Abstract
The measurement of fast voltage and current transients of SiC devices requires high bandwidth probes. Commercially available voltage and current probes can be expensive and in addition, the delay introduced by them must be compensated to achieve a proper time alignment (de-skew). Determining this de-skewing value is not a trivial task. In this paper, a simple and affordable measurement method is presented for the simultaneous measurement of the voltage and current transients of SiC devices. The voltage is measured by means of a high bandwidth RC attenuator while the current is estimated from the voltage drop in the stray inductance of the switching loop. Since both voltages are measured with two equal and matched high bandwidth passive voltage probes there is no need to apply any deskew. This is one of the most important advantages of the method. The presented method is experimentally evaluated and used for the estimation of energy switching losses in the tested SiC - MOSFET.
Funding Information
  • Eusko Jaurlaritza (KK-2018/00064)
  • Universidad-Empresa (UE2017-09)

This publication has 7 references indexed in Scilit: