Abdullah Khalid Alghamdi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdullah Khalid Alghamdi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed T. Okasha
Department of Mechanical and Energy Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, Dammam 34212, Saudi Arabia
2 shared publications - Fahad Ghallab Al‐Amri
Department of Mechanical and Energy Engineering, College of Engineering Imam Abdulrahman Bin Faisal University Dammam Saudi Arabia
2 shared publications - Richu Zachariah
Department of Mechanical Engineering, Amal Jyothi College of Engineering, Kanjirappally 686518, Kerala, India
2 shared publications - Taher Maatallah
Mechanical and Energy Engineering Department, Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
2 shared publications - Nagmeldeen A. M. Hassanain
Department of Electronic and Electrical Engineering, University of Strathclyde, 204 George Street, Glasgow, UK
1 shared publication
Latest Publications
- Open Access
- 29 April 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (9) , 5352
Numerical Study of Single-Layer and Stacked Minichannel-Based Heat Sinks Using Different Truncating Ratios for Cooling High Concentration Photovoltaic Systems
The present research aims to discuss and analyze the performance of truncated single-layer and stacked mini-channel-based heat sinks employed for the cooling of a single-cell high concentrating photovoltaic systems. The truncating technique of the fins at the entrance and exit regions from the internal fluid mini channels is opted to reduce the energy, raw material costs and time of the manufacturing process of the mini channels. This proposed solution is constrained by several metrics such as the thermal management and the overall performance of the high concentrating photovoltaic system. In the current research, the use of a truncating ratio of 31% has yielded minimum cell temperature and maximum electrical efficiencies for both single-layer and stacked mini-channel-based heat sinks, while a truncating ratio of 65% has enabled more uniform cell temperature distribution. Moreover, a truncating ratio of 65% has qualified the highest water outlet temperature and the lowest pressure drops relatively compared to the conventional mini-channel-based heat sink configurations. The highest water temperature has reached up to 52.7 by the stacked mini-channel-based heat sink with a truncating ratio of 65% under a geometrical concentration ratio of 2000× and a mass flow rate of −1. For both the single-layer and stacked mini-channel-based heat sinks, the use of a truncating ratio of 65% has driven the upper hands to achieve higher ratio of the thermal power to the pumping power (RTP). The maximum RTP values have been recorded by the single-layer mini-channel-based heat sink with a truncating ratio of 65% equal to 23.61 × and 233.06 × at a mass flow rate of −1 and −1, respectively, under 2000×.- 29 April 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (9) , 5352
Open AccessNumerical Study of Single-Layer and Stacked Minichannel-Based Heat Sinks Using Different Truncating Ratios for Cooling High Concentration Photovoltaic Systems
The present research aims to discuss and analyze the performance of truncated single-layer and stacked mini-channel-based heat sinks employed for the cooling of a single-cell high concentrating photovoltaic systems. The truncating technique of the fins at the entrance and exit regions from the internal fluid mini channels is opted to reduce the energy, raw material costs and time of the manufacturing process of the mini channels. This proposed solution is constrained by several metrics such as the thermal management and the overall performance of the high concentrating photovoltaic system. In the current research, the use of a truncating ratio of 31% has yielded minimum cell temperature and maximum electrical efficiencies for both single-layer and stacked mini-channel-based heat sinks, while a truncating ratio of 65% has enabled more uniform cell temperature distribution. Moreover, a truncating ratio of 65% has qualified the highest water outlet temperature and the lowest pressure drops relatively compared to the conventional mini-channel-based heat sink configurations. The highest water temperature has reached up to 52.7 by the stacked mini-channel-based heat sink with a truncating ratio of 65% under a geometrical concentration ratio of 2000× and a mass flow rate of −1. For both the single-layer and stacked mini-channel-based heat sinks, the use of a truncating ratio of 65% has driven the upper hands to achieve higher ratio of the thermal power to the pumping power (RTP). The maximum RTP values have been recorded by the single-layer mini-channel-based heat sink with a truncating ratio of 65% equal to 23.61 × and 233.06 × at a mass flow rate of −1 and −1, respectively, under 2000×. - Open Access
- 31 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (7) , 4142
Enhanced Net Channel Based-Heat Sink Designs for Cooling of High Concentration Photovoltaic (HCPV) Systems in Dammam City
In this study, enhanced net channel based heat sink designs for cooling HCPV systems at geometrical concentration ratios ranging from 500× to 3000× are presented. The effect of increasing the number of layers in the parallel flow net channel, as well as the fraction of the coolant mass flow rate in the counter flow net channel, on the overall performance of the HCPV systems, are investigated. The various configurations of each proposed net channel based-heat sink design are examined, and a comparative analysis between the different proposed designs is performed under the climate weather conditions of Dammam city, Saudi Arabia. On one hand, the double-layered counter flow net channel heat sink outperformed the other designs in terms of electrical efficiency and in keeping the solar cell operating well below the safe operating limits, achieving a reduction in maximum cell temperature relatively compared to the parallel flow net channel with five layers and conventional mini channel of 11.72% and 12.01%, respectively. On the other hand, for effective usability of the heat recovery rate by the cooling mechanism, the parallel flow net channel is the most appropriate design since it has recorded 27.55% higher outlet water temperature than the double-layered counter flow net channel.
- 31 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (7) , 4142
Open AccessEnhanced Net Channel Based-Heat Sink Designs for Cooling of High Concentration Photovoltaic (HCPV) Systems in Dammam City
In this study, enhanced net channel based heat sink designs for cooling HCPV systems at geometrical concentration ratios ranging from 500× to 3000× are presented. The effect of increasing the number of layers in the parallel flow net channel, as well as the fraction of the coolant mass flow rate in the counter flow net channel, on the overall performance of the HCPV systems, are investigated. The various configurations of each proposed net channel based-heat sink design are examined, and a comparative analysis between the different proposed designs is performed under the climate weather conditions of Dammam city, Saudi Arabia. On one hand, the double-layered counter flow net channel heat sink outperformed the other designs in terms of electrical efficiency and in keeping the solar cell operating well below the safe operating limits, achieving a reduction in maximum cell temperature relatively compared to the parallel flow net channel with five layers and conventional mini channel of 11.72% and 12.01%, respectively. On the other hand, for effective usability of the heat recovery rate by the cooling mechanism, the parallel flow net channel is the most appropriate design since it has recorded 27.55% higher outlet water temperature than the double-layered counter flow net channel.