Hideki Ueda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hideki Ueda has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Goro Matsumiya
Chiba University Graduate School of Medicine
5 shared publications - Hiroki Kohno
Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan
4 shared publications - Michiko Watanabe
Department of Cardiovascular Surgery, Chiba University Hospital, Chiba, Japan.
4 shared publications - Tomohiko Inui
Department of Cardiovascular Surgery, Chiba University Hospital , Chiba 286-0041, Japan
4 shared publications - Yohei Kawasaki
Department of Biostatistics, Graduate School of Medicine, Saitama Medical University, Saitama, Japan
4 shared publications - Kaoru Matsuura
Department of Cardiovascular Surgery, Chiba University Hospital, Chiba City, Japan
3 shared publications
Latest Publications
- Open Access
- 1 August 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (8) , e35396
Diagnosis of Atrial Fibrillation Using Machine Learning With Wearable Devices After Cardiac Surgery: Algorithm Development Study
Background: Some attempts have been made to detect atrial fibrillation (AF) with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. Objective: This study is the second part of a 2-phase study aimed at developing a method for immediate detection of paroxysmal AF, using a wearable device with built-in photoplethysmography (PPG). The objective of this study is to develop an algorithm to immediately diagnose AF by an Apple Watch equipped with a PPG sensor that is worn by patients undergoing cardiac surgery and to use machine learning on the pulse data output from the device. Methods: A total of 80 patients who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative AF, using a telemetry-monitored electrocardiogram (ECG) and an Apple Watch. AF was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on the pulse rate data output from the Apple Watch. Results: One of the 80 patients was excluded from the analysis due to redness caused by wearing the Apple Watch. Of 79 patients, 27 (34.2%) developed AF, and 199 events of AF including brief AF were observed. Of them, 18 events of AF lasting longer than 1 hour were observed, and cross-correlation analysis showed that pulse rate measured by Apple Watch was strongly correlated (cross-correlation functions [CCF]: 0.6-0.8) with 8 events and very strongly correlated (CCF>0.8) with 3 events. The diagnostic accuracy by machine learning was 0.9416 (sensitivity 0.909 and specificity 0.838 at the point closest to the top left) for the area under the receiver operating characteristic curve. Conclusions: We were able to safely monitor pulse rate in patients who wore an Apple Watch after cardiac surgery. Although the pulse rate measured by the PPG sensor does not follow the heart rate recorded by telemetry-monitored ECGs in some parts, which may reduce the accuracy of AF diagnosis by machine learning, we have shown the possibility of clinical application of using only the pulse rate collected by the PPG sensor for the early detection of AF.
- 1 August 2022
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 6 (8) , e35396
Open AccessDiagnosis of Atrial Fibrillation Using Machine Learning With Wearable Devices After Cardiac Surgery: Algorithm Development Study
Background: Some attempts have been made to detect atrial fibrillation (AF) with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. Objective: This study is the second part of a 2-phase study aimed at developing a method for immediate detection of paroxysmal AF, using a wearable device with built-in photoplethysmography (PPG). The objective of this study is to develop an algorithm to immediately diagnose AF by an Apple Watch equipped with a PPG sensor that is worn by patients undergoing cardiac surgery and to use machine learning on the pulse data output from the device. Methods: A total of 80 patients who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative AF, using a telemetry-monitored electrocardiogram (ECG) and an Apple Watch. AF was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on the pulse rate data output from the Apple Watch. Results: One of the 80 patients was excluded from the analysis due to redness caused by wearing the Apple Watch. Of 79 patients, 27 (34.2%) developed AF, and 199 events of AF including brief AF were observed. Of them, 18 events of AF lasting longer than 1 hour were observed, and cross-correlation analysis showed that pulse rate measured by Apple Watch was strongly correlated (cross-correlation functions [CCF]: 0.6-0.8) with 8 events and very strongly correlated (CCF>0.8) with 3 events. The diagnostic accuracy by machine learning was 0.9416 (sensitivity 0.909 and specificity 0.838 at the point closest to the top left) for the area under the receiver operating characteristic curve. Conclusions: We were able to safely monitor pulse rate in patients who wore an Apple Watch after cardiac surgery. Although the pulse rate measured by the PPG sensor does not follow the heart rate recorded by telemetry-monitored ECGs in some parts, which may reduce the accuracy of AF diagnosis by machine learning, we have shown the possibility of clinical application of using only the pulse rate collected by the PPG sensor for the early detection of AF.
- Open Access
- 2 December 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Diagnosis of Atrial Fibrillation Using Machine Learning with Wearable Devices after Cardiac Surgery (Preprint)
BACKGROUND Some attempts have been made to detect atrial fibrillation with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. OBJECTIVE This study is the second part of a two-phase study aimed at developing a method for immediate detection of paroxysmal atrial fibrillation (AF) using a wearable device with built-in PPG. The objective of this study is to develop an algorithm to immediately diagnose atrial fibrillation by wearing an Apple Watch equipped with a photoplethysmography (PPG) sensor on patients undergoing cardiac surgery and using machine learning of the pulse data output from the device. METHODS A total of 80 subjects who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative atrial fibrillation using telemetry monitored ECG and Apple Watch. Atrial fibrillation was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on pulse rate data output from the Apple Watch. RESULTS One of the 80 patients was excluded from the analysis due to redness of the Apple Watch wearer. 27 (34.2%) of the 79 patients developed AF, and 199 events of AF, including brief AF, were observed. 18 events of AF lasting longer than 1 hour were observed, and Cross-correlation analysis (CCF) showed that pulse rate measured by Apple Watch was strongly correlated (CCF 0.6-0.8) with 8 events and very strongly correlated (CCF >0.8) with 3 events. The diagnostic accuracy by machine learning was 0.7952 (sensitivity 0.6312, specificity 0.8605 at the point closest to the top-left) for the AUC of the ROC curve. CONCLUSIONS We were able to safely monitor pulse rate in patients after cardiac surgery by wearing an Apple Watch. Although the pulse rate from the PPG sensor does not follow the heart rate of the telemetry monitoring ECG in some parts, which may reduce the accuracy of the diagnosis of atrial fibrillation by machine learning, we have shown the possibility of clinical application of early detection of atrial fibrillation using only the pulse rate collected by the PPG sensor. CLINICALTRIAL The use of wristband type continuous pulse measurement device with artificial intelligence for early detection of paroxysmal atrial fibrillation Clinical Research Protocol No. jRCTs032200032 https://jrct.niph.go.jp/latest-detail/jRCTs032200032
- 2 December 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDiagnosis of Atrial Fibrillation Using Machine Learning with Wearable Devices after Cardiac Surgery (Preprint)
BACKGROUND Some attempts have been made to detect atrial fibrillation with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. OBJECTIVE This study is the second part of a two-phase study aimed at developing a method for immediate detection of paroxysmal atrial fibrillation (AF) using a wearable device with built-in PPG. The objective of this study is to develop an algorithm to immediately diagnose atrial fibrillation by wearing an Apple Watch equipped with a photoplethysmography (PPG) sensor on patients undergoing cardiac surgery and using machine learning of the pulse data output from the device. METHODS A total of 80 subjects who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative atrial fibrillation using telemetry monitored ECG and Apple Watch. Atrial fibrillation was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on pulse rate data output from the Apple Watch. RESULTS One of the 80 patients was excluded from the analysis due to redness of the Apple Watch wearer. 27 (34.2%) of the 79 patients developed AF, and 199 events of AF, including brief AF, were observed. 18 events of AF lasting longer than 1 hour were observed, and Cross-correlation analysis (CCF) showed that pulse rate measured by Apple Watch was strongly correlated (CCF 0.6-0.8) with 8 events and very strongly correlated (CCF >0.8) with 3 events. The diagnostic accuracy by machine learning was 0.7952 (sensitivity 0.6312, specificity 0.8605 at the point closest to the top-left) for the AUC of the ROC curve. CONCLUSIONS We were able to safely monitor pulse rate in patients after cardiac surgery by wearing an Apple Watch. Although the pulse rate from the PPG sensor does not follow the heart rate of the telemetry monitoring ECG in some parts, which may reduce the accuracy of the diagnosis of atrial fibrillation by machine learning, we have shown the possibility of clinical application of early detection of atrial fibrillation using only the pulse rate collected by the PPG sensor. CLINICALTRIAL The use of wristband type continuous pulse measurement device with artificial intelligence for early detection of paroxysmal atrial fibrillation Clinical Research Protocol No. jRCTs032200032 https://jrct.niph.go.jp/latest-detail/jRCTs032200032
- Open Access
- 1 December 2020
- Published by Japanese Society of Internal Medicine in Internal Medicine
- Vol. 59 (23) , 3039-3044
Coexistence of Marfan-like Connective Tissue Disease with Morphologic Left Ventricular Non-compaction
We treated a man with co-incident Marfan-like connective tissue disease with morphologic left ventricular non-compaction (LVNC). He underwent valve-sparing aortic root replacement because of aortic root dilation at 43 years old. Pathological findings of the aorta revealed cystic medio-necrosis, consistent with Marfan syndrome. He developed congestive heart failure caused by LVNC at 47 years old. His daughter had scoliosis, and he had several physical characteristics suggestive of Marfan syndrome. We herein report a rare case of a patient who had Marfan-like connective disease with an LVNC appearance.
- 1 December 2020
- Published by Japanese Society of Internal Medicine in Internal Medicine
- Vol. 59 (23) , 3039-3044
Open AccessCoexistence of Marfan-like Connective Tissue Disease with Morphologic Left Ventricular Non-compaction
We treated a man with co-incident Marfan-like connective tissue disease with morphologic left ventricular non-compaction (LVNC). He underwent valve-sparing aortic root replacement because of aortic root dilation at 43 years old. Pathological findings of the aorta revealed cystic medio-necrosis, consistent with Marfan syndrome. He developed congestive heart failure caused by LVNC at 47 years old. His daughter had scoliosis, and he had several physical characteristics suggestive of Marfan syndrome. We herein report a rare case of a patient who had Marfan-like connective disease with an LVNC appearance.
- Open Access
- 22 January 2020
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 4 (1) , e14857
Use of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study
Background: Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. Objective: This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. Methods: A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. Results: Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). Conclusions: In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.
- 22 January 2020
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 4 (1) , e14857
Open AccessUse of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study
Background: Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. Objective: This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. Methods: A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. Results: Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). Conclusions: In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.
- Open Access
- 3 June 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Use of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study (Preprint)
BACKGROUND Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. OBJECTIVE This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. METHODS A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. RESULTS Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). CONCLUSIONS In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.
- 3 June 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessUse of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study (Preprint)
BACKGROUND Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. OBJECTIVE This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. METHODS A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. RESULTS Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). CONCLUSIONS In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.
- 1 January 2003
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 50 (15-17) , 2515-2522
Super strong field ionization of atoms by 10 19 W cm −2 , 10 Hz laser pulses
- 1 January 2003
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 50 (15-17) , 2515-2522
Super strong field ionization of atoms by 10 19 W cm −2 , 10 Hz laser pulses