Andrzej Sikorski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Andrzej Sikorski has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Marek Korzeniewski
Bialystok Technical University, Dep. of Power Electronics and Electrical Drives, Bialystok, Poland
8 shared publications - Krzysztof Kulikowski
Department of Electrotechnics, Power Electronics and Electrical Power Engineering, Biaystok University of Technology, Biaystok, Poland
6 shared publications - Piotr Falkowski
Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland
5 shared publications - Agata Godlewska
Department of Power Electronics and Electric Drives, Bialystok University of Technology, Biaystok, Poland
3 shared publications - Krzysztof Dmitruk
Faculty of Electrical Engineering, Bialystok University of Technology, Wiejska 45D, 15-351 Bialystok, Poland
3 shared publications - Adam Ruszczyk
Bialystok Technical University, Dep. of Power Electronics and Electrical Drives, Bialystok, Poland
2 shared publications
Latest Publications
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12095-12111
A Novel Continuous Control Set Current-Based Model Predictive Control for a Three-Phase, Two-Level AC/DC Converter With the LCL Filter
This article presents a developed novel continuous control set current-based model predictive control (CCS C-BMPC) for an ac–dc grid converter connected to the grid through an LCL filter. Most CCS MPC algorithms control the converter current by regulating the reference voltage derived from the prediction algorithm in the final control stage. The proposed algorithm enables direct control of the grid current by regulating the converter current and the voltage on the filter capacitor. The algorithm uses optimized prediction to compensate for the grid current vector error, minimizing total harmonic distortion (THD) at a relatively low switching frequency. It exhibits high robustness to power grid disturbances and avoids current distortions during zero crossing, especially at low current amplitudes. The advantages of the proposed method have been confirmed in simulations and laboratory tests in steady-state and transient conditions. It confirms that the developed control technique shows a high quality of the grid current (low THDi value), high dynamic performance, and immunity in case of weak grid conditions. The proposed method was compared with a method that uses a typical proportional-resonant current controller.
- 23 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12095-12111
A Novel Continuous Control Set Current-Based Model Predictive Control for a Three-Phase, Two-Level AC/DC Converter With the LCL Filter
This article presents a developed novel continuous control set current-based model predictive control (CCS C-BMPC) for an ac–dc grid converter connected to the grid through an LCL filter. Most CCS MPC algorithms control the converter current by regulating the reference voltage derived from the prediction algorithm in the final control stage. The proposed algorithm enables direct control of the grid current by regulating the converter current and the voltage on the filter capacitor. The algorithm uses optimized prediction to compensate for the grid current vector error, minimizing total harmonic distortion (THD) at a relatively low switching frequency. It exhibits high robustness to power grid disturbances and avoids current distortions during zero crossing, especially at low current amplitudes. The advantages of the proposed method have been confirmed in simulations and laboratory tests in steady-state and transient conditions. It confirms that the developed control technique shows a high quality of the grid current (low THDi value), high dynamic performance, and immunity in case of weak grid conditions. The proposed method was compared with a method that uses a typical proportional-resonant current controller.
- 14 May 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (5) , 84-87
Emisja przewodzona na porcie wejściowym naziemnej jednostki zasilającej statki powietrzne w standardzie 28 V DC oraz 270 V DC
W artykule przedstawiono badania konstruktorskie emisji przewodzonej zasilacza statków powietrznych zbudowanego z przekształtników energoelektronicznych AC/DC oraz DC/AC/DC z separacją transformatorową. Badana wersja zasilacza może być zasilana z dwóch standardów napięcia 400 V / 50 Hz albo 480 V / 60 Hz. Zasilacz na wyjściu wytwarza separowane napięcie 28 V DC oraz 270 V DC. Badania emisji przewodzonej wykonano na porcie zasilającym dla napięcia 400 V / 50 Hz w oparciu o procedurę CE102 normy MIL-STD-461G.
- 14 May 2024
- Published by Wydawnictwo SIGMA-NOT, sp. z.o.o. in PRZEGLĄD ELEKTROTECHNICZNY
- Vol. 1 (5) , 84-87
Emisja przewodzona na porcie wejściowym naziemnej jednostki zasilającej statki powietrzne w standardzie 28 V DC oraz 270 V DC
W artykule przedstawiono badania konstruktorskie emisji przewodzonej zasilacza statków powietrznych zbudowanego z przekształtników energoelektronicznych AC/DC oraz DC/AC/DC z separacją transformatorową. Badana wersja zasilacza może być zasilana z dwóch standardów napięcia 400 V / 50 Hz albo 480 V / 60 Hz. Zasilacz na wyjściu wytwarza separowane napięcie 28 V DC oraz 270 V DC. Badania emisji przewodzonej wykonano na porcie zasilającym dla napięcia 400 V / 50 Hz w oparciu o procedurę CE102 normy MIL-STD-461G.
- Open Access
Implementation of the Improved Active Frequency Drift Anti-Islanding Method into the Three-Phase AC/DC Converter with the LCL Grid Filter
The article presents a modified standard Active Frequency Drift (AFD) method used to detect unintentional island operation in converters generating electricity from renewable energy sources to the power grid. The primary aim of each of the island operation detection methods is the possibility of shortening the energising of a separate part of the power grid. The proposed method eliminates fragments of the reference current signal when it reaches a constant value for a particular time. This part of the signal is replaced with the hyperbolic sine function. It allows reducing the value of Total Harmonic Distortions (THD) while maintaining the same effectiveness of island operation detection. The article contains a detailed description of the newly proposed type of disturbance generation. The proposed solution is verified by conducting simulation and laboratory tests. The possibility of shortening the island operation detection time is proven by increasing the maximum distortion introduced into the current without exceeding the permissible THD limit for converters connected to the power grid.
Open AccessImplementation of the Improved Active Frequency Drift Anti-Islanding Method into the Three-Phase AC/DC Converter with the LCL Grid Filter
The article presents a modified standard Active Frequency Drift (AFD) method used to detect unintentional island operation in converters generating electricity from renewable energy sources to the power grid. The primary aim of each of the island operation detection methods is the possibility of shortening the energising of a separate part of the power grid. The proposed method eliminates fragments of the reference current signal when it reaches a constant value for a particular time. This part of the signal is replaced with the hyperbolic sine function. It allows reducing the value of Total Harmonic Distortions (THD) while maintaining the same effectiveness of island operation detection. The article contains a detailed description of the newly proposed type of disturbance generation. The proposed solution is verified by conducting simulation and laboratory tests. The possibility of shortening the island operation detection time is proven by increasing the maximum distortion introduced into the current without exceeding the permissible THD limit for converters connected to the power grid.
- Open Access
Comparison of Two Power Converter Topologies in Wind Turbine System
The article presents comprehensive results of research on two representative topologies of converters used in the path of processing energy generated in a wind turbine and transmitted to the grid. The topology T1 uses a two-level transistor-controlled rectifier as a converter from the generator side, while the T2 topology uses DC/DC boost converter. In both topologies, a three-level back-to-back converter with a line filter L was used as a grid converter. The conclusions indicate the tendency of changes in power losses depending on the aforementioned parameters and can be used at the stage of deciding on the choice of topology, operating parameters or selection of control methods depending on the specific operating conditions of the wind turbine.
Open AccessComparison of Two Power Converter Topologies in Wind Turbine System
The article presents comprehensive results of research on two representative topologies of converters used in the path of processing energy generated in a wind turbine and transmitted to the grid. The topology T1 uses a two-level transistor-controlled rectifier as a converter from the generator side, while the T2 topology uses DC/DC boost converter. In both topologies, a three-level back-to-back converter with a line filter L was used as a grid converter. The conclusions indicate the tendency of changes in power losses depending on the aforementioned parameters and can be used at the stage of deciding on the choice of topology, operating parameters or selection of control methods depending on the specific operating conditions of the wind turbine.
- 19 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (10) , 11875-11885
Finite Control Set Model Predictive Control With Floating Virtual Voltage Vectors for Grid-Connected Voltage Source Converter
This paper presents a new algorithm of finite control set model predictive control (FCS-MPC) with floating virtual voltage vectors (VVs) applied to grid-connected voltage source converter. The new solution improves the conventional FCS-MPC and FCS-MPC with virtual VVs, assuring a fixed switching frequency. In comparison with FCS-MPC using virtual VVs, the proposed algorithm ensures a shorter distance between floating virtual VVs and actual voltage vector achieves lower THDi and ripples of the grid current for the same sampling time. The proposed control method has been experimentally validated using a 5 kW prototype. The algorithm was examined and compared in steady and transient states as well as under grid voltage disturbances, such as higher harmonics, dips, unbalance. The simulation results and experimental measurements confirm that the developed control technique shows a high quality of the grid current (low THDi value), high dynamic performance and immunity in case of weak grid conditions.
- 19 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (10) , 11875-11885
Finite Control Set Model Predictive Control With Floating Virtual Voltage Vectors for Grid-Connected Voltage Source Converter
This paper presents a new algorithm of finite control set model predictive control (FCS-MPC) with floating virtual voltage vectors (VVs) applied to grid-connected voltage source converter. The new solution improves the conventional FCS-MPC and FCS-MPC with virtual VVs, assuring a fixed switching frequency. In comparison with FCS-MPC using virtual VVs, the proposed algorithm ensures a shorter distance between floating virtual VVs and actual voltage vector achieves lower THDi and ripples of the grid current for the same sampling time. The proposed control method has been experimentally validated using a 5 kW prototype. The algorithm was examined and compared in steady and transient states as well as under grid voltage disturbances, such as higher harmonics, dips, unbalance. The simulation results and experimental measurements confirm that the developed control technique shows a high quality of the grid current (low THDi value), high dynamic performance and immunity in case of weak grid conditions.
- Open Access
- 31 October 2020
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 68 (5) , 959-962
Adaptive, predictive and neural approaches in drive automation and control of power converters
- 31 October 2020
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 68 (5) , 959-962
Open AccessAdaptive, predictive and neural approaches in drive automation and control of power converters
- Top Cited Papers
- 8 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 65 (4) , 2844-2852
Finite Control Set Model Predictive Control for Grid-Connected AC–DC Converters With LCL Filter
This paper presents two new implementations of finite control set model predictive control (FCS-MPC) methods applied to ac-dc converters with an inductive.capacitive.inductive (LCL) filter. The LCL filter, despite its advantages, can cause a strong resonance in the grid current and also pose a substantially more complex control problem. The new solutions improve the FCS-MPC with an active damping algorithm by eliminating low-order grid current harmonics and decreasing sensitivity to grid voltage distortion. The new methods, i.e., PCi1i2uc and PCi1i2uc-2steps propose multivariable approaches using converter-side current, line-side current, and capacitor voltage. Another improvement involves extending the prediction horizon in PCi1 i2uc-2steps. Both methods have been tested and compared in steady and transient states as well as under grid voltage disturbances. The methods were also compared with a predictive control algorithm with active damping. The simulation results and experimental measurements validate the developed control schemes and show high quality of grid current (low THDi value), high dynamic performance, and immunity under distorted grid voltage conditions.
- 8 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 65 (4) , 2844-2852
Top Cited PapersFinite Control Set Model Predictive Control for Grid-Connected AC–DC Converters With LCL Filter
This paper presents two new implementations of finite control set model predictive control (FCS-MPC) methods applied to ac-dc converters with an inductive.capacitive.inductive (LCL) filter. The LCL filter, despite its advantages, can cause a strong resonance in the grid current and also pose a substantially more complex control problem. The new solutions improve the FCS-MPC with an active damping algorithm by eliminating low-order grid current harmonics and decreasing sensitivity to grid voltage distortion. The new methods, i.e., PCi1i2uc and PCi1i2uc-2steps propose multivariable approaches using converter-side current, line-side current, and capacitor voltage. Another improvement involves extending the prediction horizon in PCi1 i2uc-2steps. Both methods have been tested and compared in steady and transient states as well as under grid voltage disturbances. The methods were also compared with a predictive control algorithm with active damping. The simulation results and experimental measurements validate the developed control schemes and show high quality of grid current (low THDi value), high dynamic performance, and immunity under distorted grid voltage conditions.
- 29 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Predictive current control of back-to-back converter
Three-phase current source rectifier (CSR) is becoming more popular in industry as front-end converter because its four-quadrant work and low electromagnetic interferences. However, it includes LC filter on the input side, which lowers efficiency and enhances distortions of grid currents. Impact of those disadvantages can be reduced by proper control algorithm. The purpose of this paper is to present a new predictive control strategy of the CSR providing low grid currents distortions and unity power factor. The algorithm chooses proper space vector of the rectifier according to the predicted value of the DC current and predicted value of the capacitor voltage. Proposed method is analysed for different reference values. Simulation results confirm good performance of the system, distortions are reduced and unity power factor is obtained. The method is useful in many applications, including low voltage DC loads feeding and active power filtering.
- 29 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Predictive current control of back-to-back converter
Three-phase current source rectifier (CSR) is becoming more popular in industry as front-end converter because its four-quadrant work and low electromagnetic interferences. However, it includes LC filter on the input side, which lowers efficiency and enhances distortions of grid currents. Impact of those disadvantages can be reduced by proper control algorithm. The purpose of this paper is to present a new predictive control strategy of the CSR providing low grid currents distortions and unity power factor. The algorithm chooses proper space vector of the rectifier according to the predicted value of the DC current and predicted value of the capacitor voltage. Proposed method is analysed for different reference values. Simulation results confirm good performance of the system, distortions are reduced and unity power factor is obtained. The method is useful in many applications, including low voltage DC loads feeding and active power filtering.
- 1 October 2016
- Published by Springer Nature
- p. 221-302
Advanced Control Methods of DC/AC and AC/DC Power Converters—Look-Up Table and Predictive Algorithms
- 1 October 2016
- Published by Springer Nature
- p. 221-302
Advanced Control Methods of DC/AC and AC/DC Power Converters—Look-Up Table and Predictive Algorithms
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Dead-time compensation in a new FCS-MPC of an AC/DC converter with a LCL filter
The article presents Finite Control Set Model Predictive Control for an AC/DC converter with a LCL filter. The extended cost function J is responsible for the adjustment of controlled values. An important issue raised in the article is the impact of dead time on the prediction of controlled values. The negative impact of dead time results in an increased THD of the grid current. The article proposes an algorithm correcting the impact of dead time which was confirmed by the results of Matlab-Simulink simulations and laboratory tests.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Dead-time compensation in a new FCS-MPC of an AC/DC converter with a LCL filter
The article presents Finite Control Set Model Predictive Control for an AC/DC converter with a LCL filter. The extended cost function J is responsible for the adjustment of controlled values. An important issue raised in the article is the impact of dead time on the prediction of controlled values. The negative impact of dead time results in an increased THD of the grid current. The article proposes an algorithm correcting the impact of dead time which was confirmed by the results of Matlab-Simulink simulations and laboratory tests.