Philip P. Graybill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Philip P. Graybill has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Mehdi Kiani
School of Electrical Engineering and Computer Science, Pennsylvania State University, University Park, PA, USA
4 shared publications - Bruce J. Gluckman
Center for Neural Engineering, The Pennsylvania State University, University Park, USA
3 shared publications - Catherine G. P. Berdanier
Department of Mechanical Engineering The Pennsylvania State University University Park Pennsylvania USA
1 shared publication - Hesam Sadeghi Gougheri
School of Electrical Engineering and Computer Science, Pennsylvania State University, University Park, USA
1 shared publication
Latest Publications
- 7 May 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 146, 105557
Optimization of an unscented Kalman filter for an embedded platform
- 7 May 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 146, 105557
Optimization of an unscented Kalman filter for an embedded platform
- Open Access
Optimization of an unscented Kalman filter for an embedded platform
The unscented Kalman filter (UKF) is finding increased application in biological fields. While realizing a complex UKF system in a low-power embedded platform offers many potential benefits including wearability, it also poses significant design challenges. Here we present a method for optimizing a UKF system for realization in an embedded platform. The method seeks to minimize both computation time and error in UKF state reconstruction and forecasting. As a case study, we applied the method to a model for the rat sleep-wake regulatory system in which 432 variants of the UKF over six different variables are considered. The optimization method is divided into three stages that assess computation time, state forecast error, and state reconstruction error. We apply a cost function to variants that pass all three stages to identify a variant that computes 27 times faster than the reference variant and maintains required levels of state estimation and forecasting accuracy. We draw the following insights: 1) process noise provides leeway for simplifying the model and its integration in ways that speed computation time while maintaining state forecasting accuracy, 2) the assimilation of observed data during the UKF correction step provides leeway for simplifying the UKF structure in ways that speed computation time while maintaining state reconstruction accuracy, and 3) the optimization process can be accelerated by decoupling variables that directly impact the underlying model from variables that impact the UKF structure. Author summary Powerful statistical tools can be used to estimate unmeasured information in biological systems and predict the system’s future state. Translating these tools from a desktop computer to small, wearable or implantable platforms can unlock many benefits, but presents many design challenges, because tradeoffs between computational simplicity and system accuracy must be balanced. We present an approach to translating one such widely used statistical tool, the unscented Kalman filter, from a desktop computer to a miniature device. We demonstrate the approach with a case study centering on the neural circuits governing the mammalian sleep-wake cycle. By exploiting uncertainty in the biology being estimated and the corrective influence of biological measurements, we arrive at a design that is easily computable on the miniature device and maintains a high level of accuracy. We anticipate that our approach will aid others in designing such miniaturized systems for a broad range of applications.
Open AccessOptimization of an unscented Kalman filter for an embedded platform
The unscented Kalman filter (UKF) is finding increased application in biological fields. While realizing a complex UKF system in a low-power embedded platform offers many potential benefits including wearability, it also poses significant design challenges. Here we present a method for optimizing a UKF system for realization in an embedded platform. The method seeks to minimize both computation time and error in UKF state reconstruction and forecasting. As a case study, we applied the method to a model for the rat sleep-wake regulatory system in which 432 variants of the UKF over six different variables are considered. The optimization method is divided into three stages that assess computation time, state forecast error, and state reconstruction error. We apply a cost function to variants that pass all three stages to identify a variant that computes 27 times faster than the reference variant and maintains required levels of state estimation and forecasting accuracy. We draw the following insights: 1) process noise provides leeway for simplifying the model and its integration in ways that speed computation time while maintaining state forecasting accuracy, 2) the assimilation of observed data during the UKF correction step provides leeway for simplifying the UKF structure in ways that speed computation time while maintaining state reconstruction accuracy, and 3) the optimization process can be accelerated by decoupling variables that directly impact the underlying model from variables that impact the UKF structure. Author summary Powerful statistical tools can be used to estimate unmeasured information in biological systems and predict the system’s future state. Translating these tools from a desktop computer to small, wearable or implantable platforms can unlock many benefits, but presents many design challenges, because tradeoffs between computational simplicity and system accuracy must be balanced. We present an approach to translating one such widely used statistical tool, the unscented Kalman filter, from a desktop computer to a miniature device. We demonstrate the approach with a case study centering on the neural circuits governing the mammalian sleep-wake cycle. By exploiting uncertainty in the biology being estimated and the corrective influence of biological measurements, we arrive at a design that is easily computable on the miniature device and maintains a high level of accuracy. We anticipate that our approach will aid others in designing such miniaturized systems for a broad range of applications.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Toward a Wearable Data Assimilation Platform
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Toward a Wearable Data Assimilation Platform
- 23 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (5) , 1075-1086
A Dual-Output Reconfigurable Shared-Inductor Boost-Converter/Current-Mode Inductive Power Management ASIC With 750% Extended Output-Power Range, Adaptive Switching Control, and Voltage-Power Regulation
This paper describes a dual-output, reconfigurable integrated power management (IPM) ASIC for inductive power delivery. The proposed ASIC operates either as a current-mode (CM) rectifier or a boost converter by sharing the receiver (Rx) coil (L Rx ) to improve performance of inductive power transmission against the variations of Rx input power (P Rx ) and dualoutput DC power (P L + P Hv ). Conventional IPM structures either fail to generate regulated outputs (e.g., V L and V Hv ) when the required P L + P Hv exceeds P Rx or suffer from low powerconversion efficiency (PCE) when PRx exceeds P L + P Hv due to voltage regulation and protection. To overcome these challenges, the proposed ASIC offers the unique capabilities of 1) generating multiple regulated outputs (V L = 2.6 V, V Hv = 3.9 V) directly from L Rx with single-stage conversion, 2) efficient CM operation with active rectification, enabled by adaptive switching control (ASC), 3) charging a large capacitor (C S ) with the purpose of operating as a shared-inductor boost converter (SBC), transferring energy from C S to C L and C Hv , when P Rx <; P L + P Hv , and 4) efficient voltage-power regulation (VPR). A proof-of-concept chip was fabricated in a 0.35-μm 2P4M standard CMOS process occupying 1.35-mm 2 active area. In measurements, the proposed ASIC was able to successfully provide regulated V L = 2.6 V and V Hv = 3.9 V despite significant variations in P Rx , P L , and P Hv . Moreover, the chip extended the peak output power range by 750% and improved the PCE by 1.3 times and 8.1 times thanks to the ASC and VPR, respectively.
- 23 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (5) , 1075-1086
A Dual-Output Reconfigurable Shared-Inductor Boost-Converter/Current-Mode Inductive Power Management ASIC With 750% Extended Output-Power Range, Adaptive Switching Control, and Voltage-Power Regulation
This paper describes a dual-output, reconfigurable integrated power management (IPM) ASIC for inductive power delivery. The proposed ASIC operates either as a current-mode (CM) rectifier or a boost converter by sharing the receiver (Rx) coil (L Rx ) to improve performance of inductive power transmission against the variations of Rx input power (P Rx ) and dualoutput DC power (P L + P Hv ). Conventional IPM structures either fail to generate regulated outputs (e.g., V L and V Hv ) when the required P L + P Hv exceeds P Rx or suffer from low powerconversion efficiency (PCE) when PRx exceeds P L + P Hv due to voltage regulation and protection. To overcome these challenges, the proposed ASIC offers the unique capabilities of 1) generating multiple regulated outputs (V L = 2.6 V, V Hv = 3.9 V) directly from L Rx with single-stage conversion, 2) efficient CM operation with active rectification, enabled by adaptive switching control (ASC), 3) charging a large capacitor (C S ) with the purpose of operating as a shared-inductor boost converter (SBC), transferring energy from C S to C L and C Hv , when P Rx <; P L + P Hv , and 4) efficient voltage-power regulation (VPR). A proof-of-concept chip was fabricated in a 0.35-μm 2P4M standard CMOS process occupying 1.35-mm 2 active area. In measurements, the proposed ASIC was able to successfully provide regulated V L = 2.6 V and V Hv = 3.9 V despite significant variations in P Rx , P L , and P Hv . Moreover, the chip extended the peak output power range by 750% and improved the PCE by 1.3 times and 8.1 times thanks to the ASC and VPR, respectively.