Katsuhide Masui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katsuhide Masui has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Takashi Asai
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya City, Japan
11 shared publications Kei Takahashi
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
5 shared publications- Kei Takahashi
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
5 shared publications Takashi Asai
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
5 shared publications- Naoyuki Tsunoda
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, Koshigaya, Japan
2 shared publications - Tomoyuki Saito
Department of Anesthesiology, Dokkyo Medical University Saitama Medical Center, 2-1-50 Minamikoshigaya, Koshigaya, Saitama, 343-8555, Japan.
2 shared publications
Latest Publications
- 19 May 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-2
Laser beams and ultrasonography for neuraxial block
- 19 May 2026
- Published by Springer Nature in Journal of Anesthesia
- p. 1-2
Laser beams and ultrasonography for neuraxial block
- 16 April 2026
- Published by Springer Nature in Journal of Anesthesia
Catheterization of the distal radial artery in patients in prone position
- 16 April 2026
- Published by Springer Nature in Journal of Anesthesia
Catheterization of the distal radial artery in patients in prone position
- Open Access
- 1 April 2026
- Published by Springer Nature in Journal of Anesthesia
Efficacy of catheterization of the distal radial artery in blood pressure monitoring and blood sampling: a randomized controlled clinical study
The radial artery at the wrist (proximal radial artery) is the most common site for arterial catheterization, but catheterization may sometimes be difficult. The distal radial artery, located on the back of the hand, has been proposed as an alternative access site. As a randomized controlled study, 120 anesthetized patients were randomly assigned to receive arterial catheterization either to the proximal radial artery (Group P) or to the distal radial artery (Group D) under ultrasound guidance. The primary outcome was the incidence of loss of normal arterial pressure waveform during wrist movement. Secondary outcomes included the success rate, the number of attempts at insertion, and the incidence of loss of intraoperative arterial waveforms and of failed blood sampling. There was no significant difference in the success rate of insertion (P = 0.36, 95% CI for difference: -13%-2%) and in the number of attempts at insertion (P = 0.19) between the groups. Loss of arterial waveform during wrist movement was significantly lower in Group D (3 patients (5%)) than in Group P (22 patients (37%)); P < 0.0001, 95% CI for difference: 18%-45%. No significant differences were observed in intraoperative waveform loss (P = 1.0, 95% CI for difference: -5%-9%) or blood sampling failure (P = 0.24, 95% CI for difference: -3%-19%) between the groups. The distal radial artery may be a useful alternative site to the proximal radial artery for catheterization, particularly in adult patients in whom positional change is required.
- 1 April 2026
- Published by Springer Nature in Journal of Anesthesia
Open AccessEfficacy of catheterization of the distal radial artery in blood pressure monitoring and blood sampling: a randomized controlled clinical study
The radial artery at the wrist (proximal radial artery) is the most common site for arterial catheterization, but catheterization may sometimes be difficult. The distal radial artery, located on the back of the hand, has been proposed as an alternative access site. As a randomized controlled study, 120 anesthetized patients were randomly assigned to receive arterial catheterization either to the proximal radial artery (Group P) or to the distal radial artery (Group D) under ultrasound guidance. The primary outcome was the incidence of loss of normal arterial pressure waveform during wrist movement. Secondary outcomes included the success rate, the number of attempts at insertion, and the incidence of loss of intraoperative arterial waveforms and of failed blood sampling. There was no significant difference in the success rate of insertion (P = 0.36, 95% CI for difference: -13%-2%) and in the number of attempts at insertion (P = 0.19) between the groups. Loss of arterial waveform during wrist movement was significantly lower in Group D (3 patients (5%)) than in Group P (22 patients (37%)); P < 0.0001, 95% CI for difference: 18%-45%. No significant differences were observed in intraoperative waveform loss (P = 1.0, 95% CI for difference: -5%-9%) or blood sampling failure (P = 0.24, 95% CI for difference: -3%-19%) between the groups. The distal radial artery may be a useful alternative site to the proximal radial artery for catheterization, particularly in adult patients in whom positional change is required.
- 18 March 2026
- Published by Springer Nature in Journal of Anesthesia
Usefulness of a skin-adhering needle guide
- 18 March 2026
- Published by Springer Nature in Journal of Anesthesia
Usefulness of a skin-adhering needle guide
- 23 February 2026
- Published by Springer Nature in Journal of Anesthesia
- Vol. 40 (5) , 1-2
Catheter placement to the distal radial artery: its performance and clinical assessment in retrospective study
- 23 February 2026
- Published by Springer Nature in Journal of Anesthesia
- Vol. 40 (5) , 1-2
Catheter placement to the distal radial artery: its performance and clinical assessment in retrospective study
- Open Access
- 7 January 2026
- Published by Springer Nature in JA Clinical Reports
- Vol. 12 (1) , 4
Increase in the end-tidal carbon dioxide concentration during mediastinoscopic esophagectomy: a comment to a report of Haraguchi et al.
- 7 January 2026
- Published by Springer Nature in JA Clinical Reports
- Vol. 12 (1) , 4
Open AccessIncrease in the end-tidal carbon dioxide concentration during mediastinoscopic esophagectomy: a comment to a report of Haraguchi et al.
- 1 January 2026
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 136 (3) , 1038-1039
Desflurane vapouriser leak undetected by an automated pre-use check system
- 1 January 2026
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 136 (3) , 1038-1039
Desflurane vapouriser leak undetected by an automated pre-use check system
- 29 October 2025
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 136 (1) , 357-358
Halogen checker to detect gas leakage around the tracheal tube: a preliminary study
- 29 October 2025
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 136 (1) , 357-358
Halogen checker to detect gas leakage around the tracheal tube: a preliminary study
- 11 October 2025
- Published by Springer Nature in Journal of Anesthesia
- Vol. 40 (3) , 476-477
A three-way stopcock for one-lung ventilation using a 3D printer
- 11 October 2025
- Published by Springer Nature in Journal of Anesthesia
- Vol. 40 (3) , 476-477
A three-way stopcock for one-lung ventilation using a 3D printer