Universal modes: Calibration‐free time‐interleaved acquisition of modes
Open Access
- 1 February 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (1) , 43-56
Abstract
Purpose: To introduce universal modes by applying the universal pulse concept to time‐interleaved acquisition of modes (TIAMO), thereby achieving calibration‐free inhomogeneity mitigation for body imaging at ultra‐high fields.Methods: Two databases of different RF arrays were used to demonstrate the feasibility of universal modes. The first comprised 31 cardiac in vivo data sets acquired at 7T while the second consisted of 6 simulated 10.5T pelvic data sets. Subject‐specific solutions and universal modes were computed and subsequently evaluated alongside predefined default modes. For the cardiac database, subdivision into subpopulations was investigated. The optimization was performed using least‐squares (LS) TIAMO and acquisition modes optimized for refocused echoes (AMORE). Finally, universal modes based on simulated pelvis data were applied in vivo at 10.5T.Results: In all studied cases, the universal modes yield improvements over the predefined default modes of up to 51% (cardiac) and 30% (pelvic) in terms of median excitation error when using two modes. The subpopulation‐specific cardiac solutions revealed a further improvement of universal modes at the expense of increased errors when applied outside the appropriate subpopulation. Direct application of simulation‐based universal modes in vivo resulted in up to a 14% reduction in excitation error compared to default modes and up to a 34% reduction in peak 10 g local specific absorption rate (SAR) compared to subject‐specific solutions.Conclusions: Universal modes are feasible for calibration‐free inhomogeneity mitigation at ultra‐high fields. In addition, simulation‐based solutions can be applied directly in vivo, eliminating the need for large in vivo databases.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (P41 EB027061, R01 EB029985)
This publication has 22 references indexed in Scilit:
- Dynamically applied B1+ shimming solutions for non‐contrast enhanced renal angiography at 7.0 teslaMagnetic Resonance in Medicine, 2012
- Time‐interleaved acquisition of modes: An analysis of SAR and image contrast implicationsMagnetic Resonance in Medicine, 2011
- Tailored excitation in 3D with spiral nonselective (SPINS) RF pulsesMagnetic Resonance in Medicine, 2011
- kT‐points: Short three‐dimensional tailored RF pulses for flip‐angle homogenization over an extended volumeMagnetic Resonance in Medicine, 2011
- RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high‐field MRIMagnetic Resonance in Medicine, 2010
- Initial results of cardiac imaging at 7 teslaMagnetic Resonance in Medicine, 2008
- Whole‐body imaging at 7T: Preliminary resultsMagnetic Resonance in Medicine, 2008
- Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurementsMagnetic Resonance in Medicine, 2008
- Fast‐kzthree‐dimensional tailored radiofrequency pulse for reducedB1inhomogeneityMagnetic Resonance in Medicine, 2006
- Transmit and receive transmission line arrays for 7 Tesla parallel imagingMagnetic Resonance in Medicine, 2005