SongShou Mao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
SongShou Mao has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Jay Budoff
Lundquist Institute at Harbor-UCLA Medical Center, Torrance, California, USA
4 shared publications - April Kinninger
The Lundquist Institute for Biomedical Innovation at Harbor UCLA Medical Center, 1124 W Carson St, Torrance, CA 90502, USA
2 shared publications - Alfred P. Yoon
Division of Plastic and Reconstructive Surgery, Section of Hand and Microvascular Surgery, University of California Davis Medical Center, Sacramento, CA, United States
1 shared publication - Anna E. Bortnick
Montefiore Medical Center and Albert Einstein College of Medicine
1 shared publication - Beshoy Iskander
The Lundquist Institute for Biomedical Innovation at Harbor UCLA Medical Center, 1124 W Carson St, Torrance, CA 90502, USA
1 shared publication Bin Lu
1 shared publication
Latest Publications
- 3 January 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 20 (4) , 446-447
Ethnic differences in left ventricular myocardial volume assessed by coronary computed tomography angiography in asymptomatic adults
- 3 January 2026
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 20 (4) , 446-447
Ethnic differences in left ventricular myocardial volume assessed by coronary computed tomography angiography in asymptomatic adults
- 3 August 2023
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 48 (1) , 49-54
Methods and Reproducibility of Liver Fat Measurement Using 3-Dimensional Liver Segmentation From Noncontrast Computed Tomography in EVAPORATE Cohort
Objective Nonalcoholic fatty liver disease not only shares multiple risk factors with cardiovascular disease but also independently predicts its increased risk and related outcomes. Here, we evaluate reproducibility of 3-dimensional (3D) liver volume segmentation method to identify fatty liver on noncontrast cardiac computed tomography (CT) and compare measures with previously validated 2-dimensional (2D) segmentation CT criteria for the measurement of liver fat. Methods The study included 68 participants enrolled in the EVAPORATE trial and underwent serial noncontrast cardiac CT. Liver attenuation < 40 Hounsfield units (HU) was used for diagnosing fatty liver, as done in the MESA study. Two-dimensional and 3D segmentation of the liver were performed by Philips software. Bland-Altman plot analysis was used to assess reproducibility. Results Interreader reproducibility of 3D liver mean HU measurements was 96% in a sample of 111 scans. Reproducibility of 2D and 3D liver mean HU measurements was 93% in a sample of 111 scans. Reproducibility of change in 2D and 3D liver mean HU was 94% in 68 scans. Kappa, a measure of agreement in which the 2D and 3D measures both identified fatty liver, was excellent at 96.4% in 111 scans. Conclusions Fatty liver can be reliably diagnosed and measured serially in a stable and reproducible way by 3D liver segmentation of noncontrast cardiac CT scans. Future studies need to explore the sensitivity and stability of measures for low liver fat content by 3D segmentation, over the current 2D methodology. This measure can serve as an imaging biomarker to understand mechanistic correlations between atherosclerosis, fatty liver, and cardiovascular disease risk.
- 3 August 2023
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 48 (1) , 49-54
Methods and Reproducibility of Liver Fat Measurement Using 3-Dimensional Liver Segmentation From Noncontrast Computed Tomography in EVAPORATE Cohort
Objective Nonalcoholic fatty liver disease not only shares multiple risk factors with cardiovascular disease but also independently predicts its increased risk and related outcomes. Here, we evaluate reproducibility of 3-dimensional (3D) liver volume segmentation method to identify fatty liver on noncontrast cardiac computed tomography (CT) and compare measures with previously validated 2-dimensional (2D) segmentation CT criteria for the measurement of liver fat. Methods The study included 68 participants enrolled in the EVAPORATE trial and underwent serial noncontrast cardiac CT. Liver attenuation < 40 Hounsfield units (HU) was used for diagnosing fatty liver, as done in the MESA study. Two-dimensional and 3D segmentation of the liver were performed by Philips software. Bland-Altman plot analysis was used to assess reproducibility. Results Interreader reproducibility of 3D liver mean HU measurements was 96% in a sample of 111 scans. Reproducibility of 2D and 3D liver mean HU measurements was 93% in a sample of 111 scans. Reproducibility of change in 2D and 3D liver mean HU was 94% in 68 scans. Kappa, a measure of agreement in which the 2D and 3D measures both identified fatty liver, was excellent at 96.4% in 111 scans. Conclusions Fatty liver can be reliably diagnosed and measured serially in a stable and reproducible way by 3D liver segmentation of noncontrast cardiac CT scans. Future studies need to explore the sensitivity and stability of measures for low liver fat content by 3D segmentation, over the current 2D methodology. This measure can serve as an imaging biomarker to understand mechanistic correlations between atherosclerosis, fatty liver, and cardiovascular disease risk.
- 26 August 2021
- Published by Elsevier in Atherosclerosis
- Vol. 335, 126-134
Bone mineral density and long-term progression of aortic valve and mitral annular calcification: The Multi-Ethnic Study of Atherosclerosis
- 26 August 2021
- Published by Elsevier in Atherosclerosis
- Vol. 335, 126-134
Bone mineral density and long-term progression of aortic valve and mitral annular calcification: The Multi-Ethnic Study of Atherosclerosis
- 1 September 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 220 (3) , 707-711
Effect of Electrocardiogram Triggering on Reproducibility of Coronary Artery Calcium Scoring
To test the hypothesis that computed tomographic (CT) scanning during early rather than middle diastole can significantly reduce the interscan variability of coronary artery calcium (CAC) scores. Five hundred thirty-eight patients were initially enrolled; 282 of them were found to have CAC at electron-beam CT and underwent repeat scanning to measure interscan variability with different electrocardiogram (ECG) triggers. Eight patients were excluded owing to respiratory motion; thus, 274 asymptomatic patients were examined. Patients were randomly assigned to different ECG trigger interval groups: 40% (group 1), 50% (group 2), 60% (group 3), and 80% (group 4). Patients in whom more than one-third of sections had greater than 10% ECG trigger variability were classified in the untriggered group (group 5). Interscan variation was compared among all five groups. Interscan variabilities in CAC groups 1-5 were 11.5%, 15.3%, 20.3%, 17.4%, and 33.1%, respectively, for total calcium area, and 15.0%, 23.3%, 25.6%, 24.0%, and 42.4%, respectively, for total calcium score. CAC score variability was reduced by 34%; and calcium area variability, by 38% in group 1, as compared with the reduced variabilities in group 4 (P <.01 for both measures). Breath holding was adequate in 812 cases, and ECG triggering was correct in 790 of cases. Study results strongly support the use of an ECG trigger of 40% rather than 80% of the R-R interval in electron-beam CT calcium studies.
- 1 September 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 220 (3) , 707-711
Effect of Electrocardiogram Triggering on Reproducibility of Coronary Artery Calcium Scoring
To test the hypothesis that computed tomographic (CT) scanning during early rather than middle diastole can significantly reduce the interscan variability of coronary artery calcium (CAC) scores. Five hundred thirty-eight patients were initially enrolled; 282 of them were found to have CAC at electron-beam CT and underwent repeat scanning to measure interscan variability with different electrocardiogram (ECG) triggers. Eight patients were excluded owing to respiratory motion; thus, 274 asymptomatic patients were examined. Patients were randomly assigned to different ECG trigger interval groups: 40% (group 1), 50% (group 2), 60% (group 3), and 80% (group 4). Patients in whom more than one-third of sections had greater than 10% ECG trigger variability were classified in the untriggered group (group 5). Interscan variation was compared among all five groups. Interscan variabilities in CAC groups 1-5 were 11.5%, 15.3%, 20.3%, 17.4%, and 33.1%, respectively, for total calcium area, and 15.0%, 23.3%, 25.6%, 24.0%, and 42.4%, respectively, for total calcium score. CAC score variability was reduced by 34%; and calcium area variability, by 38% in group 1, as compared with the reduced variabilities in group 4 (P <.01 for both measures). Breath holding was adequate in 812 cases, and ECG triggering was correct in 790 of cases. Study results strongly support the use of an ECG trigger of 40% rather than 80% of the R-R interval in electron-beam CT calcium studies.