Takashi Asai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Takashi Asai has a total of 142 co-authors. Here are the top co-authors by number of shared publications:
K. Shingu
Kansai Medical University Yawata, Kyoto, Japan Kansai Medical University Moriguchi, Osaka, Japan
21 shared publicationsKoh Shingu
Department of Anaesthesiology, Kansai Medical University, Moriguchi City, Osaka, Japan
14 shared publicationsYasuhisa Okuda
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
13 shared publications- Katsuhide Masui
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
11 shared publications K. Murao
Kansai Medical University, Moriguchi City Osaka, 570–8507, Japan
5 shared publications- Kei Takahashi
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
5 shared publications
Latest Publications
- 22 October 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-2
In reply: PRIMARY outcomes and secondary outcomes of a flexible bronchoscope-aided orotracheal intubation
- 22 October 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-2
In reply: PRIMARY outcomes and secondary outcomes of a flexible bronchoscope-aided orotracheal intubation
- 14 October 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-2
Detection of gas leakage from an anesthesia machine using a halogen detector
- 14 October 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-2
Detection of gas leakage from an anesthesia machine using a halogen detector
- 17 September 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-3
In reply: what is the main cause of hypotension after induction of anesthesia with remimazolam in elderly patients?
- 17 September 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-3
In reply: what is the main cause of hypotension after induction of anesthesia with remimazolam in elderly patients?
- 11 September 2026
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 145 (5) , 1325-1329
Era of Sugammadex: Reply
Was not provided for this article.
- 11 September 2026
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 145 (5) , 1325-1329
Era of Sugammadex: Reply
Was not provided for this article.
- Open Access
- 19 July 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-10
Efficacy of an aerosol suction device and a drape in reducing surgical smoke exposure to patients and anesthesiologists: a prospective randomized controlled study
Purpose Surgical smoke generated during the use of an electrosurgical unit is a source of pollution, but preventive methods for patients and anesthesiologists have been insufficiently studied. Methods A total of 120 elective abdominal or breast surgeries were randomly allocated to one of three circumstances: the use of an aerosol suction device (Free-100 M®, Forest-One, Chiba, Japan), a surgical drape placed between the surgical field and the patient’s head, or none. Counts of airborne particles were measured at the patient’s head and at the anesthesiologist’s position before and during the use of an electrosurgical unit. Results The use of the suction device significantly reduced the counts of aerosol at the patient’s position (P < 0.001, 95% CI for median difference: − 342,957/L, − 144,576/L), and at the anesthesiologist’s position (P < 0.001, 95% CI − 270,894/L, − 111,422/L). The use of the drape also significantly reduced the counts at the patient’s position (P < 0.001, 95% CI − 460,837/L, − 247,737/L) and at the anesthesiologist’s position (P < 0.001, 95% CI − 344,673/L, − 190,364/L). The drape was significantly more effective than the suction device in reducing the counts (P < 0.001, 95% CI − 97,105/L, − 42,333/L at the patient’s position; P < 0.001, 95% CI − 100,495/L, − 29,594/L at the anesthesiologist’s position). Conclusions Both the aerosol suction device and a drape between the surgical field and the patient’s head can reduce the amount of surgical smoke to the patients and anesthesiologists, and the drape would be more effective.
- 19 July 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-10
Open AccessEfficacy of an aerosol suction device and a drape in reducing surgical smoke exposure to patients and anesthesiologists: a prospective randomized controlled study
Purpose Surgical smoke generated during the use of an electrosurgical unit is a source of pollution, but preventive methods for patients and anesthesiologists have been insufficiently studied. Methods A total of 120 elective abdominal or breast surgeries were randomly allocated to one of three circumstances: the use of an aerosol suction device (Free-100 M®, Forest-One, Chiba, Japan), a surgical drape placed between the surgical field and the patient’s head, or none. Counts of airborne particles were measured at the patient’s head and at the anesthesiologist’s position before and during the use of an electrosurgical unit. Results The use of the suction device significantly reduced the counts of aerosol at the patient’s position (P < 0.001, 95% CI for median difference: − 342,957/L, − 144,576/L), and at the anesthesiologist’s position (P < 0.001, 95% CI − 270,894/L, − 111,422/L). The use of the drape also significantly reduced the counts at the patient’s position (P < 0.001, 95% CI − 460,837/L, − 247,737/L) and at the anesthesiologist’s position (P < 0.001, 95% CI − 344,673/L, − 190,364/L). The drape was significantly more effective than the suction device in reducing the counts (P < 0.001, 95% CI − 97,105/L, − 42,333/L at the patient’s position; P < 0.001, 95% CI − 100,495/L, − 29,594/L at the anesthesiologist’s position). Conclusions Both the aerosol suction device and a drape between the surgical field and the patient’s head can reduce the amount of surgical smoke to the patients and anesthesiologists, and the drape would be more effective.
- Open Access
- 14 July 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-5
Relationship between age and blood pressure reduction during induction of general anesthesia with remimazolam: an observational study
The inhibitory effect of remimazolam on the blood pressure may be less than propofol, but its inhibitory effect may differ between different age groups. We studied 50 patients to assess if there was a correlation between the patient’s age and the decrease in the blood pressure after induction of anesthesia with remimazolam at 6 mg/kg/h (1 mg/kg/h after the loss of consciousness), with fentanyl 2 µg/kg and remifentanil 0.25 µg/kg/min. Relation between age and the lowest mean arterial pressure was examined, and the incidence of hypotension (defined as the lowest mean arterial pressure ≦ 60 mmHg) was compared between patients ≧ 70 yr-old and those < 70 yr-old. There was a significant correlation between the age and percentage decrease in mean arterial pressure (r: 0.65; P < < 0.0001). There was also significant correlation between the age and the lowest mean arterial pressure (r: 0.49; P = 0.0003). The incidence of hypotension was significantly higher in patients ≧ 70 yr-old (15 of 24 patients (63%)) than in those < 70 yr-old (6 of 26 patients (23%)) (P = 0.009). Elderly patients were more likely to experience a greater decrease than younger in the blood pressure during induction of anesthesia with remimazolam.
- 14 July 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-5
Open AccessRelationship between age and blood pressure reduction during induction of general anesthesia with remimazolam: an observational study
The inhibitory effect of remimazolam on the blood pressure may be less than propofol, but its inhibitory effect may differ between different age groups. We studied 50 patients to assess if there was a correlation between the patient’s age and the decrease in the blood pressure after induction of anesthesia with remimazolam at 6 mg/kg/h (1 mg/kg/h after the loss of consciousness), with fentanyl 2 µg/kg and remifentanil 0.25 µg/kg/min. Relation between age and the lowest mean arterial pressure was examined, and the incidence of hypotension (defined as the lowest mean arterial pressure ≦ 60 mmHg) was compared between patients ≧ 70 yr-old and those < 70 yr-old. There was a significant correlation between the age and percentage decrease in mean arterial pressure (r: 0.65; P < < 0.0001). There was also significant correlation between the age and the lowest mean arterial pressure (r: 0.49; P = 0.0003). The incidence of hypotension was significantly higher in patients ≧ 70 yr-old (15 of 24 patients (63%)) than in those < 70 yr-old (6 of 26 patients (23%)) (P = 0.009). Elderly patients were more likely to experience a greater decrease than younger in the blood pressure during induction of anesthesia with remimazolam.
- Open Access
- 3 July 2026
- Published by Springer Nature in Journal of Anesthesia
Efficacy of inserting a flexible bronchoscope to a predetermined depth for orotracheal intubation by inexperienced personnel: a randomized-controlled study
Bronchoscopic tracheal intubation is an indispensable technique in patients with difficult airway, but it is often difficult, particularly for less-experienced anesthesiologists, to obtain a view of the glottis by bronchoscopy. We hypothesized that insertion of a flexible bronchoscope to a predetermined depth would facilitate bronchoscopic intubation. Fifty anesthetized patients were randomly allocated to two groups, and inexperienced anesthesiologists either inserted a bronchoscope along the center of the tongue (in group C), or along the hard palate to a predetermined depth based on the mouth-to-tragus distance (in group S). The success rate of obtaining a bronchoscopic view of the glottis (primary outcome) and other factors were compared. The success rate of obtaining a bronchoscopic view of the glottis was significantly higher in group S (24 of 25 patients) than in group C (17 of 25 patients) (P = 0.02; 95%CI for difference: 8 - 48%]). The success rate of tracheal intubation was significantly higher in group S (18 of 25 patients) than in group C (8 of 25) (P = 0.01). Time to glottic visualization was significantly shorter in group S (24 [14 - 40] s) than in group C (49 [30 - 120]] s) (P = 0.003), and apnea time was significantly shorter in group S (81 [52 - 120] s) than in group C (120 [109 - 120] s) (P = 0.004). Insertion of a bronchoscope for the mouth-to-tragus distance would increase the success rate of bronchoscopic intubation, by facilitating to obtain a bronchoscopic view of the glottis. jRCT1032250593.
- 3 July 2026
- Published by Springer Nature in Journal of Anesthesia
Open AccessEfficacy of inserting a flexible bronchoscope to a predetermined depth for orotracheal intubation by inexperienced personnel: a randomized-controlled study
Bronchoscopic tracheal intubation is an indispensable technique in patients with difficult airway, but it is often difficult, particularly for less-experienced anesthesiologists, to obtain a view of the glottis by bronchoscopy. We hypothesized that insertion of a flexible bronchoscope to a predetermined depth would facilitate bronchoscopic intubation. Fifty anesthetized patients were randomly allocated to two groups, and inexperienced anesthesiologists either inserted a bronchoscope along the center of the tongue (in group C), or along the hard palate to a predetermined depth based on the mouth-to-tragus distance (in group S). The success rate of obtaining a bronchoscopic view of the glottis (primary outcome) and other factors were compared. The success rate of obtaining a bronchoscopic view of the glottis was significantly higher in group S (24 of 25 patients) than in group C (17 of 25 patients) (P = 0.02; 95%CI for difference: 8 - 48%]). The success rate of tracheal intubation was significantly higher in group S (18 of 25 patients) than in group C (8 of 25) (P = 0.01). Time to glottic visualization was significantly shorter in group S (24 [14 - 40] s) than in group C (49 [30 - 120]] s) (P = 0.003), and apnea time was significantly shorter in group S (81 [52 - 120] s) than in group C (120 [109 - 120] s) (P = 0.004). Insertion of a bronchoscope for the mouth-to-tragus distance would increase the success rate of bronchoscopic intubation, by facilitating to obtain a bronchoscopic view of the glottis. jRCT1032250593.
- 18 March 2026
- Published by Springer Nature in Journal of Anesthesia
Usefulness of a skin-adhering needle guide
- 18 March 2026
- Published by Springer Nature in Journal of Anesthesia
Usefulness of a skin-adhering needle guide