EPEkaterina A. Pecherskaya

Ekaterina A. Pecherskaya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ekaterina A. Pecherskaya has a total of 186 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Hardware and software complex for microarc oxidation of medical devices

    by P.E. Golubkov, E.A. Pecherskaya, O.V. Karpanin, A.O. Krivenkov, F.A. Abdullin

    Obtaining biocompatible microarc oxide coatings on titanium and magnesium implants is currently difficult due to the imperfection of the technical means used for coating. In particular, microarc oxidation units operating on sinusoidal current are built on an outdated electronic component base and have limited functionality. Work purpose – development of a hardware and software complex for microarc oxidation of medical devices made of titanium and magnesium alloys with sinusoidal current, which has increased functionality. A hardware and software complex has been developed that allows for microarc oxidation in sinusoidal current modes with the ability to switch the oxidation current without interrupting the processing process, smoothly adjust the ratio of anode and cathode current, and measure the impedance of a galvanic cell. The developed software and hardware complex can be used to obtain biocompatible microarc oxide coatings on medical devices made of magnesium and titanium, for example, dental and orthopedic implants.

  • A measuring device for monitoring of external respiratory indices by dielcometry method

    by E.A. Pecherskaya, V.A. Baranov, A.I. Frolova

    Reliable operational remote assessment of the patient's condition during outpatient treatment of a number of diseases, including socially significant ones, cannot be complete and reliable without determining the state of the respiratory system by measuring external respiratory indices. This determines the urgency of developing a portable measuring device with a wireless interface for transmitting measurement information in real time during monitoring, the design of which allows the patient to wear it for a long time. Work purpose – development of a portable measuring device for remote monitoring of external respiration indices. Two variants of the dielcometric sensor design were developed, comparative experimental studies were carried out, on the basis of which the fields of application of both variants of the sensor were determined, the structure and algorithm of functioning of the device for measurement of external respiration indices by dielcometry method were developed. The development of a portable device for measuring external respiration indices will allow to carry out remote monitoring of the patient's respiratory system state in the process of outpatient treatment.

  • Galvanic isolation of analog signals with improved metrological characteristics

    by E. A. Pecherskaya, D. V. Yakushov

    The disadvantages of galvanically isolated converters that transmit information through an insulating barrier in digital or analog form are considered, such as the high cost of components or a conversion error of more than 1 %. Such galvanically isolated converters are necessary for the safe operation of equipment operating at voltages above 50 V. A galvanic analog signal separator has been developed that transmits information in analog form through an insulating barrier without transferring it (converting it) to digital form and has a conversion error of 0.22 % at rated voltage. This galvanic separator can be used as part of measuring devices such as converters, sensors, and analog signal transceivers without transferring information to digital form. A method of transmitting an analog information signal in the absence of an electrical connection is investigated, which makes it possible to reduce the error and increase the noise immunity of the converter.The circuit of the proposed galvanic analog signal separator is based on negative feedback, the circuit of which passes through a modulator, transformer and demodulator on the primary side. The signal from the output of the demodulator is sent to one of the two inputs of the error amplifier. The error amplifier adjusts the voltages at both inputs in strict accordance with each other, due to which the voltage at the output of the demodulator is exactly equal to the input voltage supplied to the other input of the error amplifier. The second demodulator, identical to the first one, is installed on the secondary side. The use of two demodulators made it possible to achieve accurate transmission of the analog signal from the primary side to the secondary side. A laboratory sample of a galvanic analog signal separator has been manufactured and tested. According to the test results, the expediency of using negative feedback has been confirmed: the relative conversion error has been reduced by three times compared to devices without feedback. The relative error of the conversion of the proposed device over the entire input voltage range was no more than 0.7 % and 0.22 % at the nominal input value. The device can be used as part of measuring equipment operating at high (more than 10 kV) voltages.

  • Design and Technological Solution Providing Temperature Self-Compensation of Thin-Film Chip Resistors

    by E. A. Pecherskaya, S. A. Gurin, S. V. Konovalov, A. E. Shepeleva, M. D. Novichkov

    This work aims to address the problem of improving the accuracy of thin-film resistors. The main cause of this issue is the uncontrolled change in resistor resistance over time and under the influence of temperature, which makes it difficult to achieve high resistance stability. To solve this problem, the use of compensation layers with temperature coefficients of resistance of opposite signs is proposed. A design and technological solution has been developed for ultra-precision multilayer and combined thin-film resistive structures with temperature self-compensation, made of metal–silicide alloys and nichrome-based alloys, as well as K-30S cermet and nickel, respectively. The combination of films made of Kh20N75Yu alloy and K-30S cermet was chosen based on the optimal ratio of layer thicknesses. The structure and topology of combined and multilayer thin-film resistors have been developed. A technological process for manufacturing thin-film chip resistors has been created; deposition modes and topology formation by photolithography followed by temperature stabilization have been refined. Functional tests of a pilot batch of samples have been carried out, for which additional technological equipment was developed. The developed technology makes it possible to achieve a temperature coefficient of resistance of ±5 × 10–7 °C–1 in the operating temperature range from ‒60 to +125°C. The scientific novelty of this work lies in the ability to combine thin films of Kh20N75Yu/K-30S for multilayer and K-30S/Ni for combined resistive structures in the proposed design to achieve temperature compensation and improve stability characteristics.

  • Microarc Oxidation Process Complex Control System

    by E. A. Pecherskaya, A. M. Metal’nikov, A. A. Maksov, V. S. Aleksandrov, A. E. Shepeleva

  • Study of the Influence of Thin-Film Resistors Self-Heating on Temperature Stability

    by E.A. Pecherskaya, A.E. Shepeleva, S.A. Gurin, Novichkov, V.I. Grishchenko, V.A. Ilyin, Joint-stock company "Scientific Research Institute of Electronic-Mechanical Devices"

    The relevance of the research topic is due to the development of the electronic component base, which is most commonly represented by resistors. The purpose of the work is to develop a technique necessary for studying the effect of self-heating on the stability of the output parameters of a thin-film resistor. Thin-film resistors are obtained in several stages, namely, substrate preparation, deposition of a conductive material, a protective coating, photolithography and heat treatment. The developed technique for assessing the effect of self-heating on the stability of the output parameters is presented. The results of measuring the thin-film resistors resistance during self-heating and during heating as a result of exposure to the ambient temperature in a muffle furnace (SNOL) are evaluated. In the course of the work, an insignificant effect of thin-film resistors self-heating on their temperature stability was revealed.

  • Chip Resistors based on the Alloy X20N75YU and Kermets K-30S with an Additional Compensation Layer

    by E.A. Pecherskaya, A.E. Shepeleva, S.A. Gurin, Novichkov, V.S. Mamontov, P.A. Gurin

    The purpose of the work is to develop the design and technological process of manufacturing multilayer and combined thin-film surface-mounted resistors with additional compensation layers. The objectives of the study are: the selection of materials and their thicknesses, which are able to compensate each other according to the parameters of the TCS. For this purpose, pairs of X20H75YU/K-30C, as well as K-30C/Ni were used. Topologies for combined and multilayer TPR with a nominal value of 10 kOhm are proposed. The initial data were calculations of the resistances of thin films for both cases. According to the parameters measurements results of the temperature stability of the resistance for —60 °C and 125 °C, aging curves are constructed. It is shown that the measurement results and the proposed design and technological solution make it possible to obtain thin-film chip resistors having a TCS of at least ±5 ×10—7 1/°C in the operating temperature range from —60 °C to +125 °C. The results obtained can be used in scientific research and in industry in the development of a component-electronic database.

  • Estimation of Porosity of Microarc Oxide Coating Based on Optical Image Recognition

    by E. A. Pecherskaya, A. A. Maksov, S. V. Konovalov, P. E. Golubkov, M. A. Mitrohin, S. A. Gurin, M. D. Novichkov

    The work is aimed at solving the problem of improving the quality control of coatings with a porous structure. The problem arises due to the lack of an effective and nondestructive method for assessing the porosity of microarc oxide coatings. Accurate porosity control is necessary to ensure the reliability and durability of coatings, as well as to prevent their defects. The use of optical image recognition techniques can improve the process of indirect measurement of coating porosity and improve the quality of control without affecting the object. The factors affecting the porosity of the microarc oxide coating, as well as methods for its determination, are systematized. A method for estimating the porosity of oxide coatings of AD31 aluminum alloy samples based on a recognition program written in the MATLAB R2020a environment is proposed as well as the surface morphology images using modern microscopy methods. A statistical analysis of the surface morphology was carried out, which confirmed good agreement between the porosity estimate and the data obtained during image processing using scanning electron microscope software. The relative error of the proposed method does not exceed 10%. The scientific novelty of the work consists in the development of algorithms for a unique nondestructive testing method, recognition of porous structures based on optical data, which contribute to increasing the efficiency of porosity estimation and improving the characteristics of oxide coatings.

  • Calculation of the spray supply system characteristics for obtaining film material by spray-pyrolysis

    by E.A. Pecherskaya, A.D. Semenov, T.O. Zinchenko, S.A. Gurin, S.V. Konovalov, Novichkov, A.E. Shepeleva, D.E. Tuzova