RLReza Lotfi

Reza Lotfi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Reza Lotfi has a total of 49 co-authors. Here are the top co-authors by number of shared publications:

  • Mehdi Saberi

    Department of Electrical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran

    6 shared publications
  • Fariborz Rezaeitalab

    Department of Neurology, Quaem Hospital, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

    2 shared publications
  • Hamed Aminzadeh

    Department of Electrical Engineering, Payame Noor University (PNU), Tehran, Iran

    2 shared publications
  • Hosna Ghandeharioun

    Department of Electrical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran

    2 shared publications
  • Afsaneh Zeinalzadeh

    Department of Physical Therapy, School of Paramedical and Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran

    1 shared publication
  • Afsaneh Zeinalzadeh

    Department of Physical Therapy, School of Paramedical and Rehabilitation Sciences, Mashhad University of Medical Sciences, Mashhad, Iran

    1 shared publication

Latest Publications

  • Design of a Low-Cost Real-Time Angle Sensor Module for Dynamic Body-Weight Support Systems Using Inertial Measurement Unit and Fusion Algorithms

    by Hossein Yaghoobzadeh Shadmehri, Shahin Jafarabadi Ashtiani, Ehsan Rahiminejad, Afsaneh Zeinalzadeh, Reza Lotfi

    Dynamic Body Weight-Support (DBWS) systems are used for patients with mobility impairments. These systems provide three key functions—dynamic body-weight support, fall prevention, and synchronized propulsion—all of which were designed and implemented in this study. One of the most important parameters in a DBWS system is the angle between the patient and the device, which is measured by an angle-estimation module. The problem addressed in this research is the design and construction of a low-cost angle measurement module that is minimally sensitive to vibration, maintains high precision, and has a fast response time. This module is suitable for rehabilitation applications (for example DBWS system) that require high precision and are subject to significant vibration. In this paper, by using an inertial measurement unit (IMU) sensor and a switching logic between different filters based on data fusion, low sensitivity to vibration (vibrations caused by mechanical oscillations) and high response speed are achieved. Outputs of Madgwick and Kalman filters (MF and KF) are fused to obtain the angle from the IMU. The MF is employed to detect rapid movements, and two KFs with high and low measurement noise values (HMNV-KF and LMNV-KF) are used to measure the angle. When rapid angular changes occur, the output angle is obtained from the LMNV-KF; otherwise, the HMNV-KF is used. Additionally, a low-pass filter is applied to the LMNV-KF output after fast angular changes have ended but before the HMNV-KF reaching its steady value. The results obtained from the DBWS system show that the proposed algorithm outperforms all other filters in terms of response speed and vibration sensitivity, making it highly suitable for the intended application. The rise time is 171.33 ms, and the maximum error is 0.54°, both of which are lower than those of all other tested filters.

  • An Improved Readout Circuit for Enhanced Accuracy and Frame Rate in Large Resistive Sensor Arrays Using Adaptive Techniques

    by Mohammad Tavakkoli Ghouchani, Mehran Jalaian Mohammad Nia, Reza Lotfi

    Sensor arrays have gained significant traction in both industrial and medical applications due to their versatile utility. This paper introduces innovative adaptive measurement techniques and circuit implementations aimed at elevating the accuracy, dynamic range, and readout speed of resistive sensor arrays. The proposed circuit employs a dynamic gain for the transimpedance amplifier, effectively mitigating the impact of parasitic resistances through an analog compensation architecture. Furthermore, a novel two-step readout algorithm is introduced, aimed at improving the frame rate of the system. This new approach leads to approximately six times improvement in readout speed compared to conventional algorithms for a plantar pressure array employed in gait analysis. Notably, all proposed methodologies are fully compatible with large-scale resistive arrays, as demonstrated in a 40-row by 240-column plantar pressure sensor implementation.


  • Open Access

    Effectiveness of Gait Training Using Dynamic Bodyweight Support System on Locomotor Abilities of Ambulatory Children With Different Neural Disorders

    by Afsaneh Zeinalzadeh, Reza Lotfi, Hasan Barmaki, Mohammad Lotfi, Alireza Shadman, Ali Asadi, Hamid Reza Kobravi

    Background: In this study, we evaluated the efficacy of dynamic bodyweight-supported training on the gait quality of children with different neural disorders. Methods: Seventeen ambulatory children, aged 3 to 11 years, experiencing gait limitations, were selected to participate in the designed gait training program. Each child participated in 10 practice sessions held three days a week, with each training session using the dynamic body weight support system, comprising three stages, and lasting 20 minutes. Clinical assessments were conducted using four functional tests: "Five Time Sit to Stand Test (FSST)", "Modified Time Up and Go (MTUG)", "Time Up and Down Stairs (TUDS)", and "Pediatric Berg Balance Scale" (BBS). Results: Statistical tests demonstrated a significant increase in the post-values of the BBS after gait training. Notably, children with higher relative cognitive abilities showed more improvement. Additionally, there was a significant enhancement in the assigned score for the level of independence. As all participants had received conventional physical therapies for more than three years, reaching their maximum obtainable improvements with conventional training methods, the observed improvements could be attributed to the designed training protocol even without a control group. Conclusion: Designed gait training protocol using a dynamic weight support system proved effective in enhancing balance, improving gait quality, and increasing the level of independence during performing functional tests in ambulatory children suffering from different locomotor disabilities.


  • Versatile DAC-less successive approximation ADC architecture for medium speed data acquisition

    by Ali Pourahmad, Rasoul Dehghani, Seyed Amir-Reza Ahmadi-Mehr, Reza Lotfi


  • Speed-Power Improvement in High-Voltage Switches Employed in Multielectrode Arrays

    by Amin Safarpour, Farzaneh Dehnavi, Mehdi Saberi, Reza Lotfi, Wouter A. Serdijn

    In multi-electrode arrays (MEAs), for electrical recording and electrical stimulation, high voltage (HV) switches are employed to build an analog multiplexer to conduct either a HV stimulation signal from the pulse generator circuit to an electrode or a low-voltage noise-sensitive signal from the electrode to a recording stage. In this paper, a new circuit structure is proposed for HV switches that significantly improves their switching speed, reduces their power dissipation, and also employs a minimum number of bulky HV devices. In order to reduce the transition time of the proposed switch without consuming a large amount of power, during the transition time that the switch is turning on/off, a large current flows through the driver circuit of the switch to turn the switch on/off rapidly; however, after the transition times, this current is significantly reduced to save power. Based on the proposed HV switch, a multiplexer structure has been implemented in 25-V, 0.18-μm CMOS IC technology and the measurement results prove its efficacy. Supplied with 25 V and operating with 300 nA current consumption, this switch swings over 20 V with a relatively constant on-resistance of 100 Ω and features a 80 ns transition time.


  • A Two-Step Readout Technique for Large-Array Resistive Sensors

    by Sara Ghamsari, Mohammad Tavakkoli Qouchani, Sadjad Rahmanpour, Payman Amel Zendedel, Reza Lotfi

    Large-array resistive sensors have nowadays found various applications in a variety of medical and industrial systems. In this paper, a two-step readout procedure is proposed, which increases the average speed of the readout for the input patterns, located in an area much smaller than the entire array. In the proposed method, during the first step, only a spatially coarse scan is performed where the location of the input is roughly estimated. Then, during the second step, the values of the resistors are accurately measured, just within the allocated area. Measurement results of a 52×44 resistive array used in a plantar pressure scanner show that the average readout time for a gait pattern is reduced from 23 ms for the conventional circuit to 5.7 ms using the proposed technique.


  • Energy-Efficient Wide-Range Voltage Level Shifters Reaching 4.2 fJ/Transition

    by Reza Lotfi, Mehdi Saberi, S. Rasool Hosseini, Amir Reza Ahmadi-Mehr, Robert Bogdan Staszewski

    This letter proposes a new level-shifting structure that can convert extremely low levels of input voltages to high output voltages while maintaining excellent delay and power dissipation. In order to reduce contention and voltage swing in the internal nodes, the proposed circuit uses a diode-connected level shifter between gate terminals of the output inverter. Using a control circuit, only during the high-to-low transitions of the output, a current is forced into the diode-connected device. Measurement results demonstrate that the proposed circuit can consume as small energy as 4.2 fJ/transition with VDDL and VDDH of 0.35 V and 1.1 V, respectively, when implemented in a 40-nm CMOS technology. Furthermore, when fabricated in a 180-nm technology, the level-shifting circuit can convert VDDL as small as 80 mV to 1.8 V without using low-threshold devices.


  • A Charge-Redistribution Phase-Domain ADC Using an IQ-Assisted Binary-Search Algorithm

    by Leila Rajabi, Mehdi Saberi, Yao Liu, Reza Lotfi, Wouter A. Serdijn

    Phase-domain Analog-to-Digital Converters (Ph-ADCs) have been considered for power-efficient implementation of body-area network transceivers employing phase demodulation. Conventional implementations of the Ph-ADCs, which work based on a full-flash zero-crossing algorithm, use linear resistive/current combiners to determine the thermometer digital code of the signal phase. These architectures suffer from high-accuracy requirements, high-circuit complexity, and high-power consumption. Therefore, in this paper, a new IQ-assisted binary-search algorithm is proposed for implementing the Ph-ADC. The proposed Ph-ADC architecture avoids employing the power-hungry linear combiner. Moreover, for an $N$-bit Ph-ADC, the proposed algorithm requires only $N$+1 comparisons, whereas the conventional full-flash counterpart demands 2N-1 comparisons. Based on the proposed architecture, two different 5-bit charge-redistribution Ph-ADCs are designed and one of them is fabricated in a standard 0.18-μm CMOS technology. The prototype achieves an ENOB of 4.85 bits at 1 MS/s, while dissipating 12.9 μW from a 1.2-V supply.


  • A fully-synchronous offset-insensitive level-crossing analog-to-digital converter

    by Nassim Ravanshad, Hamidreza Rezaee-Dehsorkh, Reza Lotfi

    A fully-synchronous offset-insensitive structure is proposed for implementing level-crossing analog-to-digital converters (LC-ADCs). The proposed structure is designed and implemented for high-precision compressed electrocardiogram (ECG) monitoring applications. Synchronous implementation leads to less implementation complexity compared to the conventional asynchronous implementations. Also the major source of error, viz. the difference in comparators offsets is eliminated which additionally leads to considerable saving in silicon area. Designing and simulating in a 0.18 μm CMOS technology, the LC-ADC achieves an ENOB of 8.45 bits and occupies 0.038 mm2 silicon area. The average sampling rate is about 120 S/s when applied to the whole MIT/BIH arrhythmia database. Simulation results show a power consumption of 81 nW with a 1.8 V supply voltage, by testing the ADC using Tape 100 of the MIT/BIH arrhythmia database.


  • A Power-Efficient Signal-Specific ADC for Sensor-Interface Applications

    by Ehsan Rahiminejad, Mehdi Saberi, Reza Lotfi

    A novel signal-specific power-efficient analog-to-digital converter (ADC) is proposed for sensor-interface applications. Instead of digitizing each analog sample independently, the proposed ADC determines the digital code corresponding to each new input sample by digitizing the difference of two consecutive samples. Therefore, for the applications with low-varying input signals, such as image sensors and ECG readouts, the difference of two consecutive samples is much smaller than the ADC full-scale range for the majority of the input samples, the power consumption of the capacitive digital-to-analog converter, the comparator, and the digital circuits of the proposed ADC is saved due to reducing the ADC activity. The prototype was fabricated using a 0.18-μm CMOS technology. Measurement results of 1 V, 8 bit, 20 kS/s ADC confirm that for a 10-kHz input sine wave, the effective number of bits is 7 while the power consumption of the entire ADC is 1.12 μW. However, for the same sampling rate, the power consumption is only 106 nW for a low-varying 100-Hz input sine wave.