Alfred P. Yoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alfred P. Yoon has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Kevin C. Chung
Section of Plastic Surgery, Department of Surgery, University of Michigan Medical School
2 shared publications - Chang-Fu Kuo
Center for Artificial Intelligence in Medicine, Chang Gung Memorial Hospital, Taoyuan, Taiwan
1 shared publication - Chien-Wei Wang
University of Michigan Medical School
1 shared publication - Chihung Lin
Center for Artificial Intelligence in Medicine, Chang Gung Memorial Hospital, Taoyuan 333, Taiwan
1 shared publication D. Li
Division of Hospital Medicine, Emory School of Medicine, Atlanta, CA, United States
1 shared publication- David W. Hutton
Department of Health Management and Policy University of Michigan School of Public Health Ann Arbor Michigan USA
1 shared publication
Latest Publications
- Open Access
- 20 August 2024
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e65596
Effects of Image Degradation on Deep Neural Network Classification of Scaphoid Fracture Radiographs: A Comparison of Different Noise Types (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Deep learning models have shown strong potential for automated fracture detection on medical images. However, their robustness under varying image quality remains uncertain, particularly for small and subtle fractures such as scaphoid fractures. Understanding how different types of image perturbations affect model performance is crucial for ensuring reliable deployment in clinical practice. Objective: This study aimed to evaluate the robustness of a deep learning model trained to detect scaphoid fractures in radiographs when exposed to various image perturbations. We sought to identify which perturbations most strongly impact performance and to explore strategies to mitigate performance degradation. Methods: Radiographic datasets were systematically modified by applying Gaussian noise, blurring, JPEG compression, contrast-limited adaptive histogram equalization (CLAHE), resizing, and geometric offsets. Model accuracy was evaluated across different perturbation types and levels. Image quality was quantified using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) to assess correlations between degradation and model performance. Results: Model accuracy declined with increasing perturbation severity, but the extent varied across perturbation types. Gaussian blur caused the most substantial performance drop, whereas CLAHE increased the false-negative rate. The model demonstrated higher resilience to color perturbations than to grayscale degradations. A strong linear correlation was found between PSNR/SSIM and accuracy, suggesting that better image quality led to improved detection. Geometric offsets and pixel value rescaling had minimal influence, while resolution was the dominant factor affecting performance. Conclusions: The findings indicate that image quality, especially resolution and blurring, substantially influences the robustness of deep learning–based fracture detection models. Ensuring adequate image resolution and quality control can enhance diagnostic reliability. These results provide valuable insights for designing more accurate and resilient medical imaging models under real-world variability.
- 20 August 2024
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 14, e65596
Open AccessEffects of Image Degradation on Deep Neural Network Classification of Scaphoid Fracture Radiographs: A Comparison of Different Noise Types (Preprint)
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Deep learning models have shown strong potential for automated fracture detection on medical images. However, their robustness under varying image quality remains uncertain, particularly for small and subtle fractures such as scaphoid fractures. Understanding how different types of image perturbations affect model performance is crucial for ensuring reliable deployment in clinical practice. Objective: This study aimed to evaluate the robustness of a deep learning model trained to detect scaphoid fractures in radiographs when exposed to various image perturbations. We sought to identify which perturbations most strongly impact performance and to explore strategies to mitigate performance degradation. Methods: Radiographic datasets were systematically modified by applying Gaussian noise, blurring, JPEG compression, contrast-limited adaptive histogram equalization (CLAHE), resizing, and geometric offsets. Model accuracy was evaluated across different perturbation types and levels. Image quality was quantified using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) to assess correlations between degradation and model performance. Results: Model accuracy declined with increasing perturbation severity, but the extent varied across perturbation types. Gaussian blur caused the most substantial performance drop, whereas CLAHE increased the false-negative rate. The model demonstrated higher resilience to color perturbations than to grayscale degradations. A strong linear correlation was found between PSNR/SSIM and accuracy, suggesting that better image quality led to improved detection. Geometric offsets and pixel value rescaling had minimal influence, while resolution was the dominant factor affecting performance. Conclusions: The findings indicate that image quality, especially resolution and blurring, substantially influences the robustness of deep learning–based fracture detection models. Ensuring adequate image resolution and quality control can enhance diagnostic reliability. These results provide valuable insights for designing more accurate and resilient medical imaging models under real-world variability.
- 5 June 2021
- Published by Oxford University Press (OUP) in Journal of Burn Care & Research
- Vol. 43 (2) , 440-444
Long-Term Outcomes After Toe-To-Thumb Transfers for Burn Reconstruction in Children
Children are one of the most vulnerable populations to burns, and hands are frequently burned anatomical structures. Restoring function in a severely burned pediatric hand is challenging. We present our experience with pediatric toe-to-thumb transfers for burn reconstruction. A retrospective review was conducted of all pediatric toe-to-thumb transfer patients between 2009 and 2014. Children younger than the age of 18 who underwent secondary reconstruction after electrical or thermal burn injuries with at least a 5-year follow-up were included. Functional outcomes were measured with the modified Kapandji score. Complications of the reconstructed hand as well as the donor foot were recorded. Four children with 10 toe-to-hand transfers (four great toes, two second toes, and two combined second–third toes) met the inclusion criteria. The average follow-up length was 104 months (range 60–144 months). Two children sustained thermal burn injuries and two sustained electrical burn injuries. Three children achieved opposition of the reconstructed toe-to-thumb transfer to the small finger (Kapandji score 5), and one child achieved opposition of the reconstructed toe-to-thumb transfer to the proximal phalanx of the middle finger, the only remaining finger (Kapandji score 3). No donor foot morbidities were noted postoperatively. Toe-to-thumb transfers should be considered the standard of care for thumb reconstruction in children with severe burn injuries of their hands to provide restoration of sensation, pinch, grasp, and opposition with minimal morbidity of the donor foot.
- 5 June 2021
- Published by Oxford University Press (OUP) in Journal of Burn Care & Research
- Vol. 43 (2) , 440-444
Long-Term Outcomes After Toe-To-Thumb Transfers for Burn Reconstruction in Children
Children are one of the most vulnerable populations to burns, and hands are frequently burned anatomical structures. Restoring function in a severely burned pediatric hand is challenging. We present our experience with pediatric toe-to-thumb transfers for burn reconstruction. A retrospective review was conducted of all pediatric toe-to-thumb transfer patients between 2009 and 2014. Children younger than the age of 18 who underwent secondary reconstruction after electrical or thermal burn injuries with at least a 5-year follow-up were included. Functional outcomes were measured with the modified Kapandji score. Complications of the reconstructed hand as well as the donor foot were recorded. Four children with 10 toe-to-hand transfers (four great toes, two second toes, and two combined second–third toes) met the inclusion criteria. The average follow-up length was 104 months (range 60–144 months). Two children sustained thermal burn injuries and two sustained electrical burn injuries. Three children achieved opposition of the reconstructed toe-to-thumb transfer to the small finger (Kapandji score 5), and one child achieved opposition of the reconstructed toe-to-thumb transfer to the proximal phalanx of the middle finger, the only remaining finger (Kapandji score 3). No donor foot morbidities were noted postoperatively. Toe-to-thumb transfers should be considered the standard of care for thumb reconstruction in children with severe burn injuries of their hands to provide restoration of sensation, pinch, grasp, and opposition with minimal morbidity of the donor foot.
- Open Access
- 1 February 2021
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 147 (2) , 240e-252e
Cost-Effectiveness of Treatments after Closed Extraarticular Distal Radius Fractures in Older Adults from the WRIST Clinical Trial
Background: This study performs an economic analysis of volar locking plate, external fixation, percutaneous pinning, or casting in elderly patients with closed distal radius fractures. Methods: This is a secondary analysis of the Wrist and Radius Injury Surgical Trial, a randomized, multicenter, international clinical trial with a parallel nonoperative casted group of patients older than 60 years with surgically indicated, extraarticular closed distal radius fractures. Thirty-Six-Item Short-Form Health Survey–converted utilities and total costs from Medicare were used to calculate quality-adjusted life-years and incremental cost-effectiveness ratio. Results: Casted patients were self-selected and older (p < 0.001) than the randomized surgical cohorts, but otherwise similar in sociodemographic characteristics. Quality-adjusted life-years for percutaneous pinning were highest at 9.17 and external fixation lowest at 8.81. Total costs expended were $16,354 for volar locking plates, $16,012 for external fixation, $11,329 for percutaneous pinning, and $6837 for casting. The incremental cost-effectiveness ratios for volar locking plates and external fixation were dominated by percutaneous pinning and casting. The ratio for percutaneous pinning compared to casting was $28,717. Probabilistic sensitivity analysis revealed a 10, 5, 53, and 32 percent chance of volar locking plate, external fixation, percutaneous pinning, and casting, respectively, being cost-effective at the willingness-to-pay threshold of $100,000 per quality-adjusted life-year. Conclusions: Casting is the most cost-effective treatment modality in the elderly with closed extraarticular distal radius fractures and should be considered before surgery. In unstable closed fractures, percutaneous pinning, which is the most cost-effective surgical intervention, may be considered before volar locking plates or external fixation.
- 1 February 2021
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 147 (2) , 240e-252e
Open AccessCost-Effectiveness of Treatments after Closed Extraarticular Distal Radius Fractures in Older Adults from the WRIST Clinical Trial
Background: This study performs an economic analysis of volar locking plate, external fixation, percutaneous pinning, or casting in elderly patients with closed distal radius fractures. Methods: This is a secondary analysis of the Wrist and Radius Injury Surgical Trial, a randomized, multicenter, international clinical trial with a parallel nonoperative casted group of patients older than 60 years with surgically indicated, extraarticular closed distal radius fractures. Thirty-Six-Item Short-Form Health Survey–converted utilities and total costs from Medicare were used to calculate quality-adjusted life-years and incremental cost-effectiveness ratio. Results: Casted patients were self-selected and older (p < 0.001) than the randomized surgical cohorts, but otherwise similar in sociodemographic characteristics. Quality-adjusted life-years for percutaneous pinning were highest at 9.17 and external fixation lowest at 8.81. Total costs expended were $16,354 for volar locking plates, $16,012 for external fixation, $11,329 for percutaneous pinning, and $6837 for casting. The incremental cost-effectiveness ratios for volar locking plates and external fixation were dominated by percutaneous pinning and casting. The ratio for percutaneous pinning compared to casting was $28,717. Probabilistic sensitivity analysis revealed a 10, 5, 53, and 32 percent chance of volar locking plate, external fixation, percutaneous pinning, and casting, respectively, being cost-effective at the willingness-to-pay threshold of $100,000 per quality-adjusted life-year. Conclusions: Casting is the most cost-effective treatment modality in the elderly with closed extraarticular distal radius fractures and should be considered before surgery. In unstable closed fractures, percutaneous pinning, which is the most cost-effective surgical intervention, may be considered before volar locking plates or external fixation.
- Open Access
- 1 October 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 136, 25
Reverse Radial Forearm Flap to Provide Arterial Inflow to a Toe Transfer
- 1 October 2015
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 136, 25
Open AccessReverse Radial Forearm Flap to Provide Arterial Inflow to a Toe Transfer