Harbaljit S. Sohal
Research Subjects
Harbaljit S. Sohal has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Malgorzata Straka
Medtronic Neuromodulation, Minneapolis, USA
5 shared publications - Aleksandar Tadić
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications - Ingrid McNamara
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications - Kevin Michael Boergens
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications - Kunal Sahasrabuddhe
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications - Matthew R. Angle
Paradromics, Inc., 4030 W Braker Ln, Austin, Texas, 78759, UNITED STATES
3 shared publications
Latest Publications
- Open Access
- 1 April 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (2) , 026030
Electrode sharpness and insertion speed reduce tissue damage near high-density penetrating arrays
Objective. Over the past decade, neural electrodes have played a crucial role in bridging biological tissues with electronic and robotic devices. This study focuses on evaluating the optimal tip profile and insertion speed for effectively implanting Paradromics’ high-density fine microwire arrays (FμA) prototypes into the primary visual cortex (V1) of mice and rats, addressing the challenges associated with the ‘bed-of-nails’ effect and tissue dimpling. Approach. Tissue response was assessed by investigating the impact of electrodes on the blood-brain barrier (BBB) and cellular damage, with a specific emphasis on tailored insertion strategies to minimize tissue disruption during electrode implantation. Main results. Electro-sharpened arrays demonstrated a marked reduction in cellular damage within 50 μm of the electrode tip compared to blunt and angled arrays. Histological analysis revealed that slow insertion speeds led to greater BBB compromise than fast and pneumatic methods. Successful single-unit recordings validated the efficacy of the optimized electro-sharpened arrays in capturing neural activity. Significance. These findings underscore the critical role of tailored insertion strategies in minimizing tissue damage during electrode implantation, highlighting the suitability of electro-sharpened arrays for long-term implant applications. This research contributes to a deeper understanding of the complexities associated with high-channel-count microelectrode array implantation, emphasizing the importance of meticulous assessment and optimization of key parameters for effective integration and minimal tissue disruption. By elucidating the interplay between insertion parameters and tissue response, our study lays a strong foundation for the development of advanced implantable devices with a reduction in reactive gliosis and improved performance in neural recording applications.
- 1 April 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (2) , 026030
Open AccessElectrode sharpness and insertion speed reduce tissue damage near high-density penetrating arrays
Objective. Over the past decade, neural electrodes have played a crucial role in bridging biological tissues with electronic and robotic devices. This study focuses on evaluating the optimal tip profile and insertion speed for effectively implanting Paradromics’ high-density fine microwire arrays (FμA) prototypes into the primary visual cortex (V1) of mice and rats, addressing the challenges associated with the ‘bed-of-nails’ effect and tissue dimpling. Approach. Tissue response was assessed by investigating the impact of electrodes on the blood-brain barrier (BBB) and cellular damage, with a specific emphasis on tailored insertion strategies to minimize tissue disruption during electrode implantation. Main results. Electro-sharpened arrays demonstrated a marked reduction in cellular damage within 50 μm of the electrode tip compared to blunt and angled arrays. Histological analysis revealed that slow insertion speeds led to greater BBB compromise than fast and pneumatic methods. Successful single-unit recordings validated the efficacy of the optimized electro-sharpened arrays in capturing neural activity. Significance. These findings underscore the critical role of tailored insertion strategies in minimizing tissue damage during electrode implantation, highlighting the suitability of electro-sharpened arrays for long-term implant applications. This research contributes to a deeper understanding of the complexities associated with high-channel-count microelectrode array implantation, emphasizing the importance of meticulous assessment and optimization of key parameters for effective integration and minimal tissue disruption. By elucidating the interplay between insertion parameters and tissue response, our study lays a strong foundation for the development of advanced implantable devices with a reduction in reactive gliosis and improved performance in neural recording applications.
- 11 June 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 045008
Laser ablation of the pia mater for insertion of high-density microelectrode arrays in a translational sheep model
Objective . The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain–computer interfaces (BCIs). However, the pia mater can be difficult to penetrate and causes deformation of underlying cortical tissue during insertion of high-density intracortical arrays. This can lead to neuron damage or failed insertions. The development of a method to ease insertion through the pia mater would represent a significant step toward inserting high density intracortical arrays. Approach . Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in translational models to thin the pia mater. Main results . We demonstrate that controlled pia removal with laser ablation over a small area of cortex allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. This procedure allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region. Significance . Laser ablation of the pia reduces insertion forces of high-density arrays with minimal to no acute damage to cortical neurons. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
- 11 June 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 045008
Laser ablation of the pia mater for insertion of high-density microelectrode arrays in a translational sheep model
Objective . The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain–computer interfaces (BCIs). However, the pia mater can be difficult to penetrate and causes deformation of underlying cortical tissue during insertion of high-density intracortical arrays. This can lead to neuron damage or failed insertions. The development of a method to ease insertion through the pia mater would represent a significant step toward inserting high density intracortical arrays. Approach . Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in translational models to thin the pia mater. Main results . We demonstrate that controlled pia removal with laser ablation over a small area of cortex allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. This procedure allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region. Significance . Laser ablation of the pia reduces insertion forces of high-density arrays with minimal to no acute damage to cortical neurons. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
- Top Cited Papers
- 24 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (1) , 015002
The Argo: a high channel count recording system for neural recording in vivo
Objective. Decoding neural activity has been limited by the lack of tools available to record from large numbers of neurons across multiple cortical regions simultaneously with high temporal fidelity. To this end, we developed the Argo system to record cortical neural activity at high data rates. Approach. Here we demonstrate a massively parallel neural recording system based on platinum-iridium microwire electrode arrays bonded to a CMOS voltage amplifier array. The Argo system is the highest channel count in vivo neural recording system, supporting simultaneous recording from 65 536 channels, sampled at 32 kHz and 12-bit resolution. This system was designed for cortical recordings, compatible with both penetrating and surface microelectrodes. Main results. We validated this system through initial bench testing to determine specific gain and noise characteristics of bonded microwires, followed by in-vivo experiments in both rat and sheep cortex. We recorded spiking activity from 791 neurons in rats and surface local field potential activity from over 30 000 channels in sheep. Significance. These are the largest channel count microwire-based recordings in both rat and sheep. While currently adapted for head-fixed recording, the microwire-CMOS architecture is well suited for clinical translation. Thus, this demonstration helps pave the way for a future high data rate intracortical implant.
- 24 February 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (1) , 015002
Top Cited PapersThe Argo: a high channel count recording system for neural recording in vivo
Objective. Decoding neural activity has been limited by the lack of tools available to record from large numbers of neurons across multiple cortical regions simultaneously with high temporal fidelity. To this end, we developed the Argo system to record cortical neural activity at high data rates. Approach. Here we demonstrate a massively parallel neural recording system based on platinum-iridium microwire electrode arrays bonded to a CMOS voltage amplifier array. The Argo system is the highest channel count in vivo neural recording system, supporting simultaneous recording from 65 536 channels, sampled at 32 kHz and 12-bit resolution. This system was designed for cortical recordings, compatible with both penetrating and surface microelectrodes. Main results. We validated this system through initial bench testing to determine specific gain and noise characteristics of bonded microwires, followed by in-vivo experiments in both rat and sheep cortex. We recorded spiking activity from 791 neurons in rats and surface local field potential activity from over 30 000 channels in sheep. Significance. These are the largest channel count microwire-based recordings in both rat and sheep. While currently adapted for head-fixed recording, the microwire-CMOS architecture is well suited for clinical translation. Thus, this demonstration helps pave the way for a future high data rate intracortical implant.
- Open Access
Laser Ablation of the Pia Mater for Insertion of High-Density Microelectrode Arrays in a Translational Sheep Model
The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain-computer interfaces (BCIs). Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in large mammals to thin the pia mater, the innermost meningeal layer encapsulating the brain. This procedure allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. We demonstrate that controlled pia removal over a small area of cortex allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
Open AccessLaser Ablation of the Pia Mater for Insertion of High-Density Microelectrode Arrays in a Translational Sheep Model
The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain-computer interfaces (BCIs). Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in large mammals to thin the pia mater, the innermost meningeal layer encapsulating the brain. This procedure allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. We demonstrate that controlled pia removal over a small area of cortex allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
- 10 July 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (4) , 046003
A novel microwire interface for small diameter peripheral nerves in a chronic, awake murine model
Objective. The vagus nerve has been implicated in a variety of immune responses, and the number of studies using mouse models to unravel key mechanisms has increased. However, as of yet, there is no electrode that can chronically record neural activity from the mouse vagus nerve due to its small diameter. Such recordings are critical to understand the role of these biomarkers for translational research. Approach. In this study, we developed a methodology for surgically implanting the wrappable microwires onto the vagus nerve of mice. Similar to a cuff electrode, we wrapped de-insulated ends of microwires around the vagus nerve and re-insulated them on the nerve with Kwik-Sil. The recording fidelity of the wrappable microwire on the vagus nerve was validated in an acute, anesthetized model by comparing performance to commercially-available electrodes. A chronic, awake mouse model was then developed to record spontaneous compound action potentials (CAPs). Main results. In an acute setting, the wrappable microwire successfully recorded spontaneous CAPs with similar signal-to-noise ratios (SNR) and peak-to-peak amplitude to commercially available electrodes. In chronic, awake recordings, viable SNRs were obtained from the wrappable microwires between 30 and 60 d (n = 8). Weekly impedance measurements showed no correlation with SNR or time, indicating device stability, and the electrodes recorded CAPs for the duration of the recording period. Significance. To the best of our knowledge, this is the first reported chronic, awake neural interface with the mouse vagus nerve. This approach can facilitate clinical translation for bioelectronic medicine in preclinical disease models of interest with the creation of more clinically relevant preclinical models.
- 10 July 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (4) , 046003
A novel microwire interface for small diameter peripheral nerves in a chronic, awake murine model
Objective. The vagus nerve has been implicated in a variety of immune responses, and the number of studies using mouse models to unravel key mechanisms has increased. However, as of yet, there is no electrode that can chronically record neural activity from the mouse vagus nerve due to its small diameter. Such recordings are critical to understand the role of these biomarkers for translational research. Approach. In this study, we developed a methodology for surgically implanting the wrappable microwires onto the vagus nerve of mice. Similar to a cuff electrode, we wrapped de-insulated ends of microwires around the vagus nerve and re-insulated them on the nerve with Kwik-Sil. The recording fidelity of the wrappable microwire on the vagus nerve was validated in an acute, anesthetized model by comparing performance to commercially-available electrodes. A chronic, awake mouse model was then developed to record spontaneous compound action potentials (CAPs). Main results. In an acute setting, the wrappable microwire successfully recorded spontaneous CAPs with similar signal-to-noise ratios (SNR) and peak-to-peak amplitude to commercially available electrodes. In chronic, awake recordings, viable SNRs were obtained from the wrappable microwires between 30 and 60 d (n = 8). Weekly impedance measurements showed no correlation with SNR or time, indicating device stability, and the electrodes recorded CAPs for the duration of the recording period. Significance. To the best of our knowledge, this is the first reported chronic, awake neural interface with the mouse vagus nerve. This approach can facilitate clinical translation for bioelectronic medicine in preclinical disease models of interest with the creation of more clinically relevant preclinical models.
- 13 December 2018
- Published by Springer Nature in Nature Electronics
- Vol. 1 (12) , 620-621
Omnidirectional optogenetic stimulation
- 13 December 2018
- Published by Springer Nature in Nature Electronics
- Vol. 1 (12) , 620-621
Omnidirectional optogenetic stimulation
- Open Access
A wrappable microwire electrode for awake, chronic interfacing with small diameter autonomic peripheral nerves
Bioelectronic medicine requires the ability to monitor and modulate nerve activity in awake patients over time. The vagus nerve is a promising stimulation target, and preclinical models often use mice. However, an awake, chronic mouse vagus nerve interface has yet to be demonstrated. Here, we developed a functional wrappable microwire electrode to chronically interface with the small diameter mouse cervical vagus nerve (∼100 μm). In an acute setting, the wrappable microwire had similar recording performance to commercially available electrodes. A chronic, awake mouse model was then developed to record spontaneous compound action potentials (CAPs). Viable signal-to-noise ratios (SNRs) were obtained from the wrappable microwires between 30 and 60 days (n = 8). Weekly impedance measurements showed no correlation between SNR or time. The wrappable microwires successfully interfaced with small diameter nerves and has been validated in a chronic, awake preclinical model, which can better facilitate clinical translation for bioelectronic medicine.
Open AccessA wrappable microwire electrode for awake, chronic interfacing with small diameter autonomic peripheral nerves
Bioelectronic medicine requires the ability to monitor and modulate nerve activity in awake patients over time. The vagus nerve is a promising stimulation target, and preclinical models often use mice. However, an awake, chronic mouse vagus nerve interface has yet to be demonstrated. Here, we developed a functional wrappable microwire electrode to chronically interface with the small diameter mouse cervical vagus nerve (∼100 μm). In an acute setting, the wrappable microwire had similar recording performance to commercially available electrodes. A chronic, awake mouse model was then developed to record spontaneous compound action potentials (CAPs). Viable signal-to-noise ratios (SNRs) were obtained from the wrappable microwires between 30 and 60 days (n = 8). Weekly impedance measurements showed no correlation between SNR or time. The wrappable microwires successfully interfaced with small diameter nerves and has been validated in a chronic, awake preclinical model, which can better facilitate clinical translation for bioelectronic medicine.