Anthony S. Podkowa
Anthony S. Podkowa has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Michael L. Oelze
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Champaign, IL 61801, USA
2 shared publications - Andrew C. Singer
Stony Brook University Stony Brook NY USA
1 shared publication - Jeffrey A. Ketterling
Department of Radiology, Weill Cornell Medicine, New York, NY, USA
1 shared publication Michael L Oelze
Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, UNITED STATES
1 shared publication
Latest Publications
- Open Access
- 1 January 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (2) , 025003
The convolutional interpretation of registration-based plane wave steered pulse-echo local sound speed estimators
Pulse-echo reconstruction of sound speed has long been considered a difficult problem within the domain of quantitative biomedical ultrasound. However, recent results (Jaeger 2015 Ultrasound Med. Biol . 41 235–50; Jaeger and Frenz 2015 Ultrasonics 62 299–304; Jaeger et al 2015 Phys. Med. Biol . 60 4497–515) have demonstrated that pulse-echo reconstructions of sound speed are achievable by exploiting correlations in post-beamformed data from steered, plane-wave excitations in the presence of diffuse scatterers. Despite these recent advances, a coherent theoretical imaging framework for describing the approach and results is lacking in the literature. In this work, the problem of sound speed reconstruction using steered, plane-wave excitations is reformulated as a truncated convolutional problem, and the theoretical implications of this reformulation are explored. Additionally, a matrix-free algorithm is proposed that leverages the computational and storage advantages of the fast Fourier transform (FFT) while simultaneously avoiding FFT wraparound artifacts. In particular, the storage constraints of the approach are reduced down from to over full matrix reconstruction, making this approach a better candidate for large reconstructions on clinical machines. This algorithm was then tested in the open source simulation package k -Wave to assess its robustness to modeling error and resolution reduction was demonstrated under full-wave propagation conditions relative to ideal straight-ray simulations. The method was also validated in a phantom experiment.
- 1 January 2020
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (2) , 025003
Open AccessThe convolutional interpretation of registration-based plane wave steered pulse-echo local sound speed estimators
Pulse-echo reconstruction of sound speed has long been considered a difficult problem within the domain of quantitative biomedical ultrasound. However, recent results (Jaeger 2015 Ultrasound Med. Biol . 41 235–50; Jaeger and Frenz 2015 Ultrasonics 62 299–304; Jaeger et al 2015 Phys. Med. Biol . 60 4497–515) have demonstrated that pulse-echo reconstructions of sound speed are achievable by exploiting correlations in post-beamformed data from steered, plane-wave excitations in the presence of diffuse scatterers. Despite these recent advances, a coherent theoretical imaging framework for describing the approach and results is lacking in the literature. In this work, the problem of sound speed reconstruction using steered, plane-wave excitations is reformulated as a truncated convolutional problem, and the theoretical implications of this reformulation are explored. Additionally, a matrix-free algorithm is proposed that leverages the computational and storage advantages of the fast Fourier transform (FFT) while simultaneously avoiding FFT wraparound artifacts. In particular, the storage constraints of the approach are reduced down from to over full matrix reconstruction, making this approach a better candidate for large reconstructions on clinical machines. This algorithm was then tested in the open source simulation package k -Wave to assess its robustness to modeling error and resolution reduction was demonstrated under full-wave propagation conditions relative to ideal straight-ray simulations. The method was also validated in a phantom experiment.
- Open Access
- 1 February 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (2) , 227
High-Frame-Rate Doppler Ultrasound Using a Repeated Transmit Sequence
The maximum detectable velocity of high-frame-rate color flow Doppler ultrasound is limited by the imaging frame rate when using coherent compounding techniques. Traditionally, high quality ultrasonic images are produced at a high frame rate via coherent compounding of steered plane wave reconstructions. However, this compounding operation results in an effective downsampling of the slow-time signal, thereby artificially reducing the frame rate. To alleviate this effect, a new transmit sequence is introduced where each transmit angle is repeated in succession. This transmit sequence allows for direct comparison between low resolution, pre-compounded frames at a short time interval in ways that are resistent to sidelobe motion. Use of this transmit sequence increases the maximum detectable velocity by a scale factor of the transmit sequence length. The performance of this new transmit sequence was evaluated using a rotating cylindrical phantom and compared with traditional methods using a 15-MHz linear array transducer. Axial velocity estimates were recorded for a range of mm/s and compared to the known ground truth. Using these new techniques, the root mean square error was reduced from over 400 mm/s to below 50 mm/s in the high-velocity regime compared to traditional techniques. The standard deviation of the velocity estimate in the same velocity range was reduced from 250 mm/s to 30 mm/s. This result demonstrates the viability of the repeated transmit sequence methods in detecting and quantifying high-velocity flow.- 1 February 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (2) , 227
Open AccessHigh-Frame-Rate Doppler Ultrasound Using a Repeated Transmit Sequence
The maximum detectable velocity of high-frame-rate color flow Doppler ultrasound is limited by the imaging frame rate when using coherent compounding techniques. Traditionally, high quality ultrasonic images are produced at a high frame rate via coherent compounding of steered plane wave reconstructions. However, this compounding operation results in an effective downsampling of the slow-time signal, thereby artificially reducing the frame rate. To alleviate this effect, a new transmit sequence is introduced where each transmit angle is repeated in succession. This transmit sequence allows for direct comparison between low resolution, pre-compounded frames at a short time interval in ways that are resistent to sidelobe motion. Use of this transmit sequence increases the maximum detectable velocity by a scale factor of the transmit sequence length. The performance of this new transmit sequence was evaluated using a rotating cylindrical phantom and compared with traditional methods using a 15-MHz linear array transducer. Axial velocity estimates were recorded for a range of mm/s and compared to the known ground truth. Using these new techniques, the root mean square error was reduced from over 400 mm/s to below 50 mm/s in the high-velocity regime compared to traditional techniques. The standard deviation of the velocity estimate in the same velocity range was reduced from 250 mm/s to 30 mm/s. This result demonstrates the viability of the repeated transmit sequence methods in detecting and quantifying high-velocity flow. - Open Access
Mbps Experimental Acoustic Through-Tissue Communications: MEAT-COMMS
Methods for digital, phase-coherent acoustic communication date to at least the work of Stojanjovic, et al [20], and the added robustness afforded by improved phase tracking and compensation of Johnson, et al [21]. This work explores the use of such methods for communications through tissue for potential biomedical applications, using the tremendous bandwidth available in commercial medical ultrasound transducers. While long-range ocean acoustic experiments have been at rates of under 100kbps, typically on the order of 1- 10kbps, data rates in excess of 120Mb/s have been achieved over cm-scale distances in ultrasonic testbeds [19]. This paper describes experimental transmission of digital communication signals through samples of real pork tissue and beef liver, achieving data rates of 20-30Mbps, demonstrating the possibility of real-time video-rate data transmission through tissue for inbody ultrasonic communications with implanted medical devices.
Open AccessMbps Experimental Acoustic Through-Tissue Communications: MEAT-COMMS
Methods for digital, phase-coherent acoustic communication date to at least the work of Stojanjovic, et al [20], and the added robustness afforded by improved phase tracking and compensation of Johnson, et al [21]. This work explores the use of such methods for communications through tissue for potential biomedical applications, using the tremendous bandwidth available in commercial medical ultrasound transducers. While long-range ocean acoustic experiments have been at rates of under 100kbps, typically on the order of 1- 10kbps, data rates in excess of 120Mb/s have been achieved over cm-scale distances in ultrasonic testbeds [19]. This paper describes experimental transmission of digital communication signals through samples of real pork tissue and beef liver, achieving data rates of 20-30Mbps, demonstrating the possibility of real-time video-rate data transmission through tissue for inbody ultrasonic communications with implanted medical devices.