Marek Korzeniewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marek Korzeniewski has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Sikorski
Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland
8 shared publications - Krzysztof Kulikowski
Department of Electrotechnics, Power Electronics and Electrical Power Engineering, Biaystok University of Technology, Biaystok, Poland
3 shared publications - Adam Ruszczyk
Bialystok Technical University, Dep. of Power Electronics and Electrical Drives, Bialystok, Poland
2 shared publications - Marek Jasinski
Institute of Control and Industrial Electronics, Warsaw University of Technology, 00-662 Warsaw, Poland
2 shared publications - Piotr Falkowski
Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland
2 shared publications - Agata Godlewska
Department of Power Electronics and Electric Drives, Bialystok University of Technology, Biaystok, Poland
1 shared publication
Latest Publications
- Open Access
Comparison of Two Power Converter Topologies in Wind Turbine System
The article presents comprehensive results of research on two representative topologies of converters used in the path of processing energy generated in a wind turbine and transmitted to the grid. The topology T1 uses a two-level transistor-controlled rectifier as a converter from the generator side, while the T2 topology uses DC/DC boost converter. In both topologies, a three-level back-to-back converter with a line filter L was used as a grid converter. The conclusions indicate the tendency of changes in power losses depending on the aforementioned parameters and can be used at the stage of deciding on the choice of topology, operating parameters or selection of control methods depending on the specific operating conditions of the wind turbine.
Open AccessComparison of Two Power Converter Topologies in Wind Turbine System
The article presents comprehensive results of research on two representative topologies of converters used in the path of processing energy generated in a wind turbine and transmitted to the grid. The topology T1 uses a two-level transistor-controlled rectifier as a converter from the generator side, while the T2 topology uses DC/DC boost converter. In both topologies, a three-level back-to-back converter with a line filter L was used as a grid converter. The conclusions indicate the tendency of changes in power losses depending on the aforementioned parameters and can be used at the stage of deciding on the choice of topology, operating parameters or selection of control methods depending on the specific operating conditions of the wind turbine.
- 2 January 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (1) , 123-126
Development of a hybrid gas and electrical installation for direct-injected engine vehicles
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informujące swoich czytelników o najnowszych osiągnięciach naukowych i nowoczesnych rozwiązaniach technicznych w Polsce i na świecie, popularyzuje problemy techniczne oraz poszerza wiedzę i kulturę techniczną.
- 2 January 2021
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (1) , 123-126
Development of a hybrid gas and electrical installation for direct-injected engine vehicles
Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informujące swoich czytelników o najnowszych osiągnięciach naukowych i nowoczesnych rozwiązaniach technicznych w Polsce i na świecie, popularyzuje problemy techniczne oraz poszerza wiedzę i kulturę techniczną.
- Open Access
- 1 December 2016
- Published by Walter de Gruyter GmbH in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 64 (4) , 887-896
Implementation of a Web-based remote control system for qZS DAB application using low-cost ARM platform
Continuous development of intelligent network applications drives the demand for deployment-ready hardware and software solutions. Such solutions are highly valued not only by distributed producers of energy but by energy consumers as well. The use of intelligent network applications enables the development and improvement of the quality of services. It also increases self-sufficiency and efficiency. This paper describes an example of such device that allows for the control of a dual active bridge (DAB) converter and enables its remote control in real time over an IP-based network. The details of both hardware and software components of proposed implementation are provided. The DAB converter gives a possibility to control and manage the energy between two DC power systems with very different voltage levels. Not only information, but also the quality of energy, the direction of power flow, and energy storage systems can be easily controlled through an IP-based network and power electronics converters. Information technology, together with intelligent control of power electronics technology, provides a flexible solution, especially for sustainable smart grids.
- 1 December 2016
- Published by Walter de Gruyter GmbH in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 64 (4) , 887-896
Open AccessImplementation of a Web-based remote control system for qZS DAB application using low-cost ARM platform
Continuous development of intelligent network applications drives the demand for deployment-ready hardware and software solutions. Such solutions are highly valued not only by distributed producers of energy but by energy consumers as well. The use of intelligent network applications enables the development and improvement of the quality of services. It also increases self-sufficiency and efficiency. This paper describes an example of such device that allows for the control of a dual active bridge (DAB) converter and enables its remote control in real time over an IP-based network. The details of both hardware and software components of proposed implementation are provided. The DAB converter gives a possibility to control and manage the energy between two DC power systems with very different voltage levels. Not only information, but also the quality of energy, the direction of power flow, and energy storage systems can be easily controlled through an IP-based network and power electronics converters. Information technology, together with intelligent control of power electronics technology, provides a flexible solution, especially for sustainable smart grids.
- 1 October 2016
- Published by Springer Nature
- p. 221-302
Advanced Control Methods of DC/AC and AC/DC Power Converters—Look-Up Table and Predictive Algorithms
- 1 October 2016
- Published by Springer Nature
- p. 221-302
Advanced Control Methods of DC/AC and AC/DC Power Converters—Look-Up Table and Predictive Algorithms
- Open Access
- 1 December 2013
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 61 (4) , 771-778
Modern Direct Torque and Flux Control methods of an induction machine supplied by three-level inverter
: This paper describes two modern direct torque and flux control methods of an induction machine supplied by a three-level inverter. Additionally, it presents a comparison of the methods both in static and dynamic states. The methods, in a specific way, make use of an increased number of active vectors of the three-level inverter in order to improve control quality and reduce switching frequency. The two methods modify the DTC method by using its advantages and eliminating, at the same time its drawbacks. In static states the comparison was based on the results of investigations performed for two different load values and three set values of angular speed, whereas in dynamic states the comparison was focused on the behavior of the machine at startup. The results of the investigations have shown that both methods give very good performance. They are characterized by both sinusoidal shape of flux and low current deformations even at low angular speeds i.e. less than 10% of the nominal value. The presented methods also allow to generate nominal flux for set zero angular speed in order to achieve excitation of the induction machine. The switching frequencies for both methods are very similar in almost the whole range of control but the methods have shown some differences in control quality, particularly for higher torque values.
- 1 December 2013
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 61 (4) , 771-778
Open AccessModern Direct Torque and Flux Control methods of an induction machine supplied by three-level inverter
: This paper describes two modern direct torque and flux control methods of an induction machine supplied by a three-level inverter. Additionally, it presents a comparison of the methods both in static and dynamic states. The methods, in a specific way, make use of an increased number of active vectors of the three-level inverter in order to improve control quality and reduce switching frequency. The two methods modify the DTC method by using its advantages and eliminating, at the same time its drawbacks. In static states the comparison was based on the results of investigations performed for two different load values and three set values of angular speed, whereas in dynamic states the comparison was focused on the behavior of the machine at startup. The results of the investigations have shown that both methods give very good performance. They are characterized by both sinusoidal shape of flux and low current deformations even at low angular speeds i.e. less than 10% of the nominal value. The presented methods also allow to generate nominal flux for set zero angular speed in order to achieve excitation of the induction machine. The switching frequencies for both methods are very similar in almost the whole range of control but the methods have shown some differences in control quality, particularly for higher torque values.
- Open Access
- 20 January 2013
- Published by Taylor & Francis in Automatika
- Vol. 54 (2) , 188-198
Improved Algorithms of Direct Torque Control Method
In the paper a new way of DTC control method analysis to explain flux and current distortion at a low speed of motor operation is discussed. As a result, a new DTC-d algorithm is proposed. It is important that the DTC-d algorithm uses the same switching table as the DTC method. The modified DTC algorithms are free from the disadvantages of the conventional DTC method i.e. hexagonal flux and strongly deformed current at a low speed range. The dynamical properties of the new algorithms are similar to the conventional DTC method. The correctness of the proposed methods has been confirmed by laboratory investigations.
- 20 January 2013
- Published by Taylor & Francis in Automatika
- Vol. 54 (2) , 188-198
Open AccessImproved Algorithms of Direct Torque Control Method
In the paper a new way of DTC control method analysis to explain flux and current distortion at a low speed of motor operation is discussed. As a result, a new DTC-d algorithm is proposed. It is important that the DTC-d algorithm uses the same switching table as the DTC method. The modified DTC algorithms are free from the disadvantages of the conventional DTC method i.e. hexagonal flux and strongly deformed current at a low speed range. The dynamical properties of the new algorithms are similar to the conventional DTC method. The correctness of the proposed methods has been confirmed by laboratory investigations.
- Open Access
- 1 December 2011
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 59 (4) , 507-511
AC/DC/AC converter in a small hydroelectric power plant
AC/DC/AC converter in a small hydroelectric power plant: The article discusses application of AC/DC/AC converter cooperating with an induction generator in small hydroelectric power plants. The induction generator works with power grid or a separated group of receivers, enabling to generate power even at low speeds of the turbine. The article provides also results of the investigation concerning the functioning of the generator coupled with AC/DC/AC converter in steady and transient states during start-up and voltage decay.
- 1 December 2011
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 59 (4) , 507-511
Open AccessAC/DC/AC converter in a small hydroelectric power plant
AC/DC/AC converter in a small hydroelectric power plant: The article discusses application of AC/DC/AC converter cooperating with an induction generator in small hydroelectric power plants. The induction generator works with power grid or a separated group of receivers, enabling to generate power even at low speeds of the turbine. The article provides also results of the investigation concerning the functioning of the generator coupled with AC/DC/AC converter in steady and transient states during start-up and voltage decay.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1733-1739
A comparison of properties of direct torque and flux control methods (DTC-SVM,DTC-δ, DTC-2x2, DTFC-3A)
In the paper comparison of two classes of direct torque and flux control methods with linear (DTC-SVM) and nonlinear (DTC-δ, DTC-2x2, DTFC-3A) controllers was carried out. Criteria of comparisons in both steady and transient states in similar conditions i.e. at the same average switching frequency, were proposed. The comparisons were made using the results of laboratory tests of control systems cooperating with drive systems.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1733-1739
A comparison of properties of direct torque and flux control methods (DTC-SVM,DTC-δ, DTC-2x2, DTFC-3A)
In the paper comparison of two classes of direct torque and flux control methods with linear (DTC-SVM) and nonlinear (DTC-δ, DTC-2x2, DTFC-3A) controllers was carried out. Criteria of comparisons in both steady and transient states in similar conditions i.e. at the same average switching frequency, were proposed. The comparisons were made using the results of laboratory tests of control systems cooperating with drive systems.
- 14 August 2007
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 26 (4) , 1204-1217
Improved direct torque and flux control of induction motor drive
Purpose – The aim of the paper is to conduct an analytical study of a new method of induction motor torque and flux direct control with nonlinear controllers. Design/methodology/approach – The method is based on the inverter state predictive determination in order to minimize the torque and flux errors. Findings – The proposed method allows one to eliminate known DTC disadvantages, i.e. the hexagonal flux shape and nonsinusoidal current at a low motor speed, and also secures a decrease of torque and flux pulsation. Practical implications – This new method enables a more precise reproduction of the motor torque and flux command signals, working with the same sampling frequency of the control processor as in the case of the standard DTC method. The decreased torque pulsations cause a decrease of the motor speed pulsation. Originality/value – An innovative optimal control method is presented. The correctness of the initial assumptions as well as the expected final results have been verified in practice.
- 14 August 2007
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 26 (4) , 1204-1217
Improved direct torque and flux control of induction motor drive
Purpose – The aim of the paper is to conduct an analytical study of a new method of induction motor torque and flux direct control with nonlinear controllers. Design/methodology/approach – The method is based on the inverter state predictive determination in order to minimize the torque and flux errors. Findings – The proposed method allows one to eliminate known DTC disadvantages, i.e. the hexagonal flux shape and nonsinusoidal current at a low motor speed, and also secures a decrease of torque and flux pulsation. Practical implications – This new method enables a more precise reproduction of the motor torque and flux command signals, working with the same sampling frequency of the control processor as in the case of the standard DTC method. The decreased torque pulsations cause a decrease of the motor speed pulsation. Originality/value – An innovative optimal control method is presented. The correctness of the initial assumptions as well as the expected final results have been verified in practice.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 137, 1896-1901
Identification of Dead-Time Influence on The Output Voltage of the Inverter Controlled by Non-Linear Controllers
The influence of the dead-time on a inverter VSI output voltage vector controlled by SVM where the switching sequence is defined, is well known. Towards of the inverters used nonlinear controllers, where the sequence of the succeeding voltage vectors maybe of one's choice, the dead-time influence evaluation is different. The method evaluation of dead-time influence on the output voltage of the inverter controlled by nonlinear controllers is presented in the article. The laboratory test results confirm correctness of this analysis and elaborated correction algorithm.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 137, 1896-1901
Identification of Dead-Time Influence on The Output Voltage of the Inverter Controlled by Non-Linear Controllers
The influence of the dead-time on a inverter VSI output voltage vector controlled by SVM where the switching sequence is defined, is well known. Towards of the inverters used nonlinear controllers, where the sequence of the succeeding voltage vectors maybe of one's choice, the dead-time influence evaluation is different. The method evaluation of dead-time influence on the output voltage of the inverter controlled by nonlinear controllers is presented in the article. The laboratory test results confirm correctness of this analysis and elaborated correction algorithm.