JCJerome Chaptinel

Jerome Chaptinel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jerome Chaptinel has a total of 57 co-authors. Here are the top co-authors by number of shared publications:

  • Simone Coppo

    Department of Radiology, University Hospital (CHUV)/University of Lausanne (UNIL), Lausanne, VD, Switzerland

    10 shared publications
  • Davide Piccini

    Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV) and University of Lausanne (UNIL), Lausanne, Switzerland

    9 shared publications
  • Matthias Stuber

    Department of Radiology, University Hospital (CHUV)/University of Lausanne (UNIL), Lausanne, VD, Switzerland

    9 shared publications
  • Gabriella Vincenti

    Division of Cardiology and Cardiac MR Center, University Hospital Lausanne, Lausanne, Switzerland

    7 shared publications
  • Matthias Stuber

    IHU LIRYC, Heart Rhythm Disease Institute, Hôpital Xavier Arnozan, Université de Bordeaux—INSERM U1045 , Avenue du Haut Lévêque, Pessac 33604

    6 shared publications
  • Tobias Rutz

    Division of Cardiology and Cardiac MR Center, University Hospital Lausanne, Lausanne, Switzerland

    6 shared publications

Latest Publications

  • Accelerated and high‐resolution cardiac T2 mapping through peripheral k‐space sharing

    by Emeline Darçot, Jérôme Yerly, Roberto Colotti, Pier Giorgio Masci, Jerome Chaptinel, Helene Feliciano, Veronica Bianchi, Ruud B. van Heeswijk

    Purpose: To develop high‐spatial‐resolution cardiac T2 mapping that allows for a reduced acquisition time while maintaining its precision. We implemented and optimized a new golden‐angle radial T2 mapping technique named SKRATCH (Shared k‐space Radial T2 Characterization of the Heart) that shares k‐space peripheries of T2‐weighted images while preserving their contrasts.Methods: Six SKRATCH variants (gradient‐recalled echo and balanced SSFP, free‐breathing and breath‐held, with and without a saturation preparation) were implemented, and their precision was compared with a navigator‐gated reference technique in phantoms and 22 healthy volunteers at 3 T. The optimal breath‐held SKRATCH technique was applied in a small cohort of patients with subacute myocardial infarction.Results: The faster free‐breathing SKRATCH technique reduced the acquisition time by 52.4%, while maintaining the precision and spatial resolution of the reference technique. Similarly, the most precise and robust breath‐held SKRATCH technique demonstrated homogenous T2 values that did not significantly differ from the navigator‐gated reference (T2 = 39.9 ± 3.4 ms versus 39.5 ± 3.4 ms, P > .20, respectively). All infarct patients demonstrated a large T2 elevation in the ischemic regions of the myocardium.Conclusion: The optimized SKRATCH technique enabled the accelerated acquisition of high‐spatial‐resolution T2 maps, was validated in healthy adult volunteers, and was successfully applied to a small initial group of patients.


  • Open Access

    Fetal cardiac cine magnetic resonance imaging in utero

    by Jerome Chaptinel, Jerome Yerly, Yvan Mivelaz, Milan Prsa, Leonor Alamo, Yvan Vial, Gregoire Berchier, Chantal Rohner, François Gudinchet, Matthias Stuber

    Fast magnetic resonance imaging (MRI) led to the emergence of ‘cine MRI’ techniques, which enable the visualization of the beating heart and the assessment of cardiac morphology and dynamics. However, established cine MRI methods are not suitable for fetal heart imaging in utero, where anatomical structures are considerably smaller and recording an electrocardiogram signal for synchronizing MRI data acquisition is difficult. Here we present a framework to overcome these challenges. We use methods for image acquisition and reconstruction that robustly produce images with sufficient spatial and temporal resolution to detect the heart contractions of the fetus, enabling a retrospective gating of the images and thus the generation of images of the beating heart. To underline the potential of our approach, we acquired in utero images in six pregnant patients and compared these with their echocardiograms. We found good agreement in terms of diameter and area measurements, and low inter- and intra- observer variability. These results establish MRI as a reliable modality for fetal cardiac imaging, with a substantial potential for prenatal evaluation of congenital heart defects.


  • A double echo ultra short echo time (UTE) acquisition for respiratory motion‐suppressed high resolution imaging of the lung

    by Jean Delacoste, Jerome Chaptinel, Catherine Beigelman‐Aubry, Davide Piccini, Alain Sauty, Matthias Stuber

    Purpose: Magnetic resonance imaging is a promising alternative to computed tomography for lung imaging. However, organ motion and poor signal‐to‐noise ratio, arising from short , impair image quality. To alleviate these issues, a new retrospective gating method was implemented and tested with an ultra‐short echo time sequence.Methods: A 3D double‐echo ultra‐short echo time sequence was used to acquire data during free breathing in ten healthy adult subjects. A self‐gating method was used to reconstruct respiratory motion suppressed expiratory and inspiratory images. These images were objectively compared to uncorrected data sets using quantitative end‐points (pulmonary vessel sharpness, lung–liver interface definition, signal‐to‐noise ratio). The method was preliminarily tested in two cystic fibrosis patients who underwent computed tomography.Results: Vessel sharpness in expiratory ultra‐short echo time data sets with second echo motion detection was significantly higher (13% relative increase) than in uncorrected images while the opposite was observed in inspiratory images. The method was successfully applied in patients and some findings (e.g., hypointense areas) were similar to those from computed tomography.Conclusion: Free breathing ultra‐short echo time was successfully implemented, allowing flexible image reconstruction of two different respiratory states. Objective improvements in image quality were obtained with the new method and initial feasibility in a clinical setting was demonstrated. Magn Reson Med 79:2297–2305, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


  • Improved respiratory self‐navigation for 3D radial acquisitions through the use of a pencil‐beam 2D‐T2‐prep for free‐breathing, whole‐heart coronary MRA

    by Andrew J. Coristine, Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud B. van Heeswijk, Davide Piccini, Matthias Stuber

    Purpose: In respiratory self‐navigation (SN), signal from static structures, such as the chest wall, may complicate motion detection or introduce post‐correction artefacts. Suppressing signal from superfluous tissues may therefore improve image quality. We thus test the hypothesis that SN whole‐heart coronary magnetic resonance angiography (MRA) will benefit from an outer‐volume suppressing 2D‐T2‐Prep and present both phantom and in vivo results.Methods: A 2D‐T2‐Prep and a conventional T2‐Prep were used prior to a free‐breathing 3D‐radial SN sequence. Both techniques were compared by imaging a home‐built moving cardiac phantom and by performing coronary MRA in nine healthy volunteers. Reconstructions were performed using both a reference‐based and a reference‐independent approach to motion tracking, along with several coil combinations. Signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) were compared, along with vessel sharpness (VS).Results: In phantoms, using the 2D‐T2‐Prep increased SNR by 16% to 53% and mean VS by 8%; improved motion tracking precision was also achieved. In volunteers, SNR increased by an average of 29% to 33% in the blood pool and by 15% to 25% in the myocardium, depending on the choice of reconstruction coils and algorithm, and VS increased by 34%.Conclusion: A 2D‐T2‐Prep significantly improves image quality in both phantoms and volunteers when performing SN coronary MRA. Magn Reson Med 79:1293–1303, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


  • A phantom study to determine the theoretical accuracy and precision of radial MRI to measure cross‐sectional area differences for the application of coronary endothelial function assessment

    by Jérôme Yerly, Danilo Gubian, Jean‐Francois Knebel, Ali Schenk, Jerome Chaptinel, Giulia Ginami, Matthias Stuber

    MRI has been used to noninvasively assess coronary endothelial function by measuring the vasoreactivity in response to handgrip exercise. However, the spatial resolution of MRI is limited relative to the expected vasodilation response of healthy coronary arteries (10%–20%), and the sensitivity of MRI to detect such small cross-sectional area differences has yet to be quantitatively examined. Holes of different diameters were drilled in a phantom to simulate a range of physiological responses of coronary arteries to stress. Radial cine MR images with different spatial resolutions were acquired under moving conditions, and different noise levels were simulated. Cross-sectional areas were automatically measured and statistically analyzed to quantify the smallest detectable area difference. Statistical analyses suggest that radial MRI is capable of distinguishing area differences of 0.2 to 0.3 mm2 for high signal-to-noise ratio images, which correspond to a percentage coronary area difference of 3% to 4% for a 3-mm baseline diameter. Furthermore, the smallest detectable area difference was largely independent of the pixel size for the sequence and range of diameters investigated in this study. Radial MRI is capable of reliably detecting small differences in cross-sectional areas that are well within the expected physiological range of stress-induced area changes in of healthy coronary arteries. Magn Reson Med 79:108–120, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


  • Respiratory optimized data selection for more resilient self-navigated whole-heart coronary MR angiography

    by Jerome Chaptinel, Davide Piccini, Gabriele Bonanno, Simone Coppo, Pierre Monney, Matthias Stuber, Juerg Schwitter

    Our objective was to test a data-exclusion strategy for respiratory motion suppression by retrospectively eliminating data acquired at extreme respiratory positions for improved coronary vessel sharpness (VS) of 1-D self-navigated 3-D radial whole-heart coronary angiography acquisitions. 3-D radial self-navigated acquisitions were performed on a 1.5T scanner in volunteers during free-breathing (n = 8), in coached volunteers (n = 13) who were asked to breathe in a controlled manner to mimic cardiovascular patients presenting with Cheyne-Stokes breathing, and in free-breathing patients (n = 20). Data collected during large respiratory excursions were gradually excluded retrospectively from the reconstruction yielding 14 data sets per subject on average. The impact on VS, blood and myocardium signal-to-noise and contrast-to-noise was measured. From these results, two retrospective gating strategies were defined for the k-line elimination procedure and tested in all groups. Maximum right coronary artery VS improvement was +7.4 and +2.7% in coached volunteers and patients (P < 0.0001 for both), respectively, and 1.6% for the free-breathing volunteers (P = 0.13). The first gating strategy was defined as a fixed undersampling factor of 5 compared to a fully sampled 3-D radial acquisition, yielding significant VS improvement in coached volunteers and patients while myocardial signal-to-noise decreased in these. The second strategy was defined as a fixed gating window of 5.7 mm, leading to similar improvements. The presented strategies improve image quality of self-navigated acquisitions by retrospectively excluding data collected during end-inspiration.


  • Improved border sharpness of post-infarct scar by a novel self-navigated free-breathing high-resolution 3D whole-heart inversion recovery magnetic resonance approach

    by Tobias Rutz, Davide Piccini, Simone Coppo, Jerome Chaptinel, Giulia Ginami, Gabriella Vincenti, Matthias Stuber, Juerg Schwitter

    The border zone of post-infarction myocardial scar as identified by late gadolinium enhancement (LGE) has been identified as a substrate for arrhythmias and consequently, high-resolution 3D scar information is potentially useful for planning of electrophysiological interventions. This study evaluates the performance of a novel high-resolution 3D self-navigated free-breathing inversion recovery magnetic resonance pulse sequence (3D-SN-LGE) vs. conventional 2D breath-hold LGE (2D-LGE) with regard to sharpness of borders (SBorder) of post-infarction scar. Patients with post-infarction scar underwent two magnetic resonance examinations for conventional 2D-LGE and high-resolution 3D-SN-LGE acquisitions (both 15 min after 0.2 mmol/kg Gadobutrol IV) at 1.5T. In the prototype 3D-SN-LGE sequence, each ECG-triggered radial steady-state-free-precession read-out segment is preceded by a non-slice-selective inversion pulse. Scar volume and SBorder were assessed on 2D-LGE and matching reconstructed high-resolution 3D-SN-LGE short-axis slices. In 16 patients (four females, 58 ± 10y) all scars visualized by 2D-LGE could be identified on 3D-SN-LGE (time between 2D-LGE and 3D-SN-LGE 48 ± 53 days). A good agreement of scar volume by 3D-SN-LGE vs. 2D-LGE was found (Bland–Altman: −3.7 ± 3.4 ml, correlation: r = 0.987, p < 0.001) with a small difference in scar volume (20.5 (15.8, 35.2) ml vs. 24.5 (20.0, 41.9)) ml, respectively, p = 0.002] and a good intra- and interobserver variability (1.1 ± 4.1 and −1.1 ± 11.9 ml, respectively). SBorder of border “scar to non-infarcted myocardium” was superior on 3D-SN-LGE vs. 2D-LGE: 0.180 ± 0.044 vs. 0.083 ± 0.038, p < 0.001. Detection and quantification of myocardial scar by 3D-SN-LGE is feasible and accurate in comparison to 2D-LGE. The high spatial resolution of the 3D sequence improves delineation of scar borders.


  • Open Access

    WS08.1 Retrospectively self-gated three-dimensional MRI of the lung without contrast agent injection in CF patients

    by J. Delacoste, C. Beigelman, J. Chaptinel, D. Piccini, C. Rohner, M. Stuber, A. Sauty

  • Open Access

    Comparison of three diffusion encoding schemes for cardiac imaging under free breathing conditions.

    by Kévin Moulin, Alban Chazot, Jérôme Chaptinel, Pierre Croisille, Magalie Viallon


  • Open Access

    Breath-held high-resolution cardiac T2 mapping with SKRATCH

    by Emeline Lugand, Jérôme Yerly, Hélène Feliciano, Jérôme Chaptinel, Matthias Stuber, Ruud B van Heeswijk