Paweł Borkowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paweł Borkowski has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Piotr Marek
Warsaw University of Technology
5 shared publications - Adam Dacko
Department of Mechanical Engineering, The University of Calgary, Calgary, Alberta, Canada
2 shared publications - Janusz Piechna
Warsaw University of Technology, Institute of Aeronautics and Applied Mechanics, Warsaw, Poland
2 shared publications - Konrad Kamieniecki
Institute of Micromechanics and Photonics, Warsaw University of Technology, Sw. A. Boboli 8, 02-525 Warsaw, Poland
2 shared publications - Mirosław Rodzewicz
Warsaw University of Technology, Warsaw, Poland
2 shared publications - Monika Kwacz
Affiliation Warsaw University of Technology, Institute of Micromechanics and Photonics, Warsaw, Poland
2 shared publications
Latest Publications
- 20 February 2026
- Published by SAGE Publications in International Journal of Damage Mechanics
- Vol. 35 (7) , 965-996
Peridynamic modeling of anisotropic materials: A comprehensive review
Peridynamics (PD) is a relatively new nonlocal method for modeling continua that inherently captures damage evolution, making it an attractive tool for modern engineering applications. Although significant research has focused on isotropic materials since its inception, this review article aims to synthesize studies on modeling material anisotropy within PD. To identify common patterns and approaches to the challenges encountered, key publications from the method's derivation onward have been thoroughly analyzed and categorized. The reviewed papers demonstrate an evolution from simple formulations to more comprehensive models capable of capturing a wide variety of anisotropic phenomena. Fiber composites and general anisotropic models have received the most attention, whereas applications in biomechanics, fluid dynamics, and multiphysics problems remain less explored. This review not only highlights the progress made in modeling anisotropic materials using PD but also identifies gaps in the current literature. This extensive categorization provides a roadmap for addressing the limitations of current models and advancing the practical implementation of PD in various engineering disciplines.
- 20 February 2026
- Published by SAGE Publications in International Journal of Damage Mechanics
- Vol. 35 (7) , 965-996
Peridynamic modeling of anisotropic materials: A comprehensive review
Peridynamics (PD) is a relatively new nonlocal method for modeling continua that inherently captures damage evolution, making it an attractive tool for modern engineering applications. Although significant research has focused on isotropic materials since its inception, this review article aims to synthesize studies on modeling material anisotropy within PD. To identify common patterns and approaches to the challenges encountered, key publications from the method's derivation onward have been thoroughly analyzed and categorized. The reviewed papers demonstrate an evolution from simple formulations to more comprehensive models capable of capturing a wide variety of anisotropic phenomena. Fiber composites and general anisotropic models have received the most attention, whereas applications in biomechanics, fluid dynamics, and multiphysics problems remain less explored. This review not only highlights the progress made in modeling anisotropic materials using PD but also identifies gaps in the current literature. This extensive categorization provides a roadmap for addressing the limitations of current models and advancing the practical implementation of PD in various engineering disciplines.
- 1 January 2019
- Vol. 21 (3) , 75-86
Bone conduction stimulation of the otic capsule: a finite element model of the temporal bone
Purpose: Bone conduction stimulation applied on the otic capsule may be used in a conductive hearing loss treatment as an alternative to the bone conduction implants in clinical practice. A finite element study was used to evaluate the force amplitude and direction needed for the stimulation. Methods: A finite element model of a female temporal bone with a precisely reconstructed cochlea was subjected to a harmonic analysis assuming two types of stimulation. At first, the displacement amplitude in the form of air conduction stimulation was applied on the stapes footplate. Then the force amplitude was applied on the otic capsule in the form of bone conduction stimulation. The two force directions were considered: 1) the primary direction, when a typical opening is performed during mastoidectomy, and was coincident with the axis of an imaginary cone, inscribed in the opening, and 2) the direction perpendicular to the stapes footplate. The force amplitude was set so that the response from the cochlea corresponded to the result of air conduction stimulation applied on the stapes footplate. Results: The amplitude and phase of vibration and the volume displacement on the round window membrane were considered as well as vibrations of the basilar membrane, spiral lamina, and promontory. Conclusions: The cochlear response was comparable for the two types of stimulation. The efficiency of bone conduction stimulation depended on the force direction. For the primary direction, the force was a few times smaller than for the direction perpendicular to the stapes footplate.
- 1 January 2019
- Vol. 21 (3) , 75-86
Bone conduction stimulation of the otic capsule: a finite element model of the temporal bone
Purpose: Bone conduction stimulation applied on the otic capsule may be used in a conductive hearing loss treatment as an alternative to the bone conduction implants in clinical practice. A finite element study was used to evaluate the force amplitude and direction needed for the stimulation. Methods: A finite element model of a female temporal bone with a precisely reconstructed cochlea was subjected to a harmonic analysis assuming two types of stimulation. At first, the displacement amplitude in the form of air conduction stimulation was applied on the stapes footplate. Then the force amplitude was applied on the otic capsule in the form of bone conduction stimulation. The two force directions were considered: 1) the primary direction, when a typical opening is performed during mastoidectomy, and was coincident with the axis of an imaginary cone, inscribed in the opening, and 2) the direction perpendicular to the stapes footplate. The force amplitude was set so that the response from the cochlea corresponded to the result of air conduction stimulation applied on the stapes footplate. Results: The amplitude and phase of vibration and the volume displacement on the round window membrane were considered as well as vibrations of the basilar membrane, spiral lamina, and promontory. Conclusions: The cochlear response was comparable for the two types of stimulation. The efficiency of bone conduction stimulation depended on the force direction. For the primary direction, the force was a few times smaller than for the direction perpendicular to the stapes footplate.
- 8 May 2018
- Published by Emerald Publishing in Aircraft Engineering and Aerospace Technology
- Vol. 90 (4) , 699-710
Structural dynamics of a gyrocopter: numerical approach in some emergency cases
Purpose: This paper aims to present the assumptions, analysis and sample results of numerical modeling and analysis of dynamic events encountered in emergency cases during deployment of parachute rescue system (PRS) and hard landing of a small gyrocopter. The optimal design requires knowledge of structural loads and structural response – the information obtained often from experiment. Numerical simulation is presented as an alternative tool for estimating these data. Design/methodology/approach: Structural analyses were performed using MSC.Nastran. Multibody simulations were done using MADYMO system. Findings: Initial design parameters were evaluated and verified in numerical simulations. Some of the resulting conclusions were proven during the test flights. Practical implications: Some chosen results of simulation of dynamic problems are presented. They can be useful as reference values for similar cases for light aircraft analysis. Originality/value: The paper presents an alternative way of assessing structural response parameters in the case of emergency dynamic events of usage of PRS. The results can be used in other projects.
- 8 May 2018
- Published by Emerald Publishing in Aircraft Engineering and Aerospace Technology
- Vol. 90 (4) , 699-710
Structural dynamics of a gyrocopter: numerical approach in some emergency cases
Purpose: This paper aims to present the assumptions, analysis and sample results of numerical modeling and analysis of dynamic events encountered in emergency cases during deployment of parachute rescue system (PRS) and hard landing of a small gyrocopter. The optimal design requires knowledge of structural loads and structural response – the information obtained often from experiment. Numerical simulation is presented as an alternative tool for estimating these data. Design/methodology/approach: Structural analyses were performed using MSC.Nastran. Multibody simulations were done using MADYMO system. Findings: Initial design parameters were evaluated and verified in numerical simulations. Some of the resulting conclusions were proven during the test flights. Practical implications: Some chosen results of simulation of dynamic problems are presented. They can be useful as reference values for similar cases for light aircraft analysis. Originality/value: The paper presents an alternative way of assessing structural response parameters in the case of emergency dynamic events of usage of PRS. The results can be used in other projects.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 050002
Effect of excitation direction on cochlear macro–mechanics during bone conduction stimulation
In many instances of hearing loss, audiological improvement can be made via direct excitation of a temporal bone (i.e., bone conduction). In order to design better and more efficient devices, the macro-mechanics of the bone conduction hearing pathway must be better understood. Based on previous empirical work, numerical models are useful. In this work, we present results of a time-domain Fluid Structure Interaction model that describes stimulation of the bone conduction pathway. The cochlea was modelled as uncoiled and consisted of an oval window, a round window, a basilar membrane and a helicotrema. In order to monitor pressure waves in the perilymph, the fluid was considered compressible. The excitation, in form of sinusoidal velocity, was applied to the cochlea bony walls. The system was excited in three perpendicular directions: along the basilar membrane, perpendicularly to the membrane and transversely to the membrane. The numerical simulation examined which stimulation direction maximally excited the basilar membrane, the pressure distributions for each excitation direction, and the associated mechanics.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1965 (1) , 050002
Effect of excitation direction on cochlear macro–mechanics during bone conduction stimulation
In many instances of hearing loss, audiological improvement can be made via direct excitation of a temporal bone (i.e., bone conduction). In order to design better and more efficient devices, the macro-mechanics of the bone conduction hearing pathway must be better understood. Based on previous empirical work, numerical models are useful. In this work, we present results of a time-domain Fluid Structure Interaction model that describes stimulation of the bone conduction pathway. The cochlea was modelled as uncoiled and consisted of an oval window, a round window, a basilar membrane and a helicotrema. In order to monitor pressure waves in the perilymph, the fluid was considered compressible. The excitation, in form of sinusoidal velocity, was applied to the cochlea bony walls. The system was excited in three perpendicular directions: along the basilar membrane, perpendicularly to the membrane and transversely to the membrane. The numerical simulation examined which stimulation direction maximally excited the basilar membrane, the pressure distributions for each excitation direction, and the associated mechanics.
- 29 March 2017
- Published by Springer Nature in Lecture Notes in Mechanical Engineering
- p. 49-61
Synthesis and Structural Analysis of High Strength Composite Flexible Landing Gear Legs
- 29 March 2017
- Published by Springer Nature in Lecture Notes in Mechanical Engineering
- p. 49-61
Synthesis and Structural Analysis of High Strength Composite Flexible Landing Gear Legs
- Open Access
- 1 January 2017
- Published by Elsevier in Procedia IUTAM
- Vol. 24, 48-63
Basilar Membrane Vibration in Time Domain Predicted by Fluid–Structure Interaction Model in Pre- and Post-stapedotomy State
- 1 January 2017
- Published by Elsevier in Procedia IUTAM
- Vol. 24, 48-63
Open AccessBasilar Membrane Vibration in Time Domain Predicted by Fluid–Structure Interaction Model in Pre- and Post-stapedotomy State
- Open Access
- 1 March 2016
- Published by Walter de Gruyter GmbH in Archive of Mechanical Engineering
- Vol. 63 (1) , 163-185
Fe Analysis of a Steam Turbine HP Rotor Blade Stage Concerning Material Effort, Dynamic Properties and Creep Damage Assessment
This paper is concerned with the 1st stage of HP rotor blade assembly steam turbine TK 120. The methodology was focused on the selection of mechanical properties and the way of the rotor disc modeling and estimating the degree of damage caused by creep. Then the dynamic interference between the frequencies of excitation and the natural frequencies was assessed. Static calculations were performed for the cyclic sectors consisting of the disc, disc blades, spacers and shrouding, including loads as temperature, mass forces from the angular velocity and the pressure on the blades. Then, the creep analysis using a Norton’s model and the modal analysis were performed. Static analysis gave information concerning the distributions of displacements, stress and strain components. In the creep analysis, the creep displacements and stress relaxation versus time were determined and the estimated degree of damage caused by creep was evaluated at each part of the rotor disc. In the modal analysis, the natural frequencies and modes of vibrations corresponding to the nodal diameters were found. The results of modal analysis were shown in the SAFE graph. Numerical calculations have shown that the rotor disc was a well-designed structure and did not reveal any dynamic interference.
- 1 March 2016
- Published by Walter de Gruyter GmbH in Archive of Mechanical Engineering
- Vol. 63 (1) , 163-185
Open AccessFe Analysis of a Steam Turbine HP Rotor Blade Stage Concerning Material Effort, Dynamic Properties and Creep Damage Assessment
This paper is concerned with the 1st stage of HP rotor blade assembly steam turbine TK 120. The methodology was focused on the selection of mechanical properties and the way of the rotor disc modeling and estimating the degree of damage caused by creep. Then the dynamic interference between the frequencies of excitation and the natural frequencies was assessed. Static calculations were performed for the cyclic sectors consisting of the disc, disc blades, spacers and shrouding, including loads as temperature, mass forces from the angular velocity and the pressure on the blades. Then, the creep analysis using a Norton’s model and the modal analysis were performed. Static analysis gave information concerning the distributions of displacements, stress and strain components. In the creep analysis, the creep displacements and stress relaxation versus time were determined and the estimated degree of damage caused by creep was evaluated at each part of the rotor disc. In the modal analysis, the natural frequencies and modes of vibrations corresponding to the nodal diameters were found. The results of modal analysis were shown in the SAFE graph. Numerical calculations have shown that the rotor disc was a well-designed structure and did not reveal any dynamic interference.
- 1 April 2014
- Published by Elsevier in Hearing Research
- Vol. 310, 13-26
Effect of different stapes prostheses on the passive vibration of the basilar membrane
- 1 April 2014
- Published by Elsevier in Hearing Research
- Vol. 310, 13-26
Effect of different stapes prostheses on the passive vibration of the basilar membrane
- Open Access
- 5 March 2013
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 12 (6) , 1243-1261
A three-dimensional finite element model of round window membrane vibration before and after stapedotomy surgery
Piston stapes prostheses are implanted in patients with refractory conductive or mixed hearing loss due to stapes otosclerosis to stimulate the perilymph with varying degrees of success. The overclosure effect described by the majority of researchers affects mainly low and medium frequencies, and a large number of patients report a lack of satisfactory results for frequencies above 2 kHz. The mechanics of perilymph stimulation with the piston have not been studied in a systematic manner. The objective of this study was to assess the influence of stapedotomy surgery on round window membrane vibration and to estimate the postoperative outcomes using the finite element (FE) method. The study hypothesis is that the three-dimensional FE model developed of the human inner ear, which simulates the round window (RW) membrane vibration, can be used to assess the influence of stapedotomy on auditory outcomes achieved after the surgical procedure. An additional objective of the study was to enable the simulation of RW membrane vibration after stapedotomy using a new type of stapes prosthesis currently under investigation at Warsaw University of Technology. A three-dimensional finite element (FE) model of the human inner ear was developed and validated using experimental data. The model was then used to simulate the round window membrane vibration before and after stapedotomy surgery. Functional alterations of the RW membrane vibration were derived from the model and compared with the results of experimental measurements from temporal bones of a human cadaver. Piston stapes prosthesis implantation causes an approximately fivefold (14 dB) lower amplitude of the RW membrane vibrations compared with normal anatomical conditions. A satisfactory agreement between the FE model and the experimental data was found. The new prosthesis caused an increase of 20–30 dB in the RW displacement amplitude compared with the 0.4-mm piston prosthesis. In all frequencies, the FE model predicted a RW displacement curve that was above the experimental curves for the normal ear. The stapedotomy can be well simulated by the FE model to predict the auditory outcomes achieved following this otosurgery procedure. The 3D FE model developed in this study may be used to optimize the geometry of a new type of stapes prosthesis in order to achieve a similar sound transmission through the inner ear as for a normal middle ear. This should provide better auditory outcomes for patients with stapedial otosclerosis.
- 5 March 2013
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 12 (6) , 1243-1261
Open AccessA three-dimensional finite element model of round window membrane vibration before and after stapedotomy surgery
Piston stapes prostheses are implanted in patients with refractory conductive or mixed hearing loss due to stapes otosclerosis to stimulate the perilymph with varying degrees of success. The overclosure effect described by the majority of researchers affects mainly low and medium frequencies, and a large number of patients report a lack of satisfactory results for frequencies above 2 kHz. The mechanics of perilymph stimulation with the piston have not been studied in a systematic manner. The objective of this study was to assess the influence of stapedotomy surgery on round window membrane vibration and to estimate the postoperative outcomes using the finite element (FE) method. The study hypothesis is that the three-dimensional FE model developed of the human inner ear, which simulates the round window (RW) membrane vibration, can be used to assess the influence of stapedotomy on auditory outcomes achieved after the surgical procedure. An additional objective of the study was to enable the simulation of RW membrane vibration after stapedotomy using a new type of stapes prosthesis currently under investigation at Warsaw University of Technology. A three-dimensional finite element (FE) model of the human inner ear was developed and validated using experimental data. The model was then used to simulate the round window membrane vibration before and after stapedotomy surgery. Functional alterations of the RW membrane vibration were derived from the model and compared with the results of experimental measurements from temporal bones of a human cadaver. Piston stapes prosthesis implantation causes an approximately fivefold (14 dB) lower amplitude of the RW membrane vibrations compared with normal anatomical conditions. A satisfactory agreement between the FE model and the experimental data was found. The new prosthesis caused an increase of 20–30 dB in the RW displacement amplitude compared with the 0.4-mm piston prosthesis. In all frequencies, the FE model predicted a RW displacement curve that was above the experimental curves for the normal ear. The stapedotomy can be well simulated by the FE model to predict the auditory outcomes achieved following this otosurgery procedure. The 3D FE model developed in this study may be used to optimize the geometry of a new type of stapes prosthesis in order to achieve a similar sound transmission through the inner ear as for a normal middle ear. This should provide better auditory outcomes for patients with stapedial otosclerosis.
- 1 January 2012
- Vol. 14 (1) , 59-66
Finite element analysis of artificial disc with an elastomeric core in the lumbar spine.
This paper presents the application of finite element method in an artificial disc modelling. The prosthesis consisted of two metal plates and a flexible elastomeric core made of the nanocomposite polyurethane. Two types of connections between the plates and the core were compared: the device with an integral inlay and the device with a separate inlay coming into contact with the plates. The artificial disc with a separate inlay imitated better the human intervertebral disc. The main target of this paper was to evaluate the characteristics of force-displacement and moment-angle for the new design of the prosthesis with a separate inlay under compression, sagittal bending, shear and axial rotation. For some analyzed cases except the axial rotation and shear, where the prosthesis was too flexible, the results were roughly similar to those observed in the human spinal segment. The material effort in the prosthesis under compressive load was comparable in both types of connections between the plates and the core.
- 1 January 2012
- Vol. 14 (1) , 59-66
Finite element analysis of artificial disc with an elastomeric core in the lumbar spine.
This paper presents the application of finite element method in an artificial disc modelling. The prosthesis consisted of two metal plates and a flexible elastomeric core made of the nanocomposite polyurethane. Two types of connections between the plates and the core were compared: the device with an integral inlay and the device with a separate inlay coming into contact with the plates. The artificial disc with a separate inlay imitated better the human intervertebral disc. The main target of this paper was to evaluate the characteristics of force-displacement and moment-angle for the new design of the prosthesis with a separate inlay under compression, sagittal bending, shear and axial rotation. For some analyzed cases except the axial rotation and shear, where the prosthesis was too flexible, the results were roughly similar to those observed in the human spinal segment. The material effort in the prosthesis under compressive load was comparable in both types of connections between the plates and the core.