Frank A. Moreno Vera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Frank A. Moreno Vera has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Damian Sal Y Rosas
LAAS-CNRS, University of Toulouse, Toulouse, France
2 shared publications - Gustavo Pérez-Zuñiga
Pontificia Universidad Católica del Perú
2 shared publications - Javier Sotomayor-Moriano
Departamento de Ingeniería, Pontificia Universidad Católica del Perú (PUCP), Avenida Universitaria 1801, San Miguel, Lima 15088, Peru
2 shared publications - Jhonatan D. Paucara
Universidad Tecnolgica del Per, Lima, Peru
2 shared publications
Latest Publications
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A grid-tied power factor corrector microinverter without electrolytic capacitor by the control of voltage in a DC-link for a non-linear load
A novel control strategy is proposed for a bidirectional multiport single phase two stage microinverter without electrolytic capacitor. The application of this converter is for power factor correction under non-linear grid tied load. The converter is composed of a triple active bridge series-resonant DC/DC converter cascaded with a voltage source inverter where a film capacitor is used in the DC-Link. Power decoupling is obtained due to a high ripple low frequency voltage in the DC-Link. The proposed controller has three cascaded loops to control the DC-Link average voltage, the instantaneous grid current and the point of common coupling voltage respectively. This strategy allows having a high speed steady-state response, good stability, low harmonic distortion in the grid, bidirectional power flow and low computational cost unlike other controllers. Two different cases have been tested, the first one when only the grid delivers power to the non-linear load, and the second one when the power flow is shared between the grid and any other DC source (renewable source or battery). Simulation results validate the controller functionality.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A grid-tied power factor corrector microinverter without electrolytic capacitor by the control of voltage in a DC-link for a non-linear load
A novel control strategy is proposed for a bidirectional multiport single phase two stage microinverter without electrolytic capacitor. The application of this converter is for power factor correction under non-linear grid tied load. The converter is composed of a triple active bridge series-resonant DC/DC converter cascaded with a voltage source inverter where a film capacitor is used in the DC-Link. Power decoupling is obtained due to a high ripple low frequency voltage in the DC-Link. The proposed controller has three cascaded loops to control the DC-Link average voltage, the instantaneous grid current and the point of common coupling voltage respectively. This strategy allows having a high speed steady-state response, good stability, low harmonic distortion in the grid, bidirectional power flow and low computational cost unlike other controllers. Two different cases have been tested, the first one when only the grid delivers power to the non-linear load, and the second one when the power flow is shared between the grid and any other DC source (renewable source or battery). Simulation results validate the controller functionality.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 1-6
Bidirectional multiport microinverter and grid-multimode-operation control for a non-linear load
Micro-inverters usually are used to connect photovoltaic panels (PV) to the electricity grid. If the energy provided by the panel is not enough to satisfy the demands, the system becomes dependent exclusively of the grid. This constraint demands the use of a battery bank, therefore it is necessary to add a third port to the micro-inverter to connect this energy backup. In this paper, a two stage micro-inverter is proposed, the first stage is a DC/DC Triple Active Bridge (TAB) converter that integrates a back-up battery and works in soft switching; and the second stage is a Voltage Source Inverter (VSl) that operates in both grid-connected mode (GCM) and Stand Alone Mode (SAM). The grid-multimode operation controller developed detects the islanding fault and maintains the energy quality for a typical nonlinear load. Reliability and robustness of Uninterrupted Power Supplies (UPS) are increased by the proposed control.
- 1 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 5, 1-6
Bidirectional multiport microinverter and grid-multimode-operation control for a non-linear load
Micro-inverters usually are used to connect photovoltaic panels (PV) to the electricity grid. If the energy provided by the panel is not enough to satisfy the demands, the system becomes dependent exclusively of the grid. This constraint demands the use of a battery bank, therefore it is necessary to add a third port to the micro-inverter to connect this energy backup. In this paper, a two stage micro-inverter is proposed, the first stage is a DC/DC Triple Active Bridge (TAB) converter that integrates a back-up battery and works in soft switching; and the second stage is a Voltage Source Inverter (VSl) that operates in both grid-connected mode (GCM) and Stand Alone Mode (SAM). The grid-multimode operation controller developed detects the islanding fault and maintains the energy quality for a typical nonlinear load. Reliability and robustness of Uninterrupted Power Supplies (UPS) are increased by the proposed control.