Fredrik Domhagen
Research Subjects
Fredrik Domhagen has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Angela Sasic Kalagasidis
Chalmers University of Technology
3 shared publications Carl-Eric Hagentoft
3 shared publications- Sarka Langer
IVL Swedish Environmental Research Institute
3 shared publications Paula Wahlgren
Department for Architecture and Civil Engineering, Division of Building Technology, Chalmers University of Technology, Gothenburg, Sweden
2 shared publicationsBijan Adl-Zarrabi
1 shared publication- Paula Wahlgren
Department of Architecture and Civil Engineering, Chalmers University of Technology, SE-412 96 Gothenburg, Sweden
1 shared publication
Latest Publications
- Open Access
- 18 October 2025
- Published by Elsevier in Indoor Environments
- Vol. 2 (4)
Modeling VOC-emissions in a building using Laplace networks – simplified models, explicit expressions and typical timescales
- 18 October 2025
- Published by Elsevier in Indoor Environments
- Vol. 2 (4)
Open AccessModeling VOC-emissions in a building using Laplace networks – simplified models, explicit expressions and typical timescales
- Open Access
- 11 February 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (7) , 3838-3839
Rebuttal to Correspondence on “Theoretical Threshold for Estimating the Impact of Ventilation on Materials’ Emissions”
- 11 February 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (7) , 3838-3839
Open AccessRebuttal to Correspondence on “Theoretical Threshold for Estimating the Impact of Ventilation on Materials’ Emissions”
- Open Access
- 6 March 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (11) , 5058-5067
Theoretical Threshold for Estimating the Impact of Ventilation on Materials’ Emissions
In new buildings, nonoccupant VOC emissions are initially high but typically decrease within months. Increased ventilation is commonly used to improve indoor air quality, assuming it speeds up VOC off-gassing from materials. However, previous research presents inconsistent results. This review introduces a simplified analytical model to understand the ventilation-emission relationship. By combining factors such as diffusivity, emitting area, and time, the model suggests the existence of a theoretical ventilation threshold beyond which enhanced ventilation has no further influence on emission rates. A threshold of approximately 0.13 L s-1 m-2 emitting area has been found for various VOCs documented in the existing literature, with which the conflicting results are explained. It is also shown that the threshold remains notably consistent across different boundary conditions and model resolutions, indicating its suitability for real-world applications.
- 6 March 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (11) , 5058-5067
Open AccessTheoretical Threshold for Estimating the Impact of Ventilation on Materials’ Emissions
In new buildings, nonoccupant VOC emissions are initially high but typically decrease within months. Increased ventilation is commonly used to improve indoor air quality, assuming it speeds up VOC off-gassing from materials. However, previous research presents inconsistent results. This review introduces a simplified analytical model to understand the ventilation-emission relationship. By combining factors such as diffusivity, emitting area, and time, the model suggests the existence of a theoretical ventilation threshold beyond which enhanced ventilation has no further influence on emission rates. A threshold of approximately 0.13 L s-1 m-2 emitting area has been found for various VOCs documented in the existing literature, with which the conflicting results are explained. It is also shown that the threshold remains notably consistent across different boundary conditions and model resolutions, indicating its suitability for real-world applications.
- Open Access
- 29 April 2023
- Published by Elsevier in Building and Environment
- Vol. 238
Modelling VOC levels in a new office building using passive sampling, humidity, temperature, and ventilation measurements
- 29 April 2023
- Published by Elsevier in Building and Environment
- Vol. 238
Open AccessModelling VOC levels in a new office building using passive sampling, humidity, temperature, and ventilation measurements
- Open Access
- 6 September 2021
- Published by Springer Nature in Building Simulation
- Vol. 15 (5) , 845-858
Impact of weather conditions and building design on contaminant infiltration from crawl spaces in Swedish schools—Numerical modeling using Monte Carlo method
- 6 September 2021
- Published by Springer Nature in Building Simulation
- Vol. 15 (5) , 845-858
Open AccessImpact of weather conditions and building design on contaminant infiltration from crawl spaces in Swedish schools—Numerical modeling using Monte Carlo method
- Open Access
- 30 June 2020
- Published by EDP Sciences
- Vol. 172, 11004
Pressure distribution around the thermal envelope - a parametric study of the impact from wind and temperature on contaminant transport within a building
Several school buildings in Sweden have indoor air quality problems. The contaminant source is often assumed to come from within the construction, for example from the crawl space or attic space. Contaminants, in these cases, are transported by air leaking between compartments in the building. Here, the driving force for the air leakage is difference in pressure and, therefore, determining pressure also determines the direction of contaminant transport. In many cases, measures to improve the air quality are taken without a thorough understanding of how it might affect the pressure distribution in the building. In this paper a numerical model is used to examine how different climate scenarios and different building configurations affect the leakage and contaminant transport in a building with a crawl space. Results show that for leaky buildings the ventilation rate increases with increased wind and therefore the contaminant concentration decreases. The worst scenario in terms of high contaminant concentration is mild days with little wind. Also, when installing an exhaust fan in the crawl space with the purpose to prevent air from leaking from the crawl space to the classroom it is advisable to also consider the airtightness and the climate, not only the pressure difference across the floor.
- 30 June 2020
- Published by EDP Sciences
- Vol. 172, 11004
Open AccessPressure distribution around the thermal envelope - a parametric study of the impact from wind and temperature on contaminant transport within a building
Several school buildings in Sweden have indoor air quality problems. The contaminant source is often assumed to come from within the construction, for example from the crawl space or attic space. Contaminants, in these cases, are transported by air leaking between compartments in the building. Here, the driving force for the air leakage is difference in pressure and, therefore, determining pressure also determines the direction of contaminant transport. In many cases, measures to improve the air quality are taken without a thorough understanding of how it might affect the pressure distribution in the building. In this paper a numerical model is used to examine how different climate scenarios and different building configurations affect the leakage and contaminant transport in a building with a crawl space. Results show that for leaky buildings the ventilation rate increases with increased wind and therefore the contaminant concentration decreases. The worst scenario in terms of high contaminant concentration is mild days with little wind. Also, when installing an exhaust fan in the crawl space with the purpose to prevent air from leaking from the crawl space to the classroom it is advisable to also consider the airtightness and the climate, not only the pressure difference across the floor.
- Open Access
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 873-878
Consequences of Varying Airtightness in Wooden Buildings
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 873-878
Open AccessConsequences of Varying Airtightness in Wooden Buildings
- Open Access
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 309-314
Influence of oxidation on radiative heat transfer in polyurethane insulation used for district heating pipes
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 309-314
Open AccessInfluence of oxidation on radiative heat transfer in polyurethane insulation used for district heating pipes