FKFadhil Abdulrazzaq Kareem

Fadhil Abdulrazzaq Kareem

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fadhil Abdulrazzaq Kareem has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental and numerical analysis of the forced draft wet cooling tower

    by Noor Samir Lafta, Fadhil Abdulrazzaq Kareem, Maha Ghafur

    Cooling towers are essentially large boxes designed to maximize the evaporation of water. The inlet water temperature and water to air mass flow rate ratio (L/G) significantly affect the performance of the cooling tower. The number of a transfer unit (NTU), Merkel number (Me), Lewis number (Le), and efficiency of the cooling tower define the performance of the forced cooling tower. In this research paper, different inlet water temperatures ranging from 28 °C to 42 °C and (L/G) ranging from 0.5, 1, and 1.5 were used to investigate the performance of the forced cooling tower. Mathematical modeling equations were used to calculate NTU, Me, Le, and efficiency at different inlet water temperatures and (L/G). Engineering equation solver (EES) software was used to solve these mathematical modeling equations. Further, an experimental investigation was carried to find forced cooling tower performance at different inlet water temperatures and (L/G), and results were compared with the theoretical results. The results revealed that increasing the inlet water temperature, NTU, Me, Le, and efficiency increased and were directly related to each other. Further, NTU and efficiency were increased by increasing (L/G). At the same time, the Me and Le reduced with (L/G). Finally, an acceptable and better agreement has been obtained between experimental and theoretical results. Based on obtained results, it has been concluded that higher values of inlet water temperature and (L/G) provided the higher performance of the forced cooling tower.


  • Intermittent and continuous adsorption refrigeration systems techniques: A review

    by Fadhil Abdulrazzaq Kareem, Abdul Hadi N. Khalifa, Ahmed J. Hamad

    In recent decades, adsorption refrigeration systems (ARS) are becoming increasingly popular as one type of environmentally friendly refrigeration system that us In recent decades, adsorption refrigeration systems (ARS) are becoming increasingly popular as one type of environmentally friendly refrigeration system that us


  • Open Access

    Geographical siting of wind turbine in Iraq based on the exergy maps

    by Fadhil Abdulrazzaq Kareem, Noor Samir Lafta, Doaa Zaid Khalaf, Yasser Abdul Lateef

    Wind energy is a renewable energy source that is obtained by converting wind mechanical energy into electrical energy or pumping energy. Polaris P19-100 wind turbine type was selected for the study and development of wind exergy maps for Iraq. The analysis was done using Engineering Equation Solver (EES) software and Golden Grapher software. The wind data such as velocity, temperature, pressure, wet bulb temperature, and relative humidity can be obtained from Meteonorm software, only moisture content (moisture ratio) (ω) was estimated by EES software. The findings reveal that the exergy destruction in the south of Iraq is about (1442 W), which is higher than that in the north of Iraq (60 W). Also, exergy destruction was higher in the winter season than summer season. So that, the exergy efficiency in the north is (17%) greater than in the south of Iraq (3%). The wind turbine’s exergy is influenced by climatic factors that must not be overlooked since they might lead to design mistakes.


  • Numerical investigation of the heat transfer enhancement inside a square duct with rectangular vortex generators

    by Mustafa J. Al-Dulaimi, Fadhil Abdulrazzaq Kareem, Faik A. Hamad

    This paper investigates numerically the influence of detached square vortex generator (VGs) on the heat transfer and pressure drop inside a square duct. Reynolds number is fixed at 5000. The geometrical parameters in this investigation are: i) The blocking ratios are 0.1, 0.15 and 0.2), ii) Vortex generator numbers are 1, 2, and 3), iii) Attack angles are 0, 30, and 45, iv) The aspect ratios are 1, 1.5 and 2. The numerical simulation is carried out using ANSYS FLUENT 15 . The results show that the rectangular vortex generators have a positive influence on heat transfer as a result of the augmentation in turbulence level. The maximum enhancement in average heat transfer could reach 40%. The heat transfer is found to increase with the blocking ratio. The heat transfer enhanced by 17% for one VG and 28% for 3 VGs for blocking ratio = 0.2. The VGs at angle value of 45° produce the highest heat transfer enhancement. The aspect ratio is found to have an adverse effect on heat transfer rate.


  • Open Access

    Effect Of The Water Inlet Temperature And Flow Rate On The Energy And Exergy Performance of A Forced Draft Counter Wet Cooling Tower

    by Fadhil Abdulrazzaq Kareem, Doaa Zaid Khalaf, Mustafa J. Al-Dulaimi, Yasser Abdul Lateef

    The authors have requested that this preprint be removed from Research Square.

  • Open Access

    Evaluation of thermal performance for natural and forced draft wet cooling tower

    by M. J. Al-Dulaimi, F. A. Kareem, F. A. Hamad

    This paper presents an experimental and numerical investigation of the thermal performance of natural draft wet cooling tower (NDWCT). The experimental investigation is carried out under natural draft condition and forced draft condition created by an axial fan. The operational parameters considered in this study are the thickness of the fill (10 and 20 cm), inlet water temperature (40, 45, and 50 °C) and inlet water volume flow rate (5.68, 7.75, and 9.46 L/min). The experimental results showed that the thermal performance is improved when the fans are used with the NDWCT. The temperature difference between inlet and outlet and effectiveness increase by 35% and 37.2%, respectively at fill thickness of 20 cm and water volume flow rate of 11.35 L/min. The temperature distribution of the air and the relative humidity were numerically simulated for both cases of natural and forced draft by employing the commercial CFD software ANSYS Fluent 15. The experimental and numerical results were validated with results from a previous work and showed a good agreement. The experimental results showed that the effectiveness increase by 22% and 30% for NDWCT and FDWCT respectively when in case of fill thickness 20 cm.


  • Open Access

    Energy and Exergy Analysis of the Solar Radiation Incident over Iraq

    by Fadhil Abdulrazzaq Kareem, Noor Samir Lafta, Doaa Zaid Khalaf

    The solar radiation is renewable energy and great useful energy of in Iraq. This paper presents a study to compare the daily solar exergy, daily solar radiation, and daily solar that measured by Iraqi Agro-meteorological network in Baghdad. Then, a comparison between the solar energy and solar radiation in six cities in Iraq (Basra, Najaf, Baghdad, Anbar, Mosul, and Sulaymaniyah). The solar exergy estimated using the model of Nayak and Tiwari, while the solar radiation estimated using linear correlation which represented by (Angstrom correlation). The results showed that there is an agreement between daily solar radiation and daily solar which measured in Baghdad with mean error throughout the whole year from January to December (7.2%, 2.4%, 12.5%, 9.1%, 3.2%, 5.1%, 3.7%, 5.4%, 10.9%, 11.4%, 11.1%, and 3.7%), respectively. While, the daily solar exergy had very good agreement with the daily solar measured in Baghdad with mean error through the same 12-months (1.4%, 9.4%, 6.1%, 2.6%, 10.8%, 1.9%, 3.5%, 1.6%, 4.4%, 5.1%, 5%, and 2.7%), respectively. Also, higher daily solar radiation and daily solar exergy were in Basra, but the lowest was in Mosul. The daily solar exergy was (10.27, 10.09, 10, 10, 9.69, and 9.81 MJ/m2) in Basra, Najaf, Baghdad, Anbar, Mosul and Sulaimaniya, respectively. While, the percentage difference between daily solar radiation and daily solar exergy was (7.09%, 7.04, 7%, 6.99%, 6.96%, and 6.85 %) in Basra, Najaf, Anbar, Baghdad, Mosul and Sulaimaniya, respectively.


  • Open Access

    ENERGY AND EXERGY ANALYSIS OF A SOLAR PHOTOVOLTAIC PERFORMANCE IN BAGHDAD

    by Fadhil Abdulrazzaq Kareem, Doaa Zaid Khalaf, Noor Samir Lafta, Yasser Abdul Lateef


  • Investigation The Exergy Performance of a Forced Draft Wet Cooling Tower

    by Fadhil Abdulrazzaq Kareem, Mustafa Al-Dulaimi, Noor Samir Lafta

    The performance of a forced draft wet cooling tower was investigated experimentally and the calculation was performed by applying second law of thermodynamics (exergy analysis). The mathematical model was developed by using engineering equation solver (EES) software. The results show that the chemical exergy of air increases from the bottom to the top of the cooling tower, the thermal exergy of air decreases from bottom to the top of the cooling, the exergy of water decreases from top to the bottom of the cooling tower. The exergy destruction decreases from bottom to the top of the cooling tower, and the exergy efficiency decreases from top to the bottom of the cooling. The exergy destruction tends to increase as the inlet wet bulb temperature increases while the exergy efficiency decreases. As water-air flow rate ratio increases the exergy destruction increases while the exergy efficiency decreases. The results show that there is an inverse proportional be-tween exergy destruction and exergy efficiency.