Mahmoud Tabrizchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mahmoud Tabrizchi has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Younes Valadbeigi
Department of Chemistry, Faculty of Science, Imam Khomeini International University, Qazvin 34148-96818, Iran
8 shared publications Vahideh Ilbeigi
TOF Tech. Pars Company, Isfahan Science & Technology Town, Isfahan, Iran
7 shared publications- Hossein Farrokhpour
Isfahan University of Technology
6 shared publications Hassan Shahraki
Department of Chemistry, Isfahan University of Technology, Isfahan, Iran
3 shared publicationsHossein Farrokhpour
Isfahan University of Technology
3 shared publicationsRazieh Parchami
Department of Chemistry, Isfahan University of Technology, Isfahan 84156-83111, Iran
3 shared publications
Latest Publications
- 10 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (28) , 15001-15009
Direct, Selective, and Rapid Measurement of HCN at Sub-ppb Levels Using HiT-CD-IMS: Applications to Cell Culture and Breath Analysis
This study demonstrates the use of a research-grade ion mobility spectrometer combined with a high-temperature negative corona discharge ionization source (HiT-CD-IMS) to detect hydrogen cyanide (HCN) emitted by Pseudomonas aeruginosa (PA) cultures and in human breath. The HCN spectrum revealed distinct peaks for CN-, CNO-, and (CN)2- ions, with a resolving power of 63, successfully overcoming potential interferences such as the H2S peak by optimizing the experimental conditions. This approach achieved an estimated limit of detection (LOD) of 0.18 ppb. The method was applied to monitor HCN production in PA cultures, demonstrating a clear correlation between bacterial growth and HCN emission. Additionally, breath samples from the mouth cavity and nose-exhaled samples showed measurable HCN concentrations in the range of 40-300 ppb and below 10 ppb, respectively. The technique's ability to measure HCN in complex biological environments with high sensitivity, even in the presence of water vapor and common respiratory compounds, underscores its potential for noninvasive detection of Pseudomonas aeruginosa in infections.
- 10 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (28) , 15001-15009
Direct, Selective, and Rapid Measurement of HCN at Sub-ppb Levels Using HiT-CD-IMS: Applications to Cell Culture and Breath Analysis
This study demonstrates the use of a research-grade ion mobility spectrometer combined with a high-temperature negative corona discharge ionization source (HiT-CD-IMS) to detect hydrogen cyanide (HCN) emitted by Pseudomonas aeruginosa (PA) cultures and in human breath. The HCN spectrum revealed distinct peaks for CN-, CNO-, and (CN)2- ions, with a resolving power of 63, successfully overcoming potential interferences such as the H2S peak by optimizing the experimental conditions. This approach achieved an estimated limit of detection (LOD) of 0.18 ppb. The method was applied to monitor HCN production in PA cultures, demonstrating a clear correlation between bacterial growth and HCN emission. Additionally, breath samples from the mouth cavity and nose-exhaled samples showed measurable HCN concentrations in the range of 40-300 ppb and below 10 ppb, respectively. The technique's ability to measure HCN in complex biological environments with high sensitivity, even in the presence of water vapor and common respiratory compounds, underscores its potential for noninvasive detection of Pseudomonas aeruginosa in infections.
- 30 September 2024
- Published by Elsevier in Food Chemistry
- Vol. 463 (Pt 4) , 141484
Feasibility of qualitative identification of some metal elements in rice grains using laser desorption ionization-time of flight mass spectrometry
- 30 September 2024
- Published by Elsevier in Food Chemistry
- Vol. 463 (Pt 4) , 141484
Feasibility of qualitative identification of some metal elements in rice grains using laser desorption ionization-time of flight mass spectrometry
- 24 January 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (3) , 374-382
Substrate-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry of Some Small Biomolecules Using TiO2-Nanotubes: The Effect of Nanotube Diameter and Salt Addition
Substrate-assisted laser desorption/ionization (SALDI) is a kind of soft ionization method that is most suitable for the analysis of low molecular weight analytes when it is coupled with a time-of-flight mass spectrometer. Unlike the conventional matrix-assisted laser desorption/ionization, there is no interference in the SALDI with matrices for the low mass analyte peaks (m/z < 700). The focus of this work is to develop substrates based on nanomaterials to obtain higher sensitivity, better reproducibility, and easier preparation. The mass spectra of some small molecules (capecitabine, hemin, methadone, noscapine, oxycodone, thebaine, malathion, chlorpyrifos, ethion, permethrin, and phosalone) deposited on the TiO2-nanotube (TiO2-NTs) plate by the SALDI-TOF-MS technique are reported. The nanotubes are synthesized in different diameter sizes of nanotubes via the anodizing method. The intensity of the analyte peaks and the softness of ionization are optimized by varying the diameter of nanotubes and adding relevant alkali salts to the analytes. In addition, the reproducibility of the signal intensity of analytes is optimized by changing the surface hydrophilicity of the TiO2-NT plate.
- 24 January 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (3) , 374-382
Substrate-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry of Some Small Biomolecules Using TiO2-Nanotubes: The Effect of Nanotube Diameter and Salt Addition
Substrate-assisted laser desorption/ionization (SALDI) is a kind of soft ionization method that is most suitable for the analysis of low molecular weight analytes when it is coupled with a time-of-flight mass spectrometer. Unlike the conventional matrix-assisted laser desorption/ionization, there is no interference in the SALDI with matrices for the low mass analyte peaks (m/z < 700). The focus of this work is to develop substrates based on nanomaterials to obtain higher sensitivity, better reproducibility, and easier preparation. The mass spectra of some small molecules (capecitabine, hemin, methadone, noscapine, oxycodone, thebaine, malathion, chlorpyrifos, ethion, permethrin, and phosalone) deposited on the TiO2-nanotube (TiO2-NTs) plate by the SALDI-TOF-MS technique are reported. The nanotubes are synthesized in different diameter sizes of nanotubes via the anodizing method. The intensity of the analyte peaks and the softness of ionization are optimized by varying the diameter of nanotubes and adding relevant alkali salts to the analytes. In addition, the reproducibility of the signal intensity of analytes is optimized by changing the surface hydrophilicity of the TiO2-NT plate.
- 8 June 2022
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 33 (7) , 1148-1160
Dynamic Response of Ion Mobility Spectrometry
Ion mobility spectrometers (IMS) are widely used in the security industry as well as in analytical measurements. Nevertheless, the IMS input is dynamic in nature because the sampling input can vary over time. Similar to most instruments, IMS is unable to respond immediately to variations in the input sample. Therefore, the measurements are made under transient conditions, which may affect the results. This work investigates the dynamic response of an IMS to different inputs, including steps, pulsed, exponential, and Gaussian functions. A theoretical model was developed based on two phenomena: the accumulation or dilution of a sample in the ionization region and the adsorption or desorption inside the injection port. Both processes have a charging/discharging nature. Thus, a mathematical expression was derived that takes into account two RC circuits in series. Fitting the output signal of the experimental data to the expression obtained from the model gave reasonable time constants of 2-4 s and 15-20 s for the dilution and the desorption processes, respectively. The model performance was evaluated by comparing the output with the experimental results, which were in excellent correlation. IMS was also found to behave in a manner similar to a second-order instrument, in which the output is related to the input via a second-order differential equation. These results are applicable to GC-IMS and IMS-based detectors.
- 8 June 2022
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 33 (7) , 1148-1160
Dynamic Response of Ion Mobility Spectrometry
Ion mobility spectrometers (IMS) are widely used in the security industry as well as in analytical measurements. Nevertheless, the IMS input is dynamic in nature because the sampling input can vary over time. Similar to most instruments, IMS is unable to respond immediately to variations in the input sample. Therefore, the measurements are made under transient conditions, which may affect the results. This work investigates the dynamic response of an IMS to different inputs, including steps, pulsed, exponential, and Gaussian functions. A theoretical model was developed based on two phenomena: the accumulation or dilution of a sample in the ionization region and the adsorption or desorption inside the injection port. Both processes have a charging/discharging nature. Thus, a mathematical expression was derived that takes into account two RC circuits in series. Fitting the output signal of the experimental data to the expression obtained from the model gave reasonable time constants of 2-4 s and 15-20 s for the dilution and the desorption processes, respectively. The model performance was evaluated by comparing the output with the experimental results, which were in excellent correlation. IMS was also found to behave in a manner similar to a second-order instrument, in which the output is related to the input via a second-order differential equation. These results are applicable to GC-IMS and IMS-based detectors.
- 24 March 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (12) , e9090
Effective collisional cross‐section of small ions in the gas phase: Application to ion mobility spectrometry
Rationale: The observed drift times of monoatomic ions, including alkali metal ions and halide anions, are not fully consistent with their size. When the effect of mass is included through the Mason–Schamp equation, the deviation gets worse so that the trend of the experimental collisional cross‐sections becomes completely opposite to what is expected. This is attributed to the stronger local electric field around smaller ions. The strong electric field in the vicinity of a small ion leads to strong ion–neutral interactions and creates a drag force against ion motion. The smaller the ions, the stronger the interaction, because of the higher charge density. Methods: In view of this, a modified equation is introduced to describe the relationship between the observed drift times or ion mobilities and the cross‐sections of small ions. Here, for small ions with high charge density, the experimental collision cross‐section is expressed as the effective collision cross‐section, Ω eff = σ i (1 + α / r i 3 ), that takes into account both intrinsic ion size, σ i , and the ion–molecule interactions through a correction term of α / r i 3 , which is proportional to the charge density. Results: A linear fit of the drift times of alkali metal ions and halide anions to the proposed equation showed relative deviations of <8.2%. The model successfully predicted the drift time of other small diatomic ions with reasonable error. Conclusions: The proposed model can be used as a simple and efficient relationship in predicting the effective cross‐section of small ions.
- 24 March 2021
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (12) , e9090
Effective collisional cross‐section of small ions in the gas phase: Application to ion mobility spectrometry
Rationale: The observed drift times of monoatomic ions, including alkali metal ions and halide anions, are not fully consistent with their size. When the effect of mass is included through the Mason–Schamp equation, the deviation gets worse so that the trend of the experimental collisional cross‐sections becomes completely opposite to what is expected. This is attributed to the stronger local electric field around smaller ions. The strong electric field in the vicinity of a small ion leads to strong ion–neutral interactions and creates a drag force against ion motion. The smaller the ions, the stronger the interaction, because of the higher charge density. Methods: In view of this, a modified equation is introduced to describe the relationship between the observed drift times or ion mobilities and the cross‐sections of small ions. Here, for small ions with high charge density, the experimental collision cross‐section is expressed as the effective collision cross‐section, Ω eff = σ i (1 + α / r i 3 ), that takes into account both intrinsic ion size, σ i , and the ion–molecule interactions through a correction term of α / r i 3 , which is proportional to the charge density. Results: A linear fit of the drift times of alkali metal ions and halide anions to the proposed equation showed relative deviations of <8.2%. The model successfully predicted the drift time of other small diatomic ions with reasonable error. Conclusions: The proposed model can be used as a simple and efficient relationship in predicting the effective cross‐section of small ions.
- 1 December 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1634, 461676
Online detection and measurement of elemental mercury vapor by ion mobility spectrometry with chloroform dopant
- 1 December 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1634, 461676
Online detection and measurement of elemental mercury vapor by ion mobility spectrometry with chloroform dopant
- 14 June 2020
- Published by Springer Nature in International Journal for Ion Mobility Spectrometry
- Vol. 23 (2) , 117-125
Rapid analysis of lithium in serum samples by thermal ionization ion mobility spectrometry
- 14 June 2020
- Published by Springer Nature in International Journal for Ion Mobility Spectrometry
- Vol. 23 (2) , 117-125
Rapid analysis of lithium in serum samples by thermal ionization ion mobility spectrometry
- 13 November 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (24) , 15932-15940
Humidity Effect on the Drift Times of the Reactant Ions in Ion Mobility Spectrometry
The effect of moisture content on the drift times of NH4+ and H3O+ reactant ions at different temperatures was experimentally and theoretically studied using an ion mobility spectrometer (IMS). The peak positions of the ions shifted to higher drift times as the humidity of the drift gas increased. The peak displacements were attributed to the consecutive formation of hydrated ion clusters, RI+(H2O)n. Using chemical equilibrium relations and thermodynamic data derived from DFT calculation, a model was proposed to formulate the change in the drift times as 1/t¬d = 1/td-βTlog[H2O], where β is a constant and T is temperature. [H2O] is the concentration of water in ppm and, td is the drift time at the standard condition of [H2O]=1 ppm. The proposed equation perfectly predicted the change in the drift times of the reactant ions as a function of the moisture in the drift gas. Accordingly, standard mobility, K= K -T ln[H2O], was defined, which is independent of the moisture level of the drift gas and reflects the chemical reactivity. In this work, it is proposed to correct the reported reduced mobilities for the moisture to a standard condition of 1 ppm water concentration, in a similar manner to the corrections to the standard temperature and pressure of 273 K and 760 mbar, respectively. Finally, the likelihood that different hydrates forms of the reactant ion exist is discussed based on the entropy concept.
- 13 November 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (24) , 15932-15940
Humidity Effect on the Drift Times of the Reactant Ions in Ion Mobility Spectrometry
The effect of moisture content on the drift times of NH4+ and H3O+ reactant ions at different temperatures was experimentally and theoretically studied using an ion mobility spectrometer (IMS). The peak positions of the ions shifted to higher drift times as the humidity of the drift gas increased. The peak displacements were attributed to the consecutive formation of hydrated ion clusters, RI+(H2O)n. Using chemical equilibrium relations and thermodynamic data derived from DFT calculation, a model was proposed to formulate the change in the drift times as 1/t¬d = 1/td-βTlog[H2O], where β is a constant and T is temperature. [H2O] is the concentration of water in ppm and, td is the drift time at the standard condition of [H2O]=1 ppm. The proposed equation perfectly predicted the change in the drift times of the reactant ions as a function of the moisture in the drift gas. Accordingly, standard mobility, K= K -T ln[H2O], was defined, which is independent of the moisture level of the drift gas and reflects the chemical reactivity. In this work, it is proposed to correct the reported reduced mobilities for the moisture to a standard condition of 1 ppm water concentration, in a similar manner to the corrections to the standard temperature and pressure of 273 K and 760 mbar, respectively. Finally, the likelihood that different hydrates forms of the reactant ion exist is discussed based on the entropy concept.
- 23 May 2019
- Published by Springer Nature in International Journal for Ion Mobility Spectrometry
- Vol. 22 (2) , 51-58
Thermionic sodium ion source versus corona discharge in detection of alkaloids using ion mobility spectrometry
- 23 May 2019
- Published by Springer Nature in International Journal for Ion Mobility Spectrometry
- Vol. 22 (2) , 51-58
Thermionic sodium ion source versus corona discharge in detection of alkaloids using ion mobility spectrometry