Manex Barrenetxea
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Manex Barrenetxea has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Ignacio Zubimendi
Ingeteam Power Technology, Zamudio, Spain
2 shared publicationsIgor Baraia
University of Mondragon, Faculty of Engineering, Arrasate, Spain
2 shared publicationsIgor Larrazabal
Ingeteam Power Technology, Zamudio, Spain
2 shared publications- Jone Ugarte Valdivielso
Electronics and Computing Science Department, Mondragon Unibertsitatea, Arrasate, Spain
2 shared publications - Jose Ignacio Aizpurua
Department of Computer Science and Artificial Intelligence University of the Basque Country (EHU) Donostia‐San Sebastian Spain
2 shared publications Ander Goikoetxea
1 shared publication
Latest Publications
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (1) , 1-11
Blind Efficient Method for Optimizing Jiles–Atherton Model Parameters
We introduce a novel blind optimization method for determining the parameters of the Jiles–Atherton model of hysteresis, eliminating the need for user-provided initial guesses or search spaces. A carefully designed initialization procedure combined with a standard optimizer yields a high-performing, practical method for parameter estimation. Validation against a theoretical benchmark recovers ground-truth parameters in under half a minute with negligible error (relative error < 4 $\times$ 10−8). When applied to the TEAM32 electrical steel experimental benchmark, our method achieved superior accuracy than previously reported fittings, also converging in under half a minute. Consistently robust performance is further demonstrated across diverse systems, including soft ferrites, nanocrystalline alloys, and magnetostrictive compounds. The presented blind approach offers new insights into magnetic material characterization and is deployed as an automated tool for hysteresis analysis. It advances both fundamental understanding and practical applications by demonstrating the Jiles–Atherton model’s capability to describe anisotropic materials and by revealing its inherent limitations.
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 62 (1) , 1-11
Blind Efficient Method for Optimizing Jiles–Atherton Model Parameters
We introduce a novel blind optimization method for determining the parameters of the Jiles–Atherton model of hysteresis, eliminating the need for user-provided initial guesses or search spaces. A carefully designed initialization procedure combined with a standard optimizer yields a high-performing, practical method for parameter estimation. Validation against a theoretical benchmark recovers ground-truth parameters in under half a minute with negligible error (relative error < 4 $\times$ 10−8). When applied to the TEAM32 electrical steel experimental benchmark, our method achieved superior accuracy than previously reported fittings, also converging in under half a minute. Consistently robust performance is further demonstrated across diverse systems, including soft ferrites, nanocrystalline alloys, and magnetostrictive compounds. The presented blind approach offers new insights into magnetic material characterization and is deployed as an automated tool for hysteresis analysis. It advances both fundamental understanding and practical applications by demonstrating the Jiles–Atherton model’s capability to describe anisotropic materials and by revealing its inherent limitations.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2275-2285
Uncertainty Distribution Assessment of Jiles-Atherton Parameter Estimation for Inrush Current Studies
Transformers are one of the key assets in AC distribution grids and renewable power integration. During transformer energization inrush currents appear, which lead to transformer degradation and can cause grid instability events. These inrush currents are a consequence of the transformer's magnetic core saturation during its connection to the grid. Transformer cores are normally modelled by the Jiles-Atherton (JA) model which contains five parameters. These parameters can be estimated by metaheuristic-based search algorithms. The parameter initialization of these algorithms plays an important role in the algorithm convergence. The most popular strategy used for JA parameter initialization is a random uniform distribution. However, techniques such as parameter initialization by Probability Density Functions (PDFs) have shown to improve accuracy over random methods. In this context, this research work presents a framework to assess the impact of different parameter initialization strategies on the performance of the JA parameter estimation for inrush current studies. Depending on available data and expert knowledge, uncertainty levels are modelled with different PDFs. Moreover, three different metaheuristic-search algorithms are employed on two different core materials and their accuracy and computational time are compared. Results show an improvement in the accuracy and computational time of the metaheuristic-based algorithms when PDF parameter initialization is used.
- 13 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (4) , 2275-2285
Uncertainty Distribution Assessment of Jiles-Atherton Parameter Estimation for Inrush Current Studies
Transformers are one of the key assets in AC distribution grids and renewable power integration. During transformer energization inrush currents appear, which lead to transformer degradation and can cause grid instability events. These inrush currents are a consequence of the transformer's magnetic core saturation during its connection to the grid. Transformer cores are normally modelled by the Jiles-Atherton (JA) model which contains five parameters. These parameters can be estimated by metaheuristic-based search algorithms. The parameter initialization of these algorithms plays an important role in the algorithm convergence. The most popular strategy used for JA parameter initialization is a random uniform distribution. However, techniques such as parameter initialization by Probability Density Functions (PDFs) have shown to improve accuracy over random methods. In this context, this research work presents a framework to assess the impact of different parameter initialization strategies on the performance of the JA parameter estimation for inrush current studies. Depending on available data and expert knowledge, uncertainty levels are modelled with different PDFs. Moreover, three different metaheuristic-search algorithms are employed on two different core materials and their accuracy and computational time are compared. Results show an improvement in the accuracy and computational time of the metaheuristic-based algorithms when PDF parameter initialization is used.
- 21 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (3) , 2933-2942
Simple and Affordable Method for Fast Transient Measurements of SiC Devices
The measurement of fast voltage and current transients of SiC devices requires high bandwidth probes. Commercially available voltage and current probes can be expensive and in addition, the delay introduced by them must be compensated to achieve a proper time alignment (de-skew). Determining this de-skewing value is not a trivial task. In this paper, a simple and affordable measurement method is presented for the simultaneous measurement of the voltage and current transients of SiC devices. The voltage is measured by means of a high bandwidth RC attenuator while the current is estimated from the voltage drop in the stray inductance of the switching loop. Since both voltages are measured with two equal and matched high bandwidth passive voltage probes there is no need to apply any deskew. This is one of the most important advantages of the method. The presented method is experimentally evaluated and used for the estimation of energy switching losses in the tested SiC - MOSFET.
- 21 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 35 (3) , 2933-2942
Simple and Affordable Method for Fast Transient Measurements of SiC Devices
The measurement of fast voltage and current transients of SiC devices requires high bandwidth probes. Commercially available voltage and current probes can be expensive and in addition, the delay introduced by them must be compensated to achieve a proper time alignment (de-skew). Determining this de-skewing value is not a trivial task. In this paper, a simple and affordable measurement method is presented for the simultaneous measurement of the voltage and current transients of SiC devices. The voltage is measured by means of a high bandwidth RC attenuator while the current is estimated from the voltage drop in the stray inductance of the switching loop. Since both voltages are measured with two equal and matched high bandwidth passive voltage probes there is no need to apply any deskew. This is one of the most important advantages of the method. The presented method is experimentally evaluated and used for the estimation of energy switching losses in the tested SiC - MOSFET.
- Open Access
Medium-Voltage AC Static Switch Solution to Feed Neutral Section in a High-Speed Railway System
A high-speed train (HST) is a single-phase load supplied by a three-phase AC grid. The HST produces unbalanced three-line currents affecting the power quality of the grid. To balance the asymmetries on average, railway feeding sections are supplied that rotate the three phases of the grid. An electric isolation segment, called the neutral section (NS), between different sections is necessary. The HST must pass through this 1.6 km NS without power supply. In this paper, a medium-voltage AC static switch solution to feed the high-speed train in the NS is proposed. Thyristor technology is selected to design the 25 KVAC static switch. A medium-voltage power electronics procedure design is proposed to ensure proper operation in the final application. An NS operation is analyzed to identify impacts within the electric system and solution requirements are developed. Then, a low-scale prototype is used to experimentally validate the solution based on thyristor technology and the medium-voltage AC static switch is designed. Limitations on power and voltage at the Mondragon University Medium-Voltage Laboratory do not allow testing of the AC static switch at nominal conditions. A partial test procedure to test sections of the AC static switch is proposed and applied to validate the solution. Finally, experimental results for the Cordoba–Malaga (Spain) high-speed railway in real conditions with an HST crossing the NS at 300 km/h are shown.
Open AccessMedium-Voltage AC Static Switch Solution to Feed Neutral Section in a High-Speed Railway System
A high-speed train (HST) is a single-phase load supplied by a three-phase AC grid. The HST produces unbalanced three-line currents affecting the power quality of the grid. To balance the asymmetries on average, railway feeding sections are supplied that rotate the three phases of the grid. An electric isolation segment, called the neutral section (NS), between different sections is necessary. The HST must pass through this 1.6 km NS without power supply. In this paper, a medium-voltage AC static switch solution to feed the high-speed train in the NS is proposed. Thyristor technology is selected to design the 25 KVAC static switch. A medium-voltage power electronics procedure design is proposed to ensure proper operation in the final application. An NS operation is analyzed to identify impacts within the electric system and solution requirements are developed. Then, a low-scale prototype is used to experimentally validate the solution based on thyristor technology and the medium-voltage AC static switch is designed. Limitations on power and voltage at the Mondragon University Medium-Voltage Laboratory do not allow testing of the AC static switch at nominal conditions. A partial test procedure to test sections of the AC static switch is proposed and applied to validate the solution. Finally, experimental results for the Cordoba–Malaga (Spain) high-speed railway in real conditions with an HST crossing the NS at 300 km/h are shown.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Design of a novel modular energy conversion scheme for DC offshore wind farms
Offshore wind farms provide benefits over onshore farms in terms of the amount of generated energy and environmental impact. Cost efficient energy transmission is one of the challenges of those installations. In this context direct connection of parallel connected DC wind turbines to the transmission line is a promising solution. Modular DC-DC converters are an attractive solution for the direct connection of the DC wind turbines to the transmission line. In addition, the phase-shifted full-bridge converter (PSFB) is a good candidate to form simple, efficient and reliable high voltage modular DC-DC converters for offshore DC networks. This paper proposes a novel energy conversion scheme for the direct connection of the DC wind turbines to the transmission line. Design criteria for the phase-shifted full-bridge converter and the medium frequency transformer are described and a modular energy conversion scheme is sized to operate with 10MW offshore wind turbines and 300kV transmission voltage.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Design of a novel modular energy conversion scheme for DC offshore wind farms
Offshore wind farms provide benefits over onshore farms in terms of the amount of generated energy and environmental impact. Cost efficient energy transmission is one of the challenges of those installations. In this context direct connection of parallel connected DC wind turbines to the transmission line is a promising solution. Modular DC-DC converters are an attractive solution for the direct connection of the DC wind turbines to the transmission line. In addition, the phase-shifted full-bridge converter (PSFB) is a good candidate to form simple, efficient and reliable high voltage modular DC-DC converters for offshore DC networks. This paper proposes a novel energy conversion scheme for the direct connection of the DC wind turbines to the transmission line. Design criteria for the phase-shifted full-bridge converter and the medium frequency transformer are described and a modular energy conversion scheme is sized to operate with 10MW offshore wind turbines and 300kV transmission voltage.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis, comparison and selection of DC-DC converters for a novel modular energy conversion scheme for DC offshore wind farms
Offshore wind farms provide benefits over onshore farms in terms of the amount of generated energy and environmental impact. Cost efficient energy transmission is one of the challenges of such installations. In this context, direct connection of DC wind turbines to the transmission line is a promising solution. This paper proposes a novel energy conversion scheme for the direct connection of the DC wind turbines to the transmission line. In addition, a brief comparison between two DC-DC converters is presented to establish the most suitable topology for the modular DC-DC converter required by the proposed energy conversion scheme.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis, comparison and selection of DC-DC converters for a novel modular energy conversion scheme for DC offshore wind farms
Offshore wind farms provide benefits over onshore farms in terms of the amount of generated energy and environmental impact. Cost efficient energy transmission is one of the challenges of such installations. In this context, direct connection of DC wind turbines to the transmission line is a promising solution. This paper proposes a novel energy conversion scheme for the direct connection of the DC wind turbines to the transmission line. In addition, a brief comparison between two DC-DC converters is presented to establish the most suitable topology for the modular DC-DC converter required by the proposed energy conversion scheme.