Three‐dimensional prepolarized magnetic resonance imaging using rapid acquisition with relaxation enhancement
Open Access
- 6 October 2006
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 56 (5) , 1085-1095
Abstract
Prepolarized MRI (PMRI) with pulsed electromagnets has the potential to produce diagnostic quality 0.5‐ to 1.0‐T images with significantly reduced cost, susceptibility artifacts, specific absorption rate, and gradient noise. In PMRI, the main magnetic field cycles between a high field (Bp) to polarize the sample and a homogeneous, low field (B0) for data acquisition. This architecture combines the higher SNR of the polarizing field with the imaging benefits of the lower field. However, PMRI can only achieve high SNR efficiency for volumetric imaging with 3D rapid imaging techniques, such as rapid acquisition with relaxation enhancement (RARE) (FSE, TSE), because slice‐interleaved acquisition and longitudinal magnetization storage are both inefficient in PMRI. This paper demonstrates the use of three techniques necessary to achieve efficient, artifact‐free RARE in PMRI: quadratic nulling of concomitant gradient fields, electromotive force cancelation during field ramping, and phase compensation of CPMG echo trains. This paper also demonstrates the use of 3D RARE in PMRI to achieve standard T1 and fat‐suppressed T2 contrast in phantoms and in vivo wrists. These images show strong potential for future clinical application of PMRI to extremity musculoskeletal imaging and peripheral angiography. Magn Reason Med, 2006. © 2006 Wiley‐Liss.Inc.Keywords
This publication has 20 references indexed in Scilit:
- Prepolarized magnetic resonance imaging around metal orthopedic implantsMagnetic Resonance in Medicine, 2006
- Magnetic resonance imaging with T1 dispersion contrastMagnetic Resonance in Medicine, 2006
- On concomitant gradients in low-field MRIJournal of Magnetic Resonance, 2005
- SQUID-Detected in vivo MRI at Microtesla Magnetic FieldsIEEE Transactions on Applied Superconductivity, 2005
- Image artifacts in very low magnetic field MRI: The role of concomitant gradientsJournal of Magnetic Resonance, 2005
- Shim design using a linear programming algorithmMagnetic Resonance in Medicine, 2004
- Homogeneous magnet design using linear programmingIEEE Transactions on Magnetics, 2000
- Novel approaches to low‐cost MRIMagnetic Resonance in Medicine, 1993
- Comparing the FAISE method with conventional dual‐echo sequencesJournal of Magnetic Resonance Imaging, 1991
- Multiecho imaging sequences with low refocusing flip anglesJournal of Magnetic Resonance (1969), 1988