Ross D. Venook
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ross D. Venook has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
Albert Macovski
Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California
3 shared publicationsGreig C. Scott
Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
3 shared publicationsSteven M. Conolly
Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
3 shared publicationsGarry E. Gold
Department of Radiology, Stanford University, Stanford, California, USA
2 shared publicationsJorg de Bruin
Department of Cardiothoracic Surgery, Stanford University, Stanford, California, USA
2 shared publicationsNathaniel I. Matter
Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA
2 shared publications
Latest Publications
- Open Access
- 13 October 2020
- Published by Springer Nature in Biomedical Engineering Education
- Vol. 1 (1) , 195-200
Trace Matrix: A Framing Tool to Improve Communication and Debugging in Remote Instrumentation Lab Courses
- 13 October 2020
- Published by Springer Nature in Biomedical Engineering Education
- Vol. 1 (1) , 195-200
Open AccessTrace Matrix: A Framing Tool to Improve Communication and Debugging in Remote Instrumentation Lab Courses
- Open Access
Pneumask: Modified Full-Face Snorkel Masks as Reusable Personal Protective Equipment for Hospital Personnel
Here we adapt and evaluate a full-face snorkel mask for use as personal protective equipment (PPE) for health care workers, who lack appropriate alternatives during the COVID-19 crisis in the spring of 2020. The design (referred to as Pneumask) consists of a custom snorkel-specific adapter that couples the snorkel-port of the mask to a rated filter (either a medical-grade ventilator inline filter or an industrial filter). This design has been tested for the sealing capability of the mask, filter performance, CO2 buildup and clinical usability. These tests found the Pneumask capable of forming a seal that exceeds the standards required for half-face respirators or N95 respirators. Filter testing indicates a range of options with varying performance depending on the quality of filter selected, but with typical filter performance exceeding or comparable to the N95 standard. CO2 buildup was found to be roughly equivalent to levels found in half-face elastomeric respirators in literature. Clinical usability tests indicate sufficient visibility and, while speaking is somewhat muffled, this can be addressed via amplification (Bluetooth voice relay to cell phone speakers through an app) in noisy environments. We present guidance on the assembly, usage (donning and doffing) and decontamination protocols. The benefit of the Pneumask as PPE is that it is reusable for longer periods than typical disposable N95 respirators, as the snorkel mask can withstand rigorous decontamination protocols (that are standard to regular elastomeric respirators). With the dire worldwide shortage of PPE for medical personnel, our conclusions on the performance and efficacy of Pneumask as an N95-alternative technology are cautiously optimistic . Key points: Full-face snorkel masks are adapted for use as Personal Protective Equipment during the COVID-19 crisis, using a custom adapter that facilitates the attachment of inline medical-grade respiratory filters or NIOSH industrial respirator filters. This solution was designed as a reusable stopgap solution for healthcare workers to help address the short-term global N95 respirator shortage.
Open AccessPneumask: Modified Full-Face Snorkel Masks as Reusable Personal Protective Equipment for Hospital Personnel
Here we adapt and evaluate a full-face snorkel mask for use as personal protective equipment (PPE) for health care workers, who lack appropriate alternatives during the COVID-19 crisis in the spring of 2020. The design (referred to as Pneumask) consists of a custom snorkel-specific adapter that couples the snorkel-port of the mask to a rated filter (either a medical-grade ventilator inline filter or an industrial filter). This design has been tested for the sealing capability of the mask, filter performance, CO2 buildup and clinical usability. These tests found the Pneumask capable of forming a seal that exceeds the standards required for half-face respirators or N95 respirators. Filter testing indicates a range of options with varying performance depending on the quality of filter selected, but with typical filter performance exceeding or comparable to the N95 standard. CO2 buildup was found to be roughly equivalent to levels found in half-face elastomeric respirators in literature. Clinical usability tests indicate sufficient visibility and, while speaking is somewhat muffled, this can be addressed via amplification (Bluetooth voice relay to cell phone speakers through an app) in noisy environments. We present guidance on the assembly, usage (donning and doffing) and decontamination protocols. The benefit of the Pneumask as PPE is that it is reusable for longer periods than typical disposable N95 respirators, as the snorkel mask can withstand rigorous decontamination protocols (that are standard to regular elastomeric respirators). With the dire worldwide shortage of PPE for medical personnel, our conclusions on the performance and efficacy of Pneumask as an N95-alternative technology are cautiously optimistic . Key points: Full-face snorkel masks are adapted for use as Personal Protective Equipment during the COVID-19 crisis, using a custom adapter that facilitates the attachment of inline medical-grade respiratory filters or NIOSH industrial respirator filters. This solution was designed as a reusable stopgap solution for healthcare workers to help address the short-term global N95 respirator shortage.
- Open Access
- 6 October 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (5) , 1085-1095
Three‐dimensional prepolarized magnetic resonance imaging using rapid acquisition with relaxation enhancement
Prepolarized MRI (PMRI) with pulsed electromagnets has the potential to produce diagnostic quality 0.5‐ to 1.0‐T images with significantly reduced cost, susceptibility artifacts, specific absorption rate, and gradient noise. In PMRI, the main magnetic field cycles between a high field (Bp) to polarize the sample and a homogeneous, low field (B0) for data acquisition. This architecture combines the higher SNR of the polarizing field with the imaging benefits of the lower field. However, PMRI can only achieve high SNR efficiency for volumetric imaging with 3D rapid imaging techniques, such as rapid acquisition with relaxation enhancement (RARE) (FSE, TSE), because slice‐interleaved acquisition and longitudinal magnetization storage are both inefficient in PMRI. This paper demonstrates the use of three techniques necessary to achieve efficient, artifact‐free RARE in PMRI: quadratic nulling of concomitant gradient fields, electromotive force cancelation during field ramping, and phase compensation of CPMG echo trains. This paper also demonstrates the use of 3D RARE in PMRI to achieve standard T1 and fat‐suppressed T2 contrast in phantoms and in vivo wrists. These images show strong potential for future clinical application of PMRI to extremity musculoskeletal imaging and peripheral angiography. Magn Reason Med, 2006. © 2006 Wiley‐Liss.Inc.
- 6 October 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (5) , 1085-1095
Open AccessThree‐dimensional prepolarized magnetic resonance imaging using rapid acquisition with relaxation enhancement
Prepolarized MRI (PMRI) with pulsed electromagnets has the potential to produce diagnostic quality 0.5‐ to 1.0‐T images with significantly reduced cost, susceptibility artifacts, specific absorption rate, and gradient noise. In PMRI, the main magnetic field cycles between a high field (Bp) to polarize the sample and a homogeneous, low field (B0) for data acquisition. This architecture combines the higher SNR of the polarizing field with the imaging benefits of the lower field. However, PMRI can only achieve high SNR efficiency for volumetric imaging with 3D rapid imaging techniques, such as rapid acquisition with relaxation enhancement (RARE) (FSE, TSE), because slice‐interleaved acquisition and longitudinal magnetization storage are both inefficient in PMRI. This paper demonstrates the use of three techniques necessary to achieve efficient, artifact‐free RARE in PMRI: quadratic nulling of concomitant gradient fields, electromotive force cancelation during field ramping, and phase compensation of CPMG echo trains. This paper also demonstrates the use of 3D RARE in PMRI to achieve standard T1 and fat‐suppressed T2 contrast in phantoms and in vivo wrists. These images show strong potential for future clinical application of PMRI to extremity musculoskeletal imaging and peripheral angiography. Magn Reason Med, 2006. © 2006 Wiley‐Liss.Inc.
- Open Access
- 24 May 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (1) , 177-186
Prepolarized magnetic resonance imaging around metal orthopedic implants
A prepolarized MRI (PMRI) scanner was used to image near metal implants in agar gel phantoms and in in vivo human wrists. Comparison images were made on 1.5‐ and 0.5‐T conventional whole‐body systems. The PMRI experiments were performed in a smaller bore system tailored to extremity imaging with a prepolarization magnetic field of 0.4 T and a readout magnetic field of 27–54 mT (1.1–2.2 MHz). Scan parameters were chosen with equal readout gradient strength over a given field of view and matrix size to allow unbiased evaluation of the benefits of lower readout frequency. Results exhibit substantial reduction in metal susceptibility artifacts under PMRI versus conventional scanners. A new artifact quantification technique is also presented, and phantom results confirm that susceptibility artifacts improve as expected with decreasing readout magnetic field using PMRI. This proof‐of‐concept study demonstrates that prepolarized techniques have the potential to provide diagnostic cross‐sectional images for postoperative evaluation of patients with metal implants. Magn Reson Med.
- 24 May 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (1) , 177-186
Open AccessPrepolarized magnetic resonance imaging around metal orthopedic implants
A prepolarized MRI (PMRI) scanner was used to image near metal implants in agar gel phantoms and in in vivo human wrists. Comparison images were made on 1.5‐ and 0.5‐T conventional whole‐body systems. The PMRI experiments were performed in a smaller bore system tailored to extremity imaging with a prepolarization magnetic field of 0.4 T and a readout magnetic field of 27–54 mT (1.1–2.2 MHz). Scan parameters were chosen with equal readout gradient strength over a given field of view and matrix size to allow unbiased evaluation of the benefits of lower readout frequency. Results exhibit substantial reduction in metal susceptibility artifacts under PMRI versus conventional scanners. A new artifact quantification technique is also presented, and phantom results confirm that susceptibility artifacts improve as expected with decreasing readout magnetic field using PMRI. This proof‐of‐concept study demonstrates that prepolarized techniques have the potential to provide diagnostic cross‐sectional images for postoperative evaluation of patients with metal implants. Magn Reson Med.
- 3 May 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (6) , 1362-1371
Magnetic resonance imaging with T1 dispersion contrast
Prepolarized MRI uses pulsed magnetic fields to produce MR images by polarizing the sample at one field strength (∼0.5 T) before imaging at a much lower field (∼50 mT). Contrast reflecting the T1 of the sample at an intermediate field strength is achieved by polarizing the sample and then allowing the magnetization to decay at a chosen “evolution” field before imaging. For tissues whose T1 varies with field strength (T1 dispersion), the difference between two images collected with different evolution fields yields an image with contrast reflecting the slope of the T1 dispersion curve between those fields. Tissues with high protein content, such as muscle, exhibit rapid changes in their T1 dispersion curves at 49 and 65 mT due to cross‐relaxation with nitrogen nuclei in protein backbones. Tissues without protein, such as fat, have fairly constant T1 over this range; subtracting images with two different evolution fields eliminates signal from flat T1 dispersion species. T1 dispersion protein‐content images of the human wrist and foot are presented, showing clear differentiation between muscle and fat. This technique may prove useful for delineating regions of muscle tissue in the extremities of patients with diseases affecting muscle viability, such as diabetic neuropathy, and for visualizing the protein content of tissues in vivo. Magn Reson Med 2006.
- 3 May 2006
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (6) , 1362-1371
Magnetic resonance imaging with T1 dispersion contrast
Prepolarized MRI uses pulsed magnetic fields to produce MR images by polarizing the sample at one field strength (∼0.5 T) before imaging at a much lower field (∼50 mT). Contrast reflecting the T1 of the sample at an intermediate field strength is achieved by polarizing the sample and then allowing the magnetization to decay at a chosen “evolution” field before imaging. For tissues whose T1 varies with field strength (T1 dispersion), the difference between two images collected with different evolution fields yields an image with contrast reflecting the slope of the T1 dispersion curve between those fields. Tissues with high protein content, such as muscle, exhibit rapid changes in their T1 dispersion curves at 49 and 65 mT due to cross‐relaxation with nitrogen nuclei in protein backbones. Tissues without protein, such as fat, have fairly constant T1 over this range; subtracting images with two different evolution fields eliminates signal from flat T1 dispersion species. T1 dispersion protein‐content images of the human wrist and foot are presented, showing clear differentiation between muscle and fat. This technique may prove useful for delineating regions of muscle tissue in the extremities of patients with diseases affecting muscle viability, such as diabetic neuropathy, and for visualizing the protein content of tissues in vivo. Magn Reson Med 2006.
- Open Access
- 28 November 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (1) , 203-209
Dual in vivo magnetic resonance evaluation of magnetically labeled mouse embryonic stem cells and cardiac function at 1.5 t
Cell therapy has demonstrated the potential to restore injured myocardium. A reliable in vivo imaging method to localize transplanted cells and monitor their restorative effects will enable a systematic investigation of this therapeutic modality. The dual MRI capability of imaging both magnetically labeled mouse embryonic stem cells (mESC) and their restorative effects on cardiac function in a murine model of acute myocardial infarction is demonstrated. Serial in vivo MR detection of transplanted mESC and monitoring of the mESC‐treated myocardium was conducted over a 4‐week period using a 1.5 T clinical scanner. During the 4‐week duration, the mESC‐treated myocardium demonstrated sustained improvement of the left ventricular (LV) ejection fraction and conservation of LV mass. Furthermore, no significant difference of their restorative effects on the cardiac function was created by the magnetic labeling of mESC. Thus, in vivo MRI enables simultaneous detection of transplanted mESC and their therapeutic effect on the injured myocardium. Magn Reson Med 2006.
- 28 November 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 55 (1) , 203-209
Open AccessDual in vivo magnetic resonance evaluation of magnetically labeled mouse embryonic stem cells and cardiac function at 1.5 t
Cell therapy has demonstrated the potential to restore injured myocardium. A reliable in vivo imaging method to localize transplanted cells and monitor their restorative effects will enable a systematic investigation of this therapeutic modality. The dual MRI capability of imaging both magnetically labeled mouse embryonic stem cells (mESC) and their restorative effects on cardiac function in a murine model of acute myocardial infarction is demonstrated. Serial in vivo MR detection of transplanted mESC and monitoring of the mESC‐treated myocardium was conducted over a 4‐week period using a 1.5 T clinical scanner. During the 4‐week duration, the mESC‐treated myocardium demonstrated sustained improvement of the left ventricular (LV) ejection fraction and conservation of LV mass. Furthermore, no significant difference of their restorative effects on the cardiac function was created by the magnetic labeling of mESC. Thus, in vivo MRI enables simultaneous detection of transplanted mESC and their therapeutic effect on the injured myocardium. Magn Reson Med 2006.
- 9 September 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (4) , 983-993
Automatic tuning of flexible interventional RF receiver coils
Microcontroller‐based circuitry was built and tested for automatically tuning flexible RF receiver coils at the touch of a button. This circuitry is robust to 10% changes in probe center frequency, is in line with the scanner, and requires less than 1 s to tune a simple probe. Images were acquired using this circuitry with a varactor‐tunable 1‐inch flexible probe in a phantom and in an in vitro porcine knee model. The phantom experiments support the use of automatic tuning by demonstrating 30% signal‐to‐noise ratio (SNR) losses for 5% changes in coil center frequency, in agreement with theoretical calculations. Comparisons between patellofemoral cartilage images obtained using a 3‐inch surface coil and the surgically‐implanted 1‐inch flexible coil reveal a worst‐case local SNR advantage of a factor of 4 for the smaller coil. This work confirms that surgically implanted coils can greatly improve resolution in small‐field‐of‐view (FOV) applications, and demonstrates the importance and feasibility of automatically tuning such probes. Magn Reson Med, 2005.
- 9 September 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 54 (4) , 983-993
Automatic tuning of flexible interventional RF receiver coils
Microcontroller‐based circuitry was built and tested for automatically tuning flexible RF receiver coils at the touch of a button. This circuitry is robust to 10% changes in probe center frequency, is in line with the scanner, and requires less than 1 s to tune a simple probe. Images were acquired using this circuitry with a varactor‐tunable 1‐inch flexible probe in a phantom and in an in vitro porcine knee model. The phantom experiments support the use of automatic tuning by demonstrating 30% signal‐to‐noise ratio (SNR) losses for 5% changes in coil center frequency, in agreement with theoretical calculations. Comparisons between patellofemoral cartilage images obtained using a 3‐inch surface coil and the surgically‐implanted 1‐inch flexible coil reveal a worst‐case local SNR advantage of a factor of 4 for the smaller coil. This work confirms that surgically implanted coils can greatly improve resolution in small‐field‐of‐view (FOV) applications, and demonstrates the importance and feasibility of automatically tuning such probes. Magn Reson Med, 2005.