Mustafa J. Al-Dulaimi
Research Subjects
Mustafa J. Al-Dulaimi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Faik Hamad
School of Computing, Engineering & Digital Technologies Teesside University Middlesbrough Tees Valley UK
4 shared publications - Fadhil Abdulrazzaq Kareem
Institute of Technology Baghdad, Middle Technical University, Baghdad, Iraq
3 shared publications F. A. Hamad
Engineering School of Science & Engineering, Teesside University, Middlesbrough, TS1 3BA, UK
2 shared publicationsKarima E. Amori
Dept. of Mechanical Eng., University of Baghdad, Baghdad, Iraq
2 shared publicationsA. A. Abdul Rasool
Mech. Eng. Dept, college of Engineering, Al-Mustansiriya University, Baghdad, Iraq
1 shared publicationAdnan A. Abdul Rasool
Mechanical Engineering Department, College of Engineering; Al-Mustansiriya University; Baghdad Iraq
1 shared publication
Latest Publications
- 4 May 2026
- Published by Wiley in Heat Transfer
- Vol. 55 (5) , 3364-3385
Optical and Thermal Performance Enhancement of a Parabolic Trough Solar Collector With Helical Turbulators and Modified Receiver Geometries
Enhancing the thermal efficiency of parabolic trough solar collectors (PTCs) is vital for optimizing concentrated solar power systems and industrial solar thermal applications. Conventional receiver tubes often suffer from limited internal heat transfer and uneven solar flux distribution, reducing energy conversion efficiency. This study presents a comprehensive numerical investigation of PTC receivers with modified tube geometries ‐circular, elliptical, and hexagonal‐integrated with internal helical turbulators. Optical performance was evaluated using Monte Carlo Ray Tracing (MCRT) to determine solar flux distribution and identify optimal receiver eccentricities, while thermal–hydraulic behavior was assessed via computational fluid dynamics (CFD) simulations over Reynolds numbers from 3000 to 11,000. Optimal eccentricities were determined as −12, −8, and −12 mm for circular, elliptical, and hexagonal tubes, respectively. The elliptical tube achieved the highest optical interception, with an average intercept factor of 80.13%. The introduction of helical turbulators significantly enhanced heat transfer, increasing Nusselt numbers by 31%, 45%, and 46% for circular, elliptical, and hexagonal tubes, respectively. Corresponding friction factor ratios ranged from 1.6 to 2.0, highlighting the trade‐off between heat transfer improvement and flow resistance. Overall, the elliptical receiver with a small‐pitch helical turbulator delivered the best combined thermo‐optical performance.
- 4 May 2026
- Published by Wiley in Heat Transfer
- Vol. 55 (5) , 3364-3385
Optical and Thermal Performance Enhancement of a Parabolic Trough Solar Collector With Helical Turbulators and Modified Receiver Geometries
Enhancing the thermal efficiency of parabolic trough solar collectors (PTCs) is vital for optimizing concentrated solar power systems and industrial solar thermal applications. Conventional receiver tubes often suffer from limited internal heat transfer and uneven solar flux distribution, reducing energy conversion efficiency. This study presents a comprehensive numerical investigation of PTC receivers with modified tube geometries ‐circular, elliptical, and hexagonal‐integrated with internal helical turbulators. Optical performance was evaluated using Monte Carlo Ray Tracing (MCRT) to determine solar flux distribution and identify optimal receiver eccentricities, while thermal–hydraulic behavior was assessed via computational fluid dynamics (CFD) simulations over Reynolds numbers from 3000 to 11,000. Optimal eccentricities were determined as −12, −8, and −12 mm for circular, elliptical, and hexagonal tubes, respectively. The elliptical tube achieved the highest optical interception, with an average intercept factor of 80.13%. The introduction of helical turbulators significantly enhanced heat transfer, increasing Nusselt numbers by 31%, 45%, and 46% for circular, elliptical, and hexagonal tubes, respectively. Corresponding friction factor ratios ranged from 1.6 to 2.0, highlighting the trade‐off between heat transfer improvement and flow resistance. Overall, the elliptical receiver with a small‐pitch helical turbulator delivered the best combined thermo‐optical performance.
- Open Access
- 15 September 2023
- Published by Mesopotamian Academic Press - DIGITAL COMMONS JOURNALS in Babylonian Journal of Mechanical Engineering
- Vol. 2023, 71-77
Experimental Investigation of The Turbulence Generators on Heat Transfer Inside Heated Duct
This work investigates the heat transfer inside a square duct experimentally in the presence of detached rectangular and triangular turbulence generators. The effect of the ratio of turbulence generators to the duct height (blocking ratio) is investigated for the values of 0.1, 0.15, and 0.2 for Reynolds number 15413. The results showed that turbulence generators have a positive effect on heat transfer. It was found that using rectangular and triangular turbulence generators augments the heat transfer by (3-9)% and (5-15)%, respectively. Also, it was revealed that increasing the blocking ratio of turbulence generators from 0.1 to 0.2 enhances the heat transfer by 6% and 10% for rectangular and triangular shapes, respectively.
- 15 September 2023
- Published by Mesopotamian Academic Press - DIGITAL COMMONS JOURNALS in Babylonian Journal of Mechanical Engineering
- Vol. 2023, 71-77
Open AccessExperimental Investigation of The Turbulence Generators on Heat Transfer Inside Heated Duct
This work investigates the heat transfer inside a square duct experimentally in the presence of detached rectangular and triangular turbulence generators. The effect of the ratio of turbulence generators to the duct height (blocking ratio) is investigated for the values of 0.1, 0.15, and 0.2 for Reynolds number 15413. The results showed that turbulence generators have a positive effect on heat transfer. It was found that using rectangular and triangular turbulence generators augments the heat transfer by (3-9)% and (5-15)%, respectively. Also, it was revealed that increasing the blocking ratio of turbulence generators from 0.1 to 0.2 enhances the heat transfer by 6% and 10% for rectangular and triangular shapes, respectively.
- Open Access
- 30 March 2023
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in International Journal of Automotive and Mechanical Engineering
- Vol. 20 (1) , 10258-10273
Energy and Exergy Investigation of a Solar Air Heater for Different Absorber Plate Configurations
In this paper, the effect of using different configurations of absorber plate, including one line finned flat absorber and two lines finned absorber plate, on the thermal performance of a flat plate – double passing solar air heater was investigated experimentally. L- shape fins are soldered on the absorber plate to roughen the absorber plate and generate vortices to enhance the heat transfer between the working fluid (air) and absorber plate to improve the thermal efficiency. The outdoor experimental test was carried out during February and May under the weather conditions of Baghdad city (Longitude 33.3 N and Latitude 44.44 E). The results show that the air temperature is 48 ℃, 47.5 ℃, and 58.5 ℃ at an air velocity of 1.7 m/s for a single line of fins which increased to 52 ℃, 57.5 ℃, and 66 ℃ at air velocity of 0.9 m/s for two lines of fins. The efficiency is increased by 28% for one line of fins and 66% for two lines of fins at an air velocity of 0.9 m/s while increased by 27% for one line of fins and 51% for two lines of fins at an air velocity of 1.7 m/s. The average exergy destruction rate increases by 37.6%, 60.6%, and 68.66% for the absorber plate, working fluid, and glass cover, respectively, for velocity increase from 0.9 m/s to 1.9 m/s. The exergy efficiency increased by 24.1% when the velocity increased from 0.9 m/s to 1.9 m/s.
- 30 March 2023
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in International Journal of Automotive and Mechanical Engineering
- Vol. 20 (1) , 10258-10273
Open AccessEnergy and Exergy Investigation of a Solar Air Heater for Different Absorber Plate Configurations
In this paper, the effect of using different configurations of absorber plate, including one line finned flat absorber and two lines finned absorber plate, on the thermal performance of a flat plate – double passing solar air heater was investigated experimentally. L- shape fins are soldered on the absorber plate to roughen the absorber plate and generate vortices to enhance the heat transfer between the working fluid (air) and absorber plate to improve the thermal efficiency. The outdoor experimental test was carried out during February and May under the weather conditions of Baghdad city (Longitude 33.3 N and Latitude 44.44 E). The results show that the air temperature is 48 ℃, 47.5 ℃, and 58.5 ℃ at an air velocity of 1.7 m/s for a single line of fins which increased to 52 ℃, 57.5 ℃, and 66 ℃ at air velocity of 0.9 m/s for two lines of fins. The efficiency is increased by 28% for one line of fins and 66% for two lines of fins at an air velocity of 0.9 m/s while increased by 27% for one line of fins and 51% for two lines of fins at an air velocity of 1.7 m/s. The average exergy destruction rate increases by 37.6%, 60.6%, and 68.66% for the absorber plate, working fluid, and glass cover, respectively, for velocity increase from 0.9 m/s to 1.9 m/s. The exergy efficiency increased by 24.1% when the velocity increased from 0.9 m/s to 1.9 m/s.
- 27 April 2022
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 47 (12) , 16117-16133
Optical and Thermal Performance of a Parabolic Trough Collector for Different Receiver Geometries
- 27 April 2022
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 47 (12) , 16117-16133
Optical and Thermal Performance of a Parabolic Trough Collector for Different Receiver Geometries
- 1 February 2022
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 8 (1) , 1-13
Numerical investigation of the heat transfer enhancement inside a square duct with rectangular vortex generators
This paper investigates numerically the influence of detached square vortex generator (VGs) on the heat transfer and pressure drop inside a square duct. Reynolds number is fixed at 5000. The geometrical parameters in this investigation are: i) The blocking ratios are 0.1, 0.15 and 0.2), ii) Vortex generator numbers are 1, 2, and 3), iii) Attack angles are 0, 30, and 45, iv) The aspect ratios are 1, 1.5 and 2. The numerical simulation is carried out using ANSYS FLUENT 15 . The results show that the rectangular vortex generators have a positive influence on heat transfer as a result of the augmentation in turbulence level. The maximum enhancement in average heat transfer could reach 40%. The heat transfer is found to increase with the blocking ratio. The heat transfer enhanced by 17% for one VG and 28% for 3 VGs for blocking ratio = 0.2. The VGs at angle value of 45° produce the highest heat transfer enhancement. The aspect ratio is found to have an adverse effect on heat transfer rate.
- 1 February 2022
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 8 (1) , 1-13
Numerical investigation of the heat transfer enhancement inside a square duct with rectangular vortex generators
This paper investigates numerically the influence of detached square vortex generator (VGs) on the heat transfer and pressure drop inside a square duct. Reynolds number is fixed at 5000. The geometrical parameters in this investigation are: i) The blocking ratios are 0.1, 0.15 and 0.2), ii) Vortex generator numbers are 1, 2, and 3), iii) Attack angles are 0, 30, and 45, iv) The aspect ratios are 1, 1.5 and 2. The numerical simulation is carried out using ANSYS FLUENT 15 . The results show that the rectangular vortex generators have a positive influence on heat transfer as a result of the augmentation in turbulence level. The maximum enhancement in average heat transfer could reach 40%. The heat transfer is found to increase with the blocking ratio. The heat transfer enhanced by 17% for one VG and 28% for 3 VGs for blocking ratio = 0.2. The VGs at angle value of 45° produce the highest heat transfer enhancement. The aspect ratio is found to have an adverse effect on heat transfer rate.
- 18 January 2022
- Published by Wiley in Heat Transfer
- Vol. 51 (3) , 2437-2457
Effect of receiver geometry on the optical and thermal performance of a parabolic trough collector
In this study, the optical and thermal performance of a Parabolic Trough Collector PTC system is investigated theoretically. A series of numerical simulations and theoretical analysis has been conducted to investigate the effect of the receiver geometry and location relative to the focal line on its optical performance. The examined receiver geometries are circular, square, triangular, elliptical and a new design of circular‐ square named as channel receiver. The thermal performance of PTC is studied for different flow rates from (0.27 to 0.6 lpm) theoretically. Results showed that the best optical design is the channel receiver with an optical efficiency of 84% while the worst is the elliptical receiver with an optical efficiency of 70%. Thermally the best design is the elliptical receiver with a thermal efficiency of 85% while the worst is the circular receiver with a thermal efficiency of 82%.
- 18 January 2022
- Published by Wiley in Heat Transfer
- Vol. 51 (3) , 2437-2457
Effect of receiver geometry on the optical and thermal performance of a parabolic trough collector
In this study, the optical and thermal performance of a Parabolic Trough Collector PTC system is investigated theoretically. A series of numerical simulations and theoretical analysis has been conducted to investigate the effect of the receiver geometry and location relative to the focal line on its optical performance. The examined receiver geometries are circular, square, triangular, elliptical and a new design of circular‐ square named as channel receiver. The thermal performance of PTC is studied for different flow rates from (0.27 to 0.6 lpm) theoretically. Results showed that the best optical design is the channel receiver with an optical efficiency of 84% while the worst is the elliptical receiver with an optical efficiency of 70%. Thermally the best design is the elliptical receiver with a thermal efficiency of 85% while the worst is the circular receiver with a thermal efficiency of 82%.
- 26 August 2020
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 57 (1) , 111-123
Experimental and numerical study of pressure drop in pipes packed with large particles
- 26 August 2020
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 57 (1) , 111-123
Experimental and numerical study of pressure drop in pipes packed with large particles
- Open Access
- 30 December 2019
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in Journal of Mechanical Engineering and Sciences
- Vol. 13 (4) , 6007-6021
Evaluation of thermal performance for natural and forced draft wet cooling tower
This paper presents an experimental and numerical investigation of the thermal performance of natural draft wet cooling tower (NDWCT). The experimental investigation is carried out under natural draft condition and forced draft condition created by an axial fan. The operational parameters considered in this study are the thickness of the fill (10 and 20 cm), inlet water temperature (40, 45, and 50 °C) and inlet water volume flow rate (5.68, 7.75, and 9.46 L/min). The experimental results showed that the thermal performance is improved when the fans are used with the NDWCT. The temperature difference between inlet and outlet and effectiveness increase by 35% and 37.2%, respectively at fill thickness of 20 cm and water volume flow rate of 11.35 L/min. The temperature distribution of the air and the relative humidity were numerically simulated for both cases of natural and forced draft by employing the commercial CFD software ANSYS Fluent 15. The experimental and numerical results were validated with results from a previous work and showed a good agreement. The experimental results showed that the effectiveness increase by 22% and 30% for NDWCT and FDWCT respectively when in case of fill thickness 20 cm.
- 30 December 2019
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in Journal of Mechanical Engineering and Sciences
- Vol. 13 (4) , 6007-6021
Open AccessEvaluation of thermal performance for natural and forced draft wet cooling tower
This paper presents an experimental and numerical investigation of the thermal performance of natural draft wet cooling tower (NDWCT). The experimental investigation is carried out under natural draft condition and forced draft condition created by an axial fan. The operational parameters considered in this study are the thickness of the fill (10 and 20 cm), inlet water temperature (40, 45, and 50 °C) and inlet water volume flow rate (5.68, 7.75, and 9.46 L/min). The experimental results showed that the thermal performance is improved when the fans are used with the NDWCT. The temperature difference between inlet and outlet and effectiveness increase by 35% and 37.2%, respectively at fill thickness of 20 cm and water volume flow rate of 11.35 L/min. The temperature distribution of the air and the relative humidity were numerically simulated for both cases of natural and forced draft by employing the commercial CFD software ANSYS Fluent 15. The experimental and numerical results were validated with results from a previous work and showed a good agreement. The experimental results showed that the effectiveness increase by 22% and 30% for NDWCT and FDWCT respectively when in case of fill thickness 20 cm.
- Open Access
- 27 September 2019
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in Journal of Mechanical Engineering and Sciences
- Vol. 13 (3) , 5542-5561
Effect of sand particles on flow structure of free jet from a nozzle
The Characteristics of single and two- phase flow from a circular turbulent free jet from a nozzle of 10 mm diameter were investigated experimentally and numerically. The measurements were conducted for ReJ = 10007 - 31561. The velocity was measured at location from the nozzle y/D (0-8) in axial and radial directions. The two phase measurement were done by using natural construction sand as a solid phase of sizes (220,350,550) µm and loading ratios (mass flow ratio of sand to mass flow rate of air) in the range (0.18-1.38). Two phase air velocity of jet showed that the introducing of natural sand particles gives lower jet velocity attributed to momentum transfer to particles. The smaller particle size leads to lower values of velocity. The velocity found to be decreased with loading ratio increase. The numerical simulation was performed for single and two phase jet flow. RNG K-ε turbulence model was used to simulate the flow of fluid and the discrete phase model to simulate the particles flow. The results form numerical simulation showed a good agreement with experimental results.
- 27 September 2019
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in Journal of Mechanical Engineering and Sciences
- Vol. 13 (3) , 5542-5561
Open AccessEffect of sand particles on flow structure of free jet from a nozzle
The Characteristics of single and two- phase flow from a circular turbulent free jet from a nozzle of 10 mm diameter were investigated experimentally and numerically. The measurements were conducted for ReJ = 10007 - 31561. The velocity was measured at location from the nozzle y/D (0-8) in axial and radial directions. The two phase measurement were done by using natural construction sand as a solid phase of sizes (220,350,550) µm and loading ratios (mass flow ratio of sand to mass flow rate of air) in the range (0.18-1.38). Two phase air velocity of jet showed that the introducing of natural sand particles gives lower jet velocity attributed to momentum transfer to particles. The smaller particle size leads to lower values of velocity. The velocity found to be decreased with loading ratio increase. The numerical simulation was performed for single and two phase jet flow. RNG K-ε turbulence model was used to simulate the flow of fluid and the discrete phase model to simulate the particles flow. The results form numerical simulation showed a good agreement with experimental results.
- 5 September 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (4) , 2575-2580
Investigation The Exergy Performance of a Forced Draft Wet Cooling Tower
The performance of a forced draft wet cooling tower was investigated experimentally and the calculation was performed by applying second law of thermodynamics (exergy analysis). The mathematical model was developed by using engineering equation solver (EES) software. The results show that the chemical exergy of air increases from the bottom to the top of the cooling tower, the thermal exergy of air decreases from bottom to the top of the cooling, the exergy of water decreases from top to the bottom of the cooling tower. The exergy destruction decreases from bottom to the top of the cooling tower, and the exergy efficiency decreases from top to the bottom of the cooling. The exergy destruction tends to increase as the inlet wet bulb temperature increases while the exergy efficiency decreases. As water-air flow rate ratio increases the exergy destruction increases while the exergy efficiency decreases. The results show that there is an inverse proportional be-tween exergy destruction and exergy efficiency.
- 5 September 2018
- Published by Science Publishing Corporation in International Journal of Engineering & Technology
- Vol. 7 (4) , 2575-2580
Investigation The Exergy Performance of a Forced Draft Wet Cooling Tower
The performance of a forced draft wet cooling tower was investigated experimentally and the calculation was performed by applying second law of thermodynamics (exergy analysis). The mathematical model was developed by using engineering equation solver (EES) software. The results show that the chemical exergy of air increases from the bottom to the top of the cooling tower, the thermal exergy of air decreases from bottom to the top of the cooling, the exergy of water decreases from top to the bottom of the cooling tower. The exergy destruction decreases from bottom to the top of the cooling tower, and the exergy efficiency decreases from top to the bottom of the cooling. The exergy destruction tends to increase as the inlet wet bulb temperature increases while the exergy efficiency decreases. As water-air flow rate ratio increases the exergy destruction increases while the exergy efficiency decreases. The results show that there is an inverse proportional be-tween exergy destruction and exergy efficiency.