DRDuncan G. Raitt

Duncan G. Raitt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Duncan G. Raitt has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Miniature Compliance Controllable Sensor for Tissue Stiffness Sensing and Palpation

    by Duncan G. Raitt, Shervanthi Homer-Vanniasinkam, Prokar Dasgupta, Sara-Adela Abad, Helge A. Wurdemann

    Tissue stiffness can provide key details about the health and type of tissues. This paper presents the creation of a miniaturised soft tissue stiffness sensor with dimensions that make it suitable for palpation in minimally invasive surgery. We introduce the stiffness sensor design and experimentally test its force sensing, elasticity measurement, and dynamic palpation performance. The sensor can measure normal forces with an adjustable range. Angled forces were measured with their magnitude and angles, θY and θX, root-mean-square errors (RMSE) of 8.37%, 6.68%, and 13.92% of their respective ranges. Furthermore, samples with an elasticity between 4.20 kPa and 177.62 kPa, which were not in the training set, were measured with an RMSE of 7.79% of the tested range. During palpation, the boundary between the 13.4 kPa elastomer and the 2 mm embedded 29.3 kPa elastomer was located with a signal-noise ratio (SNR) of 77.04:1 and a mean offset of 0.706 mm. This investigation provides new insights into sensing devices capable of fitting trocars while measuring tissue elasticity and force during minimally invasive procedures.


  • Open Access

    Bioinspired adaptable multiplanar mechano-vibrotactile haptic system

    by Sara-Adela Abad, Nicolas Herzig, Duncan Raitt, Martin Koltzenburg, Helge Wurdemann

    Several gaps persist in haptic device development due to the multifaceted nature of the sense of touch. Existing gaps include challenges enhancing touch feedback fidelity, providing diverse haptic sensations, and ensuring wearability for delivering tactile stimuli to the fingertips. Here, we introduce the Bioinspired Adaptable Multiplanar Haptic system, offering mechanotactile/steady and vibrotactile pulse stimuli with adjustable intensity (up to 298.1 mN) and frequencies (up to 130 Hz). This system can deliver simultaneous stimuli across multiple fingertip areas. The paper includes a full characterisation of our system. As the device can play an important role in further understanding human touch, we performed human stimuli sensitivity and differentiation experiments to evaluate the capability of delivering mechano-vibrotactile, variable intensity, simultaneous, multiplanar and operator agnostic stimuli. Our system promises to accelerate the development of touch perception devices, providing painless, operator-independent data crucial for researching and diagnosing touch-related disorders.


  • Soft-Tipped Sensor With Compliance Control for Elasticity Sensing and Palpation

    by Duncan G. Raitt, Mahmud Huseynov, Shervanthi Homer-Vanniasinkam, Helge A. Wurdemann, Sara-Adela Abad

    Stiffness sensing and palpation are essential for understanding object properties, including tissue health and fruit ripeness. Currently, there is limited research on using soft-tipped sensors for stiffness sensing and dynamic palpation. To address these challenges, we investigate how the pressure modulated optical tracking (PMOT) sensor can use compliance control to quantify tissue stiffness and detect margins in samples through dynamic palpation. Results show that the PMOT sensor modulus of elasticity sensing range is from 4.20 kPa up to 177.62 kPa. Across all untrained samples, elasticity was measured with a root-mean-square error (RMSE) of 7.72%. Further, it is shown that the sensor can locate margins between 13.4 kPa and embedded 29.3 kPa materials during palpation. When mounted on a linear rail, averaged for the direction of travel, the sensor's signal-to-noise ratio (SNR) was up to 39.5:1. Participants used the sensor to locate embedded margins in a teleoperation environment with visual feedback. This was achieved with an accuracy of 96.5%.


  • Soft, Stiffness-Controllable Sensing Tip for On-Demand Force Range Adjustment With Angled Force Direction Identification

    by Duncan G. Raitt, Sara-Adela Abad, Shervanthi Homer-Vanniasinkam, Helge A. Wurdemann

    Force sensors are essential for measuring and controlling robot-object interactions. However, current force sensors have limited usability in applications such as grasping and palpation, where the range of angled forces changes between tasks. To address this limitation this paper proposes a novel optical-based soft-tipped force sensor capable of adjusting its range and sensitivity through pneumatic modulation. This research describes the sensor’s design and examines the relationship between the internal pressure of the sensor and its sensing range, sensitivity, single-axis force-sensing accuracy, and capability of measuring the angle and magnitude of non-normal forces. Results indicate that by increasing the pressure in the sensor, the sensing range can be increased and the sensitivity decreased. These results demonstrate that the sensor can measure normal forces reliably at each pressure using 4th order fits with root-mean-square error (RMSE) $\boldsymbol {\in } [0.032\;N 0.110\;N]$ . Finally, it is also demonstrated that by using a neural network, the sensor can measure the angle and magnitude of non-normal forces with RMSEs on trained variables of 0.0120 Rad for Y-angle ( $\boldsymbol {\theta }_{Y}$ ) measurements, 0.0109 Rad for X-angle ( $\boldsymbol {\theta }_{X}$ ) measurements, and 0.102 N for force measurements.