XHXiaoxuan He

Xiaoxuan He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaoxuan He has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Universal modes: Calibration‐free time‐interleaved acquisition of modes

    by Simon Schmidt, Xiaoxuan He, Gregory J. Metzger

    Purpose: To introduce universal modes by applying the universal pulse concept to time‐interleaved acquisition of modes (TIAMO), thereby achieving calibration‐free inhomogeneity mitigation for body imaging at ultra‐high fields.Methods: Two databases of different RF arrays were used to demonstrate the feasibility of universal modes. The first comprised 31 cardiac in vivo data sets acquired at 7T while the second consisted of 6 simulated 10.5T pelvic data sets. Subject‐specific solutions and universal modes were computed and subsequently evaluated alongside predefined default modes. For the cardiac database, subdivision into subpopulations was investigated. The optimization was performed using least‐squares (LS) TIAMO and acquisition modes optimized for refocused echoes (AMORE). Finally, universal modes based on simulated pelvis data were applied in vivo at 10.5T.Results: In all studied cases, the universal modes yield improvements over the predefined default modes of up to 51% (cardiac) and 30% (pelvic) in terms of median excitation error when using two modes. The subpopulation‐specific cardiac solutions revealed a further improvement of universal modes at the expense of increased errors when applied outside the appropriate subpopulation. Direct application of simulation‐based universal modes in vivo resulted in up to a 14% reduction in excitation error compared to default modes and up to a 34% reduction in peak 10 g local specific absorption rate (SAR) compared to subject‐specific solutions.Conclusions: Universal modes are feasible for calibration‐free inhomogeneity mitigation at ultra‐high fields. In addition, simulation‐based solutions can be applied directly in vivo, eliminating the need for large in vivo databases.


  • Open Access

    Improved 1H body imaging at 10.5 T: Validation and VOP‐enabled imaging in vivo with a 16‐channel transceiver dipole array

    by Simon Schmidt, M. Arcan Ertürk, Xiaoxuan He, Tobey Haluptzok, Yiğitcan Eryaman, Gregory J. Metzger

    Purpose: To increase the RF coil performance and RF management for body imaging at 10.5 T by validating and evaluating a high‐density 16‐channel transceiver array, implementing virtual observation points (VOPs), and demonstrating specific absorption rate (SAR) constrained imaging in vivo.Methods: The inaccuracy of the electromagnetic model of the array was quantified based on B1+ and SAR data. Inter‐subject variability was estimated using a new approach based on the relative SAR deviation of different RF shims between human body models. The pTx performance of the 16‐channel array was assessed in simulation by comparison to a previously demonstrated 10‐channel array. In vivo imaging of the prostate was performed demonstrating SAR‐constrained static RF shimming and acquisition modes optimized for refocused echoes (AMORE).Results: The model inaccuracy of 29% and the inter‐subject variability of 85% resulted in a total safety factor of 1.91 for pelvis studies. For renal and cardiac imaging, inter‐subject variabilities of 121% and 141% lead to total safety factors of 2.25 and 2.45, respectively. The shorter wavelength at 10.5 T supported the increased element density of the 16‐channel array which in turn outperformed the 10‐channel version for all investigated metrics. Peak 10 g local SAR reduction of more than 25% without a loss of image quality was achieved in vivo, allowing a theoretical improvement in measurement efficiency of up to 66%.Conclusions: By validating and characterizing a 16‐channel dipole transceiver array, this work demonstrates, for the first time, a VOP‐enabled RF coil for human torso imaging enabling increased pTx performance at 10.5 T.


  • Open Access

    Towards Calibrated Hyper-Sphere Representation via Distribution Overlap Coefficient for Long-tailed Learning

    by Hualiang Wang, Siming Fu, Xiaoxuan He, Hangxiang Fang, Zuozhu Liu, Haoji Hu

    Long-tailed learning aims to tackle the crucial challenge that head classes dominate the training procedure under severe class imbalance in real-world scenarios. However, little attention has been given to how to quantify the dominance severity of head classes in the representation space. Motivated by this, we generalize the cosine-based classifiers to a von Mises-Fisher (vMF) mixture model, denoted as vMF classifier, which enables to quantitatively measure representation quality upon the hyper-sphere space via calculating distribution overlap coefficient. To our knowledge, this is the first work to measure representation quality of classifiers and features from the perspective of distribution overlap coefficient. On top of it, we formulate the inter-class discrepancy and class-feature consistency loss terms to alleviate the interference among the classifier weights and align features with classifier weights. Furthermore, a novel post-training calibration algorithm is devised to zero-costly boost the performance via inter-class overlap coefficients. Our method outperforms previous work with a large margin and achieves state-of-the-art performance on long-tailed image classification, semantic segmentation, and instance segmentation tasks (e.g., we achieve 55.0\% overall accuracy with ResNetXt-50 in ImageNet-LT). Our code is available at https://github.com/VipaiLab/vMF\_OP.

  • Open Access

    A workflow for predicting temperature increase at the electrical contacts of deep brain stimulation electrodes undergoing MRI

    by Alireza Sadeghi‐Tarakameh, Nur Izzati Huda Zulkarnain, Xiaoxuan He, Ergin Atalar, Noam Harel, Yigitcan Eryaman

    Purpose: The purpose of this study is to present a workflow for predicting the radiofrequency (RF) heating around the contacts of a deep brain stimulation (DBS) lead during an MRI scan.Methods: The induced RF current on the DBS lead accumulates electric charge on the metallic contacts, which may cause a high local specific absorption rate (SAR), and therefore, heating. The accumulated charge was modeled by imposing a voltage boundary condition on the contacts in a quasi‐static electromagnetic (EM) simulation allowing thermal simulations to be performed with the resulting SAR distributions. Estimating SAR and temperature increases from a lead in vivo through EM simulation is not practical given anatomic differences and variations in lead geometry. To overcome this limitation, a new parameter, transimpedance, was defined to characterize a given lead. By combining the transimpedance, which can be measured in a single calibration scan, along with MR‐based current measurements of the lead in a unique orientation and anatomy, local heating can be estimated. Heating determined with this approach was compared with results from heating studies of a commercial DBS electrode in a gel phantom with different lead configurations to validate the proposed method.Results: Using data from a single calibration experiment, the transimpedance of a commercial DBS electrode (directional lead, Infinity DBS system, Abbott Laboratories, Chicago, IL) was determined to be 88 Ω. Heating predictions using the DBS transimpedance and rapidly acquired MR‐based current measurements in 26 different lead configurations resulted in a <23% (on average 11.3%) normalized root‐mean‐square error compared to experimental heating measurements during RF scans.Conclusion: In this study, a workflow consisting of an MR‐based current measurement on the DBS lead and simple quasi‐static EM/thermal simulations to predict the temperature increase around a DBS electrode undergoing an MRI scan is proposed and validated using a commercial DBS electrode.


  • Open Access

    Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE)

    by Xiaoxuan He, Simon Schmidt, Štefan Zbýň, Tobey Haluptzok, Steen Moeller, Gregory J. Metzger

    Purpose: To develop and evaluate a novel RF shimming optimization strategy tailored to improve the transmit efficiency in turbo spin echo imaging when performing time‐interleaved acquisition of modes (TIAMO) at ultrahigh fields.Theory and Methods: A nonlocalized efficiency shimming cost function is proposed and extended to perform TIAMO using acquisition modes optimized for refocused echoes (AMORE). The nonlocalized efficiency shimming was demonstrated in brain and knee imaging at 7 Tesla. Phantom and in vivo torso imaging studies were performed to compare the performance between AMORE and previously proposed TIAMO mode optimizations with and without localized constraints in turbo spin echo and gradient echo acquisitions.Results: The proposed nonlocalized efficiency RF shimming produced a circularly polarized‐like field with fewer signal dropouts in the brain and knee. For larger targets, AMORE was used and required a significantly lower transmitter voltage to produce a similar contrast to existing TIAMO mode design approaches for turbo spin echo as well as gradient echo acquisitions. In vivo, AMORE effectively reduced signal dropout in the interior torso while providing more uniform contrast with reduced transmit power. A local constraint further improved performance for a target region while maintaining performance in the larger FOV.Conclusion: AMORE based on the presented nonlocalized efficiency shimming cost function demonstrated improved contrast and SNR uniformity as well as increased transmit efficiency for both gradient echo and turbo spin echo acquisitions.


  • Parallel transmit optimized 3D composite adiabatic spectral‐spatial pulse for spectroscopy

    by Xiaoxuan He, Edward J. Auerbach, Michael Garwood, Naoharu Kobayashi, Xiaoping Wu, Gregory J. Metzger

    Purpose: To develop a 3D composite adiabatic spectral‐spatial pulse for refocusing in spin‐echo spectroscopy acquisitions and to compare its performance against standard acquisition methods.Methods: A 3D composite adiabatic pulse was designed by modulating a train of parallel transmit–optimized 2D subpulses with an adiabatic envelope. The spatial and spectral profiles were simulated and validated by experiments to demonstrate the feasibility of the design in both single and double spin‐echo spectroscopy acquisitions. Phantom and in vivo studies were performed to evaluate the pulse performance and compared with semi‐LASER with respect to localization performance, sequence timing, signal suppression, and specific absorption rate.Results: Simultaneous 2D spatial localization with water and lipid suppression was achieved with the designed refocusing pulse, allowing high‐quality spectra to be acquired with shorter minimum TE/TR, reduced SAR, as well as adaptation to spatially varying B0 and field inhomogeneities in both prostate and brain studies.Conclusion: The proposed composite pulse can serve as a more SAR efficient alternative to conventional localization methods such as semi‐LASER at ultrahigh field for spin echo–based spectroscopy studies. Subpulse parallel‐transmit optimization provides the flexibility to manage the tradeoff among multiple design criteria to accommodate different field strengths and applications.


  • First in‐vivo human imaging at 10.5T: Imaging the body at 447 MHz

    by Xiaoxuan He, M. Arcan Ertürk, Andrea Grant, Xiaoping Wu, Russell L. Lagore, Lance DelaBarre, Yiğitcan Eryaman, Gregor Adriany, Eddie J. Auerbach, Pierre‐François Van de Moortele, et al.

    Purpose: To investigate the feasibility of imaging the human torso and to evaluate the performance of several radiofrequency (RF) management strategies at 10.5T.Methods: Healthy volunteers were imaged on a 10.5T whole‐body scanner in multiple target anatomies, including the prostate, hip, kidney, liver, and heart. Phase‐only shimming and spoke pulses were used to demonstrate their performance in managing the inhomogeneity present at 447 MHz. Imaging protocols included both qualitative and quantitative acquisitions to show the feasibility of imaging with different contrasts.Results: High‐quality images were acquired and demonstrated excellent overall contrast and signal‐to‐noise ratio. The experimental results matched well with predictions and suggested good translational capabilities of the RF management strategies previously developed at 7T. Phase‐only shimming provided increased efficiency, but showed pronounced limitations in homogeneity, demonstrating the need for the increased degrees of freedom made possible through single‐ and multispoke RF pulse design.Conclusion: The first in‐vivo human imaging was successfully performed at 10.5T using previously developed RF management strategies. Further improvement in RF coils, transmit chain, and full integration of parallel transmit functionality are needed to fully realize the benefits of 10.5T.


  • Open Access

    Acupuncture-induced changes in functional connectivity of the primary somatosensory cortex varied with pathological stages of Bell’s palsy

    by Xiaoxuan He, Yifang Zhu, Chuanfu Li, Kyungmo Park, Abdalla Z. Mohamed, Hongli Wu, Chunsheng Xu, Wei Zhang, Linying Wang, Jun Yang, et al.

    Bell’s palsy is the most common cause of acute facial nerve paralysis. In China, Bell’s palsy is frequently treated with acupuncture. However, its efficacy and underlying mechanism are still controversial. In this study, we used functional MRI to investigate the effect of acupuncture on the functional connectivity of the brain in Bell’s palsy patients and healthy individuals. The patients were further grouped according to disease duration and facial motor performance. The results of resting-state functional MRI connectivity show that acupuncture induces significant connectivity changes in the primary somatosensory region of both early and late recovery groups, but no significant changes in either the healthy control group or the recovered group. In the recovery group, the changes also varied with regions and disease duration. Therefore, we propose that the effect of acupuncture stimulation may depend on the functional connectivity status of patients with Bell’s palsy.