SASara-Adela Abad

Sara-Adela Abad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sara-Adela Abad has a total of 151 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bioinspired hooves for robotics: structural, material, and functional insights

    by Alok Ranjan, Shehara Perera, Zedong Zhang, Chris Kalogroulis, Franco Angelini, Manolo Garabini, Sara-Adela Abad, Thrishantha Nanayakkara

    Hoofed animals such as mountain goats, camels, horses, cows, and pigs exhibit exceptional capability in managing complex contact dynamics within their ecological niches, ranging from steep rocky slopes to loose sand and muddy ground. Recent numerical modelling and experimental work have demonstrated that the passive dynamics of mountain goat hooves can significantly reduce slippage without the need for active closed-loop control, provided that joint compliance lies within an appropriate range. In this paper, we review the biomechanics of biological hooves in relation to their environmental specialisations and examine the corresponding design principles, advantages, and limitations of robotic feet. By integrating evidence from biological morphology, robotic prototypes, and contact mechanics, we identify the critical morphological and material features required for robotic feet to perform effectively across diverse terrains. The paper highlights that: (a) layered and anisotropic material organisation in biological hooves enables passive, terrain-adaptive contact dynamics that provide stability and traction without active control; (b) anticipatory and morphology-driven contact modulation can replace high-bandwidth control in legged robots. This involves tunability of mechanical parameters, such as stiffness, damping, and contact geometry; (c) future robotic feet should combine bio-informed minimalism with adaptive compliance to achieve terrain-general locomotion.

  • Open Access

    Stiffness Modelling and Control for Soft Material Continuum Robotic Manipulators

    by Jialei Shi, Wenlong Gaozhang, Sara-Adela Abad, Helge Wurdemann


  • Miniature Compliance Controllable Sensor for Tissue Stiffness Sensing and Palpation

    by Duncan G. Raitt, Shervanthi Homer-Vanniasinkam, Prokar Dasgupta, Sara-Adela Abad, Helge A. Wurdemann

    Tissue stiffness can provide key details about the health and type of tissues. This paper presents the creation of a miniaturised soft tissue stiffness sensor with dimensions that make it suitable for palpation in minimally invasive surgery. We introduce the stiffness sensor design and experimentally test its force sensing, elasticity measurement, and dynamic palpation performance. The sensor can measure normal forces with an adjustable range. Angled forces were measured with their magnitude and angles, θY and θX, root-mean-square errors (RMSE) of 8.37%, 6.68%, and 13.92% of their respective ranges. Furthermore, samples with an elasticity between 4.20 kPa and 177.62 kPa, which were not in the training set, were measured with an RMSE of 7.79% of the tested range. During palpation, the boundary between the 13.4 kPa elastomer and the 2 mm embedded 29.3 kPa elastomer was located with a signal-noise ratio (SNR) of 77.04:1 and a mean offset of 0.706 mm. This investigation provides new insights into sensing devices capable of fitting trocars while measuring tissue elasticity and force during minimally invasive procedures.


  • A Static Modeling and Evaluation Framework for Soft Continuum Robots With Reinforced Chambers

    by Jialei Shi, Hanyu Jin, Wenlong Gaozhang, Ge Shi, Sara-Adela Abad, Helge A. Wurdemann

    Elastomer-based soft manipulators with fibre-reinforced chambers, represent a prevalent design paradigm in soft robotics. These robots incorporate multiple actuation chambers, enabling elongation and bending motions. However, the inherent compliance of materials and the pressurised chambers inevitably introduce significant nonlinearity to these robots. Moreover, design of such robots often relies on a trial-and-error approach. Consequently, a comprehensive robot prototyping framework is of paramount importance. To achieve this, we present a static modelling, design and evaluation framework for soft robots with densely reinforced chambers (i.e., the angle between the reinforcement fibre and the axial direction of soft robots is 90°). We first propose a static analytical modelling framework to achieve both the forward kinematics and the tip force generation modelling. This modelling framework accommodates the effects of pressurised chambers and (non)linear material behaviours. Furthermore, our design and evaluation framework incorporates an open-accessible simulation toolbox with a user-friendly graphical interface, along with a physical evaluation platform. The entire framework is validated by eight kinds of manipulators with varying diameters and lengths. Meanwhile, the nonlinearity introduced by geometrical deformation resulting from the elongation, the pressurised actuation chambers (i.e., the chamber stiffening effect), and material hyper-elasticity are investigated. Results also enable informed decision-making on design specifications prior to robot fabrication.


  • Open Access

    Opportunities and challenges for monitoring terrestrial biodiversity in the robotics age

    by Stephen Pringle, Martin Dallimer, Mark A. Goddard, Léni K. Le Goff, Emma Hart, Simon J. Langdale, Jessica C. Fisher, Sara-Adela Abad, Marc Ancrenaz, Fabio Angeoletto, et al.

    With biodiversity loss escalating globally, a step change is needed in our capacity to accurately monitor species populations across ecosystems. Robotic and autonomous systems (RAS) offer technological solutions that may substantially advance terrestrial biodiversity monitoring, but this potential is yet to be considered systematically. We used a modified Delphi technique to synthesize knowledge from 98 biodiversity experts and 31 RAS experts, who identified the major methodological barriers that currently hinder monitoring, and explored the opportunities and challenges that RAS offer in overcoming these barriers. Biodiversity experts identified four barrier categories: site access, species and individual identification, data handling and storage, and power and network availability. Robotics experts highlighted technologies that could overcome these barriers and identified the developments needed to facilitate RAS-based autonomous biodiversity monitoring. Some existing RAS could be optimized relatively easily to survey species but would require development to be suitable for monitoring of more ‘difficult’ taxa and robust enough to work under uncontrolled conditions within ecosystems. Other nascent technologies (for instance, new sensors and biodegradable robots) need accelerated research. Overall, it was felt that RAS could lead to major progress in monitoring of terrestrial biodiversity by supplementing rather than supplanting existing methods. Transdisciplinarity needs to be fostered between biodiversity and RAS experts so that future ideas and technologies can be codeveloped effectively.


  • Model-Based Static Compliance Analysis and Control for Pneumatic-Driven Soft Robots

    by Jialei Shi, Sara-Adela Abad, Ge Shi, Wenlong Gaozhang, Jian Sheng Dai, Helge A. Wurdemann

    Elastomer-based soft manipulators have been explored in various fields due to their inherent compliant properties. Understanding and regulation of robot's compliance are important to the design, modeling, and control of soft robots. However, the elastomers are nonlinear hyperelastic materials with distributed compliance. This property makes the compliance modeling and control of soft robots fundamentally different and more complex from their rigid counterparts. This article presents a neo-Hookean model-based compliance modeling and control approach to investigate and regulate the configuration-dependent compliance property of a pneumatic-driven soft manipulator. The neo-Hookean model is used to derive the stretch ratio and update the tangent modulus of materials. The robot's compliance is obtained by integration with the forward kinematics building on the static Cosserat rod model. The derived compliance matrix is utilized to regulate robot's compliance along the $x$-, $y$-, and $z$-axes. Computational and experimental validation demonstrate high fidelity of the proposed approach. Moreover, experiments illustrate that the exhibited robot's compliance can be regulated up to 49.5% higher or 34.2% lower compared to inherent robot's compliance. The proposed model-based compliance control strategy has also demonstrated its effectiveness in enhancing grasping ability when implemented on a soft gripper.


  • Open Access

    Bioinspired adaptable multiplanar mechano-vibrotactile haptic system

    by Sara-Adela Abad, Nicolas Herzig, Duncan Raitt, Martin Koltzenburg, Helge Wurdemann

    Several gaps persist in haptic device development due to the multifaceted nature of the sense of touch. Existing gaps include challenges enhancing touch feedback fidelity, providing diverse haptic sensations, and ensuring wearability for delivering tactile stimuli to the fingertips. Here, we introduce the Bioinspired Adaptable Multiplanar Haptic system, offering mechanotactile/steady and vibrotactile pulse stimuli with adjustable intensity (up to 298.1 mN) and frequencies (up to 130 Hz). This system can deliver simultaneous stimuli across multiple fingertip areas. The paper includes a full characterisation of our system. As the device can play an important role in further understanding human touch, we performed human stimuli sensitivity and differentiation experiments to evaluate the capability of delivering mechano-vibrotactile, variable intensity, simultaneous, multiplanar and operator agnostic stimuli. Our system promises to accelerate the development of touch perception devices, providing painless, operator-independent data crucial for researching and diagnosing touch-related disorders.


  • Soft-Tipped Sensor With Compliance Control for Elasticity Sensing and Palpation

    by Duncan G. Raitt, Mahmud Huseynov, Shervanthi Homer-Vanniasinkam, Helge A. Wurdemann, Sara-Adela Abad

    Stiffness sensing and palpation are essential for understanding object properties, including tissue health and fruit ripeness. Currently, there is limited research on using soft-tipped sensors for stiffness sensing and dynamic palpation. To address these challenges, we investigate how the pressure modulated optical tracking (PMOT) sensor can use compliance control to quantify tissue stiffness and detect margins in samples through dynamic palpation. Results show that the PMOT sensor modulus of elasticity sensing range is from 4.20 kPa up to 177.62 kPa. Across all untrained samples, elasticity was measured with a root-mean-square error (RMSE) of 7.72%. Further, it is shown that the sensor can locate margins between 13.4 kPa and embedded 29.3 kPa materials during palpation. When mounted on a linear rail, averaged for the direction of travel, the sensor's signal-to-noise ratio (SNR) was up to 39.5:1. Participants used the sensor to locate embedded margins in a teleoperation environment with visual feedback. This was achieved with an accuracy of 96.5%.


  • Position and Orientation Control for Hyperelastic Multisegment Continuum Robots

    by Jialei Shi, Sara-Adela Abad, Jian Sheng Dai, Helge A. Wurdemann

    Elastomer-based soft-continuum robots with an extensible backbone exhibit high flexibility. These manipulators might show nonlinear kinematic behaviors due to, for example, the material hyperelasticity and means of actuation. Formulating a reliable kinematic model for an effective inverse kinematics control strategy is challenging, but is paramount for allowing effective manoeuvrability and controllability. In this article, we devise a kinematic modeling and control method for pneumatic-driven soft-continuum robots (up to 100% elongation ratio). The method is based on the Cosserat rod model including a pressure-dependent dynamic modulus. The kinematic model and control strategy are then expressed as nonlinear least-squares optimization problems. Hence, various inverse kinematics control modes can be achieved for a multisegment robot, e.g., tip position and orientation control of the overall robot or tip position control of each segment. Simulations and experiments are both conducted to validate the proposed method. The results highlight the high fidelity of the modeling technique and the effectiveness of the proposed inverse kinematics controller. In particular, the modeling and trajectory control errors for a two-segment robot are smaller than 4.5 mm, i.e., 5% of the robot's overall length.


  • Open Access

    Stiffness modelling and analysis of soft fluidic-driven robots using Lie theory

    by Jialei Shi, Azadeh Shariati, Sara-Adela Abad, Yuanchang Liu, Jian S Dai, Helge A Wurdemann

    Soft robots have been investigated for various applications due to their inherently superior deformability and flexibility compared to rigid-link robots. However, these robots struggle to perform tasks that require on-demand stiffness, that is, exerting sufficient forces within allowable deflection. In addition, the soft and compliant materials also introduce large deformation and non-negligible nonlinearity, which makes the stiffness analysis and modelling of soft robots fundamentally challenging. This paper proposes a modelling framework to investigate the underlying stiffness and the equivalent compliance properties of soft robots under different configurations. Firstly, a modelling and analysis methodology is described based on Lie theory. Here, we derive two sets (the piecewise constant curvature and Cosserat rod model) of compliance models. Furthermore, the methodology can accommodate the nonlinear responses (e.g., bending angles) resulting from elongation of robots. Using this proposed methodology, the general Cartesian stiffness or compliance matrix can be derived and used for configuration-dependent stiffness analysis. The proposed framework is then instantiated and implemented on fluidic-driven soft continuum robots. The efficacy and modelling accuracy of the proposed methodology are validated using both simulations and experiments.