Abstract
Ion mobility spectrometers (IMS) are widely used in the security industry as well as in analytical measurements. Nevertheless, the IMS input is dynamic in nature because the sampling input can vary over time. Similar to most instruments, IMS is unable to respond immediately to variations in the input sample. Therefore, the measurements are made under transient conditions, which may affect the results. This work investigates the dynamic response of an IMS to different inputs, including steps, pulsed, exponential, and Gaussian functions. A theoretical model was developed based on two phenomena: the accumulation or dilution of a sample in the ionization region and the adsorption or desorption inside the injection port. Both processes have a charging/discharging nature. Thus, a mathematical expression was derived that takes into account two RC circuits in series. Fitting the output signal of the experimental data to the expression obtained from the model gave reasonable time constants of 2-4 s and 15-20 s for the dilution and the desorption processes, respectively. The model performance was evaluated by comparing the output with the experimental results, which were in excellent correlation. IMS was also found to behave in a manner similar to a second-order instrument, in which the output is related to the input via a second-order differential equation. These results are applicable to GC-IMS and IMS-based detectors.Keywords
This publication has 36 references indexed in Scilit:
- Positive corona discharge ion source with IMS/MS to detect impurities in high purity NitrogenThe European Physical Journal Applied Physics, 2011
- Accurate, reproducible measurement of acetone concentration in breath using selected ion flow tube-mass spectrometryJournal of Breath Research, 2010
- Coupling Capillary Electrophoresis and Ion Mobility Spectrometry via Electrospray Interface: a Preliminary StudyAdvanced Materials Research, 2010
- Noncompetitive peak decay analysis of drug–protein dissociation by high‐performance affinity chromatographyJournal of Separation Science, 2009
- Design and optimization of a corona discharge ionization source for ion mobility spectrometryReview of Scientific Instruments, 2000
- Extending the concentration and linear dynamic range of ion mobility spectrometry with a sheath flow inletAnalytica Chimica Acta, 1999
- Experimental signal analysis in ion mobility spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1991
- Advances in Ion Mobility Spectrometry: 1980–1990Critical Reviews in Analytical Chemistry, 1991
- Generation of gaseous standards using exponential dilution flasks in seriesAnalytica Chimica Acta, 1990
- Dynamic response of ion-selective membrane electrodesAnalytical Chemistry, 1975