Yi Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yi Tian has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Xinbo Huang
Xi’an Polytechnic University
10 shared publications - Shengtao Li
Xi'an Jiaotong University
4 shared publications - Yongcan Zhu
Xi’an Polytechnic University, Xi’an, China
4 shared publications Feiyue Ma
3 shared publicationsHaonan Shi
Xi’an Key Laboratory of Interconnected Sensing and Intelligent Diagnosis for Electrical Equipment, Xi’an Polytechnic University, Xi’an 710048, Shaanxi, People’s Republic of China
3 shared publications- Xinsheng Lu
Department of Electronics and Information, Xian Polytechnic University, Xian, China
3 shared publications
Latest Publications
- Open Access
Investigation into Combined AC–DC Insulation Stress Evolution Mechanism and Combined Withstand Voltage Test Method for 40.5 kV Capacitor Bank Circuit Breaker Breaks
With the large-scale construction of renewable energy collection stations and distribution networks, the frequent switching of 40.5 kV reactive power compensation capacitor banks has become a routine operation. To accurately evaluate the insulation safety risk at the breaker break during the switching process of 40.5 kV capacitor bank circuit breakers, this paper comparatively investigates the dynamic transient processes and electric field evolution laws under four typical operating conditions: normal opening/closing, electrode plate short-circuit, non-synchronous opening/closing, and arc restriking. The microscopic failure mechanism under combined AC–DC stress is revealed, and a physical-equivalent combined AC–DC withstand voltage test scheme is proposed and experimentally validated. The results indicate that arc restriking introduces a secondary strong excitation during the unattenuated transient period, causing a surge in overvoltage on the capacitor side, making it the most severe condition inducing transient insulation degradation at the break. Insulation risk evaluation must be grounded on the true instantaneous potential difference between both sides of the break. Under the arc restriking condition, the voltages on both sides exhibit strong opposite-polarity superposition, resulting in a peak instantaneous potential difference of up to 129.0806 kV (busbar side: −49.4861 kV; capacitor side: +79.5945 kV), which substantially exceeds the 1 min power-frequency withstand voltage standard value (118 kV based on IEC 62271-100) for 40.5 kV circuit breaker breaks. Three-dimensional electrostatic field and space charge simulations further reveal the microscopic failure mechanism: under combined AC–DC stress, unipolar free charges undergo directional migration and steady-state accumulation at defects such as micro-protrusions on the contact surface on the DC residual voltage side, forming local high electric field regions and inducing field emission—an effect that cannot be effectively excited in traditional pure AC tests. Consequently, the non-physical extreme value superposition method is abandoned, and a combined AC–DC withstand voltage testing scheme comprising “AC power-frequency −49.4861 kV (peak) and DC +79.5945 kV” is recommended. This study provides deep theoretical insights and numerical evidence for evaluating the insulation margin and revising the type test standards of reactive power compensation circuit breaker breaks.
Open AccessInvestigation into Combined AC–DC Insulation Stress Evolution Mechanism and Combined Withstand Voltage Test Method for 40.5 kV Capacitor Bank Circuit Breaker Breaks
With the large-scale construction of renewable energy collection stations and distribution networks, the frequent switching of 40.5 kV reactive power compensation capacitor banks has become a routine operation. To accurately evaluate the insulation safety risk at the breaker break during the switching process of 40.5 kV capacitor bank circuit breakers, this paper comparatively investigates the dynamic transient processes and electric field evolution laws under four typical operating conditions: normal opening/closing, electrode plate short-circuit, non-synchronous opening/closing, and arc restriking. The microscopic failure mechanism under combined AC–DC stress is revealed, and a physical-equivalent combined AC–DC withstand voltage test scheme is proposed and experimentally validated. The results indicate that arc restriking introduces a secondary strong excitation during the unattenuated transient period, causing a surge in overvoltage on the capacitor side, making it the most severe condition inducing transient insulation degradation at the break. Insulation risk evaluation must be grounded on the true instantaneous potential difference between both sides of the break. Under the arc restriking condition, the voltages on both sides exhibit strong opposite-polarity superposition, resulting in a peak instantaneous potential difference of up to 129.0806 kV (busbar side: −49.4861 kV; capacitor side: +79.5945 kV), which substantially exceeds the 1 min power-frequency withstand voltage standard value (118 kV based on IEC 62271-100) for 40.5 kV circuit breaker breaks. Three-dimensional electrostatic field and space charge simulations further reveal the microscopic failure mechanism: under combined AC–DC stress, unipolar free charges undergo directional migration and steady-state accumulation at defects such as micro-protrusions on the contact surface on the DC residual voltage side, forming local high electric field regions and inducing field emission—an effect that cannot be effectively excited in traditional pure AC tests. Consequently, the non-physical extreme value superposition method is abandoned, and a combined AC–DC withstand voltage testing scheme comprising “AC power-frequency −49.4861 kV (peak) and DC +79.5945 kV” is recommended. This study provides deep theoretical insights and numerical evidence for evaluating the insulation margin and revising the type test standards of reactive power compensation circuit breaker breaks.
- Open Access
- 1 September 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (9)
Mitigating dynamic insulation breakdown in iced overhead ground lines: A differentiated dielectric shielding method with sequential electro-mechanical coupling analysis
In regions prone to severe icing, the nonlinear spatial galloping of overhead transmission lines can induce dynamic instability in conductor-to-ground wire clearances, leading to transient insulation breakdown. To address this dynamic dielectric failure mechanism, this paper proposes a novel differentiated insulation protection strategy that, for the first time, integrates explicit dynamic clearance analysis with electrostatic field computation to establish a spatial risk-zoning framework for overhead ground wires. Initially, a detailed explicit dynamic model of a 110 kV tower-line coupled system is constructed to elucidate the spatial risk evolution of ice-shedding induced transient responses; the resulting time-varying clearances are then subsequently fed into a dynamic gas–solid composite dielectric electric field model that is established to clarify the electric field distortion and ionization mechanism, where local field strength surges to 3.9 kV/mm (exceeding the air breakdown threshold) under critical micro-gap conditions. It is demonstrated that a 4–6 mm silicone rubber coating effectively suppresses the electric field to a safe margin through dielectric shielding by reconfiguring the interfacial capacitance distribution. Based on these findings, an adaptive gradient coating scheme is devised, assigning 6 mm full-arc, 5 mm semi-arc, and 4 mm partial coatings to high, medium, and low-risk sections, respectively, thereby optimizing both insulation resilience and material efficiency. Full-scale power frequency withstand voltage tests conclusively validate this mechanism, showing a substantial 47.26% increase in breakdown voltage under the extreme 1.9 m critical condition. This research provides a rigorous theoretical framework and an engineering paradigm rooted in sequential electro-mechanical coupling for proactive defense against transient electrical faults in power grids.
- 1 September 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (9)
Open AccessMitigating dynamic insulation breakdown in iced overhead ground lines: A differentiated dielectric shielding method with sequential electro-mechanical coupling analysis
In regions prone to severe icing, the nonlinear spatial galloping of overhead transmission lines can induce dynamic instability in conductor-to-ground wire clearances, leading to transient insulation breakdown. To address this dynamic dielectric failure mechanism, this paper proposes a novel differentiated insulation protection strategy that, for the first time, integrates explicit dynamic clearance analysis with electrostatic field computation to establish a spatial risk-zoning framework for overhead ground wires. Initially, a detailed explicit dynamic model of a 110 kV tower-line coupled system is constructed to elucidate the spatial risk evolution of ice-shedding induced transient responses; the resulting time-varying clearances are then subsequently fed into a dynamic gas–solid composite dielectric electric field model that is established to clarify the electric field distortion and ionization mechanism, where local field strength surges to 3.9 kV/mm (exceeding the air breakdown threshold) under critical micro-gap conditions. It is demonstrated that a 4–6 mm silicone rubber coating effectively suppresses the electric field to a safe margin through dielectric shielding by reconfiguring the interfacial capacitance distribution. Based on these findings, an adaptive gradient coating scheme is devised, assigning 6 mm full-arc, 5 mm semi-arc, and 4 mm partial coatings to high, medium, and low-risk sections, respectively, thereby optimizing both insulation resilience and material efficiency. Full-scale power frequency withstand voltage tests conclusively validate this mechanism, showing a substantial 47.26% increase in breakdown voltage under the extreme 1.9 m critical condition. This research provides a rigorous theoretical framework and an engineering paradigm rooted in sequential electro-mechanical coupling for proactive defense against transient electrical faults in power grids.
- Open Access
- 21 March 2026
- Published by Elsevier in SSRN Electronic Journal
Non-invasive Transient Sensing of High Voltage Circuit Breakers Based on PVDF/GMM MEMS and Adaptive Topology Reconstruction
Ensuring the stability of supply voltage and frequency is a fundamental requirement for power system operation. To meet the dynamic demands of reactive power compensation, frequent switching of capacitor bank circuit breakers is essential. However, the resulting arc erosion and mechanical wear degrade arc-extinguishing performance, posing significant threats to grid security. To address the limitations of existing monitoring methods in balancing miniaturization, wide bandwidth, and non-intrusive measurement, this paper proposes a transient voltage and current monitoring solution based on non-intrusive Micro-Electro-Mechanical Systems (MEMS) sensing technology. Firstly, an electro-optical/magneto-optical thin-film MEMS sensor was developed using a layered PVDF fabrication process and a multi-layer conjugate compensation mechanism. Combined with an orthogonal correlation demodulation algorithm, background noise was effectively suppressed, achieving the miniaturized fabrication of high-sensitivity sensing chips. Secondly, to address the challenge of unknown spatial coupling parameters, an adaptive topology reconstruction readout circuit was designed. By actively changing the impedance structure of the measurement circuit and introducing independent equation constraints, the unknown coupling parameters were mathematically decoupled and inverted in real-time, achieving a "plug and play" self-calibration measurement. Finally, this article establishes a micro/macro cross scale field circuit coupling model and designs a snap-on fixing mechanism and high potential measurement insulation scheme suitable for the installation of circuit breaker drainage lines. The experimental results show that the system not only has the wideband characteristics of MEMS devices, but also effectively solves the calibration problem of non-invasive measurement, providing a highly reliable and low-cost technical solution for the full life cycle state monitoring of circuit breakers.
- 21 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNon-invasive Transient Sensing of High Voltage Circuit Breakers Based on PVDF/GMM MEMS and Adaptive Topology Reconstruction
Ensuring the stability of supply voltage and frequency is a fundamental requirement for power system operation. To meet the dynamic demands of reactive power compensation, frequent switching of capacitor bank circuit breakers is essential. However, the resulting arc erosion and mechanical wear degrade arc-extinguishing performance, posing significant threats to grid security. To address the limitations of existing monitoring methods in balancing miniaturization, wide bandwidth, and non-intrusive measurement, this paper proposes a transient voltage and current monitoring solution based on non-intrusive Micro-Electro-Mechanical Systems (MEMS) sensing technology. Firstly, an electro-optical/magneto-optical thin-film MEMS sensor was developed using a layered PVDF fabrication process and a multi-layer conjugate compensation mechanism. Combined with an orthogonal correlation demodulation algorithm, background noise was effectively suppressed, achieving the miniaturized fabrication of high-sensitivity sensing chips. Secondly, to address the challenge of unknown spatial coupling parameters, an adaptive topology reconstruction readout circuit was designed. By actively changing the impedance structure of the measurement circuit and introducing independent equation constraints, the unknown coupling parameters were mathematically decoupled and inverted in real-time, achieving a "plug and play" self-calibration measurement. Finally, this article establishes a micro/macro cross scale field circuit coupling model and designs a snap-on fixing mechanism and high potential measurement insulation scheme suitable for the installation of circuit breaker drainage lines. The experimental results show that the system not only has the wideband characteristics of MEMS devices, but also effectively solves the calibration problem of non-invasive measurement, providing a highly reliable and low-cost technical solution for the full life cycle state monitoring of circuit breakers.
- Open Access
- 28 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2400
Research on Ultrasonic Imaging of Defects in Insulating Materials Based on the SAFT
As a critical barrier for power network safety, insulating materials are susceptible to internal microcracks, delamination, and other hidden defects that can trigger dielectric strength degradation and space charge accumulation, ultimately leading to insulation breakdown. Ultrasonic shear wave non-destructive testing enables defect identification without damaging the material. Therefore, this paper focuses on the identification and imaging of internal defects in insulating components using ultrasonic shear waves. First, a physical model for ultrasonic shear wave NDT is established. Based on the refraction and reflection characteristics of ultrasonic waves in materials with different acoustic impedances, a defect localization formula is derived. Through simulation verification, for the three defects set at different positions in the defect model, the positioning error is less than 0.5 mm. Subsequently, defects such as circular holes, triangular shapes, cracks, and bottom grooves were simulated. Analysis of the echo data revealed a correlation between the distance from the sensor to the defect and the echo amplitude. For groove defect imaging, the differential SAFT algorithm was employed, achieving a width error of 1 mm for imaging a 2 mm wide by 5 mm high groove, clearly presenting the defect morphology. Finally, an imaging software program for defect structure reconstruction was developed based on the simulation model presented in this article. We collected side and back view data through the constructed ultrasonic transverse wave non-destructive testing experimental platform, and visualized defects in insulation materials with grooves using this ultrasonic imaging program. This study achieved defect localization and imaging through simulation of various defect types combined with synthetic aperture focused imaging algorithms, providing a reference for visualization and industrial application of ultrasonic shear wave non-destructive testing technology.
- 28 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2400
Open AccessResearch on Ultrasonic Imaging of Defects in Insulating Materials Based on the SAFT
As a critical barrier for power network safety, insulating materials are susceptible to internal microcracks, delamination, and other hidden defects that can trigger dielectric strength degradation and space charge accumulation, ultimately leading to insulation breakdown. Ultrasonic shear wave non-destructive testing enables defect identification without damaging the material. Therefore, this paper focuses on the identification and imaging of internal defects in insulating components using ultrasonic shear waves. First, a physical model for ultrasonic shear wave NDT is established. Based on the refraction and reflection characteristics of ultrasonic waves in materials with different acoustic impedances, a defect localization formula is derived. Through simulation verification, for the three defects set at different positions in the defect model, the positioning error is less than 0.5 mm. Subsequently, defects such as circular holes, triangular shapes, cracks, and bottom grooves were simulated. Analysis of the echo data revealed a correlation between the distance from the sensor to the defect and the echo amplitude. For groove defect imaging, the differential SAFT algorithm was employed, achieving a width error of 1 mm for imaging a 2 mm wide by 5 mm high groove, clearly presenting the defect morphology. Finally, an imaging software program for defect structure reconstruction was developed based on the simulation model presented in this article. We collected side and back view data through the constructed ultrasonic transverse wave non-destructive testing experimental platform, and visualized defects in insulation materials with grooves using this ultrasonic imaging program. This study achieved defect localization and imaging through simulation of various defect types combined with synthetic aperture focused imaging algorithms, providing a reference for visualization and industrial application of ultrasonic shear wave non-destructive testing technology.
- 17 January 2026
- Published by Springer Nature
- p. 458-467
Finite Element Simulation Analysis on Buffer Layer Discharge for High-Voltage XLPE Cable
- 17 January 2026
- Published by Springer Nature
- p. 458-467
Finite Element Simulation Analysis on Buffer Layer Discharge for High-Voltage XLPE Cable
- Open Access
- 26 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (5) , 2538
Research on Online Monitoring of Partial Discharge of Insulation Defects in Air Switchgear Based on Characteristic Gases
Air switchgear is an important power equipment in the transmission, transformation, and distribution process of the power system. Insulation defects can lead to partial discharge, which is one of the primary causes of air switchgear failure. Current monitoring methods primarily rely on detecting ultra-high frequency or ultrasonic signals generated by partial discharge to identify insulation defects. However, these methods are prone to external signal interference, resulting in substantial detection errors. Based on gas discharge theory and engineering practice, this paper uses three typical defects to represent the main insulation defects of air switchgear, namely metal protrusion defects, insulation layer air gap defects, and metal particle defects. After that, the validity of the numerical model to describe the partial discharge process of air switchgear insulation defects is verified by the volt-ampere characteristic curve. The discharge process of three typical defect models was investigated by using the numerical model, and the variation curves of the volume fractions of CO, NO2, and O3 gases at different voltage levels and different discharge durations were obtained. After analysis, the volume fractions of the three characteristic gases are unique under different defect models and partial discharge quantities. Finally, this paper designed a partial discharge inversion method based on characteristic gases, and fitted time-domain regression equations and partial discharge inversion regression equations based on the changes in volume fractions of the three characteristic gases measured. The research results of this paper provide a theoretical basis for online detection of partial discharge in high-voltage air switchgear through characteristic gases. The method proposed in this paper can also be applied to other gas-insulated equipment, such as GIS, metal-enclosed switchgear, and vacuum circuit breakers.
- 26 February 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (5) , 2538
Open AccessResearch on Online Monitoring of Partial Discharge of Insulation Defects in Air Switchgear Based on Characteristic Gases
Air switchgear is an important power equipment in the transmission, transformation, and distribution process of the power system. Insulation defects can lead to partial discharge, which is one of the primary causes of air switchgear failure. Current monitoring methods primarily rely on detecting ultra-high frequency or ultrasonic signals generated by partial discharge to identify insulation defects. However, these methods are prone to external signal interference, resulting in substantial detection errors. Based on gas discharge theory and engineering practice, this paper uses three typical defects to represent the main insulation defects of air switchgear, namely metal protrusion defects, insulation layer air gap defects, and metal particle defects. After that, the validity of the numerical model to describe the partial discharge process of air switchgear insulation defects is verified by the volt-ampere characteristic curve. The discharge process of three typical defect models was investigated by using the numerical model, and the variation curves of the volume fractions of CO, NO2, and O3 gases at different voltage levels and different discharge durations were obtained. After analysis, the volume fractions of the three characteristic gases are unique under different defect models and partial discharge quantities. Finally, this paper designed a partial discharge inversion method based on characteristic gases, and fitted time-domain regression equations and partial discharge inversion regression equations based on the changes in volume fractions of the three characteristic gases measured. The research results of this paper provide a theoretical basis for online detection of partial discharge in high-voltage air switchgear through characteristic gases. The method proposed in this paper can also be applied to other gas-insulated equipment, such as GIS, metal-enclosed switchgear, and vacuum circuit breakers.
- 7 June 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (9) , 095004
Research on infrared spectroscopy detection of furfural content in transformer oil based on acetonitrile extraction
The stable operation of power transformers depends on the oil-paper insulation system, in which the aging degree of insulating paper is the key to evaluate the remaining life of the transformer. Currently, methanol extraction is widely used to detect the furfural content in oil to evaluate the aging state of insulating paper, but it ignores the influence of methanol produced during the operation of the transformer on the extraction results. To address this issue, this paper proposes a new method that can replace methanol extraction for detecting furfural in oil through simulation and experiment. Firstly, through simulation and experiment, it is proved that the strong vibration absorption peaks at 1677 cm−1 for furfural carbonyl and 2240 cm−1 for acetonitrile cyano can be used to establish a new method for extracting furfural content in oil using acetonitrile. A quantitative model between the concentration x of furfural in the furfural-acetonitrile mixed solution and the area y of the infrared absorption peak at 1677 cm−1 is established, with a goodness of fit of 0.9974. Secondly, a comparison between direct detection and acetonitrile extraction methods is conducted. The results show that direct detection is simple to operate, but the minimum detection concentration is 40 mg l−1, which is difficult to meet practical requirements. Acetonitrile extraction can reduce the minimum detection concentration to 0.1 mg l−1. At the same time, the extraction conditions are analyzed to determine the extraction ratio of 30, extraction times of 5, and extraction rate of 60%. Finally, the proposed detection method is applied to thermal aging tests on insulating paper of different types. The experimental results show that the proposed method has good repeatability and improves the detection resolution of furfural content. This paper combines infrared spectroscopy with acetonitrile extraction technology to open up a more efficient and practical new method for detecting furfural content in transformer oil.
- 7 June 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (9) , 095004
Research on infrared spectroscopy detection of furfural content in transformer oil based on acetonitrile extraction
The stable operation of power transformers depends on the oil-paper insulation system, in which the aging degree of insulating paper is the key to evaluate the remaining life of the transformer. Currently, methanol extraction is widely used to detect the furfural content in oil to evaluate the aging state of insulating paper, but it ignores the influence of methanol produced during the operation of the transformer on the extraction results. To address this issue, this paper proposes a new method that can replace methanol extraction for detecting furfural in oil through simulation and experiment. Firstly, through simulation and experiment, it is proved that the strong vibration absorption peaks at 1677 cm−1 for furfural carbonyl and 2240 cm−1 for acetonitrile cyano can be used to establish a new method for extracting furfural content in oil using acetonitrile. A quantitative model between the concentration x of furfural in the furfural-acetonitrile mixed solution and the area y of the infrared absorption peak at 1677 cm−1 is established, with a goodness of fit of 0.9974. Secondly, a comparison between direct detection and acetonitrile extraction methods is conducted. The results show that direct detection is simple to operate, but the minimum detection concentration is 40 mg l−1, which is difficult to meet practical requirements. Acetonitrile extraction can reduce the minimum detection concentration to 0.1 mg l−1. At the same time, the extraction conditions are analyzed to determine the extraction ratio of 30, extraction times of 5, and extraction rate of 60%. Finally, the proposed detection method is applied to thermal aging tests on insulating paper of different types. The experimental results show that the proposed method has good repeatability and improves the detection resolution of furfural content. This paper combines infrared spectroscopy with acetonitrile extraction technology to open up a more efficient and practical new method for detecting furfural content in transformer oil.
- 20 January 2024
- Published by Springer Nature
- p. 31-42
Study on the Surface Charge Accumulation and Dispersion Process of Polyimide for New Cables
- 20 January 2024
- Published by Springer Nature
- p. 31-42
Study on the Surface Charge Accumulation and Dispersion Process of Polyimide for New Cables
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 83-92
Study of Electrostatic Motion Behavior and Inhibition of Metallic Particles in GIS/GIL
The most frequent insulation defect appears to be the presence of small amounts of spherical, linear, and other shapes of micro metallic particles in Gas Insulated Switchgear (GIS) and Gas Insulated Transmission Line (GIL). It poses a major risk for partial discharge if the metallic particles travel to the location with a high field strength. The study to inhibit the movement of metal particles and thus solve the issue of metallic particle contamination is the key technical challenge to effectively improve the insulation strength. In this article, we present a mathematical-physical model applicable to the real structure with complex electric field and various types of particles using the finite element method (FEM) and the differential element method (DEM). This study shows that the asymmetry of the electrostatic force caused by the asymmetry of the particle shape is the main cause of the complex motion behavior. The model can predict several unique occurrences, including the one-sided lifting of longer linear particles, and our experiments have confirmed these predictions. The method of dielectric coating for particle motion inhibition is investigated, and a significant inhibition effect is observed as the lift-off voltage of the particles is dramatically increased.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (1) , 83-92
Study of Electrostatic Motion Behavior and Inhibition of Metallic Particles in GIS/GIL
The most frequent insulation defect appears to be the presence of small amounts of spherical, linear, and other shapes of micro metallic particles in Gas Insulated Switchgear (GIS) and Gas Insulated Transmission Line (GIL). It poses a major risk for partial discharge if the metallic particles travel to the location with a high field strength. The study to inhibit the movement of metal particles and thus solve the issue of metallic particle contamination is the key technical challenge to effectively improve the insulation strength. In this article, we present a mathematical-physical model applicable to the real structure with complex electric field and various types of particles using the finite element method (FEM) and the differential element method (DEM). This study shows that the asymmetry of the electrostatic force caused by the asymmetry of the particle shape is the main cause of the complex motion behavior. The model can predict several unique occurrences, including the one-sided lifting of longer linear particles, and our experiments have confirmed these predictions. The method of dielectric coating for particle motion inhibition is investigated, and a significant inhibition effect is observed as the lift-off voltage of the particles is dramatically increased.
- 7 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (5) , 3602-3610
Electrostatic Attraction Mechanism of Metallic Particles
Free metallic particle defect is more harmful in gas-insulated switchgear (GIS) and gas-insulated transmission line (GIL). GIS/GIL has a compact structure and is more sensitive to inhomogeneous electric fields. Metallic particles will be attracted in the presence of the electric field, narrowing the gas gap and causing partial discharge. However, the precise mechanism of the electrostatic attraction process is not fully understood. This study shows that the induced electrification process of particles is accompanied by a photon emission phenomenon, of which the precise charge quantity can be calculated with our newly introduced apparent dielectric constant. Metallic particles are equipotential in the electrification process, and their shapes, especially the sharp edges, significantly affect the electrostatic attraction of the lift-off process. The study found that electric field distortion caused by charged metallic particles can also affect the movement of particles, noting that the inhomogeneity of the particle shape leads to inhomogeneity of the electrostatic loading, making the direct derivation of particle properties from the lift-off voltage almost impossible. The results of this work yield quantitatively reliable conclusions, and may pave the way for additional sophisticated studies on electrical simulation and engineering practice.
- 7 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (5) , 3602-3610
Electrostatic Attraction Mechanism of Metallic Particles
Free metallic particle defect is more harmful in gas-insulated switchgear (GIS) and gas-insulated transmission line (GIL). GIS/GIL has a compact structure and is more sensitive to inhomogeneous electric fields. Metallic particles will be attracted in the presence of the electric field, narrowing the gas gap and causing partial discharge. However, the precise mechanism of the electrostatic attraction process is not fully understood. This study shows that the induced electrification process of particles is accompanied by a photon emission phenomenon, of which the precise charge quantity can be calculated with our newly introduced apparent dielectric constant. Metallic particles are equipotential in the electrification process, and their shapes, especially the sharp edges, significantly affect the electrostatic attraction of the lift-off process. The study found that electric field distortion caused by charged metallic particles can also affect the movement of particles, noting that the inhomogeneity of the particle shape leads to inhomogeneity of the electrostatic loading, making the direct derivation of particle properties from the lift-off voltage almost impossible. The results of this work yield quantitatively reliable conclusions, and may pave the way for additional sophisticated studies on electrical simulation and engineering practice.