JGJose Luis Rubio Guivernau

Jose Luis Rubio Guivernau

*This is an algorithmically generated author record based on publicly available information.

Jose Luis Rubio Guivernau has a total of 87 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Self-aligned micro-optic integrated photonic platform

    by Aleksandar Jovic, Nuria Sanchez Losilla, Juan Sancho Durá, Kirill Zinoviev, Jose Luis Rubio Guivernau, Eduardo Margallo-Balbás, Massimo Mastrangeli, Grégory Pandraud, Pasqualina M. Sarro

    In this work, we present the fabrication technology of a monolithically integrated photonic platform combining key components for optical coherence tomography (OCT) imaging, thereby including a photonic interferometer, a collimating lens, and a 45° reflecting mirror that directs the light from the interferometer to the collimator. The proposed integration process simplifies the fabrication of an interferometric system and inherently overcomes the complexity of costly alignment procedures while complying with the necessarily stringent optical constraints. Fabricated waveguide characterization shows total optical losses as low as 3 dB, and less than 1 dB of additional loss due to the Si 45° mirror facet. The alignment standard deviation of all components is within 15 nm. The integrated lens profile achieves a divergence angle smaller than 0.7°, which is close to that of a collimator. The proposed photonic platform provides the premise for low-cost and small-footprint single-chip OCT systems.


  • Handheld multi‐modal imaging for point‐of‐care skin diagnosis based on akinetic integrated optics optical coherence tomography

    by Juan Sancho‐Durá, Kirill Zinoviev, Juan Lloret‐Soler, Jose Luis Rubio‐Guviernau, Eduardo Margallo‐Balbás, Wolfgang Drexler

    A handheld skin imaging system with joint optical coherence tomography (OCT) at 1300 nm and digital epiluminescence microscopy (EM) is presented. The 2 modalities are physically co‐registered in a common‐path configuration. The instrument is enabled by a dedicated planar lightwave circuit with a footprint of only 1.1 × 19.5 mm2 that provides akinetic axial OCT scanning at speeds up to 24 kHz. Lateral scanning is implemented through a low‐voltage Micro Electro‐Mechanical System (MEMS) mirror packaged with the axial scanner in a hermetic butterfly module. The OCT system, with a volume of only 80 × 27 × 14 mm3, achieves an isotropic resolution of ~11 μm in tissue, −93 dB sensitivity, 12 mm lateral field of view, and an axial scanning range of 2.8 mm in air. The complete battery‐powered device has a weight of 3 kg in a tablet format, enabling point‐of‐care use cases. This work shows that integration of complementary imaging modalities through miniaturization technology results in clinically valuable instruments supporting a patient‐centered diagnostic imaging workflow.


  • Relation between denaturation time measured by optical coherence reflectometry and thermal lesion depth during radiofrequency cardiac ablation: Feasibility numerical study

    by Ana González‐Suárez, David Herranz, Enrique Berjano, Jose L. Rubio‐Guivernau, Eduardo Margallo‐Balbás

    Background/Objective: Radiofrequency (RF) catheter ablation is a minimally invasive medical procedure used to thermally destroy the focus of cardiac arrhythmias. Novel optical techniques are now being integrated into RF catheters in order to detect the changes in tissue properties. Loss of birefringence due to fiber denaturation at around 70°C is related to changes in accumulated phase retardation and can be measured by polarization‐sensitive optical coherence reflectometry (PS‐OCR). Since irreversible thermal lesions are produced when the tissue reaches 50°C, our goal was to seek the mathematical relationship between both isotherms.Materials and Methods: A two‐dimensional model based on a coupled electric‐thermal problem was built and solved using the finite element method. The model consisted of cardiac tissue, blood, and a non‐irrigated electrode with a sensor embedded in its tip to maintain a specific target electrode temperature. Computer simulations were conducted by varying the tissue characteristics. Lesion depth was estimated by the 50°C isotherm, while the denaturation time (TD) was taken as the time at which the 70°C isotherm reached a depth of 0.75 mm (which corresponds to the optical depth reached by PS‐OCR technology).Results: A strong correlation (R2 > 0.83) was found between TD and lesion depth and an even stronger correlation (R2 > 0.96) was found between TD and the time required to achieve a specific lesion depth. For instance, the ablation time required to ensure a minimum lesion depth of 3 mm was 1.33 × TD + 3.93 × seconds.Conclusions: The computer results confirmed the strong relationship between denaturation time and lesion depth and suggest that measuring denaturation time by PS‐OCR could provide information on the ablation time required to reach a specific lesion depth. Lasers Surg. Med. 50:222–229, 2018.


  • Real Time Signal Processing and Data Handling with dedicated hardware in handheld OCT Device

    by P. Guerra, J.J. Valverde, A. Martin, M.J. Ledesma, J.L. Rubio-Guivernau, A. Santos

    The manuscript presents the topics on real time signal processing with dedicated hardware presented at the INFIERI Summer School 2014. The focus of this work is on real-time signal processing, filtering and massive parallel computing. In general, medical devices have stringed demands on energy consumption as well as on data processing and handling. In fact, the development of novel medical devices has led to significant advances in fields such as instrumentation, algorithm development and image processing. In this manuscript, two aspects of the design are brought into consideration: the transformation of a conventional signal processing algorithm into an equivalent version that is suitable for hardware implementation and the use of on-chip modules originally developed for mass-electronics applications, for high speed data transmission. The development of a novel state-of-the-art hand-held OCT probe is used to exemplify theses aspects. In particular, the ``design process'' behind the implementation of a multichannel quadrature coherent demodulator is disclosed.


  • Novel catheter enabling simultaneous radiofrequency ablation and optical coherence reflectometry

    by D. Herranz, Juan Lloret, Santiago Jiménez-Valero, J. L. Rubio-Guivernau, Eduardo Margallo-Balbás

    A novel radiofrequency ablation catheter has been developed with integrated custom designed optics, enabling real-time monitoring of radiofrequency ablation procedures through polarization-sensitive optical coherence reflectometry. The optics allow for proper tissue illumination through a view-port machined in the catheter tip, thus providing lesion depth control over the RF ablation treatment. The system was verified in an in-vitro model of swine myocardium. Optical performance and thermal stability was confirmed after more than 25 procedures, without any damage to the optical assembly induced by thermal stress or material degradation. The use of this catheter in RF ablation treatments may make possible to assess lesion depth during therapy, thus translating into a reduction of potential complications on the procedure.


  • Evaluation of speckle reduction with denoising filtering in optical coherence tomography for dermatology

    by Juan J. Gomez-Valverde, Juan E. Ortuno, Pedro Guerra, Boris Hermann, Behrooz Zabihian, Jose L. Rubio-Guivernau, Andres Santos, Wolfgang Drexler, Maria J. Ledesma-Carbayo

    Optical Coherence Tomography (OCT) has shown a great potential as a complementary imaging tool in the diagnosis of skin diseases. Speckle noise is the most prominent artifact present in OCT images and could limit the interpretation and detection capabilities. In this work we evaluate various denoising filters with high edge-preserving potential for the reduction of speckle noise in 256 dermatological OCT B-scans. Our results show that the Enhanced Sigma Filter and the Block Matching 3-D (BM3D) as 2D denoising filters and the Wavelet Multiframe algorithm considering adjacent B-scans achieved the best results in terms of the enhancement quality metrics used. Our results suggest that a combination of 2D filtering followed by a wavelet based compounding algorithm may significantly reduce speckle, increasing signal-to-noise and contrast-to-noise ratios, without the need of extra acquisitions of the same frame.


  • Noninvasive identification of epicardial ventricular tachycardia substrate by magnetic resonance–based signal intensity mapping

    by Ángel Arenal, Esther Pérez-David, Pablo Ávila, Javier Fernández-Portales, Verónica Crisóstomo, Claudia Báez, Javier Jiménez-Candil, José L. Rubio-Guivernau, María J. Ledesma-Carbayo, Gerard Loughlin, et al.


  • Open Access

    Do the spatial characteristics of myocardial scar tissue determine the risk of ventricular arrhythmias?

    by ÁNgel Arenal, Jesus HernÁNdez, Esther PÉRez-David, JosÉ L. Rubio-Guivernau, Maria J. Ledesma-Carbayo, Francisco FernÁNdez-AvilÉS

    Sudden cardiac death is one of the main causes of mortality in patients with structural heart disease. Although an implantable cardioverter defibrillator significantly reduces the mortality rate, many patients never receive a shock. Identification of high-risk patients would reduce the costs associated with this therapy and prevent the deleterious effect of inappropriate discharges. As scar tissue is the substrate of ventricular arrhythmias in patients with structural heart disease, scar characterization could allow stratification of the risk. The objective of this article is to review the role of scar characteristics in the pathogenesis of ventricular arrhythmias in patients with structural heart disease.


  • Open Access

    Virtual PET Scanner – From Simulation in GATE to a Final Multiring Albira PET/SPECT/CT Camera

    by M. Balcerzyk, L. Caballero, C. Correcher, A. Gonzalez, C. Vazquez, J.L. Rubio, G. Kontaxakis, M.A. Pozo, J.M. Benlloch

  • Methodology for Reconstructing Early Zebrafish Development From In Vivo Multiphoton Microscopy

    by M. A. Luengo-Oroz, J. L. Rubio-Guivernau, E. Faure, T. Savy, L. Duloquin, N. Olivier, D. Pastor, M. Ledesma-Carbayo, D. Debarre, P. Bourgine, et al.

    Investigating cell dynamics during early zebrafish embryogenesis requires specific image acquisition and analysis strategies. Multiharmonic microscopy, i.e., second- and third-harmonic generations, allows imaging cell divisions and cell membranes in unstained zebrafish embryos from 1- to 1000-cell stage. This paper presents the design and implementation of a dedicated image processing pipeline (tracking and segmentation) for the reconstruction of cell dynamics during these developmental stages. This methodology allows the reconstruction of the cell lineage tree including division timings, spatial coordinates, and cell shape until the 1000-cell stage with minute temporal accuracy and micrometer spatial resolution. Data analysis of the digital embryos provides an extensive quantitative description of early zebrafish embryogenesis.