RCRobin A. Christian

Robin A. Christian

*This is an algorithmically generated author record based on publicly available information.

Robin A. Christian has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Monitoring of Personal Exposure Due to Particulate Matter

    by Madhumita Chakraborty, Smaranika Panda, Robin A. Christian

  • Open Access

    Unveiling Occupational Exposure: The Impact of Particulate Matter on Traffic Policemen in Industrial Zones

    by Madhumita Chakraborty, Smaranika Panda, Robin Christian

    Air pollution, primarily driven by particulate matter (PM), is a major global health challenge, contributing to respiratory, cardiovascular, and neurological diseases, as well as premature mortality. Traditional ambient monitoring often fails to capture the spatial variability and individualized exposure patterns critical to understanding PM's health impacts. Personal exposure monitoring has emerged as a transformative tool, as it include diverse microenvironments. Studies reveal that personal exposure data reduce misclassification, improve exposure-health relationship modeling, and provide insights into source-specific toxicity, thereby enabling more targeted regulatory and public health interventions.Traffic policemen, due to their constant presence in traffic-dense environments, are uniquely vulnerable to PM exposure. Despite advancements in wearable and low-cost monitoring technologies, limited research addresses occupational exposure in this high-risk group. This study aims to bridge this gap by implementing cutting-edge monitoring technologies to quantify and characterize the exposure of traffic policemen to PM. The personal exposure (PM5 & PM2.5) samples for traffic policemen standing on roads of an industrial area were collected for 15 days along with ambient air quality data for PM (PM100, PM10, PM2.5, and PM1) and gaseous pollutants (NO2, CO, and O3). The personal exposure samples were collected using an SKC personal monitor and Envirotech handy sampler, whereas the ambient air quality data was collected using a sensor-based instrument (Make: Oizom Pvt. Ltd). The collected samples were analyzed for PM concentration using gravimetric methods.PM deposits in human lungs as they enter in to the respiratory system by inhalation. The deposition of PM in different regions of the lungs was also estimated by using Multiple-Path Particle Dosimetry 3.02 model.The findings from the study indicate that the average personal exposure concentrations for PM2.5 and PM5 were 102.96 ± 38.20 µg/m³ and 138.18 ± 30.41 µg/m³, respectively. The personal exposure level for PM2.5 was notably six times higher than the 24-hour average air quality standard set by the World Health Organization (WHO).Analysis of ambient air quality data revealed that PM2.5 levels varied from 69.79 µg/m³ to 127.23 µg/m³, with an average concentration of 99.96 µg/m³, which, while still significantly above the WHO guidelines, was lower than the personal exposure levels. This discrepancy highlights that the population under study experienced elevated exposure to PM concentrations compared to ambient air conditions, suggesting that individual exposure conditions are influenced by specific situational and occupational factors. The identified primary sources of particulate matter include industrial fuel combustion, traffic emissions, and resuspension of road dust. Additionally, the proximity of traffic policemen to vehicle exhausts due to the low height of their standing platforms was identified as a contributing factor to the elevated personal exposure levels. This occupational setup positions individuals directly in the pathway of high concentrations of vehicular emissions, exacerbating their risk.The study found the highest particulate matter deposition in the head region of the respiratory tract, highlighting health risks from prolonged exposure to high PM levels. These findings emphasize the need for mitigation measures, such as enhanced occupational safeguards and stricter emission controls, to protect vulnerable populations

  • Application of effective orifice jet length for treating SST effluent of STP by hydrodynamic cavitation

    by Neha S. Baghele, Anjali K. Khambete, Robin A. Christian

    Advanced oxidation process in general and hydrodynamic cavitation, in particular, has emerged as a promising technology for the treatment of wastewater in the last few years as the process is energy-efficient and cost-effective. In this process, cavities are generated due to local pressure drops caused by constrictions. This work aimed to investigate the potential of hydrodynamic cavitation as a tertiary treatment to the secondary sedimentation tank effluent of a sewage treatment plant, with two laboratory-scale experimental setups having an orifice plate of a 1 mm diameter hole. The process dependency was estimated by optimizing inlet pressure (0.8 bar for setup I and 5 bar for setup II). Moreover, effective orifice jet length was varied to investigate the impact of fluid buoyancy force on expansion and collapse of a cavity on the chemical oxygen demand removal and disinfection. At L2 length (two-thirds of the original length), both setups can degrade the organic and inorganic pollutants to the maximum extent. With the optimum condition in setup II, maximum COD, TSS, and fecal coliform degradation were 80.47%, 62.83%, and 52.27%, respectively, compared to setup I. GRAPHICAL ABSTRACT


  • Air Quality Assessment Using Fuzzy Inference Systems

    by Seema A. Nihalani, Nandini Moondra, A. K. Khambete, R. A. Christian, N. D. Jariwala


  • Regeneration and reuse of magnesium oxide (MgO) nanocrystallites

    by Mehali Mehta, Mausumi Mukhopadhyay, Robin Christian

    The study focuses on regeneration and reuse of in-house synthesized MgO nanocrystallites used as an adsorbent for the removal of Acid Orange 7 dye from wastewater. The dye-adsorbed MgO were regenerated by two major steps: drying and combustion. The used MgO were dried at room temperature of 35°C ± 5°C, at an optimized time of 8–10 h time and the dried MgO were combusted at an optimized temperature of 500°C in muffle furnace for 25 min. The regeneration and reuse of MgO could be effectively carried out for five adsorption-combustion cycles. In every cycle of regeneration, 8–10% by weight of MgO was lost. The X-ray diffraction analysis showed the phase purity and the calculated crystallite size of synthesized, first, second, third, fourth and fifth regenerated MgO were noted as 21.67, 21.67, 21.67, 24.74, 24.74 and 24.74 nm, respectively. The scanning electron microscopy analysis showed that agglomeration of regenerated MgO particles increased with the increase in number of adsorption-combustion cycles.


  • Predicting Biogasification Potential of Urban Wastewater Using Multiparameter Aggregated Index of Influent

    by G. S. Anaokar, A. K. Khambete, R. A. Christian

    Municipal wastewater treatment plants have sufficient organic loading and can be utilized as reliable biogas generator. Prediction of biogasification potential is essential to maintain regularity in biogas supply and maximum utilization for energy recovery. Many attempts have been carried out to predict biogas using computational and logical models. Although due to uncertain characteristics of wastewater throughout the year, mathematical formulation of biogas found difficult. This research article has a novel approach to predict biogas using multi‐parameter aggregated index (MPAI), which has overcome the limitation of uneven characteristics. Indices for raw wastewater (MPAIinf) and digester feedstock (MPAIdig) were calculated. The correlation of biogas generation with R‐square value of 0.92 with MPAIinf and that of 0.87 for MPAIdig was found. A linear equation was established using the most significant parameter; BOD and these indices. Biogas prediction was found easy in all seasons with a precision of 93% when tested on site. © 2019 American Institute of Chemical Engineers Environ Prog, 38:e13119, 2019


  • Open Access

    Evaluation of a Performance Index for Municipal Wastewater Treatment Plants using MCDM – TOPSIS

    by Guruprasad Anaokar, Anjali Khambete, Robin Christian

    Deciding which are the best performing wastewater treatment plants can be complicated, as their operations comprise different parameters which are either dependent or non-dependent on each other, and are important when deciding the type of treatment. The relative importance of these parameters in terms of weight indicates the priority assigned by decision-makers to the criteria when ranking the alternatives. These weights are calculated by statistical relativity and Saaty’s nine point scale. The sensitivity of both of these approaches is analyzed. The performance of six municipal wastewater treatment plants is evaluated using the Multi-criteria Decision Making (MCDM) Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS). Efficiency is monitored on the basis of nine wastewater characteristics and compared with the limits established by the Central Pollution Control Board of India. The analysis uses both qualitative and quantitative approaches, which result in differential rankings; accordingly, plants with maximum organic loading removal efficiency were found to be most efficient when weights were applied as per Saaty’s scale. The study proposes a field base approach with regard to the suitability of the weight allocation method for respective utilization of the fuzzy approach in environmental monitoring systems.