Mesut Tuzlalı
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mesut Tuzlalı has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Nagehan Baki
Department of Prosthodontics, Faculty of Dentistry, Inonu University, 44280 Malatya, Türkiye
12 shared publications - Erkan Bahçe
Department of Mechanical Engineering, Faculty of Engineering, Inönü University, 44280 Malatya, Türkiye
7 shared publications - Nazik İrEm Onugoren
Department of Prosthodontics, Faculty of Dentistry, Inonu University, 44280 Malatya, Türkiye
5 shared publications - Güler Yildirim Avcu
Department of Prosthodontics, Faculty of Dentistry, Fırat University, 23119 Elazığ, Turkey
4 shared publications - Cüneyt Asım Aral
Inonu University, Faculty of Dentistry, Department of Periodontology, Malatya, Turkey
3 shared publications - Hilal Şiriner Gümüş
Asst. Prof., Private Clinic, İstanbul/Türkiye
3 shared publications
Latest Publications
- 11 September 2026
- Published by Halic University Journal of Health Sciences in Haliç Üniversitesi Sağlık Bilimleri Dergisi
- Vol. 9 (3) , 1-3
Telediş Hekimliğinde Büyük Dil Modeli (BDM) Destekli Hasta Bilgilendirme ve Randevu Yönlendirme Uygulamalarına İlişkin Kavramsal ve Yöntemsel Öneriler
Bu editöre mektup, telediş hekimliğinde büyük dil modeli (BDM) tabanlı sohbet botlarının hasta bilgilendirme ve randevu yönlendirme süreçlerinde kullanımına ilişkin kavramsal ve yöntemsel gerekliliklere dikkat çekmektedir. Mevcut çalışmalar, bu sistemlerin ağız-diş sağlığı sorularına yanıt üretme potansiyelini göstermekte; ancak kullanım amacı, değerlendirme metrikleri, güvenlik sınırları ve raporlama biçimleri açısından belirgin farklılıklar bulunmaktadır. Özellikle dental enfeksiyon, yüz-boyun şişliği, trismus, disfaji, dispne ve sistemik bulgular gibi zaman-duyarlı klinik durumlarda kırmızı bayrakların ve eskalasyon protokollerinin açık biçimde tanımlanması hasta güvenliği açısından kritik önemdedir. Bu nedenle, BDM destekli hasta bilgilendirme ve randevu yönlendirme uygulamaları için model bilgisi, kullanım amacı, girdi senaryoları, güvenlik/eskalasyon kuralları, değerlendirme metrikleri, insan değerlendirici özellikleri, raporlama şeffaflığı ve veri gizliliği başlıklarını içeren bir asgari raporlama veri seti önerilmektedir. Bu çerçevenin, telediş hekimliği alanındaki çalışmaların karşılaştırılabilirliğini artıracağı ve hasta güvenliği odaklı kalite güvencesine katkı sağlayacağı düşünülmektedir.
- 11 September 2026
- Published by Halic University Journal of Health Sciences in Haliç Üniversitesi Sağlık Bilimleri Dergisi
- Vol. 9 (3) , 1-3
Telediş Hekimliğinde Büyük Dil Modeli (BDM) Destekli Hasta Bilgilendirme ve Randevu Yönlendirme Uygulamalarına İlişkin Kavramsal ve Yöntemsel Öneriler
Bu editöre mektup, telediş hekimliğinde büyük dil modeli (BDM) tabanlı sohbet botlarının hasta bilgilendirme ve randevu yönlendirme süreçlerinde kullanımına ilişkin kavramsal ve yöntemsel gerekliliklere dikkat çekmektedir. Mevcut çalışmalar, bu sistemlerin ağız-diş sağlığı sorularına yanıt üretme potansiyelini göstermekte; ancak kullanım amacı, değerlendirme metrikleri, güvenlik sınırları ve raporlama biçimleri açısından belirgin farklılıklar bulunmaktadır. Özellikle dental enfeksiyon, yüz-boyun şişliği, trismus, disfaji, dispne ve sistemik bulgular gibi zaman-duyarlı klinik durumlarda kırmızı bayrakların ve eskalasyon protokollerinin açık biçimde tanımlanması hasta güvenliği açısından kritik önemdedir. Bu nedenle, BDM destekli hasta bilgilendirme ve randevu yönlendirme uygulamaları için model bilgisi, kullanım amacı, girdi senaryoları, güvenlik/eskalasyon kuralları, değerlendirme metrikleri, insan değerlendirici özellikleri, raporlama şeffaflığı ve veri gizliliği başlıklarını içeren bir asgari raporlama veri seti önerilmektedir. Bu çerçevenin, telediş hekimliği alanındaki çalışmaların karşılaştırılabilirliğini artıracağı ve hasta güvenliği odaklı kalite güvencesine katkı sağlayacağı düşünülmektedir.
- 29 June 2026
- Published by Medical Research Reports in Medical Research Reports
- Vol. 9 (2) , 77-91
Quantifying Workflow-Induced Vertical Measurement Variability Between Pre- and Post-Preparation Intraoral Scans on Typodont Models: A Primescan–Exocad Study
Aim: Preoperative intraoral scans are routinely used as baseline references for CAD/CAM restoration design by superimposing them with post-preparation scans. This study quantified the workflow-induced apparent vertical discrepancy between pre- and post-preparation intraoral scan datasets after a clinically common registration approach. Method: Twelve maxillary typodont models were scanned at baseline (T0) with an intraoral scanner. A standardized full-crown preparation was performed on a preselected tooth (FDI 14; maxillary right first premolar), followed by post-preparation scanning (T1). T0 and T1 meshes were aligned in dental CAD software using rigid 3-point registration. Apparent vertical (tooth long-axis) differences (|ΔL|, mm) were measured on non-prepared reference teeth (maxillary central incisor, canine, and first molar) to isolate scan–registration variability. Descriptive statistics and empirical cumulative distribution functions were reported. Tooth-type differences were tested using the Friedman test with Holm-adjusted post hoc comparisons (α=0.05). Results: Across 36 measurements, median (IQR) |ΔL| was 0.039 (0.020–0.049) mm for the central incisor, 0.051 (0.037–0.176) mm for the canine, and 0.021 (0.012–0.102) mm for the first molar. The 95th percentiles were 0.311, 0.382, and 0.164 mm, respectively; maximum values approached 0.4–0.5 mm. Overall differences among tooth types were significant (P=0.039), whereas pairwise comparisons were not significant after adjustment. Conclusion: Pre/post intraoral scan superimposition using rigid 3-point alignment can generate non-zero apparent vertical discrepancies on unchanged teeth, occasionally reaching several tenths of a millimeter. Small pre/post differences—used to guide CAD/CAM design—should therefore be interpreted cautiously as they may reflect workflow variability rather than true morphologic change.
- 29 June 2026
- Published by Medical Research Reports in Medical Research Reports
- Vol. 9 (2) , 77-91
Quantifying Workflow-Induced Vertical Measurement Variability Between Pre- and Post-Preparation Intraoral Scans on Typodont Models: A Primescan–Exocad Study
Aim: Preoperative intraoral scans are routinely used as baseline references for CAD/CAM restoration design by superimposing them with post-preparation scans. This study quantified the workflow-induced apparent vertical discrepancy between pre- and post-preparation intraoral scan datasets after a clinically common registration approach. Method: Twelve maxillary typodont models were scanned at baseline (T0) with an intraoral scanner. A standardized full-crown preparation was performed on a preselected tooth (FDI 14; maxillary right first premolar), followed by post-preparation scanning (T1). T0 and T1 meshes were aligned in dental CAD software using rigid 3-point registration. Apparent vertical (tooth long-axis) differences (|ΔL|, mm) were measured on non-prepared reference teeth (maxillary central incisor, canine, and first molar) to isolate scan–registration variability. Descriptive statistics and empirical cumulative distribution functions were reported. Tooth-type differences were tested using the Friedman test with Holm-adjusted post hoc comparisons (α=0.05). Results: Across 36 measurements, median (IQR) |ΔL| was 0.039 (0.020–0.049) mm for the central incisor, 0.051 (0.037–0.176) mm for the canine, and 0.021 (0.012–0.102) mm for the first molar. The 95th percentiles were 0.311, 0.382, and 0.164 mm, respectively; maximum values approached 0.4–0.5 mm. Overall differences among tooth types were significant (P=0.039), whereas pairwise comparisons were not significant after adjustment. Conclusion: Pre/post intraoral scan superimposition using rigid 3-point alignment can generate non-zero apparent vertical discrepancies on unchanged teeth, occasionally reaching several tenths of a millimeter. Small pre/post differences—used to guide CAD/CAM design—should therefore be interpreted cautiously as they may reflect workflow variability rather than true morphologic change.
- 17 June 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (3) , 812-820
Weibull survival modeling of laminate veneers using aggregated data from published clinical cohorts
- 17 June 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (3) , 812-820
Weibull survival modeling of laminate veneers using aggregated data from published clinical cohorts
- Open Access
- 18 March 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (3) , 149
Mechanostat-Informed Strain Mapping of Osseodensification-Inspired Peri-Implant Densification Versus Conventional Drilling in Osteoporotic-like Low-Density Cancellous Bone: A 3D Static Linear Finite Element Analysis
Low-density cancellous bone results in reduced trabecular support and may increase crestal cortical strain around implants. Osseodensification (OD) compacts trabecular bone and may create a peri-osteotomy densified zone, but its strain-level effects in osteoporotic-like bone are unclear. This study evaluated whether an OD-inspired peri-implant densified trabecular zone reduces crestal cortical strain compared with conventional drilling (CD) in an osteoporotic-like model. A three-dimensional finite element model of a mandibular posterior segment with a 2.0-mm cortical shell and D4 cancellous core was constructed with a 4.3 × 11.4-mm titanium implant and a cemented monolithic zirconia crown. CD used a 4.0-mm osteotomy in D4 bone. The OD model used the same osteotomy plus a concentric peri-implant densified shell with radial density gradation from D1 to D3. The implant–bone interface was defined as bonded. Static 100 N axial and 45° oblique loads were applied. Outcomes were εeq, εmax, and εmin, summarized as mean top-10 nodal values. OD reduced crestal cortical strains under both loads. Under axial loading, εeq, εmax, and |εmin| decreased by 17.7%, 19.0%, and 24.1%, respectively. Under oblique loading, the corresponding reductions were 9.8%, 8.0%, and 8.9%. Oblique loading produced higher cortical strains than axial loading in both models. OD-inspired peri-implant densification reduced crestal cortical strain in this osteoporotic-like model, whereas oblique loading remained the main driver of elevated strain. These findings support occlusal/prosthetic strategies that minimize oblique forces and warrant experimental and clinical validation.
- 18 March 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (3) , 149
Open AccessMechanostat-Informed Strain Mapping of Osseodensification-Inspired Peri-Implant Densification Versus Conventional Drilling in Osteoporotic-like Low-Density Cancellous Bone: A 3D Static Linear Finite Element Analysis
Low-density cancellous bone results in reduced trabecular support and may increase crestal cortical strain around implants. Osseodensification (OD) compacts trabecular bone and may create a peri-osteotomy densified zone, but its strain-level effects in osteoporotic-like bone are unclear. This study evaluated whether an OD-inspired peri-implant densified trabecular zone reduces crestal cortical strain compared with conventional drilling (CD) in an osteoporotic-like model. A three-dimensional finite element model of a mandibular posterior segment with a 2.0-mm cortical shell and D4 cancellous core was constructed with a 4.3 × 11.4-mm titanium implant and a cemented monolithic zirconia crown. CD used a 4.0-mm osteotomy in D4 bone. The OD model used the same osteotomy plus a concentric peri-implant densified shell with radial density gradation from D1 to D3. The implant–bone interface was defined as bonded. Static 100 N axial and 45° oblique loads were applied. Outcomes were εeq, εmax, and εmin, summarized as mean top-10 nodal values. OD reduced crestal cortical strains under both loads. Under axial loading, εeq, εmax, and |εmin| decreased by 17.7%, 19.0%, and 24.1%, respectively. Under oblique loading, the corresponding reductions were 9.8%, 8.0%, and 8.9%. Oblique loading produced higher cortical strains than axial loading in both models. OD-inspired peri-implant densification reduced crestal cortical strain in this osteoporotic-like model, whereas oblique loading remained the main driver of elevated strain. These findings support occlusal/prosthetic strategies that minimize oblique forces and warrant experimental and clinical validation.
- Open Access
- 12 March 2026
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 9 (2) , 452-461
3D-printed zirconia in dentistry: a bibliometric analysis of global research trends
Aims: Three-dimensional (3D) printing of zirconia is an emerging domain in digital dentistry; however, its global research landscape, collaboration structure, and thematic focus have not been comprehensively mapped. The aim of this study was to characterize scientific output, collaboration patterns, citation impact, and major research themes in publications on 3D-printed zirconia in dentistry.Methods: A Web of Science Core Collection (WoS-CC) Topic Search was conducted in December 2025 using terms related to zirconia, additive manufacturing/3D printing, and dental applications. Of 584 retrieved records, 185 eligible articles on 3D-printed zirconia for dental use (2009–2025) were included. Descriptive indicators were calculated (annual production, journals, countries, institutions, authors, and citations). Co-authorship and keyword co-occurrence networks were generated with VOSviewer to visualize collaboration and identify thematic clusters.Results: Publication activity increased sharply after 2019, with 128/185 publications (69.2%) published in 2023–2025. Most documents were original research articles (n=159) or reviews (n=26); no case reports were identified in WoS-CC. The 185 articles involved 730 authors from 38 countries and were published in 48 journals. China and the United States were leading contributors. Network analyses identified three interconnected themes: digital/additive manufacturing workflows, implantprosthodontic applications, and biomechanical or accuracy-based evaluation. Evidence was predominantly in vitro and laboratory-based, with limited clinical data.Conclusion: Research on 3D-printed zirconia in dentistry is rapidly expanding but concentrated in a small set of countries, institutions, and journals. Future studies should prioritize clinical investigations and standardized reporting of printing and post-processing parameters to support translation into predictable outcomes.
- 12 March 2026
- Published by Journal of Health Sciences and Medicine in Journal of Health Sciences and Medicine
- Vol. 9 (2) , 452-461
Open Access3D-printed zirconia in dentistry: a bibliometric analysis of global research trends
Aims: Three-dimensional (3D) printing of zirconia is an emerging domain in digital dentistry; however, its global research landscape, collaboration structure, and thematic focus have not been comprehensively mapped. The aim of this study was to characterize scientific output, collaboration patterns, citation impact, and major research themes in publications on 3D-printed zirconia in dentistry.Methods: A Web of Science Core Collection (WoS-CC) Topic Search was conducted in December 2025 using terms related to zirconia, additive manufacturing/3D printing, and dental applications. Of 584 retrieved records, 185 eligible articles on 3D-printed zirconia for dental use (2009–2025) were included. Descriptive indicators were calculated (annual production, journals, countries, institutions, authors, and citations). Co-authorship and keyword co-occurrence networks were generated with VOSviewer to visualize collaboration and identify thematic clusters.Results: Publication activity increased sharply after 2019, with 128/185 publications (69.2%) published in 2023–2025. Most documents were original research articles (n=159) or reviews (n=26); no case reports were identified in WoS-CC. The 185 articles involved 730 authors from 38 countries and were published in 48 journals. China and the United States were leading contributors. Network analyses identified three interconnected themes: digital/additive manufacturing workflows, implantprosthodontic applications, and biomechanical or accuracy-based evaluation. Evidence was predominantly in vitro and laboratory-based, with limited clinical data.Conclusion: Research on 3D-printed zirconia in dentistry is rapidly expanding but concentrated in a small set of countries, institutions, and journals. Future studies should prioritize clinical investigations and standardized reporting of printing and post-processing parameters to support translation into predictable outcomes.
- Open Access
- 24 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2181
Weibull-Based Reliability of Full-Arch Zirconia Prostheses in a Mandibular All-on-4 Model: Monolithic Versus Titanium-Bar-Supported Designs
Full-arch zirconia prostheses for mandibular All-on-4 rehabilitations are provided as screw-retained monolithic zirconia (Zr-Mono) or as a zirconia suprastructure luted to a CAD/CAM titanium bar (Zr-TiBar). Because zirconia is a brittle and flaw-sensitive ceramic, design assessment should incorporate stress-field-weighted fracture risk. This in silico study compared zirconia tensile stress, deformation, and Weibull-based reliability between Zr-Mono and Zr-TiBar designs in a standardized edentulous mandibular All-on-4 model (posterior implants tilted 30°) using linear static finite element analysis. Accordingly, 300 N posterior unilateral loads were applied at the first molar (axial; 45° oblique). Outcomes were maximum principal tensile stress in zirconia (S1max), total prosthesis deformation, and Weibull-predicted fracture probability (Pf) derived from the tensile S1 field. Under axial loading, S1max was essentially identical between designs (~277 MPa). Under oblique loading, S1max was modestly lower for Zr-TiBar (~227 MPa) than for Zr-Mono (~234 MPa), and deformation was slightly lower for Zr-TiBar (Pf remained very low for both designs (10−6–10−7 range) and differed only slightly between them. Under the modeled single 300 N posterior load case, the titanium-bar support reduced deformation and modestly reduced oblique-load peak tensile stress but did not materially reduce the predicted zirconia Pf compared with monolithic zirconia.
- 24 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2181
Open AccessWeibull-Based Reliability of Full-Arch Zirconia Prostheses in a Mandibular All-on-4 Model: Monolithic Versus Titanium-Bar-Supported Designs
Full-arch zirconia prostheses for mandibular All-on-4 rehabilitations are provided as screw-retained monolithic zirconia (Zr-Mono) or as a zirconia suprastructure luted to a CAD/CAM titanium bar (Zr-TiBar). Because zirconia is a brittle and flaw-sensitive ceramic, design assessment should incorporate stress-field-weighted fracture risk. This in silico study compared zirconia tensile stress, deformation, and Weibull-based reliability between Zr-Mono and Zr-TiBar designs in a standardized edentulous mandibular All-on-4 model (posterior implants tilted 30°) using linear static finite element analysis. Accordingly, 300 N posterior unilateral loads were applied at the first molar (axial; 45° oblique). Outcomes were maximum principal tensile stress in zirconia (S1max), total prosthesis deformation, and Weibull-predicted fracture probability (Pf) derived from the tensile S1 field. Under axial loading, S1max was essentially identical between designs (~277 MPa). Under oblique loading, S1max was modestly lower for Zr-TiBar (~227 MPa) than for Zr-Mono (~234 MPa), and deformation was slightly lower for Zr-TiBar (Pf remained very low for both designs (10−6–10−7 range) and differed only slightly between them. Under the modeled single 300 N posterior load case, the titanium-bar support reduced deformation and modestly reduced oblique-load peak tensile stress but did not materially reduce the predicted zirconia Pf compared with monolithic zirconia.
- Open Access
- 18 February 2026
- Published by MDPI AG in Preprints.org
Mechanostat-Informed Strain Mapping of Osseodensification-Inspired Peri-Implant Densification in Osteoporotic-Like Low-Density Cancellous Bone: A 3D Static Linear Finite Element Analysis
Background/Objectives: Low-density cancellous bone can amplify crestal cortical strain around implants because trabecular support is reduced. Osseodensification (OD) compacts trabecular bone and may create a peri-osteotomy densified zone, but its strain-level effects in osteoporotic-like bone are unclear. Given that osteoporosis/osteopenia in aging populations reduce trabecular support and can increase crestal cortical loading, this study tested whether an OD-inspired peri-implant densified trabecular zone lowers high-tail crestal cortical strains versus conventional drilling in an osteoporotic-like cancellous model. Materials and Methods: A 3D finite element mandibular posterior segment (2.0-mm cortical shell and D4 cancellous core) was modeled with a 4.3×11.4-mm titanium implant and a cemented monolithic zirconia crown. CD used a 4.0-mm osteotomy in D4 bone. OD used the same osteotomy plus an axially varying concentric densified shell (D1→D3 radially) with minor buccolingual cortical expansion. The implant–bone interface was bonded. Static 100 N loads were applied axially and obliquely (45°). Outcomes were εeq, εmax, and εmin, summarized as mean top-10 nodal values. Results: OD reduced crestal cortical strains under both loads. Axial loading: εeq 1470→1210 µε (−17.7%), εmax 1420→1150 µε (−19.0%), |εmin| 900→683 µε (−24.1%). Oblique loading: εeq 3370→3040 µε (−9.8%), εmax 2510→2310 µε (−8.0%), |εmin| 3040→2770 µε (−8.9%). Oblique loading produced higher cortical strains than axial loading in both models. Conclusions: OD-inspired peri-implant densification attenuated high-tail crestal cortical strain demand in this osteoporotic-like model, whereas off-axis loading remained the dominant driver of elevated strain. These findings support occlusal/prosthetic strategies that minimize oblique forces and warrant experimental and clinical validation.
- 18 February 2026
- Published by MDPI AG in Preprints.org
Open AccessMechanostat-Informed Strain Mapping of Osseodensification-Inspired Peri-Implant Densification in Osteoporotic-Like Low-Density Cancellous Bone: A 3D Static Linear Finite Element Analysis
Background/Objectives: Low-density cancellous bone can amplify crestal cortical strain around implants because trabecular support is reduced. Osseodensification (OD) compacts trabecular bone and may create a peri-osteotomy densified zone, but its strain-level effects in osteoporotic-like bone are unclear. Given that osteoporosis/osteopenia in aging populations reduce trabecular support and can increase crestal cortical loading, this study tested whether an OD-inspired peri-implant densified trabecular zone lowers high-tail crestal cortical strains versus conventional drilling in an osteoporotic-like cancellous model. Materials and Methods: A 3D finite element mandibular posterior segment (2.0-mm cortical shell and D4 cancellous core) was modeled with a 4.3×11.4-mm titanium implant and a cemented monolithic zirconia crown. CD used a 4.0-mm osteotomy in D4 bone. OD used the same osteotomy plus an axially varying concentric densified shell (D1→D3 radially) with minor buccolingual cortical expansion. The implant–bone interface was bonded. Static 100 N loads were applied axially and obliquely (45°). Outcomes were εeq, εmax, and εmin, summarized as mean top-10 nodal values. Results: OD reduced crestal cortical strains under both loads. Axial loading: εeq 1470→1210 µε (−17.7%), εmax 1420→1150 µε (−19.0%), |εmin| 900→683 µε (−24.1%). Oblique loading: εeq 3370→3040 µε (−9.8%), εmax 2510→2310 µε (−8.0%), |εmin| 3040→2770 µε (−8.9%). Oblique loading produced higher cortical strains than axial loading in both models. Conclusions: OD-inspired peri-implant densification attenuated high-tail crestal cortical strain demand in this osteoporotic-like model, whereas off-axis loading remained the dominant driver of elevated strain. These findings support occlusal/prosthetic strategies that minimize oblique forces and warrant experimental and clinical validation.
- Open Access
- 2 February 2026
- Published by MDPI AG in Preprints.org
Weibull-Based Reliability of Full-Arch Zirconia Prostheses in a Mandibular All-on-4 Model: Monolithic Versus Titanium-Bar–Supported Designs
Background/Objectives: Full-arch zirconia prostheses for mandibular All-on-4 rehabilitations are provided as screw-retained monolithic zirconia or as a zirconia suprastructure luted to a CAD/CAM titanium bar. Because zirconia is a brittle, flaw-sensitive ceramic, design assessment should incorporate stress-field–weighted fracture risk. This in-silico study compared zirconia tensile stress and Weibull-based reliability between monolithic (Zr-Mono) and titanium-bar–supported zirconia (Zr-TiBar) designs. Methods: A standardized 3D edentulous mandibular All-on-4 model (four 4.3×11.5-mm implants; posterior implants tilted 30°) with multi-unit abutments and Ti-bases was analyzed using linear static finite element analysis. Posterior unilateral loads were applied to the first molar (300 N axial; 300 N at 45° oblique). Outcomes were maximum principal tensile stress in zirconia (S1max), total prosthesis deformation, and Weibull-predicted probability of zirconia fracture (m = 7.41; σ0 = 576.5 MPa) derived from the tensile S1 field. Results: Under axial loading, S1max was similar (Zr-Mono 277.09 MPa; Zr-TiBar 277.13 MPa). Under oblique loading, S1max was lower for Zr-TiBar (226.94 MPa) than for Zr-Mono (233.82 MPa). Deformation was <0.07 mm and lower for Zr-TiBar (0.0607 mm axial; 0.0589 mm oblique) than for Zr-Mono (0.0635 mm axial; 0.0660 mm oblique). The Weibull-predicted probability of fracture was very low: axial 1.309×10⁻⁶ (Zr-Mono) vs 1.473×10⁻⁶ (Zr-TiBar); oblique 1.589×10⁻⁷ vs 1.790×10⁻⁷. Conclusions: Both designs showed comparably low Weibull-predicted fracture probability under single 300 N posterior loads. Titanium-bar support reduced deformation and modestly reduced peak tensile stress under oblique loading, but did not reduce the predicted fracture probability relative to monolithic zirconia.
- 2 February 2026
- Published by MDPI AG in Preprints.org
Open AccessWeibull-Based Reliability of Full-Arch Zirconia Prostheses in a Mandibular All-on-4 Model: Monolithic Versus Titanium-Bar–Supported Designs
Background/Objectives: Full-arch zirconia prostheses for mandibular All-on-4 rehabilitations are provided as screw-retained monolithic zirconia or as a zirconia suprastructure luted to a CAD/CAM titanium bar. Because zirconia is a brittle, flaw-sensitive ceramic, design assessment should incorporate stress-field–weighted fracture risk. This in-silico study compared zirconia tensile stress and Weibull-based reliability between monolithic (Zr-Mono) and titanium-bar–supported zirconia (Zr-TiBar) designs. Methods: A standardized 3D edentulous mandibular All-on-4 model (four 4.3×11.5-mm implants; posterior implants tilted 30°) with multi-unit abutments and Ti-bases was analyzed using linear static finite element analysis. Posterior unilateral loads were applied to the first molar (300 N axial; 300 N at 45° oblique). Outcomes were maximum principal tensile stress in zirconia (S1max), total prosthesis deformation, and Weibull-predicted probability of zirconia fracture (m = 7.41; σ0 = 576.5 MPa) derived from the tensile S1 field. Results: Under axial loading, S1max was similar (Zr-Mono 277.09 MPa; Zr-TiBar 277.13 MPa). Under oblique loading, S1max was lower for Zr-TiBar (226.94 MPa) than for Zr-Mono (233.82 MPa). Deformation was <0.07 mm and lower for Zr-TiBar (0.0607 mm axial; 0.0589 mm oblique) than for Zr-Mono (0.0635 mm axial; 0.0660 mm oblique). The Weibull-predicted probability of fracture was very low: axial 1.309×10⁻⁶ (Zr-Mono) vs 1.473×10⁻⁶ (Zr-TiBar); oblique 1.589×10⁻⁷ vs 1.790×10⁻⁷. Conclusions: Both designs showed comparably low Weibull-predicted fracture probability under single 300 N posterior loads. Titanium-bar support reduced deformation and modestly reduced peak tensile stress under oblique loading, but did not reduce the predicted fracture probability relative to monolithic zirconia.
- Open Access
- 27 November 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1)
Biomechanical evaluation of three full-arch immediate loading protocols in the mandible via finite element analysis: All-on-4, Trefoil, and Five-implant design
Immediate-loading full-arch concepts such as All-on-4, Trefoil, and Five-Implant protocols are widely used for mandibular rehabilitation, yet their compara
- 27 November 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1)
Open AccessBiomechanical evaluation of three full-arch immediate loading protocols in the mandible via finite element analysis: All-on-4, Trefoil, and Five-implant design
Immediate-loading full-arch concepts such as All-on-4, Trefoil, and Five-Implant protocols are widely used for mandibular rehabilitation, yet their compara
- 13 November 2025
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- p. 1-13
Stress distribution and prosthesis deformation analysis of different bar materials considering weight in trefoil implant system under various loading conditions: a finite element study
This study evaluated seven bar materials-Titanium (Ti), Cobalt-Chromium (Co-Cr), Zirconia (Zr), Polyetheretherketone (PEEK), Carbon-Fiber-Reinforced PEEK (CFR-PEEK), 3D-printed resin (3D-Pr), and Polymethyl methacrylate (PMMA)-in the Trefoil implant system using three-dimensional finite element analysis under vertical and oblique loads. Stress distribution and prosthesis deformation were analyzed, and a Performance Index combining mass and deformation was calculated. Bar material mainly influenced deformation: metallic bars (Ti, Co-Cr, Zr) showed minimal, while non-metallic (3D-Pr, PMMA) showed higher deformation. Titanium had the best performance, followed by zirconia and CFR-PEEK. Selecting optimal bar materials enhances biomechanical efficiency in Trefoil prostheses.
- 13 November 2025
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- p. 1-13
Stress distribution and prosthesis deformation analysis of different bar materials considering weight in trefoil implant system under various loading conditions: a finite element study
This study evaluated seven bar materials-Titanium (Ti), Cobalt-Chromium (Co-Cr), Zirconia (Zr), Polyetheretherketone (PEEK), Carbon-Fiber-Reinforced PEEK (CFR-PEEK), 3D-printed resin (3D-Pr), and Polymethyl methacrylate (PMMA)-in the Trefoil implant system using three-dimensional finite element analysis under vertical and oblique loads. Stress distribution and prosthesis deformation were analyzed, and a Performance Index combining mass and deformation was calculated. Bar material mainly influenced deformation: metallic bars (Ti, Co-Cr, Zr) showed minimal, while non-metallic (3D-Pr, PMMA) showed higher deformation. Titanium had the best performance, followed by zirconia and CFR-PEEK. Selecting optimal bar materials enhances biomechanical efficiency in Trefoil prostheses.