Aleksandar Tadić
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aleksandar Tadić has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Harbaljit S. Sohal
Paradromics,inc, 4030 W Braker Lane, ste 250, Austin, UNITED STATES
3 shared publications - Ingrid McNamara
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications - Kevin Michael Boergens
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications - Kunal Sahasrabuddhe
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications - Malgorzata Straka
Medtronic Neuromodulation, Minneapolis, USA
3 shared publications - Matthew R. Angle
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications
Latest Publications
- 11 June 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 045008
Laser ablation of the pia mater for insertion of high-density microelectrode arrays in a translational sheep model
Objective . The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain–computer interfaces (BCIs). However, the pia mater can be difficult to penetrate and causes deformation of underlying cortical tissue during insertion of high-density intracortical arrays. This can lead to neuron damage or failed insertions. The development of a method to ease insertion through the pia mater would represent a significant step toward inserting high density intracortical arrays. Approach . Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in translational models to thin the pia mater. Main results . We demonstrate that controlled pia removal with laser ablation over a small area of cortex allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. This procedure allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region. Significance . Laser ablation of the pia reduces insertion forces of high-density arrays with minimal to no acute damage to cortical neurons. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
- 11 June 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 045008
Laser ablation of the pia mater for insertion of high-density microelectrode arrays in a translational sheep model
Objective . The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain–computer interfaces (BCIs). However, the pia mater can be difficult to penetrate and causes deformation of underlying cortical tissue during insertion of high-density intracortical arrays. This can lead to neuron damage or failed insertions. The development of a method to ease insertion through the pia mater would represent a significant step toward inserting high density intracortical arrays. Approach . Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in translational models to thin the pia mater. Main results . We demonstrate that controlled pia removal with laser ablation over a small area of cortex allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. This procedure allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region. Significance . Laser ablation of the pia reduces insertion forces of high-density arrays with minimal to no acute damage to cortical neurons. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
- Top Cited Papers
- 24 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (1) , 015002
The Argo: a high channel count recording system for neural recording in vivo
Objective. Decoding neural activity has been limited by the lack of tools available to record from large numbers of neurons across multiple cortical regions simultaneously with high temporal fidelity. To this end, we developed the Argo system to record cortical neural activity at high data rates. Approach. Here we demonstrate a massively parallel neural recording system based on platinum-iridium microwire electrode arrays bonded to a CMOS voltage amplifier array. The Argo system is the highest channel count in vivo neural recording system, supporting simultaneous recording from 65 536 channels, sampled at 32 kHz and 12-bit resolution. This system was designed for cortical recordings, compatible with both penetrating and surface microelectrodes. Main results. We validated this system through initial bench testing to determine specific gain and noise characteristics of bonded microwires, followed by in-vivo experiments in both rat and sheep cortex. We recorded spiking activity from 791 neurons in rats and surface local field potential activity from over 30 000 channels in sheep. Significance. These are the largest channel count microwire-based recordings in both rat and sheep. While currently adapted for head-fixed recording, the microwire-CMOS architecture is well suited for clinical translation. Thus, this demonstration helps pave the way for a future high data rate intracortical implant.
- 24 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (1) , 015002
Top Cited PapersThe Argo: a high channel count recording system for neural recording in vivo
Objective. Decoding neural activity has been limited by the lack of tools available to record from large numbers of neurons across multiple cortical regions simultaneously with high temporal fidelity. To this end, we developed the Argo system to record cortical neural activity at high data rates. Approach. Here we demonstrate a massively parallel neural recording system based on platinum-iridium microwire electrode arrays bonded to a CMOS voltage amplifier array. The Argo system is the highest channel count in vivo neural recording system, supporting simultaneous recording from 65 536 channels, sampled at 32 kHz and 12-bit resolution. This system was designed for cortical recordings, compatible with both penetrating and surface microelectrodes. Main results. We validated this system through initial bench testing to determine specific gain and noise characteristics of bonded microwires, followed by in-vivo experiments in both rat and sheep cortex. We recorded spiking activity from 791 neurons in rats and surface local field potential activity from over 30 000 channels in sheep. Significance. These are the largest channel count microwire-based recordings in both rat and sheep. While currently adapted for head-fixed recording, the microwire-CMOS architecture is well suited for clinical translation. Thus, this demonstration helps pave the way for a future high data rate intracortical implant.
- Open Access
Laser Ablation of the Pia Mater for Insertion of High-Density Microelectrode Arrays in a Translational Sheep Model
The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain-computer interfaces (BCIs). Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in large mammals to thin the pia mater, the innermost meningeal layer encapsulating the brain. This procedure allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. We demonstrate that controlled pia removal over a small area of cortex allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
Open AccessLaser Ablation of the Pia Mater for Insertion of High-Density Microelectrode Arrays in a Translational Sheep Model
The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain-computer interfaces (BCIs). Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in large mammals to thin the pia mater, the innermost meningeal layer encapsulating the brain. This procedure allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. We demonstrate that controlled pia removal over a small area of cortex allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
- Open Access
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 124706
Development of a voltage controlled resistor for use in a self-balancing resistance bridge
We report on a simple design for a voltage controlled resistor that can operate in a continuous range from ∼50 Ω to over ∼100 kΩ. The device consists of a light emitting diode (LED) placed near a photocell. Varying the voltage across the LED changes its brightness, which, in turn, changes the resistance of the photocell. The resistance of the photoresistor is measured by calibrating the output of a nearby phototransistor against the photoresistor resistance, allowing for an independent measurement of the resistance. The performance of the device is tested in the context of a temperature measuring system involving a Wheatstone bridge.
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 124706
Open AccessDevelopment of a voltage controlled resistor for use in a self-balancing resistance bridge
We report on a simple design for a voltage controlled resistor that can operate in a continuous range from ∼50 Ω to over ∼100 kΩ. The device consists of a light emitting diode (LED) placed near a photocell. Varying the voltage across the LED changes its brightness, which, in turn, changes the resistance of the photocell. The resistance of the photoresistor is measured by calibrating the output of a nearby phototransistor against the photoresistor resistance, allowing for an independent measurement of the resistance. The performance of the device is tested in the context of a temperature measuring system involving a Wheatstone bridge.