    Techno-Economic Optimization of a Grid-Tied Photovoltaic System for Schools in Saudi Arabia

    by Jarah Adeeb Alqasim, Fahad Alhamli, Khaled Kunnah, Nagmeldeen A. M. Hassanain

    The educational sector in Saudi Arabia represents a significant portion of the national energy load, with government-constructed buildings accounting for approximately 13% of the total consumption, largely driven by air conditioning demands in the harsh climate of the Eastern Province. This project investigates the techno-economic feasibility of integrating a grid-tied photovoltaic (PV) system into a standard elementary school in Dammam to reduce operational costs and align with the renewable energy targets of Saudi Vision 2030. Using HelioScope for physical design and HOMER Pro for economic optimization, a 149 kWp solar PV system was modeled for the “Al Madinah Al Munawwarah School.” Although initially modeled to evaluate hybrid configurations, the optimization demonstrated that a strictly grid-tied PV system was the most viable. The design utilized the building rooftop and football court structure to overcome space constraints, deploying 240 high-efficiency panels. The simulation results indicate that the proposed system generates sufficient energy to reduce the grid reliance of the school from 100% to 52.1%, reducing the peak demand during active academic hours. The techno-economic analysis reveals a levelized cost of energy (LCOE) of 0.23 SAR/kWh, which is significantly lower than the governmental tariff of 0.32 SAR/kWh. The project demonstrates strong financial viability with a net present cost (NPC) reduction of 15% compared with the base case, a simple payback period of 7.5 years, and an internal rate of return (IRR) of 12.6%. Replicating this model could significantly relieve the municipal grid, validating the strategic advantage of school rooftops for decentralized generation.

  • Open Access

    Techno-Economic Assessment of PEM Electrolyzer Coupled with High-Concentration Photovoltaics in Saudi Arabia

    by Gaydaa AlZohbi, Nagmeldeen A. M. Hassanain, Muhammad Saleem, Nassir Hariri, Mohamed Elsharawy, Farooq Saeed, Taher Maatallah, Tapas Kumar Mallick, Fahad Gallab Al-Amri

    Green hydrogen (H2) production is a pivotal element of Saudi Arabia’s Vision 2030. This study presents a comprehensive feasibility assessment of a high-efficiency H2 production system integrating a photovoltaic (PV) array and a high-concentration photovoltaic (HCPV) system with a Proton Exchange Membrane (PEM) electrolyzer, specifically designed for harsh climatic conditions. To evaluate the system’s viability, a comprehensive simulation model was developed based on rigorously validated mathematical formulations. First, the performance of the PEM electrolyzer and the effectiveness of the cooling system were modeled using established electrochemical and thermal correlations derived from the peer-reviewed literature. Second, this model was applied to evaluate the system’s long-term energy yield and economic performance. Key economic metrics, including the levelized cost of H2 (LCOH) and discounted payback period (DPBP), were calculated based on local solar irradiance data, followed by a sensitivity analysis to assess the economic robustness under varying market conditions. The results demonstrate that the proposed configuration is not only technically feasible—maintaining high efficiency despite harsh environmental conditions—but also economically viable, offering a competitive LCOH and attractive DPBP that align with the strategic objectives of Saudi Vision 2030.

  • Open Access

    Numerical Study of Single-Layer and Stacked Minichannel-Based Heat Sinks Using Different Truncating Ratios for Cooling High Concentration Photovoltaic Systems

    by Ahmed T. Okasha, Fahad Ghallab Al-Amri, Taher Maatallah, Nagmeldeen A. M. Hassanain, Abdullah Khalid Alghamdi, Richu Zachariah

    The present research aims to discuss and analyze the performance of truncated single-layer and stacked mini-channel-based heat sinks employed for the cooling of a single-cell high concentrating photovoltaic systems. The truncating technique of the fins at the entrance and exit regions from the internal fluid mini channels is opted to reduce the energy, raw material costs and time of the manufacturing process of the mini channels. This proposed solution is constrained by several metrics such as the thermal management and the overall performance of the high concentrating photovoltaic system. In the current research, the use of a truncating ratio of 31% has yielded minimum cell temperature and maximum electrical efficiencies for both single-layer and stacked mini-channel-based heat sinks, while a truncating ratio of 65% has enabled more uniform cell temperature distribution. Moreover, a truncating ratio of 65% has qualified the highest water outlet temperature and the lowest pressure drops relatively compared to the conventional mini-channel-based heat sink configurations. The highest water temperature has reached up to 52.7 ∘C by the stacked mini-channel-based heat sink with a truncating ratio of 65% under a geometrical concentration ratio of 2000× and a mass flow rate of 0.001kgs−1. For both the single-layer and stacked mini-channel-based heat sinks, the use of a truncating ratio of 65% has driven the upper hands to achieve higher ratio of the thermal power to the pumping power (RTP). The maximum RTP values have been recorded by the single-layer mini-channel-based heat sink with a truncating ratio of 65% equal to 23.61 ×106 and 233.06 ×103 at a mass flow rate of 0.008kgs−1 and 0.001kgs−1, respectively, under 2000×.


  • Open Access

    An Experimental Investigation on the Effectiveness of Integrated Heat Pipe-Water Immersion Cooling Technique on the Solar Panel's Performance

    by Sajid Ali, Nagmeldeen A. M. Hassanain, Ijlal S. Ateeq, Fahad Ghallab

    The usefulness of an active cooling technique on the PV panel's electrical and thermal performance in harsh climate was established in this study. Four heat pipes were submerged in a liquid container and connected to the rear of a solar PV panel. The intention is to transmit thermal energy using evaporative cooling and buoyant flow in the heat pipes. The liquid inside the evaporator part is vaporized via hot water, and this heat is moved to the condenser section of the heat pipe. The proposed cooling mechanism is implemented in one PV panel, whereas the second PV panel was without the cooling mechanism. Variation in the PV panel's instantaneous temperature in case of with and without cooling reveals that the temperature of the panel cooled by water-immersed heat pipes stayed lower than that of the panel that did not have an active cooling system. A maximum temperature reduction of about 49% was observed in case of active cooling. Effect of the proposed cooling method on the power output of the PV panel was also analyzed. The solar panel having a cooling system results in 8% more power output than the solar PV panel that does not have a cooling system.

  • Steady-state performance assessment of three- and five-phase permanent magnet generators connected to a diode bridge rectifier under open-circuit faults

    by N.E.A.M. Hassanain, J.E. Fletcher

    Small-scale wind turbines often utilise permanent magnet generators that supply power via an uncontrolled diode rectifier. In such systems, a custom generator design is required to optimise the aerodynamic and electromechanical performance; therefore the phase number of the generator is not restricted. This study assesses and compares the performance of prototype 700 W five- and three-phase permanent magnet generators connected to a diode bridge rectifier and their performance under open-circuit fault conditions. The simulation and experimental results demonstrate that the five-phase system can utilise a smaller DC-link capacitor and develops lower shaft torque ripple compared to the three-phase system. The three-phase generator can only tolerate one single-phase open-circuit failure. However, three possible open-circuit phase failure modes are considered in the five-phase machine: a single open-circuit phase and two open-circuit phases, where the two phases can be adjacent or non-adjacent. It is shown that the shaft torque ripple and output power are superior in the five-phase system with both the single-phase failure mode and the non-adjacent phase failure mode compared to the three-phase system with a single-phase failure. However, the adjacent phase failure mode is more extreme and generates less output power than the three-phase system. Simulation and finite-element analysis results are verified by experiments on the prototype 30-slot, four-pole, double-layer, surface-mounted permanent magnet generator.


  • Performance analysis of salient-pole self-excited reluctance generators using a simplified model

    by Y.H.A. Rahim, J.E. Fletcher, N.E.A.M. Hassanain

    A simple, direct mathematical model is developed for steady-state analysis of salient-pole, self-excited synchronous reluctance generators. The model does not require either the power consumed by the load or the ratio of the load to excitation current to be estimated which are prerequisite assumptions of previous analysis techniques. The model is verified by experiment which includes assessment of critical speed, excitation capacitance, no-load terminal voltage and voltage regulation on load. The experiments are performed using a prototype synchronous reluctance generator. The analysis technique is then used to investigate the effect that saliency, stator resistance and power factor have on the performance of the self-excited system.


  • Novel Five-Phase Permanent Magnet Generator Systems for Wind Turbine Applications

    by M. T. Mohammad, J. E. Fletcher, N. A. Hassanain

    This paper discusses the benefits of five-phase technology for applications including wind turbine generators. The performances of three-phase and five-phase permanent magnet generator (PMG) systems that use diode rectifier circuits are discussed. Investigations proved that the five-phase topology harnesses some specific and important benefits that are not provided by three-phase systems. The benefits include improved fault tolerance and reliability, and reduced voltage and torque ripple and size of DC link capacitor. These are general improvements that are sought after in many applications including renewable energy applications. The paper also discusses the design of a novel five-phase wind turbine generator which was optimised to make use of the key competitive advantages of our five-phase technology in renewable energy sector. Finite element (FE) and Matlab / Simulink are used in the investigations. Test results are also presented in this paper and used to validate simulations where possible.


  • Challenges to machine windings used in electrical generators in wave and tidal power plants

    by Thomas Judendorfer, John Fletcher, Nagm Hassanain, Markus Mueller, Michael Muhr

    The majority of electrical generators in wave and tidal power plants are face harsh environmental conditions. Particularly the seals between the moving shaft and the stationary generator as these are mechanically stressed under pressure of the sea water. Flooding the electrical generator and the air gap respectively is a possible solution that would overcome seal failure. With this proposal, the strains on the seals can be reduced as they would have to seal non-moving parts against the sea water only. The lifetime of seals could be prolonged with this measure. On the other hand, this will also result in changes to the electrical behavior of the windings and the electrical machine respectively. This is the subject of this paper. Mainly, these are changes to the winding capacitances. They result in a different transient behavior, for example when the machine is operated with switched inverters. The performance of six different insulation materials for the submersion in sea water are studied and the results are compared to the standard operation in air. Furthermore, with the changed sealing methods the thermal characteristics are altered, which will be also analyzed within this work.


  • Electrical issues associated with sea-water immersed windings in electrical generators for wave- and tidal current-driven power generation

    by J. Fletcher, T. Judendorfer, M. Mueller, N. Hassanain, M. Muhr

    For the majority of proposed wave- and tidal current-driven power generation applications, the electrical generators are submerged in sea water, frequently at many metres of depth. The environment places significant stress on the rotating or translating seals between the driven shaft and the electrical generator leading to reduced reliability and lifetime. A potential solution is to eliminate the seal, thereby flooding the generator and allowing sea water to circulate around the shaft, windings and rotor of the machine. The impact of immersing the windings of the machine in sea water is assessed here. Specifically, the impact that the insulation has on the leakage capacitance as well as the consequent impact the leakage capacitance has on current and voltage oscillations in the switching converter used to excite the winding is assessed. Thermal tests are conducted to assess the impact of the insulation on the thermal conductance of the coil–insulation system. Experimental evidence is provided.


  • Analysis three- and five-phase permanent magnet machines supplying diode bridge rectifiers for small-scale wind generators

    by N.A.M. Hassanain, J.E. Fletcher

    In this paper, performance of three- and five-phase permanent magnet generators (PMG) feeding a rectifier system are compared for small-scale wind generator systems. The volume and rated speeds of the two generators are kept equal and determined using FEM 2D. No-load induced voltage, self and mutual inductances and resistance are calculated and used to simulate the performance of the 3-phase and 5-phase generators coupled to a dc link through a diode bridge rectifier. Generator mathematical models are developed and simulated. The simulations show that five-phase system has torque ripple that is a factor of 7 lower than the three-phase system with an almost identical efficiency figure.