S. D. Varzhapetian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
S. D. Varzhapetian has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Tеtyana Strogonova
Запорізький державний медико-фармацевтичний університет, Україна
3 shared publications - M. A. Shyshkin
Запорізький державний медико-фармацевтичний університет, Україна
2 shared publications - O. V. Sydor
Zaporizhzhia State Medical and Pharmaceutical University, Zaporizhzhia, Ukraine
2 shared publications - Oleg Mishchenko
Department of Dentistry of Postgraduate Education, Zaporizhzhia State Medical and Pharmaceutical University, 26 Marii Prymachenko Blvd., 69035 Zaporizhzhia, Ukraine
2 shared publications Анатолий Георгиевич Гулюк
ГУ «Институт стоматологи НАМН Украины» ул. Решельевская, 11, г. Одесса, Украина, 65026
2 shared publicationsA.A. Babenya
Institute of Dentistry and Maxillofacial Surgery of the National Academy of Medical Sciences of Ukraine, Rishelevskaya str., 11, Odessa, 65000
1 shared publication
Latest Publications
- Open Access
- 30 September 2024
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Modern medical technology
- Vol. 16 (3) , 206-213
Evaluation of anti-inflammatory properties on the surface of dental implants depending on the type of processing
The aim. Study of the anti-inflammatory properties of the surface of commercial dental implants made of zirconium and titanium with different processing methods using the example of the course of the first stage of implantation. Materials and methods. The structural (microstructure of the surface, biocompatibility, surface corrosion, elemental surface structures) and clinical (severity of peri-implantitis and mucositis, coefficient of implant stability) characteristics of dental implants made of zirconium with surface treatment by the PEO method and implants made of titanium with DAE surface treatment were studied. Median test (χ2), Kruskal–Wallis test (H), univariate variance analysis (F) were used. The difference in parameters was considered statistically significant at the p ≤ 0.05 level. Results. The PEO surface had a monolithic surface layer with rounded pores averaging 4.51 μm2. The DAE surface had a polyhedral irregular shape, about 7–12 μm2. On the DAE surface: carbon – 4.59 wt%, oxygen – 6.16 wt% and traces of zinc were found. A significant difference in the elemental composition of PEO implants was the presence of chlorine (0.93 wt%), silicium (0.14 wt%), aluminum (0.23 wt%), potassium (0.47 wt%) and magnesium (0.07 wt%). The results of comparing the contact angle of the B&B Dental 29.2 ± 5.9° and Zircon-Prior 21.5 ± 3.3° samples had no statistically significant difference (р > 0.05). After 7 days of exposure in the SBF solution, zirconium implants with a PEO surface increased calcium by 21.87 wt%, phosphorus by 35.68 wt%, sodium by 72.89 wt%, and chlorine by 76.21 wt%. Aluminum, silicium, and zinc were no longer detected. The peculiarity of the titanium implant sample with the DAE surface was only the background level of calcium – 0.06 wt% and the complete absence of phosphorus; the most significant components were oxygen – 16.71 wt%, carbon – 12.37 wt%, sodium – 6.47 wt%, and chlorine – 5.90 wt%. Assessment of cell adhesion to the surface of Zircon-Prior and B&B Dental samples neither on the first nor on the seventh day of incubation did not demonstrate a statistically significant difference. Clinical signs of bone tissue resorption were identified around 30.8 % of implants with a PEO surface and 27.3 % of implants with a DAE surface (p = 0.8); inflammation of the mucous membrane – in the areas of installation of 34.6 % of PEO implants and 72.7 % of DAE (p = 0.009). 3.8 % of PEO implants and 9.1 % of DAE implants were lost (p = 0.44). The average ISQ were significantly different: 59.2 ± 4.1 DAE implants versus 64.4 ± 4.9 PEO implants, p = 0.003. Conclusions. Resorption of bone tissue around zirconium implants with a PEO surface (30.8 %) was more common than around titanium implants with DAE surface treatment (27.3 %), p = 0.8. Clinical signs of bacterial damage were more frequent and more severe around DAE-coated implants (72.7 %) than in the areas of PEO implants (34.6 %), p = 0.009. In zirconium implants with surface treatment by the PEO method (64.4 ± 4.9 units), the index of stability (ISQ) was significantly higher than in titanium implants with surface treatment by the DAE method (59.2 ± 4.1 units, p = 0.003). The probability of “loss” of titanium implants with DAE surface treatment (9.1 %) at the surgical stages of implantation is higher than that of zirconium implants with PEO surface treatment (3.8 %, p = 0.44).
- 30 September 2024
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Modern medical technology
- Vol. 16 (3) , 206-213
Open AccessEvaluation of anti-inflammatory properties on the surface of dental implants depending on the type of processing
The aim. Study of the anti-inflammatory properties of the surface of commercial dental implants made of zirconium and titanium with different processing methods using the example of the course of the first stage of implantation. Materials and methods. The structural (microstructure of the surface, biocompatibility, surface corrosion, elemental surface structures) and clinical (severity of peri-implantitis and mucositis, coefficient of implant stability) characteristics of dental implants made of zirconium with surface treatment by the PEO method and implants made of titanium with DAE surface treatment were studied. Median test (χ2), Kruskal–Wallis test (H), univariate variance analysis (F) were used. The difference in parameters was considered statistically significant at the p ≤ 0.05 level. Results. The PEO surface had a monolithic surface layer with rounded pores averaging 4.51 μm2. The DAE surface had a polyhedral irregular shape, about 7–12 μm2. On the DAE surface: carbon – 4.59 wt%, oxygen – 6.16 wt% and traces of zinc were found. A significant difference in the elemental composition of PEO implants was the presence of chlorine (0.93 wt%), silicium (0.14 wt%), aluminum (0.23 wt%), potassium (0.47 wt%) and magnesium (0.07 wt%). The results of comparing the contact angle of the B&B Dental 29.2 ± 5.9° and Zircon-Prior 21.5 ± 3.3° samples had no statistically significant difference (р > 0.05). After 7 days of exposure in the SBF solution, zirconium implants with a PEO surface increased calcium by 21.87 wt%, phosphorus by 35.68 wt%, sodium by 72.89 wt%, and chlorine by 76.21 wt%. Aluminum, silicium, and zinc were no longer detected. The peculiarity of the titanium implant sample with the DAE surface was only the background level of calcium – 0.06 wt% and the complete absence of phosphorus; the most significant components were oxygen – 16.71 wt%, carbon – 12.37 wt%, sodium – 6.47 wt%, and chlorine – 5.90 wt%. Assessment of cell adhesion to the surface of Zircon-Prior and B&B Dental samples neither on the first nor on the seventh day of incubation did not demonstrate a statistically significant difference. Clinical signs of bone tissue resorption were identified around 30.8 % of implants with a PEO surface and 27.3 % of implants with a DAE surface (p = 0.8); inflammation of the mucous membrane – in the areas of installation of 34.6 % of PEO implants and 72.7 % of DAE (p = 0.009). 3.8 % of PEO implants and 9.1 % of DAE implants were lost (p = 0.44). The average ISQ were significantly different: 59.2 ± 4.1 DAE implants versus 64.4 ± 4.9 PEO implants, p = 0.003. Conclusions. Resorption of bone tissue around zirconium implants with a PEO surface (30.8 %) was more common than around titanium implants with DAE surface treatment (27.3 %), p = 0.8. Clinical signs of bacterial damage were more frequent and more severe around DAE-coated implants (72.7 %) than in the areas of PEO implants (34.6 %), p = 0.009. In zirconium implants with surface treatment by the PEO method (64.4 ± 4.9 units), the index of stability (ISQ) was significantly higher than in titanium implants with surface treatment by the DAE method (59.2 ± 4.1 units, p = 0.003). The probability of “loss” of titanium implants with DAE surface treatment (9.1 %) at the surgical stages of implantation is higher than that of zirconium implants with PEO surface treatment (3.8 %, p = 0.44).
- Open Access
- 22 April 2024
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 21 (1) , 14-22
Evaluation of anti-inflammatory properties on the surface of dental implants depending on the type of processing (Part 1)
The aim. To study of the anti-inflammatory properties of the surface of commercial dental implants with different processing methods using the example of the course of the first stage of implantation. Materials and methods. Dental implants made of titanium with 3D Active and Xpeed surface treatment were used. The surface microstructure and biocompatibility of the samples, surface corrosion, elemental analysis of the surface was studied. The assessment of the severity of peri-implantitis and mucositis based on the depth of the peri-implant pocket and bleeding during probing, determination of the coefficient of stability of implants (KSI) is given. Median test (χ2), Kruskel–Wallis test (H), univariate variance analysis (F) were used for multiple comparison of samples. The difference in parameters was considered statistically significant at the p ≤ 0.05 level. Results. The surfaces of 3D Active implants are monolithic with rounded pores in the form of wells of different diameters and depths; the upper layer of the Xpeed sample consists of closely adjacent to each other fragments of a rectangular or polygonal shape, in the form of tiles, leaving rectangular faces on the outside. On the surface of the 3D Active samples, in addition to oxygen and carbon, there was phosphorus – 5.04 wt%, as well as S, Ca, Na, Zr, Zn which weight percentage did not exceed 1 wt%. A significant difference in the elemental composition of Xpeed implants was the presence of chlorine 0.07 wt% and 0.93 wt%, silicon – 0.10 wt% and 0.14 wt%, aluminum 0.06 wt% and 0.23 wt%, respectively, with the latter has a significant advantage in these elements. Xpeed had an insignificant weight percentage of iron in its composition – 0.12 wt%. The assessment of cell adhesion to the surface of the samples on the first day of incubation demonstrated that the samples with the Xpeed and 3D Active surfaces did not have a statistically significant difference between them. Also, on the 7th day of incubation, the level of reduction of resazurin in Xpeed was lower, no significant difference was observed (p > 0.05). The clinical signs of bone tissue resorption were identified in 36.4 % of 3D Active implants and 60.0 % of Xpeed implants (p = 0.3); inflammation of the mucous membrane – in the areas of installation of 54.5 % of 3D Active implants. No signs of mucositis were detected around the Xpeed implants (p = 0.23). 9.1 % of 3D Active implants were “lost”; no cases of loss of Xpeed implants have been identified. The KSI of 3D Active – 64.0 ± 5.9 units, Xpeed – 65.1 ± 3.7 units. Conclusions. According to KSI indicators, titanium implants with Xpeed coating (65.1 ± 3.7 units) and 3D Active (64.0 ± 5.9 units) showed the same capabilities. Bone tissue resorption without signs of inflammation is more common around Xpeed-coated implants than 3D Active-coated implants. Clinical signs of inflammation are more frequent and more severe around implants with a 3D Active coating, which affected both the severity of the course of the first stage of implantation and its results. Xpeed-coated implants are more reliable than 3D Active: loss among 3D Active implants was 9.1 %, Xpeed – 0.0 %. Мета роботи – дослідження антизапальних властивостей поверхні комерційних дентальних імплантатів із різним методом обробки на прикладі перебігу першого етапу імплантації. Матеріали і методи. Використано дентальні імплантати з титану з обробкою поверхні 3D Active і Xpeed. Досліджено мікроструктуру поверхні та біосумісність зразків, корозію поверхні, здійснили елементний аналіз поверхні. Оцінили тяжкість перебігу періімплантиту та мукозиту за глибиною періімплантної кишені та кровотечі при зондуванні; визначили коефіцієнт стабільності імплантатів (КСІ). Для множинного порівняння вибірок використали медіанний тест (χ2), тест Краскела–Волліса (H), однофакторний дисперсійний аналіз (F). Різницю параметрів вважали статистично значущою на рівні p ≤ 0,05. Результати. Поверхня імплантатів 3D Active монолітна, з порами округлої форми – лунками різного діаметра та глибини; верхній шар зразка Xpeed складається з фрагментів прямокутної чи полігональної форми, що щільно прилягають один до одного, як черепиця, залишаючи назовні прямокутні грані. На поверхні зразків 3D Active, крім кисню та вуглецю, виявили фосфор (5,04 ваг%), а також S, Ca, Na, Zr, Zn (≤1,0 ваг%). Суттєва відмінність елементного складу імплантатів Xpeed – наявність хлору (0,07 ваг% проти 0,93 ваг%), силіцію (0,10 ваг% проти 0,14 ваг%), алюмінію (0,06 ваг% проти 0,23 ваг% відповідно), зі значною перевагою за вмістом цих елементів. Xpeed містив незначний ваговий відсоток заліза – 0,12 ваг%. Оцінювання адгезії клітин до поверхні зразків на першу добу інкубації показало, що зразки з поверхнею Xpeed і 3D...
- 22 April 2024
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 21 (1) , 14-22
Open AccessEvaluation of anti-inflammatory properties on the surface of dental implants depending on the type of processing (Part 1)
The aim. To study of the anti-inflammatory properties of the surface of commercial dental implants with different processing methods using the example of the course of the first stage of implantation. Materials and methods. Dental implants made of titanium with 3D Active and Xpeed surface treatment were used. The surface microstructure and biocompatibility of the samples, surface corrosion, elemental analysis of the surface was studied. The assessment of the severity of peri-implantitis and mucositis based on the depth of the peri-implant pocket and bleeding during probing, determination of the coefficient of stability of implants (KSI) is given. Median test (χ2), Kruskel–Wallis test (H), univariate variance analysis (F) were used for multiple comparison of samples. The difference in parameters was considered statistically significant at the p ≤ 0.05 level. Results. The surfaces of 3D Active implants are monolithic with rounded pores in the form of wells of different diameters and depths; the upper layer of the Xpeed sample consists of closely adjacent to each other fragments of a rectangular or polygonal shape, in the form of tiles, leaving rectangular faces on the outside. On the surface of the 3D Active samples, in addition to oxygen and carbon, there was phosphorus – 5.04 wt%, as well as S, Ca, Na, Zr, Zn which weight percentage did not exceed 1 wt%. A significant difference in the elemental composition of Xpeed implants was the presence of chlorine 0.07 wt% and 0.93 wt%, silicon – 0.10 wt% and 0.14 wt%, aluminum 0.06 wt% and 0.23 wt%, respectively, with the latter has a significant advantage in these elements. Xpeed had an insignificant weight percentage of iron in its composition – 0.12 wt%. The assessment of cell adhesion to the surface of the samples on the first day of incubation demonstrated that the samples with the Xpeed and 3D Active surfaces did not have a statistically significant difference between them. Also, on the 7th day of incubation, the level of reduction of resazurin in Xpeed was lower, no significant difference was observed (p > 0.05). The clinical signs of bone tissue resorption were identified in 36.4 % of 3D Active implants and 60.0 % of Xpeed implants (p = 0.3); inflammation of the mucous membrane – in the areas of installation of 54.5 % of 3D Active implants. No signs of mucositis were detected around the Xpeed implants (p = 0.23). 9.1 % of 3D Active implants were “lost”; no cases of loss of Xpeed implants have been identified. The KSI of 3D Active – 64.0 ± 5.9 units, Xpeed – 65.1 ± 3.7 units. Conclusions. According to KSI indicators, titanium implants with Xpeed coating (65.1 ± 3.7 units) and 3D Active (64.0 ± 5.9 units) showed the same capabilities. Bone tissue resorption without signs of inflammation is more common around Xpeed-coated implants than 3D Active-coated implants. Clinical signs of inflammation are more frequent and more severe around implants with a 3D Active coating, which affected both the severity of the course of the first stage of implantation and its results. Xpeed-coated implants are more reliable than 3D Active: loss among 3D Active implants was 9.1 %, Xpeed – 0.0 %. Мета роботи – дослідження антизапальних властивостей поверхні комерційних дентальних імплантатів із різним методом обробки на прикладі перебігу першого етапу імплантації. Матеріали і методи. Використано дентальні імплантати з титану з обробкою поверхні 3D Active і Xpeed. Досліджено мікроструктуру поверхні та біосумісність зразків, корозію поверхні, здійснили елементний аналіз поверхні. Оцінили тяжкість перебігу періімплантиту та мукозиту за глибиною періімплантної кишені та кровотечі при зондуванні; визначили коефіцієнт стабільності імплантатів (КСІ). Для множинного порівняння вибірок використали медіанний тест (χ2), тест Краскела–Волліса (H), однофакторний дисперсійний аналіз (F). Різницю параметрів вважали статистично значущою на рівні p ≤ 0,05. Результати. Поверхня імплантатів 3D Active монолітна, з порами округлої форми – лунками різного діаметра та глибини; верхній шар зразка Xpeed складається з фрагментів прямокутної чи полігональної форми, що щільно прилягають один до одного, як черепиця, залишаючи назовні прямокутні грані. На поверхні зразків 3D Active, крім кисню та вуглецю, виявили фосфор (5,04 ваг%), а також S, Ca, Na, Zr, Zn (≤1,0 ваг%). Суттєва відмінність елементного складу імплантатів Xpeed – наявність хлору (0,07 ваг% проти 0,93 ваг%), силіцію (0,10 ваг% проти 0,14 ваг%), алюмінію (0,06 ваг% проти 0,23 ваг% відповідно), зі значною перевагою за вмістом цих елементів. Xpeed містив незначний ваговий відсоток заліза – 0,12 ваг%. Оцінювання адгезії клітин до поверхні зразків на першу добу інкубації показало, що зразки з поверхнею Xpeed і 3D...
- Open Access
- 22 December 2023
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 20 (3) , 266-270
Correlation of bone density of individual jaw sections according to Hounsfield with the length of the adentiary section in the cone-beam computer tomography program
Aim. To study the existence of a relationship between the density of bone tissue and the length of the edentulous part of the tooth row. Materials and methods. Evaluation of the density of the spongy substance of the jaws by the maximum and average value of HU. The density of cancellous bone was evaluated only in the areas available for implant placement. The groups consisted of the localization and extent of the dentition defect. Statistical methods included the estimation of the arithmetic mean (M), standard deviation (σ), error of the mean (m), confidence interval (95 % CI), estimation of the median (Me) and interquartile range ([Q1; Q2]), Student’s test (t criterion). Results. Maximum and average indicators of cancellous bone density in defects of the upper (562.4 [347.1; 777.8] and 301.5 [163.0; 439.9], respectively (р = 0.84) and lower (1379.0 [1116.2; 1641.9] HU and 848.6 [630.6; 1066.6] HU, respectively, p = 0.96) jaws in the areas of molars and premolars with “large” defects are significantly different from the indicators “small” defects (299.7 [176.9; 422.4] and 642.6 [470.4; 814.9], 1061.1 [866.5; 1255.7] and 608.3 [440.5; 776.1, respectively). The average bone density of the alveolar process of the upper jaw is almost the same in defects of different lengths. The average density of the cancellous bone of the alveolar part of the lower jaw in “large” defects has significant differences from “average” ones (p = 0.02) and “small” (p = 0.005) defects. Conclusions. The average density of cancellous bone of the alveolar part of the lower jaw in “large” defects has significant differences from “medium” (p = 0.02) and “small” (p = 0.005) defects, and regardless of the extent of the dentition defect corresponds to class D3 (350–850 HU) according to the Misch classification. The average density of cancellous bone of the alveolar process of the upper jaw in the areas of molars and premolars does not have significant differences depending on the extent of the dentition defect and corresponds to class D4 (150–350 HU) according to the Misch classification. Since one class includes a large range of values, the clinical classification of Misch does not allow taking into account individual bone density indicators that have statistically significant differences in different areas of the dentition.
- 22 December 2023
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 20 (3) , 266-270
Open AccessCorrelation of bone density of individual jaw sections according to Hounsfield with the length of the adentiary section in the cone-beam computer tomography program
Aim. To study the existence of a relationship between the density of bone tissue and the length of the edentulous part of the tooth row. Materials and methods. Evaluation of the density of the spongy substance of the jaws by the maximum and average value of HU. The density of cancellous bone was evaluated only in the areas available for implant placement. The groups consisted of the localization and extent of the dentition defect. Statistical methods included the estimation of the arithmetic mean (M), standard deviation (σ), error of the mean (m), confidence interval (95 % CI), estimation of the median (Me) and interquartile range ([Q1; Q2]), Student’s test (t criterion). Results. Maximum and average indicators of cancellous bone density in defects of the upper (562.4 [347.1; 777.8] and 301.5 [163.0; 439.9], respectively (р = 0.84) and lower (1379.0 [1116.2; 1641.9] HU and 848.6 [630.6; 1066.6] HU, respectively, p = 0.96) jaws in the areas of molars and premolars with “large” defects are significantly different from the indicators “small” defects (299.7 [176.9; 422.4] and 642.6 [470.4; 814.9], 1061.1 [866.5; 1255.7] and 608.3 [440.5; 776.1, respectively). The average bone density of the alveolar process of the upper jaw is almost the same in defects of different lengths. The average density of the cancellous bone of the alveolar part of the lower jaw in “large” defects has significant differences from “average” ones (p = 0.02) and “small” (p = 0.005) defects. Conclusions. The average density of cancellous bone of the alveolar part of the lower jaw in “large” defects has significant differences from “medium” (p = 0.02) and “small” (p = 0.005) defects, and regardless of the extent of the dentition defect corresponds to class D3 (350–850 HU) according to the Misch classification. The average density of cancellous bone of the alveolar process of the upper jaw in the areas of molars and premolars does not have significant differences depending on the extent of the dentition defect and corresponds to class D4 (150–350 HU) according to the Misch classification. Since one class includes a large range of values, the clinical classification of Misch does not allow taking into account individual bone density indicators that have statistically significant differences in different areas of the dentition.
- Open Access
- 28 April 2023
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 20 (1) , 69-75
Study of the capillary blood flow of the mucous membrane of the peri-implant area by laser Doppler flowmetry
Aim: to conduct a clinical analysis of the capillary blood flow of the mucous membrane of the peri-implant zone using laser Doppler flowmetry (LDF), as well as a comparative assessment of the effectiveness of the implanted structure with a surface, modified with silver nanoparticles (AgNP). Materials and methods. The study involved 40 patients undergoing rehabilitation for secondary partial adentia by the method of dental implantation. The examinees were divided into 2 groups: Group 1 (20 patients) – gingival formers with a surface modified by plasma electrooxidation and doped with AgNP were installed; Group 2 (20 patients) – standard gingival formers of the used implant system with a polished surface were installed. A control group (20 patients) was formed to determine the reference values. In total, 60 patients were involved in the study. Blood flow velocity in the studied groups was determined by laser Doppler flowmetry. Results. On the 10th day, when using gingival formers with a surface containing AgNP, a positive trend with increasing the blood flow rate of the mucous membrane of the peri-implant zone (6.97 mm/s) is determined, in contrast of using the gingival formers with a polished surface (5.425 mm/s). In the process of using the gum formers with a surface containing AgNPs, an increase in capillary blood flow rate (by 22.2 %) in a separate location is evidence of a reduction in inflammatory processes and a pronounced anti-inflammatory effect of the AgNP surface. Conclusions. Higher (by 22.2 %) indicators of capillary blood flow rate of the mucous membrane of the peri-implant zone in patients using gingival formers containing AgNP, compared to polished formers, indicates a pronounced anti-inflammatory effect of the proposed AgNP-doped surface. The values obtained in the group with AgNPs are as close as possible to the reference indicators of the blood flow rate in the capillary channel of the marginal gingiva of healthy people, which suggests the presence of a pronounced antimicrobial effect of silver nanoparticles on the surface of the gingival formers. Since blood flow in tissues is directly related to oxygenation of cells, reduction of local acidosis, reduction of inflammatory reactions and determines the state of tissue immunity, as well as directly affects the quality of reparative processes in damaged tissue, the obtained results allow recommending the proposed AgNP – surface for use in clinical practice.
- 28 April 2023
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 20 (1) , 69-75
Open AccessStudy of the capillary blood flow of the mucous membrane of the peri-implant area by laser Doppler flowmetry
Aim: to conduct a clinical analysis of the capillary blood flow of the mucous membrane of the peri-implant zone using laser Doppler flowmetry (LDF), as well as a comparative assessment of the effectiveness of the implanted structure with a surface, modified with silver nanoparticles (AgNP). Materials and methods. The study involved 40 patients undergoing rehabilitation for secondary partial adentia by the method of dental implantation. The examinees were divided into 2 groups: Group 1 (20 patients) – gingival formers with a surface modified by plasma electrooxidation and doped with AgNP were installed; Group 2 (20 patients) – standard gingival formers of the used implant system with a polished surface were installed. A control group (20 patients) was formed to determine the reference values. In total, 60 patients were involved in the study. Blood flow velocity in the studied groups was determined by laser Doppler flowmetry. Results. On the 10th day, when using gingival formers with a surface containing AgNP, a positive trend with increasing the blood flow rate of the mucous membrane of the peri-implant zone (6.97 mm/s) is determined, in contrast of using the gingival formers with a polished surface (5.425 mm/s). In the process of using the gum formers with a surface containing AgNPs, an increase in capillary blood flow rate (by 22.2 %) in a separate location is evidence of a reduction in inflammatory processes and a pronounced anti-inflammatory effect of the AgNP surface. Conclusions. Higher (by 22.2 %) indicators of capillary blood flow rate of the mucous membrane of the peri-implant zone in patients using gingival formers containing AgNP, compared to polished formers, indicates a pronounced anti-inflammatory effect of the proposed AgNP-doped surface. The values obtained in the group with AgNPs are as close as possible to the reference indicators of the blood flow rate in the capillary channel of the marginal gingiva of healthy people, which suggests the presence of a pronounced antimicrobial effect of silver nanoparticles on the surface of the gingival formers. Since blood flow in tissues is directly related to oxygenation of cells, reduction of local acidosis, reduction of inflammatory reactions and determines the state of tissue immunity, as well as directly affects the quality of reparative processes in damaged tissue, the obtained results allow recommending the proposed AgNP – surface for use in clinical practice.
- Open Access
- 22 August 2022
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 19 (2) , 154-159
Experience of the treatment of combat injuries of the maxillofacial area with titanium implants in the conditions of modern war
Мета роботи – описати особливості бойової травми щелепно-лицевої ділянки та навести можливі варіанти хірургічного лікування з використанням титанових імплантатів. Матеріали та методи. Наведено опис клінічних випадків лікування високошвидкісних бойових травм щелепно-лицевої ділянки у відділенні щелепно-лицевої хірургії з отоларингологічними ліжками КНП «Міська лікарня екстреної та швидкої медичної допомоги Запорізької міської ради». Результати. Післяопераційне спостереження за пацієнтами, які постраждали від поранення високошвидкісними снарядами, показало позитивні результати лікування в усіх випадках. Негативні наслідки перенесеної травми, виявлені в післяопераційному періоді, – стійкий параліч мімічної мускулатури, дисфункції нижньої щелепи (обмеження відкривання рота), некроз пошкоджених тканин ротової порожнини, некроз і нагноєння тканин навколо ран, виникнення деформувальних рубців і нориць, секвестрація. Найчастіші функціональні порушення внаслідок травми – параліч мімічної мускулатури, порушення функції нижньої щелепи, які діагностували у 100 % випадків, що описали. Секвестрацію кісткових відламків виявили тільки в одного хворого, ще в одного пацієнта діагностували всі названі негативні патологічні наслідки перенесеної високошвидкісної травми. Висновки. Наш досвід лікування вогнепальних високошвидкісних поранень обличчя дає підстави зробити висновок, що результати лікування та вибір хірургічної тактики залежать передусім від тяжкості поранення та ступеня пошкодження м’яких і кісткових тканин обличчя. Різноманіття характеру травм не дає змогу визначити єдиний «стандарт» термінів для остаточного хірургічного лікування.
- 22 August 2022
- Published by Zaporizhzhia State Medical and Pharmaceutical University in Pathologia
- Vol. 19 (2) , 154-159
Open AccessExperience of the treatment of combat injuries of the maxillofacial area with titanium implants in the conditions of modern war
Мета роботи – описати особливості бойової травми щелепно-лицевої ділянки та навести можливі варіанти хірургічного лікування з використанням титанових імплантатів. Матеріали та методи. Наведено опис клінічних випадків лікування високошвидкісних бойових травм щелепно-лицевої ділянки у відділенні щелепно-лицевої хірургії з отоларингологічними ліжками КНП «Міська лікарня екстреної та швидкої медичної допомоги Запорізької міської ради». Результати. Післяопераційне спостереження за пацієнтами, які постраждали від поранення високошвидкісними снарядами, показало позитивні результати лікування в усіх випадках. Негативні наслідки перенесеної травми, виявлені в післяопераційному періоді, – стійкий параліч мімічної мускулатури, дисфункції нижньої щелепи (обмеження відкривання рота), некроз пошкоджених тканин ротової порожнини, некроз і нагноєння тканин навколо ран, виникнення деформувальних рубців і нориць, секвестрація. Найчастіші функціональні порушення внаслідок травми – параліч мімічної мускулатури, порушення функції нижньої щелепи, які діагностували у 100 % випадків, що описали. Секвестрацію кісткових відламків виявили тільки в одного хворого, ще в одного пацієнта діагностували всі названі негативні патологічні наслідки перенесеної високошвидкісної травми. Висновки. Наш досвід лікування вогнепальних високошвидкісних поранень обличчя дає підстави зробити висновок, що результати лікування та вибір хірургічної тактики залежать передусім від тяжкості поранення та ступеня пошкодження м’яких і кісткових тканин обличчя. Різноманіття характеру травм не дає змогу визначити єдиний «стандарт» термінів для остаточного хірургічного лікування.
- Open Access
- 30 September 2021
- Published by Dnipro State Medical University in Medicni perspektivi
- Vol. 26 (3) , 145-151
Microbial landscape and immune status in maxillary sinusitis of stomatogenic origin
Oroanthral fistula (anastomosis) is an element preventing the restoration of homeostasis in the maxillary sinus due to the constant flow of microbes from the oral cavity. It is also contributes to frequent exacerbations of maxillary sinusitis. Saprophytic gram-positive cocci and fungi of the oral cavity are dominating representatives of the microbial flora in the maxillary sinus. As the result of research, we found that in the case of maxillary sinusitis with oroantral fistula fungi made up 25.0% of microbiota, gram-positive bacteria – 41.7%, gram-negative bacteria – 33.3%. Gram-positive cocci from the Staphylococcus genus (Staphylococcus aureus and Staphylococcus epidermidis) and fungi (Candida albicans) comprised the biggest proportion of microbial flora that 33.3% and 16.7%, respectively. Slightly decreased levels of monocytes in venous blood was noted in 69.2% of patients. The average value of total serum IgE in group with oroantal fistula was 226.2 (70.4) IU/ml, the result exceeded normal limits almost in 2.26 times. Large circulating immune complexes (CICs) were normal in all patients in the group with iatrogenic maxillary sinusitis. The average lavels of small size CICs was 170.2 (4.23) ОU, which is in 1.06 times higher the upper limit of the norm (160 ОU). Elevated levels of total Ig E in serum of patients with oroanthral fistula indicates allergic sensitization. The detection of increased levels of CICs with small and medium sizes in serum may indicate a susceptibility of this category of patients to the development of immunopathological reactions.
- 30 September 2021
- Published by Dnipro State Medical University in Medicni perspektivi
- Vol. 26 (3) , 145-151
Open AccessMicrobial landscape and immune status in maxillary sinusitis of stomatogenic origin
Oroanthral fistula (anastomosis) is an element preventing the restoration of homeostasis in the maxillary sinus due to the constant flow of microbes from the oral cavity. It is also contributes to frequent exacerbations of maxillary sinusitis. Saprophytic gram-positive cocci and fungi of the oral cavity are dominating representatives of the microbial flora in the maxillary sinus. As the result of research, we found that in the case of maxillary sinusitis with oroantral fistula fungi made up 25.0% of microbiota, gram-positive bacteria – 41.7%, gram-negative bacteria – 33.3%. Gram-positive cocci from the Staphylococcus genus (Staphylococcus aureus and Staphylococcus epidermidis) and fungi (Candida albicans) comprised the biggest proportion of microbial flora that 33.3% and 16.7%, respectively. Slightly decreased levels of monocytes in venous blood was noted in 69.2% of patients. The average value of total serum IgE in group with oroantal fistula was 226.2 (70.4) IU/ml, the result exceeded normal limits almost in 2.26 times. Large circulating immune complexes (CICs) were normal in all patients in the group with iatrogenic maxillary sinusitis. The average lavels of small size CICs was 170.2 (4.23) ОU, which is in 1.06 times higher the upper limit of the norm (160 ОU). Elevated levels of total Ig E in serum of patients with oroanthral fistula indicates allergic sensitization. The detection of increased levels of CICs with small and medium sizes in serum may indicate a susceptibility of this category of patients to the development of immunopathological reactions.
- Open Access
- 5 October 2020
- Published by Dnipro State Medical University in Medicni perspektivi
- Vol. 25 (3) , 153-160
The state of oral mucosa in patients with type 2 diabetes
The state of oral mucosa in patients with type 2 diabetes
- 5 October 2020
- Published by Dnipro State Medical University in Medicni perspektivi
- Vol. 25 (3) , 153-160
Open AccessThe state of oral mucosa in patients with type 2 diabetes
The state of oral mucosa in patients with type 2 diabetes
- Open Access
- 29 July 2016
- Published by OU Scientific Route in EUREKA: Health Sciences
- Vol. 4 (4) , 23-29
IATROGENIC AND ODONTOGENIC FORMS OF STOMATOGENIC MAXILLARY SINUSITIS. ULTRASOUND CHARACTERISTIC
The special features of transfer of information of the cone-beam computed tomography allows make conclusions about the character of pathological changes in maxillary sinuses only by the features of form and outlines of shadow of changed mucous tunic of sinus at its equal intensity that often leads to the incorrect interpretation of the results of research. The high sensitivity of two-dimensional ultrasonography as for thickening (sclerosis) of mucous tunic, its edema (effusion) and exudation (purulent or serous) allows the more widen use of this method in addition to the cone-beam tomography at examination of maxillary sinuses. The other important moment is an absence of harmful influence of ultrasound on organism that makes it ideal for assessment of the dynamics of clinical course and allows prescribe it for pregnant and children. The two-dimensional ultrasound examination of 86 patients with stomatogenic maxillary sinusitis (iatrogenic – 79,1 % odontogenic – 20,9 % forms) was carried out using ultrasound diagnostic apparatus АCUSON X 500, ATSmod.539 (SIEMENS, USA) in В-mode by the method of V.V. Shilenkova. In the result of research was found out that sonographic picture of the maxillary sinuses at stomatogenic maxillary sinusitis depends on etio-pathogenetic form of disease. For iatrogenic form of maxillary sinusitis of stomatogenic origin are typical the ultrasound signs of chronic inflammation with many inflammatory inclusions in sinus, sclerosis of mucous tunic and serous effusion. By frequency prevailed: hyperechogenicity of membrane (30,8 %), its heterogenous echostructure (52,9 %), hyperechogenic character of content (39,7 %), arched outline of the back wall (36,8 %). For odontogenic form of maxillary sinusitis of stomatogenic origin are typical the ultrasound signs of acute catarrhal inflammation with predomination of exudation in the mucous tunic and absence of contents in the lumen of sinus. By frequency prevailed: hypoechogenicity of membrane (27,8 %), its homogenous echostructure (45,6 %); acoustic shadow in sinus (72,2 %), arched outline of the back wall (27,8 %).
- 29 July 2016
- Published by OU Scientific Route in EUREKA: Health Sciences
- Vol. 4 (4) , 23-29
Open AccessIATROGENIC AND ODONTOGENIC FORMS OF STOMATOGENIC MAXILLARY SINUSITIS. ULTRASOUND CHARACTERISTIC
The special features of transfer of information of the cone-beam computed tomography allows make conclusions about the character of pathological changes in maxillary sinuses only by the features of form and outlines of shadow of changed mucous tunic of sinus at its equal intensity that often leads to the incorrect interpretation of the results of research. The high sensitivity of two-dimensional ultrasonography as for thickening (sclerosis) of mucous tunic, its edema (effusion) and exudation (purulent or serous) allows the more widen use of this method in addition to the cone-beam tomography at examination of maxillary sinuses. The other important moment is an absence of harmful influence of ultrasound on organism that makes it ideal for assessment of the dynamics of clinical course and allows prescribe it for pregnant and children. The two-dimensional ultrasound examination of 86 patients with stomatogenic maxillary sinusitis (iatrogenic – 79,1 % odontogenic – 20,9 % forms) was carried out using ultrasound diagnostic apparatus АCUSON X 500, ATSmod.539 (SIEMENS, USA) in В-mode by the method of V.V. Shilenkova. In the result of research was found out that sonographic picture of the maxillary sinuses at stomatogenic maxillary sinusitis depends on etio-pathogenetic form of disease. For iatrogenic form of maxillary sinusitis of stomatogenic origin are typical the ultrasound signs of chronic inflammation with many inflammatory inclusions in sinus, sclerosis of mucous tunic and serous effusion. By frequency prevailed: hyperechogenicity of membrane (30,8 %), its heterogenous echostructure (52,9 %), hyperechogenic character of content (39,7 %), arched outline of the back wall (36,8 %). For odontogenic form of maxillary sinusitis of stomatogenic origin are typical the ultrasound signs of acute catarrhal inflammation with predomination of exudation in the mucous tunic and absence of contents in the lumen of sinus. By frequency prevailed: hypoechogenicity of membrane (27,8 %), its homogenous echostructure (45,6 %); acoustic shadow in sinus (72,2 %), arched outline of the back wall (27,8 %).
- Open Access
- 19 March 2015
- Published by OU Scientific Route in ScienceRise
- Vol. 3 (4(8)) , 78-86
The use of different methods of augmentation horizontally and vertically on the atrophy of the alveolar bone of the upper and alveolar part of the mandible
Основной проблемой дентальной имплантации, является недостаточное количество кости. Однозначного решения проблемы атрофии не существует. Выбор метода остеопластики и трансплантата зависит от точного определения степени атрофии костной ткани, характера и размеров дефекта. На клинических примерах продемонстрированы методы восстановления объема кости верхней и нижней челюстей с использованием трансплантатов различного происхождения
- 19 March 2015
- Published by OU Scientific Route in ScienceRise
- Vol. 3 (4(8)) , 78-86
Open AccessThe use of different methods of augmentation horizontally and vertically on the atrophy of the alveolar bone of the upper and alveolar part of the mandible
Основной проблемой дентальной имплантации, является недостаточное количество кости. Однозначного решения проблемы атрофии не существует. Выбор метода остеопластики и трансплантата зависит от точного определения степени атрофии костной ткани, характера и размеров дефекта. На клинических примерах продемонстрированы методы восстановления объема кости верхней и нижней челюстей с использованием трансплантатов различного происхождения
- Open Access
- 27 January 2015
- Published by OU Scientific Route in ScienceRise
- Vol. 1 (3 (6)) , 25-28
Состояние цитокинового статуса больных вялотекущим острым одонтогенным остеомиелитом челюстей
Состояние цитокинового статуса больных вялотекущим острым одонтогенным остеомиелитом челюстей
- 27 January 2015
- Published by OU Scientific Route in ScienceRise
- Vol. 1 (3 (6)) , 25-28
Open AccessСостояние цитокинового статуса больных вялотекущим острым одонтогенным остеомиелитом челюстей
Состояние цитокинового статуса больных вялотекущим острым одонтогенным остеомиелитом челюстей