Niklas Müller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Niklas Müller has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Tiago Buckup
Institute of Physical Chemistry Heidelberg University Heidelberg Germany
3 shared publications - Florian Nicolai
Universität Heidelberg
2 shared publications Marcus Motzkus
Physikalisch-Chemisches Institut, Im Neuenheimer Feld 229, 69120 Heidelberg, Germany
2 shared publications- Marcus Motzkus
Physikalisch-Chemisches Institut, Ruprecht-Karls-Universität Heidelberg, D-69120 Heidelberg, Germany
2 shared publications - Thomas Pfeifer
Max-Planck-Institut für Kernphysik
2 shared publications Zuoye Liu
Max Planck Institute for Nuclear Physics, Saupfercheckweg 1, 69117 Heidelberg, Germany
2 shared publications
Latest Publications
- 30 September 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (19) , 5012-5015
Broadband mid-infrared phase retrieval for nonlinear microscopy
Spectral phase characterization of ultrashort laser pulses is essential in nonlinear micro-spectroscopy. Whereas in many applications phases are determined for near-infrared (NIR) pulses, successful mid-infrared (MIR) phase retrieval is rare. The spectral phase of ultra-broadband MIR pulses is determined over more than 1000 c m − 1 in the presented work. This is accomplished by exploiting the d-scan method in two variants. Both allow for detecting high signals by using the interaction of the MIR and NIR pulses. The two variants differ in imprinting the dispersion. While the dual d-scan imprints phases on both pulses, the Xd-scan method disperses the NIR pulses solely.
- 30 September 2021
- Published by Optica Publishing Group in Optics Letters
- Vol. 46 (19) , 5012-5015
Broadband mid-infrared phase retrieval for nonlinear microscopy
Spectral phase characterization of ultrashort laser pulses is essential in nonlinear micro-spectroscopy. Whereas in many applications phases are determined for near-infrared (NIR) pulses, successful mid-infrared (MIR) phase retrieval is rare. The spectral phase of ultra-broadband MIR pulses is determined over more than 1000 c m − 1 in the presented work. This is accomplished by exploiting the d-scan method in two variants. Both allow for detecting high signals by using the interaction of the MIR and NIR pulses. The two variants differ in imprinting the dispersion. While the dual d-scan imprints phases on both pulses, the Xd-scan method disperses the NIR pulses solely.
- 18 June 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (13) , 20970-20980
Acousto-optic modulator based dispersion scan for phase characterization and shaping of femtosecond mid-infrared pulses
Compression, shaping and characterization of broadband mid-infrared (MIR) pulses based on an acousto-optic modulator (AOM) pulse shaper is presented. Characterization of the spectral phase is achieved by an AOM-shaper based implementation of a dispersion scan (d-scan). The abilities of the setup are demonstrated by imprinting several test phases with increasing complexity on broadband MIR pulses centered at 3.2 gm and retrieval of the imprinted phases with the presented d-scan method. Phase characterization with d-scan in combination with an evolutionary algorithm allows us to compress the MIR pulses below 50 fs FWHM autocorrelation after the shaper. (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
- 18 June 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (13) , 20970-20980
Acousto-optic modulator based dispersion scan for phase characterization and shaping of femtosecond mid-infrared pulses
Compression, shaping and characterization of broadband mid-infrared (MIR) pulses based on an acousto-optic modulator (AOM) pulse shaper is presented. Characterization of the spectral phase is achieved by an AOM-shaper based implementation of a dispersion scan (d-scan). The abilities of the setup are demonstrated by imprinting several test phases with increasing complexity on broadband MIR pulses centered at 3.2 gm and retrieval of the imprinted phases with the presented d-scan method. Phase characterization with d-scan in combination with an evolutionary algorithm allows us to compress the MIR pulses below 50 fs FWHM autocorrelation after the shaper. (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
- 17 December 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (1) , 117-126
Flexible pulse shaping for sum frequency microspectroscopies
The complexity of experimental schemes still challenges the broad application of multimodal microscopy beyond fundamental research. Pulse shaping has been a promising candidate to assist in the implementation of flexible and compact schemes. In this work, its application is demonstrated for vibrational resonant sum frequency (SF) spectroscopy in a nonlinear Raman microscope. The mixing of an ultrabroadband NIR laser pulse with a difference-frequency-generated MIR spectrum provides spectral access from ${1750}\,\,{{\rm cm}^{ - 1}}$ to beyond ${3000}\,\,{{\rm cm}^{ - 1}}$ via two shaping methods: (i) homodyne MIR scanning and (ii) heterodyne multiplex. The versatility of shaper-based SF is demonstrated in the spectroscopy and microscopy of crystalline cholesterol and cysteine.- 17 December 2019
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 37 (1) , 117-126
Flexible pulse shaping for sum frequency microspectroscopies
The complexity of experimental schemes still challenges the broad application of multimodal microscopy beyond fundamental research. Pulse shaping has been a promising candidate to assist in the implementation of flexible and compact schemes. In this work, its application is demonstrated for vibrational resonant sum frequency (SF) spectroscopy in a nonlinear Raman microscope. The mixing of an ultrabroadband NIR laser pulse with a difference-frequency-generated MIR spectrum provides spectral access from ${1750}\,\,{{\rm cm}^{ - 1}}$ to beyond ${3000}\,\,{{\rm cm}^{ - 1}}$ via two shaping methods: (i) homodyne MIR scanning and (ii) heterodyne multiplex. The versatility of shaper-based SF is demonstrated in the spectroscopy and microscopy of crystalline cholesterol and cysteine.- 17 October 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (24) , 6025-6036
Towards a quantum cascade laser-based implant for the continuous monitoring of glucose
Continuous glucose monitoring enables an improved disease management for people with diabetes. However, state-of-the-art, enzyme-based, minimally invasive sensors lose their sensitivity over time and have to be replaced periodically. Here, we present the in vitro investigation of a quantum cascade laser-based measurement scheme that conceptually should be applicable over elongated periods of time due to its reagent-free nature and may therefore be considered as an approach towards long-term implantation. The method uses a miniaturized optofluidic interface in transflection geometry to measure the characteristic mid-infrared absorption properties of glucose. A glucose sensitivity of 3.2 mg dL−1 is achieved in aqueous glucose solutions. While this sensitivity drops to 12 mg dL−1 in the presence of biologically plausible, maximum concentrations of other monosaccharides, it is still well within the medically acceptable range according to Parkes error grid analysis. With a response time of less than five minutes, our sensor should be able to react adequately fast to physiological changes in glucose concentration. Finally, no drift or deterioration was found during an extended, 42 days in vitro experiment. These results underline the potential of this technique for its conceivable applicability in vivo as a long-term glucose monitoring implant.
- 17 October 2018
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 143 (24) , 6025-6036
Towards a quantum cascade laser-based implant for the continuous monitoring of glucose
Continuous glucose monitoring enables an improved disease management for people with diabetes. However, state-of-the-art, enzyme-based, minimally invasive sensors lose their sensitivity over time and have to be replaced periodically. Here, we present the in vitro investigation of a quantum cascade laser-based measurement scheme that conceptually should be applicable over elongated periods of time due to its reagent-free nature and may therefore be considered as an approach towards long-term implantation. The method uses a miniaturized optofluidic interface in transflection geometry to measure the characteristic mid-infrared absorption properties of glucose. A glucose sensitivity of 3.2 mg dL−1 is achieved in aqueous glucose solutions. While this sensitivity drops to 12 mg dL−1 in the presence of biologically plausible, maximum concentrations of other monosaccharides, it is still well within the medically acceptable range according to Parkes error grid analysis. With a response time of less than five minutes, our sensor should be able to react adequately fast to physiological changes in glucose concentration. Finally, no drift or deterioration was found during an extended, 42 days in vitro experiment. These results underline the potential of this technique for its conceivable applicability in vivo as a long-term glucose monitoring implant.
- Open Access
- 27 July 2018
- Published by AIP Publishing in APL Photonics
- Vol. 3 (9) , 092406
Invited Article: Coherent Raman and mid-IR microscopy using shaped pulses in a single-beam setup
The possibility to exploit shaped ultrabroadband laser pulses for molecular coherent control offers a unique implementation of numerous nonlinear spectroscopic methods in one setup. Nonlinear processes, such as coherent Raman microscopy, second harmonic generation, or two-photon fluorescence, which have been applied in many different applications in both the material and life sciences, can be selectively addressed and optimized just by changing the phase imprinted by a programmable pulse shaper. Here, the experimental realization of this concept for multimodal nonlinear microscopy is discussed and the successful implementation of adaptive spectral focussing schemes not only for nonlinear Raman but also for difference frequency generation based mid-infrared (Mid-IR) spectroscopy using a single broadband pulse from a Ti:sapphire laser is shown. Flexible pulse shaping enables tuning of the resonance frequency and the spectral width of the excitation. By variation of the instantaneous frequency difference and the amount of chirp, the experiment can be optimized to achieve high resolution spectroscopy reaching up to 20 cm−1. Matching the resolution of the experiment with the linewidths of the sample on the other hand optimizes the contrast for imaging at high signal levels. The combination and flexible switching between Raman or mid-IR excitation for spectroscopy and microscopy is demonstrated on alkynes, polymer films, and skin tissue. The simple addition of this complementary modality to an existing nonlinear microscope is a further step toward an all-purpose laser excitation source for multimodal microscopy.
- 27 July 2018
- Published by AIP Publishing in APL Photonics
- Vol. 3 (9) , 092406
Open AccessInvited Article: Coherent Raman and mid-IR microscopy using shaped pulses in a single-beam setup
The possibility to exploit shaped ultrabroadband laser pulses for molecular coherent control offers a unique implementation of numerous nonlinear spectroscopic methods in one setup. Nonlinear processes, such as coherent Raman microscopy, second harmonic generation, or two-photon fluorescence, which have been applied in many different applications in both the material and life sciences, can be selectively addressed and optimized just by changing the phase imprinted by a programmable pulse shaper. Here, the experimental realization of this concept for multimodal nonlinear microscopy is discussed and the successful implementation of adaptive spectral focussing schemes not only for nonlinear Raman but also for difference frequency generation based mid-infrared (Mid-IR) spectroscopy using a single broadband pulse from a Ti:sapphire laser is shown. Flexible pulse shaping enables tuning of the resonance frequency and the spectral width of the excitation. By variation of the instantaneous frequency difference and the amount of chirp, the experiment can be optimized to achieve high resolution spectroscopy reaching up to 20 cm−1. Matching the resolution of the experiment with the linewidths of the sample on the other hand optimizes the contrast for imaging at high signal levels. The combination and flexible switching between Raman or mid-IR excitation for spectroscopy and microscopy is demonstrated on alkynes, polymer films, and skin tissue. The simple addition of this complementary modality to an existing nonlinear microscope is a further step toward an all-purpose laser excitation source for multimodal microscopy.
- 23 April 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (9) , 2054-2057
Flexible and broadly tunable infrared light source based on shaped sub-10-fs pulses for a multimodal microscopy setup
We present a versatile approach for mid-infrared spectroscopy through the flexible control of a difference-frequency-generation (DFG) process by femtosecond (fs) pulse shaping and spectral focusing. Based on a broadband sub-10-fs oscillator, the spectral position and spectral resolution can be independently selected within the molecular fingerprint region of more than . A spectral resolution better than can be achieved, which depends solely on the pulse shaper configuration. An absorption experiment on a polystyrene reference sample finally validates the concept and opens the door for an additional modality in nonlinear multimodal microscopy setups.- 23 April 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (9) , 2054-2057
Flexible and broadly tunable infrared light source based on shaped sub-10-fs pulses for a multimodal microscopy setup
We present a versatile approach for mid-infrared spectroscopy through the flexible control of a difference-frequency-generation (DFG) process by femtosecond (fs) pulse shaping and spectral focusing. Based on a broadband sub-10-fs oscillator, the spectral position and spectral resolution can be independently selected within the molecular fingerprint region of more than . A spectral resolution better than can be achieved, which depends solely on the pulse shaper configuration. An absorption experiment on a polystyrene reference sample finally validates the concept and opens the door for an additional modality in nonlinear multimodal microscopy setups.- 13 February 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10490, 6
Towards a continuous glucose monitoring system using tunable quantum cascade lasers
We present a reagent-free approach for long-term continuous glucose monitoring (cgm) of liquid samples using midinfrared absorption spectroscopy. This method could constitute an alternative to enzymatic glucose sensors in order to manage the widespread disease of Diabetes. In order to acquire spectra of the liquid specimen, we use a spectrally tunable external-cavity (EC-) quantum cascade laser (QCL) as radiation source in combination with a fiber-based in vitro sensor setup. Hereby we achieve a glucose sensitivity in pure glucose solutions of 3 mg/dL (RMSEP). Furthermore, the spectral tunability of the EC-QCL enables us to discriminate glucose from other molecules. We exemplify this by detecting glucose among other saccharides with an accuracy of 8 mg/dL (within other monosaccharides, RMSEVC) and 14 mg/dL (within other mono- and disaccharides, RMSECV). Moreover, we demonstrate a characterization of the significance of each wavenumber for an accurate prediction of glucose among other saccharides using an evolutionary algorithm. We show, that by picking 10 distinct wavenumbers we can achieve comparable accuracies to the use of a complete spectrum.
- 13 February 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10490, 6
Towards a continuous glucose monitoring system using tunable quantum cascade lasers
We present a reagent-free approach for long-term continuous glucose monitoring (cgm) of liquid samples using midinfrared absorption spectroscopy. This method could constitute an alternative to enzymatic glucose sensors in order to manage the widespread disease of Diabetes. In order to acquire spectra of the liquid specimen, we use a spectrally tunable external-cavity (EC-) quantum cascade laser (QCL) as radiation source in combination with a fiber-based in vitro sensor setup. Hereby we achieve a glucose sensitivity in pure glucose solutions of 3 mg/dL (RMSEP). Furthermore, the spectral tunability of the EC-QCL enables us to discriminate glucose from other molecules. We exemplify this by detecting glucose among other saccharides with an accuracy of 8 mg/dL (within other monosaccharides, RMSEVC) and 14 mg/dL (within other mono- and disaccharides, RMSECV). Moreover, we demonstrate a characterization of the significance of each wavenumber for an accurate prediction of glucose among other saccharides using an evolutionary algorithm. We show, that by picking 10 distinct wavenumbers we can achieve comparable accuracies to the use of a complete spectrum.
- Open Access
- 15 December 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (36) , 10318-10322
Temporal resolution beyond the average pulse duration in shaped noisy-pulse transient absorption spectroscopy
In time-resolved spectroscopy, it is a widespread belief that the temporal resolution is determined by the laser pulse duration. Recently, it was observed and shown that partially coherent laser pulses as they are provided by free-electron-laser (FEL) sources offer an alternative route to reach a temporal resolution below the average pulse duration. Here, we demonstrate the generation of partially coherent light in the laboratory like we observe it at FELs. We present the successful implementation of such statistically fluctuating pulses by using the pulse-shaping technique. These pulses exhibit an average pulse duration about 10 times larger than their bandwidth limit. The shaped pulses are then applied to transient-absorption measurements in the dye IR144. Despite the noisy characteristics of the laser pulses, features in the measured absorption spectra occurring on time scales much faster than the average pulse duration are resolved, thus proving the universality of the described noisy-pulse concept.
- 15 December 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (36) , 10318-10322
Open AccessTemporal resolution beyond the average pulse duration in shaped noisy-pulse transient absorption spectroscopy
In time-resolved spectroscopy, it is a widespread belief that the temporal resolution is determined by the laser pulse duration. Recently, it was observed and shown that partially coherent laser pulses as they are provided by free-electron-laser (FEL) sources offer an alternative route to reach a temporal resolution below the average pulse duration. Here, we demonstrate the generation of partially coherent light in the laboratory like we observe it at FELs. We present the successful implementation of such statistically fluctuating pulses by using the pulse-shaping technique. These pulses exhibit an average pulse duration about 10 times larger than their bandwidth limit. The shaped pulses are then applied to transient-absorption measurements in the dye IR144. Despite the noisy characteristics of the laser pulses, features in the measured absorption spectra occurring on time scales much faster than the average pulse duration are resolved, thus proving the universality of the described noisy-pulse concept.
- 8 December 2015
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 112 (51) , 15613-15618
Signatures and control of strong-field dynamics in a complex system
Significance: Using intense lasers to control complex molecules is a long-held dream in science. In this article, we develop a physics concept for measuring and controlling the quantum states of complex molecules by strong laser fields. We show that, in particular, the quantum-mechanical phase of excited molecular states can be manipulated by the intense laser, a key quantity for full (amplitude and phase) control of molecular quantum states. With the help of time- and intensity-resolved absorption spectroscopy experiments, we apply this idea to the dynamics of a large dye molecule in solution. The demonstrated phase-control concept thus represents a major leap toward the ultimate goal of laser chemistry.
- 8 December 2015
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 112 (51) , 15613-15618
Signatures and control of strong-field dynamics in a complex system
Significance: Using intense lasers to control complex molecules is a long-held dream in science. In this article, we develop a physics concept for measuring and controlling the quantum states of complex molecules by strong laser fields. We show that, in particular, the quantum-mechanical phase of excited molecular states can be manipulated by the intense laser, a key quantity for full (amplitude and phase) control of molecular quantum states. With the help of time- and intensity-resolved absorption spectroscopy experiments, we apply this idea to the dynamics of a large dye molecule in solution. The demonstrated phase-control concept thus represents a major leap toward the ultimate goal of laser chemistry.