Alexander Sappok
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Alexander Sappok has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
Leslie Bromberg
Filter Sensing Technologies Inc., Malden, MA (United States)
15 shared publicationsVictor W. Wong
13 shared publicationsPaul Ragaller
Filter Sensing Technologies Inc., Malden, MA (United States)
11 shared publicationsVictor Wong
Massachusetts Institute of Technology
10 shared publicationsYujun Wang
Cummins
7 shared publicationsCarl Justin Kamp
Massachusetts Institute of Technology
5 shared publications
Latest Publications
- 4 November 2018
- Published by ASME International
Direct Simultaneous Measurement of Particulate Matter and Ammonia Storage on Combined Selective Catalytic Reduction Filter Systems Using Radio Frequency Sensors
Tightening global emissions regulations are motivating interest in the development and implementation of Selective Catalytic Reduction + Filtration (SCRF) systems, which are designed to reduce the concentration of tailpipe particulate matter (PM) and NOx emissions. These systems allow designers to combine the NOx reduction capability of an SCR with the filtration capability of a particulate filter on a single unit. Practical implementation of these systems requires reliable measurement and diagnosis of their state — both with respect to trapped particulate matter as well as adsorbed ammonia. Currently, these systems rely on a variety of gas sensors, mounted upstream or downstream of the system, that only provide an indirect inference of the operation state. In this study, a single radio frequency (RF) sensor was used to perform simultaneous measurements of soot loading and ammonia inventory on an SCRF. Several SCRF core samples were tested at varying soot and ash loads in a catalyst reactor bench. Soot levels were measured by monitoring changes in the bulk dielectric properties within the catalyst using the sensor, while ammonia levels were determined by feeding selected regions of the RF spectrum into a pretrained generalized regression neural network model. Results show the RF sensor is able to directly measure the instantaneous ammonia inventory, while simultaneously providing soot loading measurements within 0.5 g/L. These results confirm that simultaneous measurements of both the PM and ammonia loading state of an SCRF are possible using a single RF sensor via analysis of specific features in the full RF spectrum. The results indicate significant potential to remove the control barriers typically associated with the implementation of advanced SCRF systems.
- 4 November 2018
- Published by ASME International
Direct Simultaneous Measurement of Particulate Matter and Ammonia Storage on Combined Selective Catalytic Reduction Filter Systems Using Radio Frequency Sensors
Tightening global emissions regulations are motivating interest in the development and implementation of Selective Catalytic Reduction + Filtration (SCRF) systems, which are designed to reduce the concentration of tailpipe particulate matter (PM) and NOx emissions. These systems allow designers to combine the NOx reduction capability of an SCR with the filtration capability of a particulate filter on a single unit. Practical implementation of these systems requires reliable measurement and diagnosis of their state — both with respect to trapped particulate matter as well as adsorbed ammonia. Currently, these systems rely on a variety of gas sensors, mounted upstream or downstream of the system, that only provide an indirect inference of the operation state. In this study, a single radio frequency (RF) sensor was used to perform simultaneous measurements of soot loading and ammonia inventory on an SCRF. Several SCRF core samples were tested at varying soot and ash loads in a catalyst reactor bench. Soot levels were measured by monitoring changes in the bulk dielectric properties within the catalyst using the sensor, while ammonia levels were determined by feeding selected regions of the RF spectrum into a pretrained generalized regression neural network model. Results show the RF sensor is able to directly measure the instantaneous ammonia inventory, while simultaneously providing soot loading measurements within 0.5 g/L. These results confirm that simultaneous measurements of both the PM and ammonia loading state of an SCRF are possible using a single RF sensor via analysis of specific features in the full RF spectrum. The results indicate significant potential to remove the control barriers typically associated with the implementation of advanced SCRF systems.
- 31 October 2018
- Published by Office of Scientific and Technical Information (OSTI)
Improved Fuel Efficiency through Adaptive Radio Frequency Controls and Diagnostics for Advanced Catalyst System
This project applied radio frequency (RF) sensing to directly measure multiple gas species adsorbed on catalysts with a single device, and demonstrated engine efficiency and cost benefits via adaptive feedback controls not possible with current sensors. Completion of this project has overcome key emissions control barriers identified by DOE, and will enable increased market penetration of highly efficient dilute gasoline, clean diesel, and low-temperature combustion engines. The outcomes have broad implications for future VTO Multi-Year Program Plans and, more importantly, tangible efficiency and commercial benefits.
- 31 October 2018
- Published by Office of Scientific and Technical Information (OSTI)
Improved Fuel Efficiency through Adaptive Radio Frequency Controls and Diagnostics for Advanced Catalyst System
This project applied radio frequency (RF) sensing to directly measure multiple gas species adsorbed on catalysts with a single device, and demonstrated engine efficiency and cost benefits via adaptive feedback controls not possible with current sensors. Completion of this project has overcome key emissions control barriers identified by DOE, and will enable increased market penetration of highly efficient dilute gasoline, clean diesel, and low-temperature combustion engines. The outcomes have broad implications for future VTO Multi-Year Program Plans and, more importantly, tangible efficiency and commercial benefits.
- 9 July 2018
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 140 (11)
Catalyst Ammonia Storage Measurements Using Radio Frequency Sensing1
Motivated by increasingly strict nitrogen oxides (NOx) limits, engine manufacturers have adopted selective catalytic reduction (SCR) technology to reduce engine-out NOx. In the SCR process, NOx react with ammonia (NH3) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NOx and/or NH3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF)-based method to directly monitor the ammonia storage state of the SCR. This approach utilizes the catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH3) were evaluated over a wide range of frequencies, temperatures, and exhaust conditions. The RF response to NH3 storage, desorption, and oxidation on the SCR was well correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10% of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NOx conversion and decrease urea consumption.
- 9 July 2018
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 140 (11)
Catalyst Ammonia Storage Measurements Using Radio Frequency Sensing1
Motivated by increasingly strict nitrogen oxides (NOx) limits, engine manufacturers have adopted selective catalytic reduction (SCR) technology to reduce engine-out NOx. In the SCR process, NOx react with ammonia (NH3) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NOx and/or NH3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF)-based method to directly monitor the ammonia storage state of the SCR. This approach utilizes the catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. Ammonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored ammonia (NH3) were evaluated over a wide range of frequencies, temperatures, and exhaust conditions. The RF response to NH3 storage, desorption, and oxidation on the SCR was well correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10% of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NOx conversion and decrease urea consumption.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Developing Design Guidelines for an SCR Assembly Equipped for RF Sensing of NH 3 Loading
The Cu-zeolite (CuZ) SCR catalyst enables higher NOx conversion efficiency in part because it can store a significant amount of NH3. “NH3 storage control”, where diesel exhaust fluid (DEF) is dosed in accord with a target NH3 loading, is widely used with CuZ catalysts to achieve very high efficiency. The NH3 loading actually achieved on the catalyst is currently estimated through a stoichiometric calculation. With future high-capacity CuZ catalyst designs, it is likely that the accuracy of this NH3 loading estimate will become limiting for NOx conversion efficiency. Therefore, a direct measurement of NH3 loading is needed; RF sensing enables this. Relative to RF sensing of soot in a DPF (which is in commercial production), RF sensing of NH3 adsorbed on CuZ is more challenging. Therefore, more attention must be paid to the “microwave resonance cavity” created within the SCR assembly. The objective of this study was to develop design guidelines to enable and enhance RF sensing. Catalyst dimensions, cavity-defining design features, and antenna location and length were considered. RF measurements were made on a commercial SCR unit outfitted with antennas in various locations. In addition, a simulation tool was used to characterize the RF signals obtained with different design features within the context of an L12 screening DOE. Results of the simulations identified means for optimizing the cavity design and geometry, as well as antenna position, to enhance RF measurements of stored ammonia and enable direct feedback control based on the actual SCR ammonia storage state.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Developing Design Guidelines for an SCR Assembly Equipped for RF Sensing of NH 3 Loading
The Cu-zeolite (CuZ) SCR catalyst enables higher NOx conversion efficiency in part because it can store a significant amount of NH3. “NH3 storage control”, where diesel exhaust fluid (DEF) is dosed in accord with a target NH3 loading, is widely used with CuZ catalysts to achieve very high efficiency. The NH3 loading actually achieved on the catalyst is currently estimated through a stoichiometric calculation. With future high-capacity CuZ catalyst designs, it is likely that the accuracy of this NH3 loading estimate will become limiting for NOx conversion efficiency. Therefore, a direct measurement of NH3 loading is needed; RF sensing enables this. Relative to RF sensing of soot in a DPF (which is in commercial production), RF sensing of NH3 adsorbed on CuZ is more challenging. Therefore, more attention must be paid to the “microwave resonance cavity” created within the SCR assembly. The objective of this study was to develop design guidelines to enable and enhance RF sensing. Catalyst dimensions, cavity-defining design features, and antenna location and length were considered. RF measurements were made on a commercial SCR unit outfitted with antennas in various locations. In addition, a simulation tool was used to characterize the RF signals obtained with different design features within the context of an L12 screening DOE. Results of the simulations identified means for optimizing the cavity design and geometry, as well as antenna position, to enhance RF measurements of stored ammonia and enable direct feedback control based on the actual SCR ammonia storage state.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Continuous Particulate Filter State of Health Monitoring Using Radio Frequency Sensing
Reliable means for on-board detection of particulate filter failures or malfunctions are needed to meet diagnostics (OBD) requirements. Detecting these failures, which result in tailpipe particulate matter (PM) emissions exceeding the OBD limit, over all operating conditions is challenging. Current approaches employ differential pressure sensors and downstream PM sensors, in combination with particulate filter and engine-out soot models. These conventional monitors typically operate over narrowly-defined time windows and do not provide a direct measure of the filter’s state of health. In contrast, radio frequency (RF) sensors, which transmit a wireless signal through the filter substrate provide a direct means for interrogating the condition of the filter itself. This study investigated the use of RF sensors for the continuous measurement of filter trapping efficiency, which was compared to downstream measurements with an AVL Microsoot Sensor, and a PM sampling probe simulating the geometry and installation configuration of a conventional PM sensor. The study included several particulate filter failure modes, both above and below the OBD threshold. The results confirmed the use of RF sensors to provide a direct and continuous measure of the particulate filter’s state of health over a range of typical in-use operating conditions, thereby significantly increasing the time window over which filter failures may be detected.
- 3 April 2018
- Published by SAE International in SAE International Journal of Advances and Current Practices in Mobility
- Vol. 1
Continuous Particulate Filter State of Health Monitoring Using Radio Frequency Sensing
Reliable means for on-board detection of particulate filter failures or malfunctions are needed to meet diagnostics (OBD) requirements. Detecting these failures, which result in tailpipe particulate matter (PM) emissions exceeding the OBD limit, over all operating conditions is challenging. Current approaches employ differential pressure sensors and downstream PM sensors, in combination with particulate filter and engine-out soot models. These conventional monitors typically operate over narrowly-defined time windows and do not provide a direct measure of the filter’s state of health. In contrast, radio frequency (RF) sensors, which transmit a wireless signal through the filter substrate provide a direct means for interrogating the condition of the filter itself. This study investigated the use of RF sensors for the continuous measurement of filter trapping efficiency, which was compared to downstream measurements with an AVL Microsoot Sensor, and a PM sampling probe simulating the geometry and installation configuration of a conventional PM sensor. The study included several particulate filter failure modes, both above and below the OBD threshold. The results confirmed the use of RF sensors to provide a direct and continuous measure of the particulate filter’s state of health over a range of typical in-use operating conditions, thereby significantly increasing the time window over which filter failures may be detected.
- Open Access
- 28 December 2017
- Published by Tsinghua University Press in Journal of Advanced Ceramics
- Vol. 7 (1) , 5-16
Effects of regenerative mechanical vibration on the mechanical integrity of ceramic diesel particulate filters
In this study, the effects of mechanical vibration on the mechanical properties of ceramic diesel particulate filters (DPFs) were investigated. The goal is to determine how the mechanical vibration used in the regenerative ash cleaning process for these filters affects their mechanical integrity during subsequent reuse. Both virgin and vibrated DPF samples were subjected to com-pressive and 3-point flexural loading at three different loading rates along axial and tangential directions. Statistical analysis was conducted to determine the significance of variation in the compressive and flexural strengths of the DPFs as a result of exposure to mechanical vibration. The results show that there is no statistically significant difference in both compressive and flexural strengths of the virgin DPFs and the DPFs subjected to the same level of mechanical vibration typically used in ash cleaning of DPFs. When the intensity of vibration was doubled, the drop in compressive strength became statistically significant, but less than 10% under axial loading. However, no drop in flexural strength was observed for DPFs subjected to this high intensity of mechanical vibration. The safe threshold for mechanical vibration of ceramic filters is considered to be much higher than that currently used in vibration-based ash cleaning process.
- 28 December 2017
- Published by Tsinghua University Press in Journal of Advanced Ceramics
- Vol. 7 (1) , 5-16
Open AccessEffects of regenerative mechanical vibration on the mechanical integrity of ceramic diesel particulate filters
In this study, the effects of mechanical vibration on the mechanical properties of ceramic diesel particulate filters (DPFs) were investigated. The goal is to determine how the mechanical vibration used in the regenerative ash cleaning process for these filters affects their mechanical integrity during subsequent reuse. Both virgin and vibrated DPF samples were subjected to com-pressive and 3-point flexural loading at three different loading rates along axial and tangential directions. Statistical analysis was conducted to determine the significance of variation in the compressive and flexural strengths of the DPFs as a result of exposure to mechanical vibration. The results show that there is no statistically significant difference in both compressive and flexural strengths of the virgin DPFs and the DPFs subjected to the same level of mechanical vibration typically used in ash cleaning of DPFs. When the intensity of vibration was doubled, the drop in compressive strength became statistically significant, but less than 10% under axial loading. However, no drop in flexural strength was observed for DPFs subjected to this high intensity of mechanical vibration. The safe threshold for mechanical vibration of ceramic filters is considered to be much higher than that currently used in vibration-based ash cleaning process.
- 15 October 2017
- Published by ASME International
Catalyst Ammonia Storage Measurements Using Radio Frequency Sensing
Motivated by increasingly strict NOx limits, engine manufactures have adopted selective catalytic reduction (SCR) technology to reduce engine-out NOx below mandated levels. In the SCR process, nitrogen oxides (NOx) react with ammonia (NH3) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NOx and/or NH3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF) -based method to directly monitor the ammonia storage state of the SCR catalyst. This approach utilizes the SCR catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. A mmonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored a mmonia (NH3) were evaluated over a wide frequency range as well as temperature and exhaust conditions. The RF response to NH3 storage, desorption, and oxidation on the SCR was observed to be well-correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10 % of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NOx conversion and decrease urea consumption.
- 15 October 2017
- Published by ASME International
Catalyst Ammonia Storage Measurements Using Radio Frequency Sensing
Motivated by increasingly strict NOx limits, engine manufactures have adopted selective catalytic reduction (SCR) technology to reduce engine-out NOx below mandated levels. In the SCR process, nitrogen oxides (NOx) react with ammonia (NH3) to form nitrogen and water vapor. The reaction is influenced by several variables, including stored ammonia on the catalyst, exhaust gas composition, and catalyst temperature. Currently, measurements from NOx and/or NH3 sensors upstream and downstream of the SCR are used with predictive models to estimate ammonia storage levels on the catalyst and control urea dosing. This study investigated a radio frequency (RF) -based method to directly monitor the ammonia storage state of the SCR catalyst. This approach utilizes the SCR catalyst as a cavity resonator, in which an RF antenna excites electromagnetic waves within the cavity to monitor changes in the catalyst state. A mmonia storage causes changes in the dielectric properties of the catalyst, which directly impacts the RF signal. Changes in the RF signal relative to stored a mmonia (NH3) were evaluated over a wide frequency range as well as temperature and exhaust conditions. The RF response to NH3 storage, desorption, and oxidation on the SCR was observed to be well-correlated with changes in the catalyst state. Calibrated RF measurements demonstrate the ability to monitor the adsorption state of the SCR to within 10 % of the sensor full scale. The results indicate direct measurement of SCR ammonia storage levels, and resulting catalyst feedback control, via RF sensing to have significant potential for optimizing the SCR system to improve NOx conversion and decrease urea consumption.
- 28 March 2017
- Published by SAE International in SAE International Journal of Fuels and Lubricants
- Vol. 10 (2) , 608-618
Ash Permeability Determination in the Diesel Particulate Filter from Ultra-High Resolution 3D X-Ray Imaging and Image-Based Direct Numerical Simulations
Diesel engine exhaust aftertreatment components, especially the diesel particulate filter (DPF), are subject to various modes of degradation over their lifetimes. One particular adverse effect on the DPF is the significant rise in pressure drop due to the accumulation of engine lubricant-derived ash which coats the inlet channel walls effectively decreasing the permeability of the filter. The decreased permeability due to ash in the DPF can result in increased filter pressure drop and decreased fuel economy. A unique two-step approach, consisting of experimental measurements and direct numerical simulations using ultra-high resolution 3D imaging data, has been utilized in this study to better understand the effects of ash accumulation on engine aftertreatment component functionality.In this study, ash permeability was directly measured on the surface of ceramic (cordierite) wafers as a function of ash type (field ash, lab-generated and with chemical/morphological variations) and packing density. Ultra-high resolution X-ray Computed Tomography (CT) with a transmission X-ray source (voxel size ~500nm) was utilized for direct and accurate 3D visualization of the catalyst substrate structure, the individual ash particles (which have an average size of 1-2µm) and the ash which penetrates into the substrate surface pores. In combination with CT data deep image analysis, a new generation of direct numerical simulation algorithms (solving Naiver-Stokes equations efficiently for imaging data with billions of voxels) is used to compute permeability of the combined ash/washcoat/substrate system directly from the 3D CT images.This study discusses the sample preparations necessary for high CT resolution, the combination of CT data and deep image processing for permeability calculations, the comparison between calculated and experimentally measured permeability values and the implications of the ability to calculate accurate permeability values in the combined ash-catalyst substrate system.
- 28 March 2017
- Published by SAE International in SAE International Journal of Fuels and Lubricants
- Vol. 10 (2) , 608-618
Ash Permeability Determination in the Diesel Particulate Filter from Ultra-High Resolution 3D X-Ray Imaging and Image-Based Direct Numerical Simulations
Diesel engine exhaust aftertreatment components, especially the diesel particulate filter (DPF), are subject to various modes of degradation over their lifetimes. One particular adverse effect on the DPF is the significant rise in pressure drop due to the accumulation of engine lubricant-derived ash which coats the inlet channel walls effectively decreasing the permeability of the filter. The decreased permeability due to ash in the DPF can result in increased filter pressure drop and decreased fuel economy. A unique two-step approach, consisting of experimental measurements and direct numerical simulations using ultra-high resolution 3D imaging data, has been utilized in this study to better understand the effects of ash accumulation on engine aftertreatment component functionality.In this study, ash permeability was directly measured on the surface of ceramic (cordierite) wafers as a function of ash type (field ash, lab-generated and with chemical/morphological variations) and packing density. Ultra-high resolution X-ray Computed Tomography (CT) with a transmission X-ray source (voxel size ~500nm) was utilized for direct and accurate 3D visualization of the catalyst substrate structure, the individual ash particles (which have an average size of 1-2µm) and the ash which penetrates into the substrate surface pores. In combination with CT data deep image analysis, a new generation of direct numerical simulation algorithms (solving Naiver-Stokes equations efficiently for imaging data with billions of voxels) is used to compute permeability of the combined ash/washcoat/substrate system directly from the 3D CT images.This study discusses the sample preparations necessary for high CT resolution, the combination of CT data and deep image processing for permeability calculations, the comparison between calculated and experimentally measured permeability values and the implications of the ability to calculate accurate permeability values in the combined ash-catalyst substrate system.
- 28 March 2017
- Published by SAE International in SAE International Journal of Engines
- Vol. 10 (4) , 1667-1682
On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing
The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this study, radio frequency (RF) sensors were used to directly monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.
- 28 March 2017
- Published by SAE International in SAE International Journal of Engines
- Vol. 10 (4) , 1667-1682
On-Board Particulate Filter Failure Prevention and Failure Diagnostics Using Radio Frequency Sensing
The increasing use of diesel and gasoline particulate filters requires advanced on-board diagnostics (OBD) to prevent and detect filter failures and malfunctions. Early detection of upstream (engine-out) malfunctions is paramount to preventing irreversible damage to downstream aftertreatment system components. Such early detection can mitigate the failure of the particulate filter resulting in the escape of emissions exceeding permissible limits and extend the component life. However, despite best efforts at early detection and filter failure prevention, the OBD system must also be able to detect filter failures when they occur. In this study, radio frequency (RF) sensors were used to directly monitor the particulate filter state of health for both gasoline particulate filter (GPF) and diesel particulate filter (DPF) applications. The testing included controlled engine dynamometer evaluations, which characterized soot slip from various filter failure modes, as well as on-road fleet vehicle tests. The results show a high sensitivity to detect conditions resulting in soot leakage from the particulate filter, as well as potential for direct detection of structural failures including internal cracks and melted regions within the filter media itself. Furthermore, the measurements demonstrate, for the first time, the capability to employ a direct and continuous monitor of particulate filter diagnostics to both prevent and detect potential failure conditions in the field.
- 30 October 2016
- Published by Office of Scientific and Technical Information (OSTI)
Radio Frequency Sensing of Particulate Matter Accumulation on a Gasoline Particulate Filter
Filter Sensing Technology’s radio frequency (RF) sensor for particulate filter on-board diagnostics (OBD) was studied on a lean gasoline engine at the National Transportation Research Center (NTRC) at Oak Ridge National Laboratory (ORNL). The response of the RF sensor to particulate matter (PM) or “soot” accumulation on the gasoline particulate filter (GPF) installed in the engine exhaust was evaluated. In addition, end plugs of the GPF were purposely removed, and subsequent changes to the RF sensor measured soot loading on the GPF were characterized. Results from the study showed that the RF sensor can accurately measure soot accumulation on a GPF; furthermore, the predicted decreased soot accumulation due to plug removal was detected by the RF sensor. Overall, the studies were short and preliminary in nature; however, clearly, the RF sensor demonstrated the capability of measuring GPF soot loading at a level suitable for use in lean gasoline engine emission control OBD and control.
- 30 October 2016
- Published by Office of Scientific and Technical Information (OSTI)
Radio Frequency Sensing of Particulate Matter Accumulation on a Gasoline Particulate Filter
Filter Sensing Technology’s radio frequency (RF) sensor for particulate filter on-board diagnostics (OBD) was studied on a lean gasoline engine at the National Transportation Research Center (NTRC) at Oak Ridge National Laboratory (ORNL). The response of the RF sensor to particulate matter (PM) or “soot” accumulation on the gasoline particulate filter (GPF) installed in the engine exhaust was evaluated. In addition, end plugs of the GPF were purposely removed, and subsequent changes to the RF sensor measured soot loading on the GPF were characterized. Results from the study showed that the RF sensor can accurately measure soot accumulation on a GPF; furthermore, the predicted decreased soot accumulation due to plug removal was detected by the RF sensor. Overall, the studies were short and preliminary in nature; however, clearly, the RF sensor demonstrated the capability of measuring GPF soot loading at a level suitable for use in lean gasoline engine emission control OBD and control.