Ivana Dimic
Ivana Dimic has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Ivana Cvijović-Alagić
Center of Excellence “CEXTREME LAB”, Vinča Institute of Nuclear Sciences - National Institute of the Republic of Serbia, University of Belgrade, Belgrade, Serbia
7 shared publications Marko Rakin
University of Belgrade, Faculty of Technology and Metallurgy, 11120, Belgrade, Serbia
4 shared publicationsSlavisa Putic
Faculty of Technology and Metallurgy, Belgrade
4 shared publicationsBranko Bugarski
3 shared publicationsJelena Petrovic
Faculty of Technology and Metallurgy, Belgrade
3 shared publications- Dragana R. Barjaktarević
Faculty of Technology and Metallurgy, University of Belgrade, Karnegijeva 4, 11000 Belgrade, Serbia
2 shared publications
Latest Publications
- Open Access
- 1 December 2017
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 24 (6) , 1689-1695
Corrosion resistance of high pressure torsion obtained commercially pure titanium in acidic solution
Poboljšanje mehaničkih svojstava komercijalno čistog titana (cpTi), koje je neophodno za njegovu medicinsku primjenu, može se postići usitnjavanjem mikrostrukture primjenom procesa jakog plastičnog deformiranja. Osim poboljšanih...
- 1 December 2017
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 24 (6) , 1689-1695
Open AccessCorrosion resistance of high pressure torsion obtained commercially pure titanium in acidic solution
Poboljšanje mehaničkih svojstava komercijalno čistog titana (cpTi), koje je neophodno za njegovu medicinsku primjenu, može se postići usitnjavanjem mikrostrukture primjenom procesa jakog plastičnog deformiranja. Osim poboljšanih...
- 15 May 2017
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (3) , 1097-1107
Electrochemical and biocompatibility examinations of high‐pressure torsion processed titanium and Ti–13Nb–13Zr alloy
The purpose of this study was to estimate the electrochemical behavior and biocompatibility of ultrafine‐grained (UFG) commercially pure titanium (CPTi) and Ti–13Nb–13Zr (TNZ) alloy obtained by high‐pressure torsion process. Electrochemical behavior of materials in artificial saliva at 37°C was evaluated by potentiodynamic polarization tests and electrochemical impedance spectroscopy (EIS), and the obtained results indicated that UFG TNZ alloy showed corrosion current density (jcorr = 53 ± 5 nA cm−2) which was 2 times lower compared to coarse‐grained (CG) TNZ alloy (jcorr = 110 ± 12 nA cm−2) and higher corrosion resistance, while UFG CPTi and CPTi showed approximately the same corrosion rate (mean jcorr ∼ 38–40 nA cm−2). Static immersion test in artificial saliva, performed in this study, showed that the released ion concentrations from UFG materials were more than 10 times lower than the permitted concentration (the highest released Ti ion concentration from UFG CPTi and UFG TNZ alloy was 1.12 and 1.28 ppb, respectively, while permitted concentration was 15.5 ppb). The in vitro cytotoxicity tests, as the initial phase of the biocompatibility evaluation, showed that the fraction of surviving cells in all examined materials was much higher compared to the control sample and hence demonstrated absence of cytotoxicity and an increase of fibroblast cells adhesion on UFG materials surfaces. UFG CPTi and UFG TNZ alloy can be considered as promising materials for applications in dentistry due to high corrosion resistance and outstanding biocompatibility which were shown in this study. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1097–1107, 2018.
- 15 May 2017
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (3) , 1097-1107
Electrochemical and biocompatibility examinations of high‐pressure torsion processed titanium and Ti–13Nb–13Zr alloy
The purpose of this study was to estimate the electrochemical behavior and biocompatibility of ultrafine‐grained (UFG) commercially pure titanium (CPTi) and Ti–13Nb–13Zr (TNZ) alloy obtained by high‐pressure torsion process. Electrochemical behavior of materials in artificial saliva at 37°C was evaluated by potentiodynamic polarization tests and electrochemical impedance spectroscopy (EIS), and the obtained results indicated that UFG TNZ alloy showed corrosion current density (jcorr = 53 ± 5 nA cm−2) which was 2 times lower compared to coarse‐grained (CG) TNZ alloy (jcorr = 110 ± 12 nA cm−2) and higher corrosion resistance, while UFG CPTi and CPTi showed approximately the same corrosion rate (mean jcorr ∼ 38–40 nA cm−2). Static immersion test in artificial saliva, performed in this study, showed that the released ion concentrations from UFG materials were more than 10 times lower than the permitted concentration (the highest released Ti ion concentration from UFG CPTi and UFG TNZ alloy was 1.12 and 1.28 ppb, respectively, while permitted concentration was 15.5 ppb). The in vitro cytotoxicity tests, as the initial phase of the biocompatibility evaluation, showed that the fraction of surviving cells in all examined materials was much higher compared to the control sample and hence demonstrated absence of cytotoxicity and an increase of fibroblast cells adhesion on UFG materials surfaces. UFG CPTi and UFG TNZ alloy can be considered as promising materials for applications in dentistry due to high corrosion resistance and outstanding biocompatibility which were shown in this study. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1097–1107, 2018.
- Open Access
- 3 September 2016
- Published by TechnoFit Academic Publishers LLC in Metallurgical and Materials Engineering
- Vol. 22 (3) , 129-144
Anodization of Ti-based materials for biomedical applications: A review
Commercially pure titanium (cpTi) and titanium alloys are the most commonly used metallic biomaterials. Biomedical requirements for the successful usage of metallic implant materials include their high mechanical strength, low elastic modulus, excellent biocompatibility and high corrosion resistance. It is evident that the response of a biomaterial implanted into the human body depends entirely on its biocompatibility and surface properties. Therefore, in order to improve the performance of biomaterials in biological systems modification of their surface is necessary. One of most commonly used method of implant materials surface modification is electrochemical anodization and this method is reviewed in the present work.Aim of the presented review article is to explain the electrochemical anodization process and the way in which the nanotubes are formed by anodization on the metallic material surface. Influence of anodizing parameters on the nanotubes characteristics, such as nanotube diameter, length and nanotubular layer thickness, are described, as well as the anodized nanotubes influence on the material surface properties, corrosion resistance and biocompatibility.
- 3 September 2016
- Published by TechnoFit Academic Publishers LLC in Metallurgical and Materials Engineering
- Vol. 22 (3) , 129-144
Open AccessAnodization of Ti-based materials for biomedical applications: A review
Commercially pure titanium (cpTi) and titanium alloys are the most commonly used metallic biomaterials. Biomedical requirements for the successful usage of metallic implant materials include their high mechanical strength, low elastic modulus, excellent biocompatibility and high corrosion resistance. It is evident that the response of a biomaterial implanted into the human body depends entirely on its biocompatibility and surface properties. Therefore, in order to improve the performance of biomaterials in biological systems modification of their surface is necessary. One of most commonly used method of implant materials surface modification is electrochemical anodization and this method is reviewed in the present work.Aim of the presented review article is to explain the electrochemical anodization process and the way in which the nanotubes are formed by anodization on the metallic material surface. Influence of anodizing parameters on the nanotubes characteristics, such as nanotube diameter, length and nanotubular layer thickness, are described, as well as the anodized nanotubes influence on the material surface properties, corrosion resistance and biocompatibility.
- 1 February 2016
- Published by Elsevier in Materials & Design
- Vol. 91, 340-347
Microstructure and metallic ion release of pure titanium and Ti–13Nb–13Zr alloy processed by high pressure torsion
- 1 February 2016
- Published by Elsevier in Materials & Design
- Vol. 91, 340-347
Microstructure and metallic ion release of pure titanium and Ti–13Nb–13Zr alloy processed by high pressure torsion
- Open Access
- 1 January 2015
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 80 (12) , 1541-1552
In vitro biocompatibility assessment of Co-Cr-Mo dental cast alloy
Metallic materials, such as Co-Cr-Mo alloys, are exposed to aggressive conditions in the oral cavity which represents ideal environment for metallic ion release and biodegradation. The released metallic ions from dental materials can cause local and/or systemic adverse effects in the human body. Therefore, the dental materials are required to possess appropriate mechanical, physical, chemical and biological properties. The biocompatibility of metallic materials is very important for dental applications. Accordingly, the aim of this study was to examine metallic ion release and cytotoxicity of Co-30Cr-5Mo cast alloy as the initial phase of biocompatibility evaluation. Determination of human (MRC-5) and animal (L929) fibroblast cells viability was conducted using three in vitro test methods: colorimetric methyl-thiazol-tetrazolium (MTT) test, dye exclusion test (DET) and agar diffusion test (ADT). Furthermore, the cells morphology and growth were analyzed using scanning electron microscopy (SEM). The obtained results indicated that Co-30Cr-5Mo alloy did not release harmful elements in high concentrations that could cause detrimental effects on human and animal fibroblasts under the given experimental conditions. Moreover, the fibroblast cells showed good adhesion on the Co-30Cr-5Mo alloy surface. Therefore, it can be concluded that Co-30Cr-5Mo alloy is biocompatible material which can be safely used in dentistry.
- 1 January 2015
- Published by National Library of Serbia in Journal of the Serbian Chemical Society
- Vol. 80 (12) , 1541-1552
Open AccessIn vitro biocompatibility assessment of Co-Cr-Mo dental cast alloy
Metallic materials, such as Co-Cr-Mo alloys, are exposed to aggressive conditions in the oral cavity which represents ideal environment for metallic ion release and biodegradation. The released metallic ions from dental materials can cause local and/or systemic adverse effects in the human body. Therefore, the dental materials are required to possess appropriate mechanical, physical, chemical and biological properties. The biocompatibility of metallic materials is very important for dental applications. Accordingly, the aim of this study was to examine metallic ion release and cytotoxicity of Co-30Cr-5Mo cast alloy as the initial phase of biocompatibility evaluation. Determination of human (MRC-5) and animal (L929) fibroblast cells viability was conducted using three in vitro test methods: colorimetric methyl-thiazol-tetrazolium (MTT) test, dye exclusion test (DET) and agar diffusion test (ADT). Furthermore, the cells morphology and growth were analyzed using scanning electron microscopy (SEM). The obtained results indicated that Co-30Cr-5Mo alloy did not release harmful elements in high concentrations that could cause detrimental effects on human and animal fibroblasts under the given experimental conditions. Moreover, the fibroblast cells showed good adhesion on the Co-30Cr-5Mo alloy surface. Therefore, it can be concluded that Co-30Cr-5Mo alloy is biocompatible material which can be safely used in dentistry.
- Open Access
- 1 January 2014
- Published by National Library of Serbia in Chemical Industry and Chemical Engineering Quarterly
- Vol. 20 (4) , 571-577
Metallic ion release from biocompatible cobalt-based alloy
Metallic biomaterials, which are mainly used for the damaged hard tissue replacements, are materials with high strength, excellent toughness and good wear resistance. The disadvantages of metals as implant materials are their susceptibility to corrosion, the elastic modulus mismatch between metals and human hard tissues, relatively high density and metallic ion release which can cause serious health problems. The aim of this study was to examine metallic ion release from Co-Cr-Mo alloy in artificial saliva. In that purpose, alloy samples were immersed into artificial saliva with different pH values (4.0, 5.5 and 7.5). After a certain immersion period (1, 3 and 6 weeks) the concentrations of released ions were determined using Inductively Coupled Plasma - Mass Spectrophotometer (ICP-MS). The research findings were used in order to define the dependence between the concentration of released metallic ions, artificial saliva pH values and immersion time. The determined released metallic ions concentrations were compared with literature data in order to describe and better understand the phenomenon of metallic ion release from the biocompatible cobalt-based alloy.
- 1 January 2014
- Published by National Library of Serbia in Chemical Industry and Chemical Engineering Quarterly
- Vol. 20 (4) , 571-577
Open AccessMetallic ion release from biocompatible cobalt-based alloy
Metallic biomaterials, which are mainly used for the damaged hard tissue replacements, are materials with high strength, excellent toughness and good wear resistance. The disadvantages of metals as implant materials are their susceptibility to corrosion, the elastic modulus mismatch between metals and human hard tissues, relatively high density and metallic ion release which can cause serious health problems. The aim of this study was to examine metallic ion release from Co-Cr-Mo alloy in artificial saliva. In that purpose, alloy samples were immersed into artificial saliva with different pH values (4.0, 5.5 and 7.5). After a certain immersion period (1, 3 and 6 weeks) the concentrations of released ions were determined using Inductively Coupled Plasma - Mass Spectrophotometer (ICP-MS). The research findings were used in order to define the dependence between the concentration of released metallic ions, artificial saliva pH values and immersion time. The determined released metallic ions concentrations were compared with literature data in order to describe and better understand the phenomenon of metallic ion release from the biocompatible cobalt-based alloy.
- Open Access
- 1 January 2013
- Published by National Library of Serbia in Acta Periodica Technologica
- No. 44,p. 207-215
Effect of the pH of artificial saliva on ion release from commercially pure titanium
Due to their excellent characteristics, such as chemical inertness, mechanical resistance, low Young?s modulus, high corrosion resistance, and outstanding biocompatibility, titanium and its alloys are the most used metallic materials for biomedical applications. In dental practice, these materials have demonstrated success as biomedical devices which are used for repairing and replacing failed hard tissue. However, the oral cavity is constantly subjected to the changes in the pH value changes and such an environment is strongly corrosive for titanium dental implants. The objective of this study was to examine ion release from commercially pure titanium (cpTi) in artificial saliva with different pH values (4.0, 5.5 and 7.5). The concentrations of released titanium ions were determined after 1, 3 and 6 weeks using Inductively Coupled Plasma - Mass Spectrometry. The results indicate that the ion release from commercially pure titanium in the artificial saliva is dependent both on the pH of artificial saliva and duration of immersion.
- 1 January 2013
- Published by National Library of Serbia in Acta Periodica Technologica
- No. 44,p. 207-215
Open AccessEffect of the pH of artificial saliva on ion release from commercially pure titanium
Due to their excellent characteristics, such as chemical inertness, mechanical resistance, low Young?s modulus, high corrosion resistance, and outstanding biocompatibility, titanium and its alloys are the most used metallic materials for biomedical applications. In dental practice, these materials have demonstrated success as biomedical devices which are used for repairing and replacing failed hard tissue. However, the oral cavity is constantly subjected to the changes in the pH value changes and such an environment is strongly corrosive for titanium dental implants. The objective of this study was to examine ion release from commercially pure titanium (cpTi) in artificial saliva with different pH values (4.0, 5.5 and 7.5). The concentrations of released titanium ions were determined after 1, 3 and 6 weeks using Inductively Coupled Plasma - Mass Spectrometry. The results indicate that the ion release from commercially pure titanium in the artificial saliva is dependent both on the pH of artificial saliva and duration of immersion.
- Open Access
- 1 January 2013
- Published by National Library of Serbia in Acta Periodica Technologica
- No. 44,p. 151-162
Microstructural characterization of glass-epoxy composites subjected to tensile testing
The main objective of the research presented in this paper was to carry out a statistical-mechanical analysis concerning the tensile test of glass-epoxy composite materials in order to calculate their relevant tension properties and micromechanical structure destruction process. The analysis was done at room temperature, and its results were derived based on the structure of the glass woven 280 g/m?, ?twill texture? with the width value of 100 cm, type - Interglass 92125, and epoxy resin type MGS L 135. Samples were shaped by hands with 35% of fabric volume part. The consumed portion of resin was 220 g/m?, the thickness of the laminate was 0.308 mm, and the mass of the laminate was 500 g/m2. There were a total of eight layers built in the panel. The micromechanical analysis was derived from the crack surfaces data collected on a scanning electronic microscope, and it showed the mechanisms of damage, and development of cracks until the occurrence of the final break under the tension load.
- 1 January 2013
- Published by National Library of Serbia in Acta Periodica Technologica
- No. 44,p. 151-162
Open AccessMicrostructural characterization of glass-epoxy composites subjected to tensile testing
The main objective of the research presented in this paper was to carry out a statistical-mechanical analysis concerning the tensile test of glass-epoxy composite materials in order to calculate their relevant tension properties and micromechanical structure destruction process. The analysis was done at room temperature, and its results were derived based on the structure of the glass woven 280 g/m?, ?twill texture? with the width value of 100 cm, type - Interglass 92125, and epoxy resin type MGS L 135. Samples were shaped by hands with 35% of fabric volume part. The consumed portion of resin was 220 g/m?, the thickness of the laminate was 0.308 mm, and the mass of the laminate was 500 g/m2. There were a total of eight layers built in the panel. The micromechanical analysis was derived from the crack surfaces data collected on a scanning electronic microscope, and it showed the mechanisms of damage, and development of cracks until the occurrence of the final break under the tension load.
- Open Access
- 1 January 2012
- Published by National Library of Serbia in Acta Periodica Technologica
- No. 43,p. 189-198
Tension mechanical properties of recycled glass-epoxy composite material
The significance of composite materials and their applications are mainly due to their good properties. This imposes the need for their recycling, thus extending their lifetime. Once used composite material will be disposed as a waste at the end of it service life. After recycling, this kind of waste can be used as raw materials for the production of same material, which raises their applicability. This indicates a great importance of recycling as a method of the renowal of composite materials. This study represents a contribution to the field of mechanical properties of the recycled composite materials. The tension mechanical properties (tensile strength and modulus of elasticity) of once used and disposed glass-epoxy composite material were compared before and after the recycling. The obtained results from mechanical tests confirmed that the applied recycling method was suitable for glass-epoxy composite materials. In respect to the tensile strength and modulus of elasticity it can be further assessed the possibility of use of recycled glass-epoxy composite materials.
- 1 January 2012
- Published by National Library of Serbia in Acta Periodica Technologica
- No. 43,p. 189-198
Open AccessTension mechanical properties of recycled glass-epoxy composite material
The significance of composite materials and their applications are mainly due to their good properties. This imposes the need for their recycling, thus extending their lifetime. Once used composite material will be disposed as a waste at the end of it service life. After recycling, this kind of waste can be used as raw materials for the production of same material, which raises their applicability. This indicates a great importance of recycling as a method of the renowal of composite materials. This study represents a contribution to the field of mechanical properties of the recycled composite materials. The tension mechanical properties (tensile strength and modulus of elasticity) of once used and disposed glass-epoxy composite material were compared before and after the recycling. The obtained results from mechanical tests confirmed that the applied recycling method was suitable for glass-epoxy composite materials. In respect to the tensile strength and modulus of elasticity it can be further assessed the possibility of use of recycled glass-epoxy composite materials.