Improved respiratory self‐navigation for 3D radial acquisitions through the use of a pencil‐beam 2D‐T2‐prep for free‐breathing, whole‐heart coronary MRA
- 31 May 2017
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (3) , 1293-1303
Abstract
Purpose: In respiratory self‐navigation (SN), signal from static structures, such as the chest wall, may complicate motion detection or introduce post‐correction artefacts. Suppressing signal from superfluous tissues may therefore improve image quality. We thus test the hypothesis that SN whole‐heart coronary magnetic resonance angiography (MRA) will benefit from an outer‐volume suppressing 2D‐T2‐Prep and present both phantom and in vivo results.Methods: A 2D‐T2‐Prep and a conventional T2‐Prep were used prior to a free‐breathing 3D‐radial SN sequence. Both techniques were compared by imaging a home‐built moving cardiac phantom and by performing coronary MRA in nine healthy volunteers. Reconstructions were performed using both a reference‐based and a reference‐independent approach to motion tracking, along with several coil combinations. Signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) were compared, along with vessel sharpness (VS).Results: In phantoms, using the 2D‐T2‐Prep increased SNR by 16% to 53% and mean VS by 8%; improved motion tracking precision was also achieved. In volunteers, SNR increased by an average of 29% to 33% in the blood pool and by 15% to 25% in the myocardium, depending on the choice of reconstruction coils and algorithm, and VS increased by 34%.Conclusion: A 2D‐T2‐Prep significantly improves image quality in both phantoms and volunteers when performing SN coronary MRA. Magn Reson Med 79:1293–1303, 2018. © 2017 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (P2LAP3_164909, 320030_143923, 326030_150828, PZ00P3‐154719)
This publication has 72 references indexed in Scilit:
- Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectoryMagnetic Resonance in Medicine, 2013
- Advanced Respiratory Motion Compensation for Coronary MR AngiographySensors, 2013
- 3D radial sampling and 3D affine transform-based respiratory motion correction technique for free-breathing whole-heart coronary MRA with 100% imaging efficiencyMagnetic Resonance in Medicine, 2011
- Comparison of self‐gated cine MRI retrospective cardiac synchronization algorithmsJournal of Magnetic Resonance Imaging, 2008
- A dual‐projection respiratory self‐gating technique for whole‐heart coronary MRAJournal of Magnetic Resonance Imaging, 2008
- Respiratory self‐gated four‐dimensional coronary MR angiography: A feasibility studyMagnetic Resonance in Medicine, 2008
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995
- A linear class of large-tip-angle selective excitation pulsesJournal of Magnetic Resonance (1969), 1989
- A k-space analysis of small-tip-angle excitationJournal of Magnetic Resonance (1969), 1989
- Localized proton spectroscopy using stimulated echoesJournal of Magnetic Resonance (1969), 1987