Yongcan Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yongcan Zhu has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Xinbo Huang
Xi’an Polytechnic University
9 shared publications - Long Zhao
School of Electronics and Information, Xi’an Polytechnic University, Xi’an 710048, China
5 shared publications - Yi Tian
Xi’an Polytechnic University
4 shared publications - Chao Ji
Xi’an Polytechnic University, Xi’an, China
3 shared publications - Wen Cao
Xian Polytech Univ, Sch Elect Informat, Xian 710048, Peoples R China
3 shared publications - Xinsheng Dong
Power Science Research Institute of State Grid Xinjiang Electric Power Co., Ltd., Urumqi 830011, China
3 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (9)
Mitigating dynamic insulation breakdown in iced overhead ground lines: A differentiated dielectric shielding method with sequential electro-mechanical coupling analysis
In regions prone to severe icing, the nonlinear spatial galloping of overhead transmission lines can induce dynamic instability in conductor-to-ground wire clearances, leading to transient insulation breakdown. To address this dynamic dielectric failure mechanism, this paper proposes a novel differentiated insulation protection strategy that, for the first time, integrates explicit dynamic clearance analysis with electrostatic field computation to establish a spatial risk-zoning framework for overhead ground wires. Initially, a detailed explicit dynamic model of a 110 kV tower-line coupled system is constructed to elucidate the spatial risk evolution of ice-shedding induced transient responses; the resulting time-varying clearances are then subsequently fed into a dynamic gas–solid composite dielectric electric field model that is established to clarify the electric field distortion and ionization mechanism, where local field strength surges to 3.9 kV/mm (exceeding the air breakdown threshold) under critical micro-gap conditions. It is demonstrated that a 4–6 mm silicone rubber coating effectively suppresses the electric field to a safe margin through dielectric shielding by reconfiguring the interfacial capacitance distribution. Based on these findings, an adaptive gradient coating scheme is devised, assigning 6 mm full-arc, 5 mm semi-arc, and 4 mm partial coatings to high, medium, and low-risk sections, respectively, thereby optimizing both insulation resilience and material efficiency. Full-scale power frequency withstand voltage tests conclusively validate this mechanism, showing a substantial 47.26% increase in breakdown voltage under the extreme 1.9 m critical condition. This research provides a rigorous theoretical framework and an engineering paradigm rooted in sequential electro-mechanical coupling for proactive defense against transient electrical faults in power grids.
- 1 September 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (9)
Open AccessMitigating dynamic insulation breakdown in iced overhead ground lines: A differentiated dielectric shielding method with sequential electro-mechanical coupling analysis
In regions prone to severe icing, the nonlinear spatial galloping of overhead transmission lines can induce dynamic instability in conductor-to-ground wire clearances, leading to transient insulation breakdown. To address this dynamic dielectric failure mechanism, this paper proposes a novel differentiated insulation protection strategy that, for the first time, integrates explicit dynamic clearance analysis with electrostatic field computation to establish a spatial risk-zoning framework for overhead ground wires. Initially, a detailed explicit dynamic model of a 110 kV tower-line coupled system is constructed to elucidate the spatial risk evolution of ice-shedding induced transient responses; the resulting time-varying clearances are then subsequently fed into a dynamic gas–solid composite dielectric electric field model that is established to clarify the electric field distortion and ionization mechanism, where local field strength surges to 3.9 kV/mm (exceeding the air breakdown threshold) under critical micro-gap conditions. It is demonstrated that a 4–6 mm silicone rubber coating effectively suppresses the electric field to a safe margin through dielectric shielding by reconfiguring the interfacial capacitance distribution. Based on these findings, an adaptive gradient coating scheme is devised, assigning 6 mm full-arc, 5 mm semi-arc, and 4 mm partial coatings to high, medium, and low-risk sections, respectively, thereby optimizing both insulation resilience and material efficiency. Full-scale power frequency withstand voltage tests conclusively validate this mechanism, showing a substantial 47.26% increase in breakdown voltage under the extreme 1.9 m critical condition. This research provides a rigorous theoretical framework and an engineering paradigm rooted in sequential electro-mechanical coupling for proactive defense against transient electrical faults in power grids.
- 26 December 2025
- Published by Elsevier in Sustainable Energy, Grids and Networks
- Vol. 45
Low-carbon and robust economic scheduling of virtual power plants considering multiple uncertainties
- 26 December 2025
- Published by Elsevier in Sustainable Energy, Grids and Networks
- Vol. 45
Low-carbon and robust economic scheduling of virtual power plants considering multiple uncertainties
- 3 December 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (1) , 59
Research on icing recognition algorithm for transmission lines based on adaptive frequency domain sensing feature fusion network
- 3 December 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (1) , 59
Research on icing recognition algorithm for transmission lines based on adaptive frequency domain sensing feature fusion network
- Open Access
- 10 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11486
Research on Detection of Icing Cover Transmission Lines Under Different Weather Conditions Based on Wide-Field Dynamic Convolutional Network LDKA-NET
The safety of transmission lines is a crucial guarantee for the operation of the power grid. To address the issue of low detection accuracy for icing transmission line defects with existing models, this paper proposes a defect detection algorithm for icing transmission line defects under different weather conditions based on a Large Dynamic Kernel Aggregation Net (LDKA-NET). First, a wide field of view convolutional network (WFVC Net) is introduced to enhance the network’s perception and generalization capabilities, enabling better adaptation to complex scene targets. Secondly, a full-dimensional dynamic convolutional feature fusion network is proposed, which strengthens the model’s feature extraction ability by learning linear combinations of multiple convolution kernels and their weighted input-related attention. Finally, an Expectation Maximization Dynamic Convolutional Attention (EM-DCA) mechanism is introduced, which focuses on and utilizes important information in the input data to help the model better allocate attention, thereby improving its generalization and robustness. Experimental results show that on the dataset proposed in this paper, the average accuracy of the improved algorithm (mAP@0.5) reaches 99.01%. The model parameters decreased by 47.7 M compared with the baseline model and 91.26 M compared with the Faster region with CNN feature (Faster R-CNN) model. The accuracy is 4.81% and 3.11% higher than the SSD model and YOLOv5-L model, respectively. Compared with the existing models, our model is smaller and has higher detection accuracy. It can accurately detect ice-covered wires and complete the task of the ice-covered detection of transmission lines.
- 10 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11486
Open AccessResearch on Detection of Icing Cover Transmission Lines Under Different Weather Conditions Based on Wide-Field Dynamic Convolutional Network LDKA-NET
The safety of transmission lines is a crucial guarantee for the operation of the power grid. To address the issue of low detection accuracy for icing transmission line defects with existing models, this paper proposes a defect detection algorithm for icing transmission line defects under different weather conditions based on a Large Dynamic Kernel Aggregation Net (LDKA-NET). First, a wide field of view convolutional network (WFVC Net) is introduced to enhance the network’s perception and generalization capabilities, enabling better adaptation to complex scene targets. Secondly, a full-dimensional dynamic convolutional feature fusion network is proposed, which strengthens the model’s feature extraction ability by learning linear combinations of multiple convolution kernels and their weighted input-related attention. Finally, an Expectation Maximization Dynamic Convolutional Attention (EM-DCA) mechanism is introduced, which focuses on and utilizes important information in the input data to help the model better allocate attention, thereby improving its generalization and robustness. Experimental results show that on the dataset proposed in this paper, the average accuracy of the improved algorithm (mAP@0.5) reaches 99.01%. The model parameters decreased by 47.7 M compared with the baseline model and 91.26 M compared with the Faster region with CNN feature (Faster R-CNN) model. The accuracy is 4.81% and 3.11% higher than the SSD model and YOLOv5-L model, respectively. Compared with the existing models, our model is smaller and has higher detection accuracy. It can accurately detect ice-covered wires and complete the task of the ice-covered detection of transmission lines.
- Open Access
- 19 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (22) , 10701
Phase Risk Analysis of Overhead Lines Under Complex Icing Conditions
Phase-to-ground discharge of transmission lines due to ice cover is a common issue. To assess the risk of phase-to-ground discharge of overhead lines under complex ice-covering conditions, this study used finite element analysis to model the interaction between ground wire, conductor, and insulator. The study examined how different factors affect the minimum safe distance between the conductor and ground wire, as well as the risk coefficient of phase-to-ground discharge and the risk zone. The finding reveals that as icing thickness increases, conductor bouncing intensifies, reducing the phase-to-ground distance, and placing one half of the line span within the risk zone for the given conditions. For the same length of de-icing, the closer the de-icing region is to the midpoint, the greater is the maximum jump height of the conductor. When the span is extended to 600 m, the risk range covers approximately 70% of the total line length. Under strong winds, conductor lateral displacement increases with wind speed, which leads to a higher risk of discharge.
- 19 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (22) , 10701
Open AccessPhase Risk Analysis of Overhead Lines Under Complex Icing Conditions
Phase-to-ground discharge of transmission lines due to ice cover is a common issue. To assess the risk of phase-to-ground discharge of overhead lines under complex ice-covering conditions, this study used finite element analysis to model the interaction between ground wire, conductor, and insulator. The study examined how different factors affect the minimum safe distance between the conductor and ground wire, as well as the risk coefficient of phase-to-ground discharge and the risk zone. The finding reveals that as icing thickness increases, conductor bouncing intensifies, reducing the phase-to-ground distance, and placing one half of the line span within the risk zone for the given conditions. For the same length of de-icing, the closer the de-icing region is to the midpoint, the greater is the maximum jump height of the conductor. When the span is extended to 600 m, the risk range covers approximately 70% of the total line length. Under strong winds, conductor lateral displacement increases with wind speed, which leads to a higher risk of discharge.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Research on transformer fault diagnosis models with feature extraction
To address the challenge of low accuracy in traditional transformer fault diagnosis algorithms, this paper introduces a novel approach that utilizes the Artificial Hummingbird Algorithm (AHA) to optimize both Kernel Principal Component Analysis (KPCA) and Extreme Learning Machine (ELM). We propose the use of various gas concentration ratio features and apply the AHA algorithm to fine-tune the kernel function parameters of KPCA, thus establishing an AHA-KPCA feature extraction model. This model takes the expanded gas concentration ratio features as input and selects the top N principal components with a cumulative contribution rate above 95% to form the feature vectors for fault classification. Following this, the AHA algorithm is employed to optimize the input weights and hidden layer biases of the ELM, leading to the development of the AHA-ELM fault classification model. Ultimately, the principal components identified by AHA-KPCA serve as inputs for the simulation verification of the AHA-ELM model. Experimental results indicate that the proposed AHA-KPCA-ELM method attains an accuracy rate of 95.73%, surpassing traditional intelligent diagnostic methods and existing advanced algorithms, thereby confirming the effectiveness of our proposed method.
- 1 November 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (11)
Research on transformer fault diagnosis models with feature extraction
To address the challenge of low accuracy in traditional transformer fault diagnosis algorithms, this paper introduces a novel approach that utilizes the Artificial Hummingbird Algorithm (AHA) to optimize both Kernel Principal Component Analysis (KPCA) and Extreme Learning Machine (ELM). We propose the use of various gas concentration ratio features and apply the AHA algorithm to fine-tune the kernel function parameters of KPCA, thus establishing an AHA-KPCA feature extraction model. This model takes the expanded gas concentration ratio features as input and selects the top N principal components with a cumulative contribution rate above 95% to form the feature vectors for fault classification. Following this, the AHA algorithm is employed to optimize the input weights and hidden layer biases of the ELM, leading to the development of the AHA-ELM fault classification model. Ultimately, the principal components identified by AHA-KPCA serve as inputs for the simulation verification of the AHA-ELM model. Experimental results indicate that the proposed AHA-KPCA-ELM method attains an accuracy rate of 95.73%, surpassing traditional intelligent diagnostic methods and existing advanced algorithms, thereby confirming the effectiveness of our proposed method.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-18
FusionNet: Detection of Foreign Objects in Transmission Lines During Inclement Weather
To address the low accuracy and moderate speed of traditional foreign object detection in transmission line image inspection, the FusionNet is proposed based foreign object detection algorithm in severe weather. First, the FB module(Fusion Block) is proposed in this algorithm, combined with the CA attention(Coordinate Attention) mechanism and the Hardswish activation function, so that the network can increase the learning of the location information based on the attention on the overall classification information, and reduce the network parameters. Then, based on FasterNet, the FSB module (Fusion Speed Block)is proposed to extract the space more efficiently. In addition, the FMB module(Fusion Memory Block) is proposed, which makes full use of the accumulated information in the past to extract more accurate and abundant features. Finally, the utilization of EfficiCIoU as a loss function serves to expedite model convergence and enhance detection precision. Experimental results show that on the dataset in this paper, the improved algorithm mAP@0.5 reaches 98.27%, the model parameters are reduced by 130.42M compared with the Faster-RCNN model, and the accuracy is improved by 19.62% and 4.63% compared with SSD and YOLOv7 models, respectively. The performance on the China Power Line Insulator Dataset (CPLID) is also excellent, reaching 99.17% mAP@0.5, an improvement of 1.85% compared with the baseline model. Compared to the existing models, the FusionNet model is smaller in size and has higher detection accuracy. It can accurately detect targets in inclement weather and perform the task of foreign body detection in transmission lines.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-18
FusionNet: Detection of Foreign Objects in Transmission Lines During Inclement Weather
To address the low accuracy and moderate speed of traditional foreign object detection in transmission line image inspection, the FusionNet is proposed based foreign object detection algorithm in severe weather. First, the FB module(Fusion Block) is proposed in this algorithm, combined with the CA attention(Coordinate Attention) mechanism and the Hardswish activation function, so that the network can increase the learning of the location information based on the attention on the overall classification information, and reduce the network parameters. Then, based on FasterNet, the FSB module (Fusion Speed Block)is proposed to extract the space more efficiently. In addition, the FMB module(Fusion Memory Block) is proposed, which makes full use of the accumulated information in the past to extract more accurate and abundant features. Finally, the utilization of EfficiCIoU as a loss function serves to expedite model convergence and enhance detection precision. Experimental results show that on the dataset in this paper, the improved algorithm mAP@0.5 reaches 98.27%, the model parameters are reduced by 130.42M compared with the Faster-RCNN model, and the accuracy is improved by 19.62% and 4.63% compared with SSD and YOLOv7 models, respectively. The performance on the China Power Line Insulator Dataset (CPLID) is also excellent, reaching 99.17% mAP@0.5, an improvement of 1.85% compared with the baseline model. Compared to the existing models, the FusionNet model is smaller in size and has higher detection accuracy. It can accurately detect targets in inclement weather and perform the task of foreign body detection in transmission lines.
- Open Access
- 18 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4285
Study on the Bouncing Process Induced by Ice Shedding on Overhead Conductors under Strong Wind Conditions
Strong winds can lead to more complex ice shedding oscillation processes for overhead conductors, inducing flashovers, strand breakages and other accidents. This study analyzes the aerodynamic parameters of several typical icing features and establishes a numerical model for ice shedding on overhead conductors under strong wind conditions. The results show that for the same amount of icing, the resistance and lift force on the conductor changes with ice shape, wind attack angle and wind speed, which has a significant effect on the ice shedding jumping process. When the wind attack angle approaches 180°, the airflow resistance of the fan-shaped and D-shaped icing conductors significantly increases. And in the process of ice shedding response of transmission lines, the lateral amplitude may exceed 20 m, which increase the discharge risk of horizontally arranged conductors. Moreover, for the significant lateral oscillation of conductors by ice shedding under strong wind, the maximum horizontal displacement is approximately 1.6 times the difference in lateral position before and after ice shedding.
- 18 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4285
Open AccessStudy on the Bouncing Process Induced by Ice Shedding on Overhead Conductors under Strong Wind Conditions
Strong winds can lead to more complex ice shedding oscillation processes for overhead conductors, inducing flashovers, strand breakages and other accidents. This study analyzes the aerodynamic parameters of several typical icing features and establishes a numerical model for ice shedding on overhead conductors under strong wind conditions. The results show that for the same amount of icing, the resistance and lift force on the conductor changes with ice shape, wind attack angle and wind speed, which has a significant effect on the ice shedding jumping process. When the wind attack angle approaches 180°, the airflow resistance of the fan-shaped and D-shaped icing conductors significantly increases. And in the process of ice shedding response of transmission lines, the lateral amplitude may exceed 20 m, which increase the discharge risk of horizontally arranged conductors. Moreover, for the significant lateral oscillation of conductors by ice shedding under strong wind, the maximum horizontal displacement is approximately 1.6 times the difference in lateral position before and after ice shedding.
- 9 May 2024
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 21 (3) , 1-19
DRI-Net: a model for insulator defect detection on transmission lines in rainy backgrounds
- 9 May 2024
- Published by Springer Nature in Journal of Real-Time Image Processing
- Vol. 21 (3) , 1-19
DRI-Net: a model for insulator defect detection on transmission lines in rainy backgrounds