THTao He

Tao He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tao He has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Halogen behavior during high-grade metamorphism and partial melting in the deep continental crust (Ivrea-Verbano Zone, NW Italy)

    by Peng-Yuan Han, Madison S. Huising, Jaime D. Barnes, Michael A.W. Marks, Tao He, Fernando Bea, Zhao-Chu Hu, Roberta L. Rudnick

  • Chalcophile elements in post-subduction magmas and implications for metal recycling in oceanic and continental subduction

    by Xiang Wang, Zaicong Wang, Li-Qun Dai, Wen Zhang, Xiaodong Deng, Xi Zhang, Stephen Foley, Charles H. Langmuir, Wei Fang, Lang Wang, et al.


  • A novel (NH 4 ) 2 HPO 4 –LiBO 2 fusion technique for bulk silicate rock analysis by laser ablation-inductively coupled plasma-mass spectrometry

    by Xiaoyun Qiu, Zhaochu Hu, Tao Luo, Tao He, Wen Zhang, Ming Li, Zhenli Zhu, Lijin Huang, Mingxing Gong

    A novel and rapid (NH 4 ) 2 HPO 4 –LiBO 2 fusion technique using a homemade fusion furnace and graphite crucibles was established for bulk silicate rock analysis by LA-ICP-MS.

  • Open Access

    A two-step chromatographic purification method for Ni for its isotopic analysis by MC-ICP-MS

    by Lingke Li, Fei Wu, Yongsheng Liu, Tao He, Jie Lin, Wen Zhang, Rui Li, Haihong Chen, Keqing Zong, Zhen Zeng, et al.

    Stable nickel (Ni) isotope has shown great potential for investigating planetary accretion processes, mantle-crust magmatism, and paleo-marine evolution. The development of an economical and time-efficient separation method for Ni isotope analysis holds significant value within the realm of Ni isotope research. Previous purification methods for Ni isotope analysis have typically relied on either multi-column procedures or the utilization of significant quantities of organic reagents, such as acetic acid, acetone, dimethylglyoxime. In this study, a novel two-column chromatographic separation procedure was presented for the determining Ni isotope compositions in geological materials. The cation resin (AG50W-X8) was utilized in conjunction with diluted HCl and HF to effectively remove a substantial portion of matrix elements. Subsequently, trace amounts (100–200 μL) of Ni-spec resin were used for further purification of Ni. This relatively simple purification scheme for Ni isotope analysis effectively reduces the introduction of organic regents and the amount of Ni-spec resin compared to previous methods relied on multiple-column separation and organic reagent extraction. Ni isotopic compositions were analyzed using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The instrumental mass fractionation of Ni isotopic ratios was corrected using the double spike (DS) combined with the sample-standard-bracketing method (SSB). The Ni isotope compositions (δ60Ni) of in-house standards (SCP and CUG) were -0.06 ± 0.05‰ (2 SD, n=104) and 0.36 ± 0.06‰ (2 SD, n=97), respectively. Furthermore, the measured δ60Ni values of various geological reference materials (BCR-2, BHVO-2, BIR-1, DTS-1, DTS-2b, SDO-1, GSP-2, W-2a from the USGS, JB-1b from the GSJ, GSR-2, GSR-3, GSR-4, GSR-5, GSR-10 from the NRCGA) were consistent with previous studies within measurement error. Additionally, the δ60Ni values of AGV-1 from the USGS, as well as GSR-10, GSR-12, GSR-15, GSR-17, GSR-18, GSR-19 from the NRCGA are reported here for the first time. Based on repeated measurements of pure solutions and reference materials, the long-term reproducibility of δ60Ni values was better than ± 0.06‰ (2 SD). Consequently, our study presents a relatively straightforward purification method of Ni for its isotopic analysis using only trace amounts of organic regents and Ni-spec resin.


  • Determination of major and trace elements in silicate rock fused with lithium metaborate using laser ablation-inductively coupled plasma-mass spectrometry

    by Xiaoyun Qiu, Zhaochu Hu, Tao He, Tao Luo, Wen Zhang, Ming Li, Keqing Zong, Zaicong Wang, Yongsheng Liu

    In this study, a novel lithium metaborate fusion technique using a homemade fusion furnace and graphite crucibles was developed to produce homogeneous glasses from silicate rock powder. The glasses were then analyzed for both major and trace element concentrations by LA-ICP-MS. The parameters of the ratio of flux-to-sample, melting temperature and time, and closed fusion were optimized. It was found that homogeneous glasses could be obtained, and the loss of Pb was effectively suppressed at a low melting temperature and short time (900 or 950 °C for 5 min) in closed fusion. Compared to Pt or Pt–Au crucibles in the traditional flux fusion method, homemade graphite crucibles are more economical and omit the need of any releasing agent because the bottom curve design allows the melt to shrink into a bead for easy removal. Accurate results by LA-ICP-MS can be directly obtained by applying a quantitative calibration strategy using 100% oxide normalization, which offers a solution for unknown sample analysis without the prior determination of the concentration of an internal standard element. The analytical results of 42 major and trace elements in 5 USGS silicate rock reference materials (covering mafic to felsic rock types) using the developed LiBO2 fusion technique are consistent with the reference values within 10% for most elements, and analytical precision (RSD) is within 10% for most elements. The developed method is simple for preparing homogeneous glasses from rock powders, which displays great potential for the rapid and accurate determination of mass fractions of major and trace elements in silicate rocks using LA-ICP-MS.


  • Evaluation of the digestion capability of ammonium bifluoride for the determination of major and trace elements in Ti-rich minerals by ICP-MS

    by Hong Liu, Zhaochu Hu, Tao He, Wen Zhang, Keqing Zong, Tao Luo, Xiaoyun Qiu, Yang Gao, Mufei Li

    Complete sample digestion is a prerequisite to achieve accurate and precise results of elemental concentrations and isotopic compositions in Ti-rich minerals of interest, such as refractory rutile. In this study, a rapid digestion protocol using ammonium bifluoride (NH4HF2) was developed to completely digest large amounts of rutile, ilmenite, titanite and perovskite. These Ti-rich samples (50 mg) can be completely digested in 4 hours with the use of 300 mg of NH4HF2 at 230 °C, and each 200 mg of rutile and ilmenite ore can be completely dissolved with NH4HF2 digestion and without insoluble residues present. Furthermore, NH4HF2 digestion was found to be effective in dissolving the different sizes (31–150 μm) of Ti-rich minerals. Compared to common HNO3–HF closed-vessel acid digestion, the proposed NH4HF2 digestion provides consistent results for major Ti and thirty-six other trace elements in a series of ilmenite ore reference materials and in-house Ti-rich minerals. It was found that elemental concentrations (Ti, Sc, V, Cr, Nb, Ta, Hf and U) in rutile measured by inductively coupled plasma-mass spectrometry (ICP-MS) using NH4HF2 digestion were consistent with the values measured in the pressed powder pellet of rutile by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). However, lower recoveries of Ti, V, Nb and Ta in rutile were obtained from closed-vessel acid digestion, possibly due to the formation of white precipitates during the evaporation/redissolution process. The proposed NH4HF2 digestion is safe and more effective in quickly dissolving Ti-rich materials and suitable for the determination of quantities of major and trace elements.


  • Design and Implementation of Reading System Based on Improved Personalized Recommendation Hybrid Algorithm

    by Zhou Chunrong, He Tao, Xiao Xianglin

    In the paper, a personalized recommendation precision reading system based on an improved personalized recommendation hybrid algorithm is developed. The server side develops and selects the mature lightweight framework Spring Boot, and the client side develops and uses Html5 and Apache Cordova framework to meet the needs of mobile terminal devices of different operating systems. The results show that the improved algorithm can improve the accuracy and stability of reading recommendation.


  • An Improved Procedure for the Determination of Trace Elements in Silicate Rocks Using NH4HF2 Digestion

    by Chen Zhang, Wen Zhang, Zhaochu Hu, Tao He, Yongsheng Liu, Haihong Chen

    Knowledge of the elemental composition of geological samples is of high significance to research in Earth science. For whole‐rock elemental determination, complete sample digestion is essential to obtain bias‐free measurement results. In recent years, NH4HF2 digestion has been proposed for geological sample dissolution; however, this requires 3 h of sample evaporation and 6 h of re‐dissolution of residues. In this study a PTFE beaker, which can withstand 300 °C, was designed to increase the evaporation temperature, reducing the evaporation time to 15 min. Further investigations found that the insoluble fluoride residues formed during the high‐temperature evaporation stage significantly influenced the recoveries of Sc, Y, rare earth elements and Th. Among the tested strategies to suppress the formation of fluorides, the microwave heating method was the most efficient and robust. The optimised NH4HF2 digestion shortened the sample evaporation and re‐dissolution times from 9 h to 21 min, significantly reducing the time consumed for sample evaporation by a factor of ~ 26. A suite of silicate rock reference materials was analysed. The results for most elements were in agreement with reference values with a measurement bias of < 10%.


  • A high-performance method for direct determination of ultra-trace REEs in geological samples by ICP-MS using a designed heating-condensing system

    by Jiaxin Yu, He Zhao, Tao He, Tao Luo, Wen Zhang, Keqing Zong, Jie Lin, Yongsheng Liu, Zhaochu Hu

    High sensitivity and minimized spectral interference are prerequisites for precise and accurate measurement results of ultra-trace REEs (Sc and Y, rare earth elements) in geological samples (e.g., carbonates and peridotites). In this study, we designed a heating-condensing system for the direct determination of mass fractions of ultra-trace REEs in carbonates and peridotites by Ar–N2 mixed plasma ICP-MS combined with different skimmer cones. Compared to those under normal conditions (without a heating-condensing system), the signal sensitivities of the investigated 47 elements were improved by 5–8 and 6–24 fold at a heating temperature of 180 °C when using the H skimmer cone and the X skimmer cone, respectively. Our results firstly indicate that the geometry of the skimmer cone has an important effect on signal enhancement when using the heating-condensing system in ICP-MS. The addition of nitrogen (3–9 ml min−1) in the central channel of the plasma was found to significantly reduce the oxide ratios (CeO+/Ce+) by a factor of approximately 5–10. This reduction is important for the determination of ultra-trace REEs, which are well known to be interfered by oxides of Ba and light REEs. We successfully applied this method to directly determine ultra-trace REEs in eight reference carbonates and peridotites. This simple and rapid method shows great potential for the direct determination of ultra-trace REEs in geological samples and other technogenic materials with a high matrix and low REE abundances.


  • How mafic was the Archean upper continental crust? Insights from Cu and Ag in ancient glacial diamictites

    by Kang Chen, Roberta L. Rudnick, Zaicong Wang, Ming Tang, Richard M. Gaschnig, Zongqi Zou, Tao He, Zhaochu Hu, Yongsheng Liu