BCBranden John Cord

Branden John Cord

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Branden John Cord has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intermediate catheter–assisted “putting down your foot” technique: Woven EndoBridge embolization of basilar tip aneurysm. Illustrative case

    by Mikael Aseged Shimekit, Branden J. Cord, Ben Waldau

    BACKGROUND: The Woven EndoBridge (WEB) device is commonly used for wide-neck bifurcation aneurysms, but deployment can be challenging in unfavorable anatomy, with risks of protrusion or malposition. The authors describe a novel intermediate catheter–assisted “putting down your foot” technique, used to reposition a protruding WEB device in a basilar tip aneurysm. OBSERVATIONS: A 57-year-old man with an incidental 7-mm basilar tip aneurysm underwent embolization with a 8 × 3–mm WEB SL device. During deployment, the WEB device developed a butterfly configuration with repeated protrusion into both posterior cerebral arteries, resulting in > 50% parent-vessel encroachment despite standard corrective maneuvers. An 8 × 2–mm device was unavailable, and a 7 × 3–mm WEB device would not have provided adequate lateral compression. The WEB device was therefore recompressed using the delivery wire and microcatheter, while a Vecta 46 intermediate catheter was advanced to the aneurysm neck for countersupport. This maneuver enabled controlled reexpansion and accurate repositioning. Final angiography demonstrated optimal apposition (WEB Occlusion Scale grade B) and stable device positioning after detachment. LESSONS: Intermediate catheter–assisted support can safely aid WEB positioning during difficult deployments with protrusion or deformation, although further experience with the technique is required to define its reproducibility and role among bailout techniques. https://thejns.org/doi/10.3171/CASE25945

    • 23 March 2026
      • Vol. 11  (12)
    Open Access

    Intermediate catheter–assisted “putting down your foot” technique: Woven EndoBridge embolization of basilar tip aneurysm. Illustrative case

    by Mikael Aseged Shimekit, Branden J. Cord, Ben Waldau

    The Woven EndoBridge (WEB) device is commonly used for wide-neck bifurcation aneurysms, but deployment can be challenging in unfavorable anatomy, with risks of protrusion or malposition. The authors describe a novel intermediate catheter–assisted “putting down your foot” technique, used to reposition a protruding WEB device in a basilar tip aneurysm. A 57-year-old man with an incidental 7-mm basilar tip aneurysm underwent embolization with a 8 × 3–mm WEB SL device. During deployment, the WEB device developed a butterfly configuration with repeated protrusion into both posterior cerebral arteries, resulting in > 50% parent-vessel encroachment despite standard corrective maneuvers. An 8 × 2–mm device was unavailable, and a 7 × 3–mm WEB device would not have provided adequate lateral compression. The WEB device was therefore recompressed using the delivery wire and microcatheter, while a Vecta 46 intermediate catheter was advanced to the aneurysm neck for countersupport. This maneuver enabled controlled reexpansion and accurate repositioning. Final angiography demonstrated optimal apposition (WEB Occlusion Scale grade B) and stable device positioning after detachment. Intermediate catheter–assisted support can safely aid WEB positioning during difficult deployments with protrusion or deformation, although further experience with the technique is required to define its reproducibility and role among bailout techniques. https://thejns.org/doi/10.3171/CASE25945

  • Open Access

    Single-Cell Analysis of Microglia and Monocyte Dynamics Uncover Distinct TNF-α-driven Neuroimmune Signatures after Intracerebral Hemorrhage

    by Yuki Kawamura, Conor W. Johnson, Jonathan DeLong, Lucas Paulo de Lima Camillo, Sofia E. Velazquez, Munetomo Takahashi, Hannah E. Beatty, Ryan Herbert, Branden J. Cord, Charles Matouk, et al.

    Innate immune cells contribute to both secondary brain injury and repair following intracerebral hemorrhage (ICH). However, the specific signaling pathways that govern initial inflammatory and subsequent reparative myeloid programs in living patients remain poorly understood. To better characterize mononuclear phagocyte cell changes over time, we generated a single-cell transcriptomic dataset of paired hematoma clot evacuates and peripheral blood samples from 10 patients following ICH (5 - 290 hours). We identified distinct populations of activated and TNF-low microglia, as well as a unique, highly activated population of CD14 + monocytes in the hematoma. Perturbation analysis identified TNF signaling as the primary driver of hematoma monocyte activation. Custom temporal trajectory analysis using single-cell foundation model embeddings found that this TNF response in monocytes was transient, peaking early after hemorrhage and decreasing over the following 48 hours as monocytes shifted to reparative transcriptional programs. Transiently activated microglia emerged as the likely acute source of TNF, signaling through monocyte TNFR2. Surprisingly, acute TNF signaling in CD14 + monocytes was also associated with better severity-adjusted neurological outcomes both in our cohort and an independent validation cohort. These findings suggest acute TNF signaling between activated microglia and hematoma-associated monocytes, particularly through TNFR2, may contribute to recovery following ICH.


  • Open Access

    Retrograde Middle Meningeal Artery Embolization through Mini Craniotomy for Subdural Hematoma Evacuation: A Technical Note

    by Buqing Liang, Anzhela D. Moskalik, Nina Yu, Dylan J. Goodrich, Gunnar Lee, Branden John Cord, Ben Waldau

    This report introduces a novel surgical technique for middle meningeal artery embolization (MMAE) during a mini-craniotomy for subdural hematoma (SDH) evacuation. A patient with multiple health issues presented with a 14 mm right subacute SDH. During surgery, the MMA was retrogradely catheterized and embolized using Onyx 18. This approach, combining MMAE with hematoma evacuation, resulted in successful resolution of the SDH without complications. The procedure offers a more efficient workflow by integrating 2 interventions into 1, potentially reducing recurrence rates of SDH.


  • Use of a dedicated open transcarotid access system for neurovascular disease

    by Nanthiya Sujijantarat, Daniela Renedo, Joseph Antonios, Andrew B Koo, Abdelaziz Amllay, Kamil Nowicki, Branden J Cord, Ryan Hebert, Adam de Havenon, Kevin N Sheth, et al.

    Background Transcarotid artery revascularization (TCAR) is an increasingly popular technique for the management of extracranial carotid stenosis. Its off-label use in the treatment of intracranial neurovascular disease is poorly described. Our objective is to describe the use of a dedicated open transcarotid access system for the treatment of neurovascular pathologies other than extracranial carotid stenosis. Methods We conducted a retrospective review of a prospectively maintained database of consecutive patients who underwent treatment of neurovascular disease at a single academic center using the ENROUTE Transcarotid Arterial Sheath. Demographics, procedural characteristics, and patient outcomes were reported. Results Twenty patients were included in the study between September 2017 and March 2023. The following pathologies were treated: intracranial atherosclerotic disease (ICAD, nine patients), complex cervico-petrous carotid disease (five patients), intracranial aneurysms (three patients), and large vessel occlusion-acute ischemic stroke (three patients). Eighteen of the 20 cases were performed with active carotid flow reversal. All cases were successfully completed. There were no access-related complications. One periprocedural complication was incurred: a microguidewire perforation during an exchange maneuver for the treatment of ICAD. Conclusion An open transcarotid approach using a dedicated transcarotid system may offer a safe alternative access strategy for the endovascular treatment of complex neurovascular pathologies when a traditional transfemoral or transradial approach is contraindicated or failed.


  • A technical guide to robotic-assisted carotid angioplasty and stenting with the Corindus CorPath GRX system

    by Anzhela D Moskalik, Buqing Liang, Branden J Cord, Ben Waldau

    Robotic-assisted carotid artery angioplasty and stenting is becoming more popular due to its precision and radiation safety. In this video, we present a case using the CorPath GRX Robotic System (Corindus, a Seimens Healthineers Company, Waltham, Massachusetts, USA) with step-by-step procedure process and technical nuances (video 1). We demonstrate that cervical carotid angioplasty and stenting can be safely performed using the robotic system with efficiency and accuracy.


  • Open Access

    Successful mechanical thrombectomy for terminal ICA bullet embolism: A case report

    by Jared Clouse, Bart Thaci, Austin Sy Clark, Michael Baggett, Osama Raslan, Charles Matouk, Ben Waldau, Branden Cord

    Bullet embolism after high velocity penetrating trauma is a rare event that can have devastating and wide-ranging effects distant from the original site of injury. A 29-year-old presented with multiple gunshot wounds to the chest, back, abdomen, and lower extremities but no penetrating head injury. After proper resuscitation, the patient was noted to have left-sided hemiparesis and computed tomography angiography of the head showed a bullet fragment that had traveled to the right M1 segment of the middle cerebral artery resulting in occlusion of the vessel. Mechanical thrombectomy was performed in an attempt to remove the bullet fragment but this was unsuccessful as the fragment was firmly lodged in the blood vessel. Aspiration of clot distal to the fragment was then performed in hopes of preventing a large volume ischemic event which was angiographically successful resulting in TICI 2c revascularization. This case demonstrates that thrombectomy can be safely and successfully performed distal to a lodged foreign body.


  • Robotic Diagnostic Cerebral Angiography: A Multicenter Experience of 113 Patients

    by Charles Beaman, Ayushi Gautam, Catherine Peterson, Naoki Kaneko, Luciano Ponce, Hamidreza Saber, Kasra Khatibi, Jose Morales, David Kimball, Jacob Ridge Lipovac, et al.

    Background Neurointerventional robotic systems have potential to reduce occupational radiation, improve procedural precision, and allow for future remote teleoperation. A limited number of single institution case reports and series have been published outlining the safety and feasibility of robot-assisted diagnostic cerebral angiography. Methods This is a multicenter, retrospective case series of patients undergoing diagnostic cerebral angiography at three separate institutions – University of California, Davis (UCD); University of California, Los Angeles (UCLA); and University of California, San Francisco (UCSF). The equipment used was the CorPath GRX Robotic System (Corindus, Waltham, MA). Results A total of 113 cases were analyzed who underwent robot-assisted diagnostic cerebral angiography from September 28, 2020 to October 27, 2022. There were no significant complications related to use of the robotic system including stroke, arterial dissection, bleeding, or pseudoaneurysm formation at the access site. Using the robotic system, 88 of 113 (77.9%) cases were completed successfully without unplanned manual conversion. The principal causes for unplanned manual conversion included challenging anatomy, technical difficulty with the bedside robotic cassette, and hubbing out of the robotic system due to limited working length. For robotic operation, average fluoroscopy time was 13.2 min (interquartile range (IQR), 9.3 to 16.8 min) and average cumulative air kerma was 975.8 mGY (IQR, 350.8 to 1073.5 mGy). Conclusions Robotic cerebral angiography with the CorPath GRX Robotic System is safe and easily learned by novice users without much prior manual experience. However, there are technical limitations such as a short working length and an inability to support 0.035” wires which may limit its widespread adoption in clinical practice.


  • Open Access

    Transcarotid artery revascularization (TCAR): a technical video

    by Nanthiya Sujijantarat, Joseph Antonios, Andrew Koo, Daniela Renedo, Branden J Cord, Akli Zetchi, Ryan Hebert, Charles Matouk

    Carotid revascularization is an important method of stroke prevention and includes carotid endarterectomy and transfemoral carotid angioplasty and stenting. More recently, a hybrid open-endovascular approach, termed transcarotid artery revascularization (TCAR), is garnering increased attention. Although fundamentally a ‘stenting procedure’, unlike transfemoral carotid angioplasty and stenting, TCAR allows for a proximal neuroprotection strategy based on flow reversal. In this technical video, we will review operative techniques and nuances of the TCAR procedure, with a particular focus on the neurovascular proceduralist looking to adopt this technique into routine clinical practice(video 1). Video 1 TCAR Technical Video:


  • Vessel wall MRI in ruptured cranial dural arteriovenous fistulas

    by Branden J Cord, Daniela Renedo, Corrado Santarosa, Nanthiya Sujijantarat, Joseph Antonios, Jennifer A Kim, Guido J Falcone, Kevin N Sheth, Ajay Malhotra, Charles C Matouk

    Intracranial high-resolution vessel wall MRI (VW-MRI) is an imaging paradigm that is useful in site-of-rupture identification in patients presenting with spontaneous subarachnoid hemorrhage and multiple intracranial aneurysms. Only a handful of case reports describe its potential utility in the evaluation of more complex brain vascular malformations. We report for the first time three patients with ruptured cranial dural arteriovenous fistulas (dAVFs) that were evaluated with high-resolution VW-MRI. The presumed site-of-rupture was identified based on contiguity of a venous ectasia with adjacent blood products and thick, concentric wall enhancement. This preliminary experience suggests a role for high-resolution VW-MRI in the evaluation of ruptured cranial dAVFs, in particular, site-of-rupture identification. It also supports an emerging hypothesis that all spontaneously ruptured, macrovascular lesions demonstrate avid vessel wall enhancement.