MWMichiko Watanabe

Michiko Watanabe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Michiko Watanabe has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Psychological and socioeconomic impact of long-term home management on patients with left ventricular assist devices and their caregivers: a nationwide multicenter questionnaire survey

    by Michiko Watanabe, Goro Matsumiya, Hiroki Kohno, Koichiro Kinugawa

    Left ventricular assist device (LVAD) therapy requires safe long-term home management supported by patients, caregivers, and healthcare systems. In Japan, continuous caregiver availability was historically required or strongly expected in LVAD home management, although this framework has recently been relaxed. We evaluated the psychological and socioeconomic burden experienced by LVAD patients and primary caregivers under this former 24-h caregiver-accompaniment framework. This cross-sectional, nationwide anonymous web-based questionnaire survey was conducted through 79 LVAD centers between April and July 2024. De-identified individual-level data from 184 patients and 136 primary caregivers were analyzed. Prespecified comparisons of depressive symptoms according to caregiver-accompaniment burden and work/study status were performed within each respondent group, and multivariable logistic regression was used to identify factors associated with depressive symptoms. Psychological burden related to caregiver accompaniment was reported by 83.7% of patients and 61.8% of caregivers. Not working or studying was reported by 44.0% and 31.6%, respectively. Depressive symptoms were reported in 36.4% of patients and 35.3% of caregivers. Depressive symptoms were more frequent among respondents with caregiver-accompaniment burden than among those without such burden in both patients (61/154 [39.6%] vs. 6/30 [20.0%]; p = 0.041) and caregivers (38/84 [45.2%] vs. 10/52 [19.2%]; p = 0.002), whereas depressive symptoms did not differ significantly according to work/study status. Under the former 24-h caregiver-accompaniment framework, Japanese LVAD households reported substantial psychological and socioeconomic burdens. These findings provide real-world baseline data for evaluating recent policy relaxation and for designing support systems that promote quality of life and social reintegration while maintaining safety.

  • Open Access

    Diagnosis of Atrial Fibrillation Using Machine Learning With Wearable Devices After Cardiac Surgery: Algorithm Development Study

    by Daisuke Hiraoka, Tomohiko Inui, Eiryo Kawakami, Megumi Oya, Ayumu Tsuji, Koya Honma, Yohei Kawasaki, Yoshihito Ozawa, Yuki Shiko, Hideki Ueda, et al.

    Background: Some attempts have been made to detect atrial fibrillation (AF) with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. Objective: This study is the second part of a 2-phase study aimed at developing a method for immediate detection of paroxysmal AF, using a wearable device with built-in photoplethysmography (PPG). The objective of this study is to develop an algorithm to immediately diagnose AF by an Apple Watch equipped with a PPG sensor that is worn by patients undergoing cardiac surgery and to use machine learning on the pulse data output from the device. Methods: A total of 80 patients who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative AF, using a telemetry-monitored electrocardiogram (ECG) and an Apple Watch. AF was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on the pulse rate data output from the Apple Watch. Results: One of the 80 patients was excluded from the analysis due to redness caused by wearing the Apple Watch. Of 79 patients, 27 (34.2%) developed AF, and 199 events of AF including brief AF were observed. Of them, 18 events of AF lasting longer than 1 hour were observed, and cross-correlation analysis showed that pulse rate measured by Apple Watch was strongly correlated (cross-correlation functions [CCF]: 0.6-0.8) with 8 events and very strongly correlated (CCF>0.8) with 3 events. The diagnostic accuracy by machine learning was 0.9416 (sensitivity 0.909 and specificity 0.838 at the point closest to the top left) for the area under the receiver operating characteristic curve. Conclusions: We were able to safely monitor pulse rate in patients who wore an Apple Watch after cardiac surgery. Although the pulse rate measured by the PPG sensor does not follow the heart rate recorded by telemetry-monitored ECGs in some parts, which may reduce the accuracy of AF diagnosis by machine learning, we have shown the possibility of clinical application of using only the pulse rate collected by the PPG sensor for the early detection of AF.


  • Open Access

    Diagnosis of Atrial Fibrillation Using Machine Learning with Wearable Devices after Cardiac Surgery (Preprint)

    by Daisuke Hiraoka, Tomohiko Inui, Eiryo Kawakami, Megumi Oya, Ayumu Tsuji, Koya Honma, Yohei Kawasaki, Yoshihito Ozawa, Yuki Shiko, Hideki Ueda, et al.

    BACKGROUND Some attempts have been made to detect atrial fibrillation with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. OBJECTIVE This study is the second part of a two-phase study aimed at developing a method for immediate detection of paroxysmal atrial fibrillation (AF) using a wearable device with built-in PPG. The objective of this study is to develop an algorithm to immediately diagnose atrial fibrillation by wearing an Apple Watch equipped with a photoplethysmography (PPG) sensor on patients undergoing cardiac surgery and using machine learning of the pulse data output from the device. METHODS A total of 80 subjects who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative atrial fibrillation using telemetry monitored ECG and Apple Watch. Atrial fibrillation was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on pulse rate data output from the Apple Watch. RESULTS One of the 80 patients was excluded from the analysis due to redness of the Apple Watch wearer. 27 (34.2%) of the 79 patients developed AF, and 199 events of AF, including brief AF, were observed. 18 events of AF lasting longer than 1 hour were observed, and Cross-correlation analysis (CCF) showed that pulse rate measured by Apple Watch was strongly correlated (CCF 0.6-0.8) with 8 events and very strongly correlated (CCF >0.8) with 3 events. The diagnostic accuracy by machine learning was 0.7952 (sensitivity 0.6312, specificity 0.8605 at the point closest to the top-left) for the AUC of the ROC curve. CONCLUSIONS We were able to safely monitor pulse rate in patients after cardiac surgery by wearing an Apple Watch. Although the pulse rate from the PPG sensor does not follow the heart rate of the telemetry monitoring ECG in some parts, which may reduce the accuracy of the diagnosis of atrial fibrillation by machine learning, we have shown the possibility of clinical application of early detection of atrial fibrillation using only the pulse rate collected by the PPG sensor. CLINICALTRIAL The use of wristband type continuous pulse measurement device with artificial intelligence for early detection of paroxysmal atrial fibrillation Clinical Research Protocol No. jRCTs032200032 https://jrct.niph.go.jp/latest-detail/jRCTs032200032

  • Celiac Artery Dissection and Retroperitoneal Hemorrhage in Median Arcuate Ligament Syndrome Treated With a Stent and Transcatheter Arterial Embolization: Preprocedural 4-Dimensional Computed Tomography Angiography Assessment

    by Atsushi Saiga, Jun Koizumi, Koji Osumi, Joji Ota, Yoshihiro Kubota, Takeshi Wada, Akira Akutsu, Michiko Watanabe, Shinji Murai, Makiko Masuda, et al.

    A 61-year-old man presented with retroperitoneal hemorrhage caused by an aneurysm rupture of the pancreaticoduodenal arcade (PDA), and acute celiac artery dissection distal to celiac axis stenosis. Owing to the gradual growth of the false lumen, we planned to deploy a stent to the celiac artery dissection and embolize the PDA aneurysm. Prior to stent placement, we assessed the acute celiac artery dissection distal to the stenosis using four-dimensional computed tomography (CT) angiography through expiration/inspiration/expiration cycle. We diagnosed median arcuate ligament syndrome considering that the celiac axis showed a hooked narrowing at end-expiration, and the compression decreased at end-inspiration. Additionally, the true lumen distal to the stretched axis dilated in the inspiration phase. Therefore, we could advance a catheter into the true lumen during inspiration and successfully deploy a stent. Subsequently, laparoscopic median arcuate ligament release was performed after the stent deployment. A postoperative CT scan showed good patency in the stent, with disappearance of the blood filling the false lumen and with reduced celiac axis stenosis.


  • Open Access

    Use of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study

    by Tomohiko Inui, Hiroki Kohno, Yohei Kawasaki, Kaoru Matsuura, Hideki Ueda, Yusaku Tamura, Michiko Watanabe, Yuichi Inage, Yasunori Yakita, Yutaka Wakabayashi, et al.

    Background: Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. Objective: This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. Methods: A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. Results: Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). Conclusions: In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.


  • Open Access

    Use of a Smart Watch for Early Detection of Paroxysmal Atrial Fibrillation: Validation Study (Preprint)

    by Tomohiko Inui, Hiroki Kohno, Yohei Kawasaki, Kaoru Matsuura, Hideki Ueda, Yusaku Tamura, Michiko Watanabe, Yuichi Inage, Yasunori Yakita, Yutaka Wakabayashi, et al.

    BACKGROUND Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. OBJECTIVE This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. METHODS A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. RESULTS Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). CONCLUSIONS In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.

  • Latent class model with two latent variables for analysis of count data

    by Kazunori Yamaguchi, Naoko Sakurai, Michiko Watanabe