. It can offer an increase in contrast, but converges poorly, and shows enhancement of noise as the iteration progresses. We have discovered the underlying reason for this problematic convergence behaviour using a Cramér Rao Lower Bound (CRLB) analysis. An analytical expression for the CRLB diverges for spatial frequency components that approach the diffraction limit from below. The resulting mean noise variance per pixel diverges for large images. These results imply that a regular optimum of the likelihood does not exist, and that RL deconvolution is necessarily ill-convergent.
- Open Access
Calibration-free estimation of field dependent aberrations for single molecule localization microscopy across large fields of view
Image quality in single molecule localization microscopy (SMLM) depends largely on the accuracy and precision of the localizations. While under ideal imaging conditions the theoretically obtainable precision and accuracy are achieved, in practice this changes if (field dependent) aberrations are present. Currently there is no simple way to measure and incorporate these aberrations into the Point Spread Function (PSF) fitting, therefore the aberrations are often taken constant or neglected all together. Here we introduce a model-based approach to estimate the field-dependent aberration directly from single molecule data without a calibration step. This is made possible by using nodal aberration theory to incorporate the field-dependency of aberrations into our fully vectorial PSF model. This results in a limited set of aberration fit parameters that can be extracted from the raw frames without a bead calibration measurement, also in retrospect. The software implementation is computationally efficient, enabling fitting of a full 2D or 3D dataset within a few minutes. We demonstrate our method on 2D and 3D localization data of microtubuli and nuclear pore complexes over fields of view (FOV) of up to 180 μm and compare it with spline-based fitting and a deep learning based approach.
Open AccessCalibration-free estimation of field dependent aberrations for single molecule localization microscopy across large fields of view
Image quality in single molecule localization microscopy (SMLM) depends largely on the accuracy and precision of the localizations. While under ideal imaging conditions the theoretically obtainable precision and accuracy are achieved, in practice this changes if (field dependent) aberrations are present. Currently there is no simple way to measure and incorporate these aberrations into the Point Spread Function (PSF) fitting, therefore the aberrations are often taken constant or neglected all together. Here we introduce a model-based approach to estimate the field-dependent aberration directly from single molecule data without a calibration step. This is made possible by using nodal aberration theory to incorporate the field-dependency of aberrations into our fully vectorial PSF model. This results in a limited set of aberration fit parameters that can be extracted from the raw frames without a bead calibration measurement, also in retrospect. The software implementation is computationally efficient, enabling fitting of a full 2D or 3D dataset within a few minutes. We demonstrate our method on 2D and 3D localization data of microtubuli and nuclear pore complexes over fields of view (FOV) of up to 180 μm and compare it with spline-based fitting and a deep learning based approach.